Search NASA⌕ Search

SEARCH · Search NASA

Results for “PULSE RATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Reliability of psychophysiological responses across multiple motion sickness stimulation tests

Although there is general agreement that a high degree of variability exists between subjects in their autonomic nervous system responses to motion sickness stimulation, very little evidence exists that examines the reproducibility of autonomic responses within subjects during motion sickness stimulation. Our objectives were to examine the reliability of autonomic responses and symptom levels across five testing occasions using the (1) final minute of testing, (2) change in autonomic response and the change in symptom level, and (3) strength of the relationship between the change in symptom level and the change in autonomic responses across the entire motion sickness test. The results indicate that, based on the final minute of testing, the autonomic responses of heart rate, blood volume pulse, and respiration rate are moderately stable across multiple tests. Changes in heart rate, blood volume pulse, respiration rate, and symptoms throughout the test duration are less stable across the tests. Finally, autonomic responses and symptom levels are significantly related across the entire motion sickness test.

NASA Discipline Neuroscience↗

New generation lidar systems for eye safe full time observations

The traditional lidar over the last thirty years has typically been a big pulse low repetition rate system. Pulse energies are in the 0.1 to 1.0 J range and repetition rates from 0.1 to 10 Hz. While such systems have proven to be good research tools, they have a number of limitations that prevent them from moving beyond lidar research to operational, application oriented instruments. These problems include a lack of eye safety, very low efficiency, poor reliability, lack of ruggedness and high development and operating costs. Recent advances in solid state laser, detectors and data systems have enabled the development of a new generation of lidar technology that meets the need for routine, application oriented instruments. In this paper the new approaches to operational lidar systems will be discussed. Micro pulse lidar (MPL) systems are currently in use, and their technology is highlighted. The basis and current development of continuous wave (CW) lidar and potential of other technical approaches is presented.

Spinhirne, James D.↗

Radar image processing of real aperture SLAR data for the detection and identification of iceberg and ship targets

An iceberg detection and identification system consisting of a moderate resolution Side Looking Airborne Radar (SLAR) interfaced with a Radar Image Processor (RIP) based on a ROLM 1664 computer with a 32K core memory updatable to 64K is described. The system can be operated in high- or low-resolution sampling modes. Specifically designed algorithms are applied to digitized signal returns to provide automatic target detection and location, geometrically correct video image display and data recording. The real aperture Motorola AN/APS-94D SLAR operates in the X-band and is tunable between 9.10 and 9.40 GHz; its output power is 45 kW peak with a pulse repetition rate of 750 pulses per hour. Schematic diagrams of the system are provided, together with preliminary test data.

Marthaler, J. G.↗

A laser system to remotely sense bird movements

The design and operation of a laser detection system for migrating birds are presented. A battery-powered class-III laser (operating at 904 nm, pulse-repetition rate 5 kHz, pulse duration 100 nsec, and peak power 25 W) and a photodiode receiver are mounted on poles at height 10 m and distance 850 m and equipped with 135-mm f/2.8 collimating lenses; beam diameter at the receiver is 1.7 m. The microprocessor-controlled system is found to detect the passing of an object as small as 30 sq cm in cross section at a distance of 425 m.

Korschgen, C. E.↗

The stability of individual patterns of autonomic responses to motion sickness stimulation

As part of a program to develop a treatment for motion sickness based on self-regulation of autonomic nervous system (ANS) activity, this study examined the stability of an individual's pattern of ANS responses to motion sickness stimulation on repeated occasions. Motion sickness symptoms were induced in 58 people during two rotating chair test. Physiological responses measured were heart rate, finger pulse volume, respiration rate, and skin conductance. Using standard scores, stability of responses of specific magnitudes across both tests is as examined. Correlational analyses, analysis of variance, and a components of variance analysis all revealed marked, but quite stable, individual differences in ANS responses to both mild and severe motion sickness. These findings confirm the prior observation that people are sufficiently unique in their ANS responses to motion sickness provocation to make it nesessary to individually tailor self-regulation training. Further, these data support the contention that individual ANS patterns are sufficiently consistent from test to test so as to serve as an objective indicator of individual motion sickness malaise levels.

Cowings, Patricia S.↗

Performance of efficient Q-switched diode-laser-pumped Nd:YAG and Ho:YLF lasers for space applications

Solid-state lasers pumped by continuous-wave diode lasers can be Q-switched to obtain high peak power output pulses. The dependence of laser-pulse energy, average output power, peak power, and pulse width on pulse-repetition frequency in Q-switched Nd:YAG and Ho:YLF lasers is determined and compared. At low pulse repetition rates, the much longer upper-stage lifetime in Ho:YLF gives a distinct advantage. At higher pulse rates, the overall laser efficiency and the stimulated emission cross section are more important parameters, leading to an advantage for Nd:YAG. The results are of significance for designing lasers for use in space optical communications and remote sensing systems.

Marshall, W. K.↗

Radiation-induced insulator discharge pulses in the CRRES Internal Discharge Monitor satellite experiment

The Internal Discharge Monitor (IDM) is designed to observe electrical pulses from common electrical insulators in space service. The IDM is flying on the Combined Release and Radiation Effects Satellite (CRRES). The sixteen insulator samples include G10 circuit boards, FR4 and PTFE fiberglass circuit boards, FEP Teflon, alumina, and wires with common insulations. The samples are fully enclosed, mutually isolated, and space radiation penetrates 0.02 cm of aluminum before striking the samples. The IDM results indicate the rate at which insulator pulses occur. Pulsing began on the seventh orbit. The maximum pulse rate occurred near orbit 600 when over 50 pulses occurred. The average pulse rate is approximately two per orbit, but nearly half of the first 600 orbits experienced no pulses. The pulse rate per unit flux of high energy electrons has not changed dramatically over the first ten months in space. These pulse rates are in agreement with laboratory experience on shorter time scales. Several of the samples have never pulsed. IDM pulses are the seeds of larger satellite electrical anomalies. The pulse rates are compared with space radiation intensities, L shell location, and spectral distributions from the radiation spectrometers on CRRES.

Frederickson, A. R.↗

Architecture for a 1-GHz Digital RADAR

An architecture for a Direct RF-digitization Type Digital Mode RADAR was developed at GSFC in 2008. Two variations of a basic architecture were developed for use on RADAR imaging missions using aircraft and spacecraft. Both systems can operate with a pulse repetition rate up to 10 MHz with 8 received RF samples per pulse repetition interval, or at up to 19 kHz with 4K received RF samples per pulse repetition interval. The first design describes a computer architecture for a Continuous Mode RADAR transceiver with a real-time signal processing and display architecture. The architecture can operate at a high pulse repetition rate without interruption for an infinite amount of time. The second design describes a smaller and less costly burst mode RADAR that can transceive high pulse repetition rate RF signals without interruption for up to 37 seconds. The burst-mode RADAR was designed to operate on an off-line signal processing paradigm. The temporal distribution of RF samples acquired and reported to the RADAR processor remains uniform and free of distortion in both proposed architectures. The majority of the RADAR's electronics is implemented in digital CMOS (complementary metal oxide semiconductor), and analog circuits are restricted to signal amplification operations and analog to digital conversion. An implementation of the proposed systems will create a 1-GHz, Direct RF-digitization Type, L-Band Digital RADAR--the highest band achievable for Nyquist Rate, Direct RF-digitization Systems that do not implement an electronic IF downsample stage (after the receiver signal amplification stage), using commercially available off-the-shelf integrated circuits.

Mallik, Udayan↗

Optoacoustic measurement of vibrational-translational /V-T/ rates using a short pulse CO2 laser

A technique for measuring the V-T transfer rates of polyatomic species based on the optoacoustic effect discovered by Bell, Tyndall, and Rontgen (1881) is investigated experimentally. The technique makes use of a coincidental resonance between one of the molecules vibration rotation bands and a CO2 laser line. By this absorption, the molecules can be excited to a known vibrational mode. Since typical time constants for V-T transfer are about 0.00001 sec torr, this method can be used in the pressure region up to 1 torr. The results obtained for CH3F agree with the measurements performed by other techniques.

Lawandy, N. M.↗

Satellite tracking and Earth dynamics research programs

Following an upgrading program, ranging performance capabilities of a satellite-tracking pulsed laser system were assessed in terms of range accuracy, range noise, data yield, and reliability. With a shorter laser pulse duration (2.5 to 3.0 NSEC) and a new analog pulse processing system, the systematic range errors were reduced to 3 to 5 cm and range noise was reduced to 5 to 16 cm and range noise was reduced to 5 to 15 cm on Starlette and BE-C, and 10 to 18 cm on LAGEOS. Maximum pulse repetition rate was increased to 30 pulses per minute and significant improvement was made in signal to noise ratio by installing a 3 A interference filter and by reducing the range gate window to 200 to 400 nsec. The solution to a problem involving leakage of a fraction of the laser oscillator pulse through the pulse chopper was outlined.

Pearlman, M. R.↗

Frequency-Channelized Recovery Of Timing

Method of extracting bit or baud rate of excess bandwidth pulse-amplitude-modulated signal based on frequency-domain equivalent of time-domain delay-and-multiply operation. Involves use of outputs of Fourier-transform-based, channelized receiver. Very little priori knowledge of parameters of signal needed, and processing of signal by method yields spectral line at pulse-repetition rate.

Satorius, Edgar H.↗

Elimination of range-aliased echoes in the VHF radars

Very high frequency radars designed to measure tropospheric wind profiles usually detect scattering to a maximum height of about 20 km. If the antenna elevation angle is 45 degrees or more above the horizon, the maximum range of interest is less than 30 km. A VHF pulsed Doppler radar wind Profiler can, therefore, be operated at high pulse repetition rates. The maximum bandwidth allowed is about 0.5 MHz so a radar with uncoded pulses can operate with a duty cycle of 1 to 10%, depending on the desired height resolution. It is possible to operate a tropospheric wind profiler that utilizes all the average power available from the transmitter without the complexity of coded pulses. However, the VHF radar can detect echoes from the mesosphere on occasion and, with high pulse repetition rates, these echoes occur at the same apparent range as the tropospheric echoes. These mesospheric echoes may be stronger than the tropospheric signals. The range-aliased mesospheric echoes can be greatly attenuated or effectively eliminated.

Strauch, R. G.↗

The Laser Atmospheric Wind Sounder (LAWS) Phase 2 Preliminary Laser Design

The requirements for the Laser Atmospheric Wind Sounder (LAWS) were determined from system considerations and are summarized in tabular form. The laser subsystem provides for the generation and frequency control of two beams, the transmit high power and local oscillator beams, which are delivered to the optical and receiver subsystems, respectively. In our baseline approach, the excitation of the gain section is achieved by a self-sustaining uv-(corona) preionized discharge. Gas is recirculated within the laser loop using a transverse flow fan. An intra-flow-loop heat exchanger, catalyst monolith, and acoustic attenuators condition the gas to ensure uniform energy output and high beam quality during high pulse repetition rate operation. The baseline LAWS laser pulse temporal profile as calculated by in-house laser codes is given in graphical form.

Lawrence, T. Rhidian↗

Lidar System for Airborne Measurement of Clouds and Aerosols

A lidar system for measuring optical properties of clouds and aerosols at three wavelengths is depicted. The laser transmitter is based on a Nd:YVO4 laser crystal pumped by light coupled to the crystal via optical fibers from laser diodes that are located away from the crystal to aid in dissipating the heat generated in the diodes and their drive circuits. The output of the Nd:YVO4 crystal has a wavelength of 1064 nm, and is made to pass through frequency-doubling and frequency-tripling crystals. As a result, the net laser output is a collinear superposition of beams at wavelengths of 1064, 532, and 355 nm. The laser operates at a pulse-repetition rate of 5 kHz, emitting per-pulse energies of 50 microJ at 1064 nm, 25 microJ at 532 nm and 50 microJ at 355 nm. An important feature of this system is an integrating sphere located between the laser output and the laser beam expander lenses. The integrating sphere collects light scattered from the lenses. Three energy-monitor detectors are located at ports inside the integrating sphere. Each of these detectors is equipped with filters such that the laser output energy is measured independently for each wavelength. The laser output energy is measured on each pulse to enable the most accurate calibration possible. The 1064-nm and 532-nm photodetectors are, more specifically, single photon-counting modules (SPCMs). When used at 1064 nm, these detectors have approximately 3% quantum efficiency and low thermal noise (fewer than 200 counts per second). When used at 532 nm, the SPCMs have quantum efficiency of about 60%. The photodetector for the 355-nm channel is a photon-counting photomultiplier tube having a quantum efficiency of about 20%. The use of photon-counting detectors is made feasible by the low laser pulse energy. The main advantage of photon-counting is ease of inversion of data without need for complicated calibration schemes like those necessary for analog detectors. The disadvantage of photon-counting detectors is that they inherently have narrow dynamic ranges. However, by using photon-counting detectors along with a high-repetition rate laser, it is possible to obtain wide dynamic range through accumulation of counts over many pulses.

McGill, Matthew↗