Search NASA⌕ Search

SEARCH · Search NASA

Results for “PULSE TECHNIQUES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Encryption of Signal Pulses to Replace Tamper-indicating Conduit

In order to verify signal integrity and point of origin for TTL pulse data used in IAEA systems, and to avoid the need for expensive tamper-indicating conduit or electronic techniques, we propose the development of a signal pulse signing and encryption in-line device. In measurement applications in which the data acquisition electronics is separate from the enclosed, sealed detector, tamper-indicating techniques are required to protect raw TTL pulse streams between the detector and the data acquisition module, i.e UMSR. The goal of this proposed project is to design a rad-tolerant transmitter that would mount inside the sealed detector system and a receiver in the sealed electronics cabinet with the data acquisition instrument. This transmitter/receiver pair would digitally sign and encrypt the pulse stream data at the detector then transmit the data to the sealed cabinet where the receiver would decrypt the data and reproduce the original pulse stream. Existing tamper indicating techniques, such as LiveWire’s spread spectrum time domain reflectometry rely on detecting physical changes to the wiring system and can be blind to fast coupling of micro-second wide pulses. Digital signing and encryption techniques such as the Sandia Laboratories Enhanced Data Authentication System (EDAS) are capable of encrypting communications data, i.e. RS-232, but are not capable reproducing a critical time correlated data streams. Recent NA-241 Safeguards Technology supported developments have reduced the need for special conduit to transmit data via Ethernet by incorporating the IAEA RAINSTORM data encryption and authentication protocol, a tamper indicator is still required to protect raw pulse data from detectors to the acquisition electronics. Encrypting pulse data is especially complicated for radiation detection instruments due to the time correlation data analysis that is performed on this data stream. Any corruption in the timing information will produce errors in measurement values.

97 MATHEMATICS AND COMPUTING↗

Nonlinear optical properties of lanthanum titanate glasses prepared by levitation melting

Lanthanum titanate glasses (17 La 2 O 3 -83 TiO 2 ) are fabricated via aerodynamic levitation melting. Here, nonlinear refraction and absorption were measured with the Z scan technique using ps optical pulses at 532 nm wavelength with peak intensities in the range of 0.25–2.5 GW/cm 2 . The two-photon absorption coefficient (β) and the effective nonlinear refraction coefficient (⁠$n^{eff}_{2}$) are found to be, respectively, 2.19 cm/GW and 152 × 10 -16 cm 2 /W (85 × 10 -13 esu). The Raman gain is measured to be 106 × 10 -11 cm/W. The nonlinearity strength is found to be nearly 60 times larger in lanthanum titanate glasses relative to silica.

36 MATERIALS SCIENCE↗

Robust Quantum Control via Multipath Interference for Thousandfold Phase Amplification in a Resonant Atom Interferometer

We introduce a novel technique for enhancing the robustness of light-pulse atom interferometers against the pulse infidelities that typically limit their sensitivities. The technique uses quantum optimal control to favorably harness the multipath interference of the stray trajectories produced by imperfect atom-optics operations. We apply this method to a resonant atom interferometer and achieve thousandfold phase amplification, representing a 50-fold improvement over the performance observed without optimized control. Moreover, we find that spurious interference can arise from the interplay of spontaneous emission and many-pulse sequences and demonstrate optimization strategies to mitigate this effect. Given the ubiquity of spontaneous emission in quantum systems, these results may be valuable for improving the performance of a diverse array of quantum sensors. We anticipate our findings will significantly benefit the performance of matter-wave interferometers for a variety of applications, including dark matter, dark energy, and gravitational wave detection.

47 OTHER INSTRUMENTATION↗

Understanding the impact of an applied axial magnetic field on efficient current coupling on the Z machine

Magnetized liner inertial fusion (MagLIF) is an attractive concept for producing thermonuclear fusion reactions. The MagLIF platform involves the operation of Helmholtz coils to apply a 15 Tesla axial magnetic field to the load region, where a cylindrical, fuel-filled metal liner is imploded by a ∼ 2 0 MA current pulse. The fringe field from these coils extends into the transmission line that delivers the current to the target. We investigated the extent to which this applied field disturbs the nominal power flow within that transmission line. A simplified model of the geometry shows that adding the applied magnetic field results in magnetic field lines that connect the cathode to the anode, suggesting electrons may not be magnetically insulated in this region. Particle-in-cell simulations indicated the addition of the applied magnetic field would not significantly impact the current delivery to the load. Velocimetry was used to experimentally assess the current delivery with and without the applied magnetic field. We find no measurable effects of the applied field on current delivery in the configuration investigated in this study. Published by the American Physical Society 2024

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Epitaxial growth and characterization of magnesium gallate (MgGa 2 O 4 ) thin films by pulsed laser deposition

To advance high power device application of MgGa 2 O 4 , it is imperative to achieve crystalline epitaxial thin films and to observe its materials’ characteristics within a wide range of growth conditions. However, there is no published work on the growth of this promising ultrawide bandgap material till this day. In this study, we report the crystalline growth of MgGa 2 O 4 thin films on c-plane (006) sapphire substrates using the pulsed laser deposition (PLD) technique in a broad range of temperature and oxygen pressure. The temperature range for this crystalline growth was within the temperature range of 300°C to 700°C and a pressure range of 1x10 -1 to 1x10 -3 Torr. Within this parameter range, the structural, chemical, optical, and surface property of MgGa 2 O 4 thin films have been investigated. Specifically, the acquired XRD patterns confirmed the film growth along the [111] preferential crystal orientation in the lattice. Here, the rocking curve measurement of the prominent (222) plane showed an increasing trend of the crystallinity with growth temperature and pressure. Furthermore, the XRD phi (φ) scan demonstrated the six-fold rotational symmetry of the MgGa 2 O 4 films and the epitaxial relationship of 30° between the film and the sapphire substrate. The XPS spectra confirmed the presence of +2 and +3 oxidation state for Mg and Ga respectively, in the films. The direct bandgap of MgGa 2 O 4 films was obtained ~5.27±0.03 eV by analyzing the UV-Vis absorbance spectra using the Tauc equation. The SEM images exhibited a granular surface morphology of the MgGa 2 O 4 films with an increasing trend in the grain size from low to high temperature and pressure. The refractive index and thickness of these films were in the range of ~1.90±0.02 and ~70±2.0 nm, respectively determined by fitting the spectroscopic ellipsometry data.

36 MATERIALS SCIENCE↗

Novel self-assembled two-dimensional layered oxide structure incorporated with Au nanoinclusions towards multifunctionalities

Two-dimensional (2D) layered oxides have recently attracted wide attention owing to the strong coupling among charges, spins, lattice, and strain, which allows great flexibility and opportunities in structure designs as well as multifunctionality exploration. In parallel, plasmonic hybrid nanostructures exhibit exotic localized surface plasmon resonance (LSPR) providing a broad range of applications in nanophotonic devices and sensors. A hybrid material platform combining the unique multifunctional 2D layered oxides and plasmonic nanostructures brings optical tuning into the new level. Here, a novel self-assembled Bi 2 MoO 6 (BMO) 2D layered oxide incorporated with plasmonic Au nanoinclusions has been demonstrated via one-step pulsed laser deposition (PLD) technique. Comprehensive microstructural characterizations, including scanning transmission electron microscopy (STEM), differential phase contrast imaging (DPC), and STEM tomography, have demonstrated the high epitaxial quality and particle-in-matrix morphology of the BMO-Au nanocomposite film. DPC-STEM imaging clarifies the magnetic domain structures of BMO matrix. Three different BMO structures including layered supercell (LSC) and superlattices have been revealed which is attributed to the variable strain states throughout the BMO-Au film. Owing to the combination of plasmonic Au and layered structure of BMO, the nanocomposite film exhibits a typical LSPR in visible wavelength region and strong anisotropy in terms of its optical and ferromagnetic properties. This study opens a new avenue for developing novel 2D layered complex oxides incorporated with plasmonic metal or semiconductor phases showing great potential for applications in multifunctional nanoelectronics devices.

36 MATERIALS SCIENCE↗

Online and noninvasive monitoring of battery health at negative-half cell in all-vanadium redox flow batteries using ultrasound

Hydrogen evolution is one of the major side reactions that is detrimental to the health of all-vanadium redox flow batteries, especially for long-term cycling. Effective, low-cost, and accurate online prediction and detection methods for hydrogen generation are not yet available. In this work, we designed an online, noninvasive ultrasonic probing approach for monitoring the state of charge (SoC), predicting the hydrogen generation, and detecting hydrogen gas bubbles in anolyte solutions. The technique employs a pulse-echo method to measure the sound speed and the acoustic attenuation coefficient of the anolyte solution. Through static offline experiments and online in operando experiments, we have demonstrated that when hydrogen gas is generated in anolyte solutions, large variations are observed in both sound speed and acoustic attenuation coefficient measurements. We found that the variations of acoustic attenuation coefficient are highly correlated (correlation coefficients >0.9) with the gas flow rate. In conclusion, the designed acoustic method can monitor the SoC of anolyte, predict the hydrogen generation, and detect the presence of gas bubbles in an anolyte solution and, thus, provide information about the state of health for operation and management of flow battery systems.

25 ENERGY STORAGE↗

Machine learning-assisted ultrafast flash sintering of high-performance and flexible silver–selenide thermoelectric devices

Flexible thermoelectric generators (TEGs) have shown immense potential for serving as a power source for wearable electronics and the Internet of Things. A key challenge preventing large-scale application of TEGs lies in the lack of a high-throughput processing method, which can sinter thermoelectric (TE) materials rapidly while maintaining their high thermoelectric properties. Herein, we integrate high-throughput experimentation and Bayesian optimization (BO) to accelerate the discovery of the optimum sintering conditions of silver–selenide TE films using an ultrafast intense pulsed light (flash) sintering technique. Due to the nature of the high-dimensional optimization problem of flash sintering processes, a Gaussian process regression (GPR) machine learning model is established to rapidly recommend the optimum flash sintering variables based on Bayesian expected improvement. For the first time, an ultrahigh-power factor flexible TE film (a power factor of 2205 μW m -1 K -2 with a zT of 1.1 at 300 K) is demonstrated with a sintering time less than 1.0 second, which is several orders of magnitude shorter than that of conventional thermal sintering techniques. Further, the films also show excellent flexibility with 92% retention of the power factor (PF) after 10 3 bending cycles with a 5 mm bending radius. In addition, a wearable thermoelectric generator based on the flash-sintered films generates a very competitive power density of 0.5 mW cm -2 at a temperature difference of 10 K. This work not only shows the tremendous potential of high-performance and flexible silver–selenide TEGs but also demonstrates a machine learning-assisted flash sintering strategy that could be used for ultrafast, high-throughput and scalable processing of functional materials for a broad range of energy and electronic applications.

25 ENERGY STORAGE↗

Neural Learning Based Blind Source Separation for Detection of Material Defects in Pulsed Thermography Images

In this paper, we introduce a neural learning-based approach to blind source separation for detection of material flaws in pulsed thermography (PT) images. This approach can be used to detect internal defects (pores) in metallic Additively Manufactured (AM) materials. Such defects occur in high-strength alloys produced with direct laser sintering AM method for nuclear energy applications. Pulsed thermal imaging system utilizes a high intensity flash lamp to rapidly heat surface of sample, a high sensitivity infrared camera to capture data of surface temperature variations. The data cube obtained with PT (stack of surface temperature images at different times) can be analyzed with image processing algorithms to detect material defects. Compared with conventional nondestructive evaluation (NDE) methods, such as digital radiography and ultrasonic testing, the PT pulsed infrared thermal detection technique has advantages of one-sided non-contact measurements, fast processing of large sample areas captured in one image. Detection of small material defects requires finding features in thermal images, which have signal contrast levels approaching sensitivity limit of IR camera. In this study, an optimized Neural Learning based Blind Source Separation (NLBSS) algorithm, including Principal Component Analysis (PCA), and Independent Component Analysis (ICA) is demonstrated to automatically extract principal temporal and spatial features of thermography frames to enhance flaw detection. By using the NLBSS algorithm, material internal defects can be automatically detected. Furthermore, this processing approach compensates for experimental thermal imaging artifacts, such as noise and uneven heating. By merging artificial intelligence with the photothermic, the NDE system detects internal calibrated defects of various sizes and depths in AM nuclear-grade metallic alloys.

Zhang, Xin↗

The Double Chooz antineutrino detectors

This article describes the setup and performance of the near and far detectors in the Double Chooz experiment. The electron antineutrinos of the Chooz nuclear power plant were measured in two identically designed detectors with different average baselines of about 400 m and 1050 m from the two reactor cores. Over many years of data taking the neutrino signals were extracted from interactions in the detectors with the goal of measuring a fundamental parameter in the context of neutrino oscillation, the mixing angle $\theta _{13}$. The central part of the Double Chooz detectors was a main detector comprising four cylindrical volumes filled with organic liquids. From the inside towards the outside there were volumes containing gadolinium-loaded scintillator, gadolinium-free scintillator, a buffer oil and, optically separated, another liquid scintillator acting as veto system. Above this main detector an additional outer veto system using plastic scintillator strips was installed. The technologies developed in Double Chooz were inspiration for several other antineutrino detectors in the field. The detector design allowed implementation of efficient background rejection techniques including use of pulse shape information provided by the data acquisition system. The Double Chooz detectors featured remarkable stability, in particular for the detected photons, as well as high radiopurity of the detector components.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coupling Pulse Radiolysis with Nanosecond Time-Resolved Step-Scan Fourier Transform Infrared Spectroscopy: Broadband Mid-Infrared Detection of Radiolytically Generated Transients

We describe the first implementation of broadband, nanosecond time-resolved step-scan Fourier transform infrared (S 2 -FT-IR) spectroscopy at a pulse radiolysis facility. This new technique allows the rapid acquisition of nano- to microsecond time-resolved infrared (TRIR) spectra of transient species generated by pulse radiolysis of liquid samples at a pulsed electron accelerator. Wide regions of the mid-infrared can be probed in a single experiment, which often takes < 20–30 min to complete. It is therefore a powerful method for rapidly locating the IR absorptions of short-lived, radiation-induced species in solution, and for directly monitoring their subsequent reactions. Time-resolved step-scan FT-IR detection for pulse radiolysis thus complements our existing narrowband quantum cascade laser-based pulse radiolysis-TRIR detection system, which is more suitable for acquiring single-shot kinetics and narrowband TRIR spectra on small-volume samples and in strongly absorbing solvents, such as water. We have demonstrated the application of time-resolved step-scan FT-IR spectroscopy to pulse radiolysis by probing the metal carbonyl and organic carbonyl vibrations of the one-electron-reduced forms of two Re-based CO 2 reduction catalysts in acetonitrile solution. Transient IR absorption bands with amplitudes on the order of 1 × 10 −3 are easily detected on the sub-microsecond timescale using electron pulses as short as 250 ns.

(S2-FT-IR)↗

Growth and Development of Quantum Materials

Topological insulators (TIs) display a new state of quantum matter, which is broadly known as quantum materials. The TIs have a unique property of being an insulator as a bulk property and having conducting surface states, which are symmetry-protected Dirac Fermions and well isolated from the bulk valence and conduction bands. Ideally, these topological surface states and bulk electronic states should act independently. The degree to which they intermix depends on the crystalline quality, composition and defects present in the material. These materials thus demand very high-quality crystals to observe the desired quantum properties. We proposed growth of high-quality single crystals and thin films to enhance the ability to fabricate devices with unique performance attributes. Two separate approaches will be made to make the thin films, one is exfoliation of 2D monolayer from the grown single crystals and the second is thin films grown by pulsed laser deposition. Both techniques will subsequently allow for fabrication of meso structures using a Focused Ion Beam technique.

36 MATERIALS SCIENCE↗

Silver Nanowire-Indium Zinc Oxide Composite Flexible Transparent Conducting Electrodes Made by Spin- coating and Photonic Curing

Realizing high-throughput, low-cost perovskite solar cell (PSC) manufacturing is highly sought-after in photovoltaic (PV) research in recent years. To fully achieve roll-to-roll (R2R) manufacturing of PSCs, it is important to consider the flexible transparent electrode (TE). PET/ITO is a commonly used substrate for making flexible PSCs. When optimizing transparent conducting materials, there is a tradeoff between sheet resistance (Rsh) and optical transparency. Because commercial PET/ITO substrates are made with slow (~1 m/min) vacuum deposition processes, they tend to be expensive. Therefore, it would be advantageous to develop a high-throughput, R2R compatible, solution-deposition approach for fabricating the TE on PET substrates. While various solution-deposition processes, such as blade coating or slot-die coating, can achieve the desired web speed of > 10 m/min, there is still a need to improve the post-deposition annealing step. One promising post-deposition processing technique is intense-pulsed-light processing, also known as photonic curing. Photonic curing delivers short (0.01 – 100 ms) pulses of broadband (200 – 1500 nm) light from a xenon flash lamp to the samples. Any materials in the sample stack that absorb light will convert the impinging light pulse into heat within the sample, which drives changes in the sample (calcination, phase change, crystallization, etc.). Photonic curing has three main advantages over thermal annealing: 1. Faster processing speed (milliseconds or seconds). 2. Compatibility with plastic substrates. 3. Smaller physical footprint and less wasted energy. Since the light pulses are on for a short time, the intensity can be high while the total energy delivered to the sample is low, minimizing damages to the plastic substrates. In this work, a hybrid TE material is fabricated on PET substrates using photonic curing. The hybrid TE material contains a layer of silver nanowires (AgNWs) and a layer of metal-oxide (InOx, ITO, IZO, etc.). The AgNWs increase the light absorbed by the film during the photonic curing process, which leads to higher processing temperatures, possibly improving the conversion of the metal-oxide layer. The AgNWs also enhance the electrical conductivity of the final TE layer after photonic curing. A AgNW and metal-oxide bilayer is formed by spin coating each solution onto the PET substrate sequentially followed by a single photonic curing process. We use average optical transmittance (Tavg) from 400 to 700 nm and average Rsh to evaluate the TE performance. The following photonic curing parameters are varied to optimize Tavg (maximize) and Rsh (minimize): Pulse voltage, pulse envelope, number of micro-pulses, duty cycle, number of pulses, and pulse repetition rate. Preliminarily, we also observe a significant impact on the TE properties by the volume of AgNW deposited during the spin coating deposition step. Using dispense volumes of 80 µL and 20 µL, we achieve samples with Tavg = 73%, Rsh = 19 Ω/sq, and roughness = 9 nm, and Tavg = 83%, Rsh = 58 Ω/sq, and roughness = 5.6 nm, respectively, after photonic curing.

14 SOLAR ENERGY↗

Extended x-ray emission times of clusters in intense x-ray pulses

Novel experimental spectroscopic and imaging techniques have been developed to exploit x-ray free-electron laser (XFEL) for studying structure and dynamic of non-periodic entities at atomic spatial resolution and femtosecond timescales.Recently, intensity correlation of x-ray fluorescence, based on the principle introduced by Hanbury Brown and Twiss [R. Hanbury Brown and R. Q. Twiss, Nature (London) 177, 27 (1956)], has been proposed for high-resolution imaging of a three-dimensional arrangement of atoms. To explore the applicability of this fluorescence approach, we theoretically investigate fluorescence dynamics of nonperiodic systems subject to x-ray free electron laser (XFEL) pulses over a range of fluences from the linear to nonlinear x-ray absorption regimes as a function of system size, from a single atom to a cluster of 149 171 atoms. Fluorescence dynamics in the nonlinear x-ray regime differs from that in the weak x-ray field in that intense x-ray pulses interrupt the fluorescence dynamics by multiphoton absorption creating a dense electron environment within the sample on a femtosecond timescale. In large systems, the presence of both recombination and photoionization pathways gives rise to an enhanced Kα and Kα h emission yield and an extended emission time beyond the lifetime of the core-excited states. Our analysis suggests that, in an intense x-ray pulse, the Kα h emission line can be a good candidate for fluorescence imaging as it has a higher yield and an emission time that is short relative to the x-ray-induced lattice distortion time.

74 ATOMIC AND MOLECULAR PHYSICS↗

High-Resolution Measurement of Soil Thermal Properties and Moisture Content Using a Novel Heated Fiber Optics Approach

Hydrological parameters are scale dependent. Efficient monitoring techniques capable of measuring hydrological parameters, such as soil moisture content (θ), over a wide range of spatial scales are essential for understanding the complexity of water and energy movement across the landscape. Techniques to measure θ over spatial scales in the range from centimeters to thousands of meters, however, are sorely lacking. Recent improvements in the distributed temperature sensing (DTS) technology supported the development of novel techniques to fill that gap. However, improvements in the accuracy and applicability of DTS techniques are still needed. This study investigates the possibility of improving the accuracy of the fiber optics dual-probe heat-pulse (FO-DPHP) DTS technique by using a new design to maintain the spacing between the FO-DPHP probes and by introducing a novel data interpretation approach. The accuracy of the novel FO-DPHP design was tested at different θ in a sand column experiment. The FO-DPHP measurements obtained using traditional and novel data interpretation approaches were compared against independent measurements from several calibrated soil water content (EC5) sensors. Monte-Carlo analyses were also performed to assess the impact of DTS measurement errors on the accuracy achieved using the data interpretation approaches. The novel design and data interpretation approach allowed for accurate measurements of soil thermal properties and θ without the need to perform a hard-to-achieve soil-specific calibration. Measured θ had mean errors and standard deviations <0.03 and <0.01 m 3 m -3 , respectively, for moisture conditions ranging from dry to near saturation. The standard deviation in the measured heat capacity was <0.01 MJ m -3 K -1 .

42 ENGINEERING↗

Generation of few-cycle pulses in media with alternating sign of effective cubic nonlinearity

An original technique is developed for spectral broadening of femtosecond pulses with compensation for the nonlinear spatial phase during the propagation through nonlinear media with effective cubic nonlinearity of different signs. It was shown that in the region of 1.5 μm, the proposed scheme with BBO crystals at the first stage and NaCl at the second stage allows, using chirped mirrors, the formation of few-cycle pulses of about 7 fs duration with a small B-integral. The possibility of focusing of pulses compressed in the proposed scheme with a large Strehl ratio is demonstrated. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Renewal: Coherent control of spin states in organic electronics – discovery and investigation of complex room-temperature magnetic quantum excitations

In the course of four funding cycles of this project, its research focused on the exploration and understanding of spin-dependent electronic processes in organic semiconductors. It aimed to investigate the potential of harnessing the spin degree of freedom in organic materials for various applications such as spin electronics, quantum information, sensors, and as well as quantum coherent spin phenomena of charge carrier states in organic semiconductors, with the aim to develop room-temperature-based quantum applications. Specifically, the project aimed to: Apply new diagnostic tools, i.e. spin spectroscopy techniques, for paramagnetic charge carrier states in organic semiconductors, based on coherent control with pulsed electron spin resonance to understand spin relaxation and spin mixing mechanisms in organic semiconductor materials and devices such as OLEDs. Explore the nature of charge carrier spin-coupling and pathways for its manipulation to control the physical behaviors of these materials. This involves investigating spin interactions through materials structure, composition, morphological dependencies, isotopic effects, and externally applied electric and magnetic fields, with the goal to manipulate electrical and optical material properties by adjusting spin-orbit, spin-dipolar, spin-exchange, as well as spin-hyperfine interactions to open up this materials class for new applications. Study spin-dependent charge carrier transport and recombination and how these observables are governed by spin-propagation, especially coherent spin propagation as well as collective spin-effects such as the spin-Dicke effect and resonant multi-photon magnetic dipole transitions. The project utilized pulsed electrically detected magnetic resonance (pEDMR) and pulsed optically detected magnetic resonance (pODMR) techniques over a wide frequency range. These techniques enabled the observation and quantification of various spin-spin coupling types, including spin-exchange, spin-dipolar, hyperfine, and spin-orbit interactions. The project will leverage low- to mid-frequency pEDMR/pODMR facilities and collaboration with the National High Magnetic Field Laboratory.

36 MATERIALS SCIENCE↗