Updated sustainability status of cadmium telluride thin‐film photovoltaic systems and projections

This paper provides a comprehensive assessment of the up-to-date life-cycle sustainability status of cadmium-telluride based photovoltaic (PV) systems. Current production modules (Series 6 and Series 7) are analyzed in terms of their energy performance and environmental footprint and compared with the older series 4 module production and current single-crystalline Silicon (sc-Si) module production. For fixed-tilt systems with Series 6 modules operating under average US irradiation of 1800 kWh/m 2 /year, the global warming potential (GWP) is reduced from 16 g CO 2eq /kWh in Series 4 systems to 10 CO 2 eq /kWh in Series 6 systems. For operation in US-SW irradiation of 2300 kWh/m 2 /year, the GWP is reduced from 11 to 8 CO 2eq /kWh and for 1-axis tracking systems operating in Phoenix, Arizona, with point-of array irradiation of 3051 kWh/m 2 /year the GWP is reduced to 6.5 CO 2eq /kWh. Similar reductions have happened in all environmental indicators. Energy payback times (EPBT) of currently installed systems range from 0.6 years for fixed–tilt ground–mounted installations at average US irradiation at latitude tilt installations to 0.3 years for one-axis trackers at high US-SW irradiation, considering average fossil-fuel dominated electricity grids with fuel to electricity conversion efficiency of 0.3. The resulting energy return on energy investment (EROI) also depends on the conversion efficiency of the electricity grid and on the operation life expectance. For a 30-year operational life and grid conversion efficiency of 0.3, EROI ranges from 50 (at US average irradiation) to 70 for US-SW irradiation. The EROI declines with increased grid conversion efficiency; for CdTe PV operating in south California with grid conversion efficiency of 49%, the EROI is about 50 and is projected to fall to 30 when the state's 2030 target of 80% renewable energy penetration materializes. Material alternatives that show a potential of further reductions in degradation rates and materials for enhanced encapsulation that would enable longer operation lives have also been investigated. A degradation rate of 0.3%/year, which has been verified by accelerated testing, is assumed in 30-year scenarios; this is projected to be reduced to 0.2%/year in the near-term and potentially to 0.1%/year in the longer term. With such low degradation rates and enhanced edge-sealing, modules can last 40- to 50-years. Consequently, all impact indicators will be proportionally reduced while EROI will increase. This detailed LCA was conducted according to ISO standards and IEA PVPS Task 12 guidelines. Furthermore, the study revealed that the choices of system models, methods and temporal system boundaries can significantly impact the results and points out to the need to include assumptions regarding these choices in the “transparency in reporting” requirements listed in the IEA PVPS Task 12 Guidelines.

14 SOLAR ENERGY↗

A unified large language model–based framework for heterogeneous PV image diagnosis

With advances in imaging technologies, modern photovoltaic (PV) systems generate large volumes of heterogeneous image data, including visible, electroluminescence (EL), and infrared (IR) images. Existing PV image analysis models, particularly deep learning approaches, are typically task-specific and lack cross-modality generalization. To address this limitation, this paper proposes an open-source large language model (LLM)–based unified framework for heterogeneous PV image diagnostics. Through task-aware diagnostic prompting, the framework enables analysis of visible, EL, and IR images within a single pipeline, supporting both zero-shot and few-shot inference and binary and multiclass classification. It is compatible with state-of-the-art multimodal LLMs, including ChatGPT, Gemini, Claude, Qwen, and CLIP. The framework is evaluated on PV module condition classification (clean, soiling, snow, hail, and bird droppings) using visible images, cell crack detection using EL images, and hotspot detection using IR images. GPT-5.1 in few-shot mode achieves the best performance, with classification accuracy exceeding 97.3%. Open-source models such as Qwen and CLIP also deliver competitive results on visible images (around 90% accuracy), though their performance is more limited on EL and IR modalities. On the full ELPV dataset, the framework achieves 83.5% zero-shot accuracy, within 2.8% of the supervised CNN baseline, confirming scalability to larger benchmarks. Practical aspects such as reproducibility, response latency, and confidence estimation are systematically analyzed. The framework operates across PV image modalities without modality- or task-specific training, making it well suited as a rapid pre-screening tool to support downstream detailed diagnostics. A benchmark dataset of diverse labeled PV images is also released.

Li, Baojie↗

Nature of innovations affecting photovoltaic system costs

Innovations improve technology costs through various kinds of engineering advancements, including changes to materials choices and device or process designs. Understanding how these innovations relate to cost change can reveal aspects of the process of technology evolution, yet developing such understanding is often not possible with a strictly quantitative approach due to data limitations. In this paper we develop a hybrid quantitative-qualitative framework for relating specific innovations to cost change by using the variables in a quantitative technology cost change model as an organizing principle. We demonstrate this framework by applying it to the cost decline in photovoltaic (PV) systems over the last five decades. This framework generates new understanding of a set of innovations that contributed to PV modules’ sustained cost decline and the more modest trends observed in balance-of-system (BOS) costs. The results show the great diversity of innovations that affected PV costs, drawing on wide-ranging fields of expertise within scientific research and practice. We find that there are differences in the characteristics of innovations that reduced the cost of PV modules compared to innovations influencing BOS costs. Numerous module innovations reduced costs by advancing manufacturing tools and processes that improved material quality. Many BOS innovations reduced costs through a combination of component design changes, integration, automation, digitalization, and standardization. Overall, most innovations in our sample affected PV hardware. However, some also target ‘soft technologies’ such as task durations through innovations like fast-track permitting, which require improved collaboration and process streamlining. This framework also provides insight into the nature of knowledge spillovers between technologies. Both module and BOS hardware innovations show the benefits of PV’s position within an ‘ecosystem’ of continuously advancing technologies in many industries, in particular semiconductors and electronics, and also point to the importance of public institutions for accelerating testing, permitting, and training.

14 SOLAR ENERGY↗

Photovoltaic and Cost Analysis for Winston-Salem, North Carolina

This study assesses the feasibility of solar installations at various sites in Winston-Salem, focusing on factors such as solar resource availability, electricity costs, and rooftop area for photovoltaic systems. The analysis begins by estimating daily energy requirements based on annual electricity use, followed by adjusting for seasonal and operational fluctuations. Using regional solar data from the National Solar Radiation Database (NSRDB), we calculate average peak sun hours to determine effective system sizing. A parametric approach using the System Advisor Model (SAM) refines this sizing process, incorporating a safety margin of 1.2 to address demand peaks. Each PV system is designed to fit available rooftop space, and a coverage threshold of 70% is identified as optimal for maximizing cost savings and sustainability. This threshold allows installations to meet substantial energy demands, supporting energy resilience and enhancing economic returns.

14 SOLAR ENERGY↗

Benefits of the SolarAPP+ Online Permitting Software

The Solar Automated Permit Processing Plus (SolarAPP+) software is an online platform that provides plan review and instantly issues permits for code-compliant residential photovoltaic (PV) systems.

automated permitting↗

Advancing Our Understanding of System Availability through the PV Fleet Performance Data Initiative

The PV Fleet Performance Data Initiative partners with photovoltaic (PV) fleet owners to collect time-series data of PV production data and publishes aggregated anonymized results of system performance metrics. With an extensive dataset drawn from over 2,200 PV systems across the United States, comprising 8.5 GW and 24,000 separate inverter data channels, this initiative aims to ensure that systemic risks in the US PV fleet are detected. The current work explores system availability, revealing a pronounced dependence on time, especially within the initial 6 months of system performance. Following this start-up period, the average system availability stabilizes. Statistical analyses illustrate a median (P5O) monthly availability of 0.991 and a dependence on system size with a negative trend in availability with increasing system size. This finding indicates that larger systems experience lower availability compared to their smaller counterparts.

inverter availability↗

Side-by-Side Comparison of Subhourly Clipping Models

Over the past several years there have been numerous attempts at quantifying the inherent power clipping of inverters due to sub-hourly irradiance variability that is not captured in hourly PV performance models. Different models have been proposed to correct for these clipping losses in PV performance estimates, including matrix lookup models, distribution modeling of the PV power performance within a given hour, and machine learning methods. To date, there have been few comprehensive quantitative comparisons of these inverter clipping correction modeling approaches to evaluate the effectiveness of these approaches in predicting the actual behavior of PV system inverter clipping. In this study, we perform such a comparison, evaluating the Allen and Walker correction loss modeling approaches recently implemented in the System Advisor Model (SAM) against clipping losses modeled with 1-minute climate data. These comparisons were performed across a variety of climate locations and inverter loading ratios to thoroughly analyze the effectiveness of these modeling approaches relative to each other. Results from this analysis reveal that both clipping correction approaches improve annual energy accuracy to within 2% of 1-minute modeled energy yield. The two models predict annual clipping loss more accurately than simple hourly power limit clipping, with the Allen method typically being slightly more accurate at typical ILR values and the Walker method often being slightly more accurate at high ILR values The models can improve accuracy over the status quo clipping approach up to 3 percentage points in systems with ILR of 2.0, showing the importance of this modeling factor in energy yield estimates.

ENERGY PLANNING, POLICY, AND ECONOMY,MATHEMATICS A↗

Dynamic Wind Loading on Compliant, Floating PV Arrays: Cooperative Research and Development (Final Report)

PV panels are subjected to wind loads during normal outdoor operation, where th wind speed, wind direction, panel angle, and array layout play a large role in the overall loading magnitude. For floating PV systems, where panels are installed on floating rafts, these forces can lead to a dynamic displacement of the raft and mounted PV hardware. The Contractor and Participant will perform fluid-structure interaction simulations of this phenomenon for a variety of wind speeds, directions, and panel angles to characterize these forces and help design mooring/tethering lines to resist and anchor raft movement.

14 SOLAR ENERGY↗

Photovoltaics as a terrestrial energy source. Volume 1: An introduction

Photovoltaic (PV) systems were examined their potential for terrestrial application and future development. Photovoltaic technology, existing and potential photovoltaic applications, and the National Photovoltaics Program are reviewed. The competitive environment for this electrical source, affected by the presence or absence of utility supplied power is evaluated in term of systems prices. The roles of technological breakthroughs, directed research and technology development, learning curves, and commercial demonstrations in the National Program are discussed. The potential for photovoltaics to displace oil consumption is examined, as are the potential benefits of employing PV in either central-station or non-utility owned, small, distributed systems.

Smith, J. L.↗

Standardized nomenclature for photovoltaic connectors

Photovoltaic (PV) systems rely on discrete connectors for the efficient and safe flow of power from module to module and from strings to combiner boxes and inverters. Despite their functional importance, no common nomenclature for PV connectors currently exists, resulting in confusion and miscommunication. Misunderstood terms like "MC4 compatible", "cross-mating", "intermating", "female", and "male" can lead to installation and maintenance errors and compromise system reliability. We believe a standardized terminology will reduce confusion, help support installation best practices, aid in maintenance and repair, inform next-generation designs, and provide a technical basis for improved codes and standards. To that end, we are proposing a standardized glossary for 4 mm PV connectors (the most common type of connector used in PV applications) based on, and validated by, a Sandia National Laboratories' investigation that included the following sources: 1) a comprehensive review of official documents from 20 connector manufacturers, including schematics, datasheets, installation manuals, and catalogs, as well as relevant patents; 2) two rounds of surveys distributed to stakeholders, including connector manufacturers, engineers, asset owners, test labs, and researchers; and 3) visual examination of 25 different models of 4 mm single-pole DC PV connectors to document variations in design and functionality. This work provides a foundation for establishing a clear and consistent terminology for PV connectors that will in turn enable progress toward greater reliability and collaboration across the industry.

14 SOLAR ENERGY↗

Automated analysis of unlabeled PV data with Solar Data Tools software: Overview and feature updates

Distributed rooftop PV systems: ubiquitous, yet commonly have unlabeled data Difficult or impossible to form a performance index We developed Solar Data Tools (SDT), an open-source Python library for analyzing PV power (and irradiance) time-series data SDT enables analysis of unlabeled PV data—no model, no meteorological data, no performance index required Takes a statistical signal processing approach Data processing steps are largely pre-defined and automatic regardless of system type—from utility tracking systems to multi-pitch rooftop systems

Meyers-Im, Bennet E↗

Rapid characterization and failure analysis of 6276 rooftop-harvested photovoltaic connectors

Photovoltaic (PV) connectors, which link modules in series and connect PV strings in parallel, have increasingly been recognized as a primary contributor to PV system failures and a source of numerous fire incidents. However, publicly available data on the rates and types of connector failures are scarce, primarily due to the proprietary nature of the information and the need for comprehensive analysis. This study represents the first large-scale investigation of harvested PV connectors, drawing from a dataset of 6276 connectors from residential rooftop solar systems across the United States. The outcome of this work is twofold: 1) we have established a rapid characterization method for large populations of harvested connectors, incorporating visual inspection, resistance measurements, and X-ray imaging; and 2) the analysis made possible by our rapid-processing method has revealed, for a population of connector models provided by a single rooftop installer, failure statistics and insights for various connector makes and models, installation practices, operating currents, and internal component displacements. This research identifies common failure modes that could be considered in future connector designs standards, and operations and maintenance practices, to ultimately improve the reliability of this vital component of PV infrastructure.

MC4↗

pvplr-python: Python package implementation of PVplr for Performance Loss Rate (PLR) analysis

Due to software fragmentation, PV system modeling teams can be limited to language specific packages, preventing cross-sectional analysis of different modeling techniques and workflows. To this end, PVplr, a popular PV performance modeling R software package, has been ported to the Python programming language. To verify and test the robustness of the port, NSRDB data has been used to simulated PV installations at native resolution (~2 million Sites), with a variety of degradation rates, degradation patterns, and modules. Performance Ratios were calculated using the ported functions from pvplr-python and compared against Rdtools YoY values. Due to the complicated nature of degradation, a new metric has been proposed to quantify the performance loss of a system. The cumulative production loss, is the total amount of energy lost due to the degrading performance of the system. Cumulative production loss alleviates the problems with fitting linear functions to non-linear degradation. Cumulative Production loss was shown to better estimate the total lost revenue for non-linear degradation patterns. $XbX + UTC$ was found to most accurately predict the total lost revenue in simulated systems.

Kumar, Suraj↗

ACTS for distance education in developing countries

The need for electrical energy supply in the rural communities of developing countries has been well documented. Equally well known is the potential for photovoltaic in cost effectively meeting this need. A major impediment to fulfilling the need is the lack of indigenous personnel with a knowledgeof photovoltaic systems, and the associated infrastructure required to implement project. Various delivery schemes for providing the needed training to developing countries personnel have been investigated. Various train methods and programs that have been employed to remedy the problem have had significant drawbacks in terms of cost, consistency, impact, reach, and sustainability. The hypothesis to be tested in this project posits that satellite-based distance education using ACTS technologies can overcome these impediments. The purpose of the project is to investigate the applicability of the ACTS satellite in providing distance education in photovoltaic systems to developing countries and rural communities. An evaluation of the cost effectiveness of using ACTS unique technologies to overcome identified problems shall be done. The limitations of ACTS in surmounting distance education problems in developing countries shall be investigated. This project will, furthermore, provide training to Savannah State College faculty in photovoltaic (PV) systems and in distance education configurations and models. It will also produce training materials adequate for use in PV training programs via distance education. Savannah State College will, as a consequence become well equipped to play a leading role in the training of minority populations in photovoltaic systems and other renewables through its Center for Advanced Water Technology and Energy Systems. This communication provides the project outline including the specific issues that will be investigated during the project. Also presented i the project design which covers the participations of the various components of a network of institutions that is formed for optimal project execution. The expected results and project output, including plans for potential leverages and linkages to be derived, are also discussed. Finally, we point out possible extensions from this project and other related projects that could be initiated based on the experiences gained from the project.

Kalu, A↗

Community Center and Administration Solar PV Project

The Tribe installed two (2) roof mounted solar PV systems with a total production of approximately 146 kW on the Paskenta Band of Nomlaki Indians’ Community Center in Corning, CA. One of the two solar PV arrays provided 90% of the Community Center’s energy, while the second array provided nearly 100% of the adjacent administration building’s energy.

14 SOLAR ENERGY↗

Simplifying Geospatial Workflows with GeoGridFusion

Growing demands to understand PV deployment and reliability across an expanding range of climates, along with increasing computational power, are driving the need for simplified computing tools that support large-scale analysis and geospatial workflows. While existing open-source libraries and PV system modeling tools offer extensive collections of empirical and physical models, they often lack the ability to scale to large geospatial datasets. The tool presented here, GeoGridFusion, enables PV modelers to store and utilize gridded geospatial data from sources such as NSRDB, PVGIS, and others. GeoGridFusion harmonizes diverse datasets, taxonomies, and nomenclatures, and includes utilities that support intuitive geospatial area selection.

14 SOLAR ENERGY↗

Power conditioning subsystems for photovoltaic central-station power plants - Technology and performance

Central-Station (CS) Photovoltaic (PV) systems have the potential of economically displacing significant amounts of centrally generated electricity. However, the technical viability and, to some extent, the economic viability of central-station PV generation technology will depend upon the availability of large power conditioners that are efficient, safe, reliable, and economical. This paper is an overview of the technical and cost requirements that must be met to develop economically viable power conditioning subsystems (PCS) for central-station power plants. The paper also examines various already commercially available PCS hardware that may be suitable for use in today's central PV power stations.

Krauthamer, S.↗

The Hard Life of Floatovoltaics: Modeling Wind-Driven Oscillations of Floating Solar Panels

Modern, thin photovoltaic (PV) panels for solar power are susceptible to high stress loads in windy conditions. Manufacturers are eager to determine optimal installation practices to reduce these loads, including in the relatively new practice of installing PV on floating structures located on artificial and natural lakes. As part of our effort to develop simulation capabilities for stress on such floating PV systems, we here present our combined model-simulation approach, which simulates the dynamic wind loading and uses modeled elements to capture both the hydrodynamic and mooring-line forces. We discuss the forces important for our model and the challenges inherent in our simulation. Of particular interest is our model of the hysteresis response displayed by the attached mooring lines, which are engineered to damp motion and oscillation of the floating panel system. We validate our approach against the benchmark problem of vortex-induced vibration of a cylinder, which is driven by the same dynamic forces present in floating PV panels.

floating↗