Decentralized Interleaving of Cascaded H-Bridge Multi-Level Converters

This document proposes a simple method to decentralize the interleaving for cascaded H bridge (CHB) converters. In the proposed approach, a single signal sent from the Central controller (CC) to Local Controllers (LC) contains information about the desired pulse width and is synchronized with respect to other LC. While centralized controllers need individual signals for each of the CHB modules, the proposed method requires a single signal per phase which decreases the number of PWM channels needed. A detailed explanation of the proposed method is presented. Experimental results are presented that show the interleaving of two CHB modules for an example DC to AC application.

Montes, Oscar Andres↗

Analysis of Double-Output CLL Resonant Converter for All-Electric UAV Applications

This paper presents a double-output resonant converter with high-frequency isolation for unmanned aerial vehicle (UAV) applications. The proposed topology is developed by using a full-bridge resonant inverter and double-output half-bridge active rectifiers. For the control system, a phase-shifted pulse width modulation (PS-PWM) method is utilized to adjusts the power flow among the output rectifiers in a wide voltage range regulation with a central control. The theoretical analysis of the converter is explored using the system model under different load conditions with constant frequency. The proposed system is validated with experimental results using 60 V input source and generating 0 - 100 V in each output at a full power of 500 W with 96% maximum efficiency in the laboratory experimental setup.

Asa, Erdem↗

Multi-Core Microcontroller Hardware In the Loop System for Electric Machine Control

Hardware in the Loop (HIL) is a simulation technique used to reduce the software development cycle and test control systems in a non-destructive environment. This work describes a cost effective HIL simulator on a dual core microcontroller in which one core acts as a controller and the other emulates the system under control. The emulator runs one step per Pulse Width Modulation (PWM) period in real time. To handle the computational burden and prioritize execution of simulation and control tasks, an interrupt-based software architecture with task prioritization has been developed. As a demonstration, the HIL has been implemented on a Texas Instruments TMS320F28379D dual core microcontroller, which emulates a Permanent Magnet Synchronous Machine (PMSM) with resolver feedback. Hardware peripherals are developed and tested concurrently with the control system, providing higher confidence in the software. By using the peripherals in the HIL development, the controller exercises either the HIL emulation or a pin compatible PMSM testbench. To quantify performance and validate the processor based emulator, the HIL results are compared to the preexisting testbench for accuracy benchmarking at no-load and under load for a range of operating points.

33 ADVANCED PROPULSION SYSTEMS↗

Strengthening Cybersecurity for Industrial Control Systems: Innovations in Protecting PLC-Based Infrastructure

In this paper, we propose two new approaches aimed at enhancing the security of industrial control systems (ICS) that utilize programmable logic controllers (PLCs) for the control of critical processes. The first approach involves the addition of a unique digital watermark to the PWM control that adjusts the motor speed to control the critical process. This enables efficient detection and identification of any unauthorized modifications to the sensor signals responsible for controlling the plant. The second approach focuses on monitoring the input current (i.e power) drawn by the PLC during the execution of critical process control tasks. Malicious intrusions to change the PLC parameters and/or unauthorized firmware updates can be rapidly detected. Both approaches demonstrate a substantial improvement in the security of ICS, effectively safeguarding against potential cyber-attacks. Experimental results from a laboratory scale water tank level controlled via PLC showcases rapid intrusion detection capabilities.

Huang, Peng-Hao↗

A Comparison of Battery Charge Controller Technologies for Wave Energy Converters

Wave energy is a uniquely challenging field for electrical system designers. High peak and low average power potential with a constantly varying energy input is difficult to harness and control through conventional means. To power the blue economy, low-powered wave energy converters (WECs) need batteries for energy storage. Safely and effectively charging batteries from waves requires a charge controller to properly monitor and control voltage and current going to the battery. Currently, off-the-shelf charge controllers exist for other renewable generation such as wind, hydro, and solar. Two topologies were validated: a buck converter and a pulse width modulation (PWM) charge controller. Using an in-lab dry testbed, wave energy power inputs were simulated to properly validate the effectiveness of existing charge controller technologies, identifying the shortcomings and improvements needed to effectively harness wave energy.

battery storage↗

A Universal Controller for Grid-Forming Inverters in Microgrid during Islanding for Low Transient Current

This paper presents a universal controller to reduce the transient current during islanding of microgrid. In the proposed universal controller, two sets of semi-parallel paths are formed, where one set produces voltage and phase-angle references for the grid-following (GFL) mode, and the other set produces the voltage and phase-angle references for the grid-forming (GFM) mode of operation for the inverters. Herein, the controller enables an inverter to universally operate in GFL and GFM mode, whereas, only one set of voltage and phase-angle reference is engaged for PWM signal generation. When the microgrid is disconnected from the grid, the universal controller switches the voltage and phase-angle references from GFL to GFM mode. The proposed controller ensures lower transient current by keeping the two sets of semi-parallel paths synchronized throughout the operation of the inverter and enabling seamless transition between the modes. The proposed controller is verified through hardware experiments under different scenarios in a laboratory scale microgrid for inverters transitioning from GFL to GFM mode after islanding.

Sadeque, Fahmid↗

Design Considerations of DC/DC Regulator for High-Power Dynamic Wireless Charging Systems

Due to fast fluctuating input voltage, dynamic wireless charging requires a post-regulator stage for battery charging control and management. This regulator stage has a high requirement on efficiency, size as well as control performance to ensure tight regulation and fast trainset. This paper addresses the control challenges by modeling the system and designing the compensator with input voltage feedforward control. In addition, high resolution PWM is implemented to improve transient performance and current balancing among the phases. Experimental results prove the effectiveness of the proposed schemes and validates 180 kW closed-loop 4-phase operation at 99% efficiency.

Xue, Lincoln↗

Dynamic P-Q Capability and Abnormal Operation Analysis of a Wind Turbine with Doubly-Fed Induction Generator

After several accidents occurred in wind farms in the United States and around the world, the subsynchronous oscillation (SSO) issues in grid-connected wind farms have gained serious attention. Particularly, these issues have caused significant challenges to wind turbines with a doubly fed induction generator (DFIG) because it is connected to the grid via both its stator and rotor paths. Traditionally, a P-Q capability chart is utilized to assure the safe operation boundary for a synchronous generator. But the energy conversion characteristics of a DFIG wind turbine are completely different. A critical factor to affect the reliable operation of a DFIG wind turbine is the rated current and pulse-width modulation (PWM) saturation constraints of its power converters. These constraint conditions can be affected by the wind turbine rotating speed and grid conditions. However, a detailed study of DFIG P-Q capability from these perspectives has not been conducted, which has hindered adequate understanding of many abnormal wind turbine operations reported in the literature and the development of advanced control technologies to overcome the challenges. The proposed study in this paper considers vector control implementation to DFIG power electronic converters in the dq reference frame, and the models and algorithms developed for the P-Q capability study have addressed specific DFIG power converter constraints that are different from those of a traditional synchronous generator. The paper especially focuses on exploring the dynamic natures of DFIG P-Q capability under uncertain and variable conditions to explore the root causes of many abnormal operations of DFIG wind turbines reported in the literature. The proposed study is validated through an electromagnetic transient simulation model of a grid-connected DFIG wind turbine. The proposed study has the potential to lead to the development of new DFIG control technologies that can help overcome the challenges for many abnormal operations of DFIG wind turbines.

17 WIND ENERGY↗

Analysis and Control of a Three-Port Converter with High-Frequency AC Link for Hybrid Unmanned/Autonomous Aerial Vehicles

In this study, a three-port resonant converter with a high-frequency isolation link for hybrid unmanned/autonomous aerial vehicle (UAV/AAV) applications is analyzed. The rectified engine-generator set output supplies the first input ports while the other is connected to a battery energy storage system. Input ports consist of half-bridge high-frequency inverters, whereas output port utilizes a semi-bridgeless active rectifier. This rectifier is formed by replacing rectifier low-side diodes with active switching devices. A phase-shift duty-cycle control is implemented for switching signals to regulate the power share and flow between ports. The proposed control system implemented achieves zero voltage switching (ZVS), reduces switching losses, and minimum current flow optimization ensures regulation in a wide range of output power. Compared to the existing bidirectional pulse width modulation (PWM) converters, the proposed system decreases the number of power conversion stages and provides centralized control without needing communications between the ports. The proposed control technique operating in closed-loop control achieves the power flow between ports under various load conditions. Finally, theoretical analysis demonstrates the proposed converter’s viability and laboratory experimental validations at 500 W full power.

33 ADVANCED PROPULSION SYSTEMS↗

A High-Current Pulsed Prototype Power Supply

The Accelerator Controls Operations Research Network (ACORN) project aims to modernize the accelerator control system and replace aging power supplies at Fermilab. As part of this effort, outdated RF ferrite bias power supplies will be redesigned. These power supplies are essential for tuning the resonant frequency of RF cavities by delivering programmable current outputs of up to 2500 A and voltages ranging from −10 V to +35 V. They operate at a repetition rate of 15 Hz in the Booster ring, and 1 Hz at the Main Injector ring. The power supplies utilize a bank of transistors in the linear region, connected in parallel with the load, to actively regulate the output current from a 12-pulse SCR bridge. To support this upgrade, a new bias power supply topology was developed as proof of concept. The design utilizes an IGBT Hbridge operating in Pulse Width Modulation (PWM) mode, controlled by a microcontroller. A prototype, constructed using spare components, successfully delivered an output current of 500 A at a repetition rate of 15 Hz during initial testing. The circuit's bandwidth was measured at 480 Hz, highlighting opportunities for further optimization in the controller design to achieve the target bandwidth of 2 kHz.

Bullman, Austin [ORNL]↗

Operation of Dual-T-Type Modular Multilevel Converter for Uninterrupted Power Supply Under Bridge Failures

Dual-T-type modular multilevel converter (DTMMC) is an alternative to the existing uninterrupted power supply (UPS) due to its advantage in flexible leg reusing, multiple power ports, and high operating efficiency. Here, in this article, a DTMMC-UPS, which has series configurations on both input/output ac sides, obtains high-voltage grid/load accessing interfaces is presented. In the described system, the fact that copies of T-type legs are employed makes semiconductor failure common to happen. Moreover, both the coupling between rectifier and inverter conversions and the confliction between intercell and inner-cell voltage balancing make fault-tolerant control a tough issue. In this article, the switch fault types are first clarified and diagnosed by the different impacts on normal operation. An improved voltage vector modulation is then deduced to facilitate the planning of proper primary switching patterns, to achieve rectifier side normal operation. The secondary alternated level-shifted pulsed-width modulation (LS-PWM) is also modified to achieve inverter side normal operation. The experiment results are supplied to verify the validity of the modulation-coordinated fault toleration strategy.

42 ENGINEERING↗

Fast Neutron Irradiation of a Multichannel JFET-Based Optical Encoder

Modern electrical components are susceptible to damage from high levels of radiation and extreme temperatures found near reactors in terrestrial nuclear power plants and in aerospace applications. Radiation-hardened electronics are being developed, largely for the aerospace industry, but they sometimes rely on application-specific, small-batch semiconductor fabrication processes. These processes tend to be prohibitively expensive to develop and maintain outside major industrial facilities or governmental agencies. Recently, commercially available, nonradiation-rated junction-gate field-effect transistors (JFETs) were shown to maintain their functionality at gamma doses exceeding 1 MGy, suggesting that nonrated, commercially available electrical components could be used to develop systems that are tolerant to ionizing radiation. However, gamma ray survival is not indicative of neutron dose survival, and few studies characterize JFETs under neutron irradiation. To address this knowledge gap, a JFET-based analog multiplexer and optical pulsewidth modulation (PWM) encoder was developed and irradiated using a 252 Cf source to 1.6×10 13 n/cm 2 . The multiplexed optical encoder (MOE) system maintained functionality throughout testing and showed little evidence of radiation effects. These results indicate that circuitry tolerant to fast neutron damage can be developed using low-cost, nonradiation-rated, commercially available JFETs, which could provide a lower production cost alternative to specialized semiconductor processes when designing and building electronics better able to survive neutron irradiation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Common-Mode Circulating Current Control of Paralleled Interleaved Three-Phase Two-Level Voltage-Source Converters With Discontinuous Space-Vector Modulation

This paper presents a control method to limit the common-mode (CM) circulating current between paralleled three-phase two-level voltage-source converters (VSCs) with discontinuous space-vector pulsewidth modulation (DPWM) and interleaved switching cycles. This CM circulating current can be separated into two separate components based on their frequency; the high-frequency component, close to the switching frequency, can be effectively limited by means of passive components; the low-frequency component, close to the fundamental frequency, embodies the jumping CM circulating current observed in parallel VSCs. This is the main reason why it is usually recommended not to implement discontinuous and interleaving PWM together. The origin of this low-frequency circulating current is analyzed in detail, and based on this, a method to eliminate its presence is proposed by impeding the simultaneous use of different zero vectors between the converters. This control method only requires six additional switching actions per line cycle, presenting a minimum impact on the converter thermal design. The analysis and the feasibility of the control method are verified by simulation and experimental results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Novel Phase-Shift Control of Semibridgeless Active Rectifier for Wireless Power Transfer

We investigated a novel phase-shift control of a semibridgeless active rectifier (S-BAR) in order to utilize the S-BAR in wireless energy transfer applications. The standard receiver-side rectifier topology is developed by replacing rectifier lower diodes with synchronous switches controlled by a phase-shifted PWM signal. Moreover, theoretical and simulation results showthat with the proposed control technique, the output quantities can be regulated without communication between the receiver and transmitter. In order to confirm the performance of the proposed converter and control, experimental results are provided using 8-, 15-, and 23-cm air gap coreless transformer which has dimension of 76 cm x 76 cm, with 120-V input and the output power range of 0 to 1kW with a maximum efficiency of 94.4%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

System Modeling and Simulation of In-Stream Hydrokinetic Turbines for Power Management and Control

Electricity generation from moving currents without using dams (i.e., in-stream hydrokinetic electricity) has the potential to introduce multiple GW of renewable power to U.S. grids. Here this study evaluates a control system designed to regulate the generator rotor rate (rpm) to improve power production from in-stream hydrokinetic turbines. The control algorithm is evaluated using numerical models of both a rigidly mounted tidal turbine (TT) and a moored ocean current turbine (OCT) coupled to an induction electric machine model. The moored simulation utilizes an innovative approach for coupling a multiple degrees-of-freedom (DOF) nonlinear hydrodynamic/mechanical turbine model with a nonlinear electromechanical generator model. Based on the turbine torque-speed characteristic, as well as the asynchronous machine features, a proportional–integral (PI) controller is used to generate a correction term for the frequency of the three-phase sinusoidal voltages that are supplied to the asynchronous generator. The speed control of the induction generator through the supply frequency is accomplished by a simplified voltage source inverter (VSI). The simplified VSI consists of control voltage sources (CVSs), while the comparison with a real VSI using diodes and transistors, which are controlled by pulse width modulation (PWM) technique, is also presented. Simulations are used to evaluate the developed algorithms showing that rpm fluctuations are around 0.02 for a tidal turbine operating in a wave field with a 6 m significant wave height and around 0.005 for a moored ocean current turbine operating in a wave field with a 2 m significant wave height.