Search NASA⌕ Search

SEARCH · Search NASA

Results for “Physics, Optics and optical instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

High-magnification Faraday rotation imaging and analysis of X-pinch implosion dynamics

An X-pinch load driven by an intense current pulse (>100 kA in ~100 ns) can result in the formation of a small radius, runaway compressional micro-pinch. A micro-pinch is characterized by a hot (>1 keV), current-driven (>100 kA), high-density plasma column (near solid density) with a small neck diameter (1–10 µm), a short axial extent (<1 mm), and a short duration (≲1 ns). With material pressures often well into the multi-Mbar regime, a micro-pinch plasma often radiates an intense, sub-ns burst of sub-keV to multi-keV x rays. A low-density coronal plasma immediately surrounding the dense plasma neck could potentially shunt current away from the neck and thus reduce the magnetic drive pressure applied to the neck. Here, to study the current distribution in the coronal plasma, a Faraday rotation imaging diagnostic (1064 nm) capable of producing simultaneous high-magnification polarimetric and interferometric images has been developed for the MAIZE facility at the University of Michigan. Designed with a variable magnification (1–10×), this diagnostic achieves a spatial resolution of ~35 µm, which is useful for resolving the ~100-μm-scale coronal plasma immediately surrounding the dense core. This system has now been used on a reduced-output MAIZE (100–200 kA, 150 ns) to assess the radial distribution of drive current immediately surrounding the dense micro-pinch neck. The total current enclosed was found to increase as a function of radius, r, from a value of ≈ 50 ± 25 kA at r ≈ 140 µm (at the edge of the dense neck) to a maximal value of ≈150 ± 75 kA for r ≥ 225 µm. This corresponds to a peak magnetic drive pressure of ≈75 ± 50 kbar at r ≈ 225 µm. The limitations of these measurements are discussed in the paper.

47 OTHER INSTRUMENTATION↗

Active Cancellation of Servo-Induced Noise on Stabilized Lasers via Feedforward

Many precision laser applications require active frequency stabilization. However, such stabilization loops operate by pushing noise to frequencies outside their bandwidth, leading to large “servo bumps” that can have deleterious effects for certain applications. The prevailing approach to filtering this noise is to pass the laser through a high-finesse optical cavity, which places constraints on the system design. Here, we propose and demonstrate a different approach where a frequency error signal is derived from a beat note between the laser and the light that passes through the reference cavity. The phase noise derived from this beat note is fed forward to an electro-optic modulator after the laser, carefully accounting for relative delay, for real-time frequency correction. With a hertz-line-width laser, we show ≳20 dB noise suppression at the peak of the servo bump (approximately 250 kHz) and a noise-suppression bandwidth of approximately 5 MHz—well beyond the servo bump. By simulating the Rabi dynamics of a two-level atom with our measured data, we demonstrate substantial improvements to the pulse fidelity over a wide range of Rabi frequencies. Here, our approach offers a simple and versatile method for obtaining a clean spectrum of a narrow-line-width laser, as required in many emerging applications of cold atoms, and is readily compatible with commercial systems that may even include wavelength conversion.

47 OTHER INSTRUMENTATION↗

Replacing photomultiplier tubes with silicon photomultipliers for nuclear safeguards applications

Photomultiplier tubes (PMTs) have been used for decades as the default light detection technology for scintillator-based radiation monitors. PMTs come with a handful of disadvantages, however, including large volume usage, fragility, high-voltage requirements, and susceptibility to magnetic fields. Arrays of silicon photomultipliers (SiPMs) are a possible alternative to PMTs providing similar performance while offering improvements in the areas listed. We focus on straightforward “drop-in replacement” evaluations by imposing a single channel output of the SiPM signal and a backend electronics data acquisition and analysis routine identical to that used for PMTs. In the realm of nuclear safeguards, the primary performance metric for gamma spectroscopy is detector resolution, and for neutron detection it is pulse shape discrimination (PSD) to separate neutron and gamma signals. In this work we present the results of replacing a PMT with a 2” x 2” SiPM array mounted, in turn, to the same 2” x 2” cylindrical sodium iodide (NaI) crystal. The ultimate comparison for this gamma spectrometry is confirmation of uranium enrichment standards, ranging from depleted uranium to 93% highly enriched uranium (HEU), by analyzing the resulting spectra with both a simple integral scaling in key energy regions of the spectrum, as well as with the NaIGEM software package. In addition to the gamma spectroscopy work, we will present the latest results on comparing the PSD capabilities of a 4” x 4” SiPM array to a 5” PMT. As with the gamma spectroscopy evaluations, the light detectors are mounted in turn to the same liter-scale organic scintillators. This neutron-focused work includes evaluation of prototype SiPM readout boards with a single output signal summed over 256 individual SiPM pixels, and evident tradeoffs between PSD capability and fast response.

Engineering - Instrumentation related to nuclear s↗

Topological Singularity Induced Chiral Kohn Anomaly in a Weyl Semimetal

The electron-phonon interaction (EPI) is instrumental in a wide variety of phenomena in solid-state physics, such as electrical resistivity in metals, carrier mobility, optical transition, and polaron effects in semiconductors, lifetime of hot carriers, transition temperature in BCS superconductors, and even spin relaxation in diamond nitrogen-vacancy centers for quantum information processing. However, due to the weak EPI strength, most phenomena have focused on electronic properties rather than on phonon properties. One prominent exception is the Kohn anomaly, where phonon softening can emerge when the phonon wave vector nests the Fermi surface of metals. In this paper, we report a new class of Kohn anomaly in a topological Weyl semimetal (WSM), predicted by field-theoretical calculations, and experimentally observed through inelastic x-ray and neutron scattering on WSM tantalum phosphide. Compared to the conventional Kohn anomaly, the Fermi surface in a WSM exhibits multiple topological singularities of Weyl nodes, leading to a distinct nesting condition with chiral selection, a power-law divergence, and non-negligible dynamical effects. Our work brings the concept of the Kohn anomaly into WSMs and sheds light on elucidating the EPI mechanism in emergent topological materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Calibration of the sub-aperture backscatter system on OMEGA EP

The sub-aperture backscatter (SABS) diagnostic on the OMEGA EP Laser System is a diagnostic that is used to measure the backscattered and sidescattered light during laser–plasma interaction experiments that are relevant to high-energy-density physics and inertial confinement fusion. The diagnostic collects stimulated Brillouin scattering (SBS) UV light at around 351 nm and stimulated Raman scattering (SRS) in the visible-light regime in the 420–720-nm-wavelength range and provides spectrally and temporally resolved information. Five 1-in. light collectors, composed of a lens, ground glass diffuser, and coupling into a 300-μm fiber, are positioned behind the last steering mirror on one of the four beamlines to catch a portion of the beam cross section (~1.5%) of the emission that is scattered into the beamline. The SRS light is collected in two light collectors, combined, and transported via graded index fibers to a streaked spectrometer. The SABS-SRS streak spectrometer has a temporal and spectral resolution of 100 ps and 1 nm, respectively. Three other light collectors collect, combine, and transport the SBS signal to a Hamamatsu high-voltage photodiode, where an oscilloscope digitizes the data, providing a time resolution of better than 1 ns. To obtain an absolute energy calibration of SRS measurements, light signals of known energy and wavelength were injected into the light collectors one at a time. The resulting counts on the streak camera charge-coupled device for SRS are then correlated with the incident fluence of scattered light at the light collector in order to allow a quantitative assessment of streak camera sensitivity to determine the energy of the scattered light during experiments. The measurements were performed in situ from the light collectors to the detectors. Other offline measurements provided the transmission of the optics between the target chamber center and the light collectors.

47 OTHER INSTRUMENTATION↗

Design of a correlation reflectometer radiometer diagnostic and measurements of the electron density–temperature cross-phase angle in the H-mode pedestal with small edge localized modes at ASDEX Upgrade

This work presents the hardware design and first results from a newly commissioned correlation reflectometer radiometer diagnostic that measures the cross-phase angle between electron density and temperature fluctuations in ASDEX Upgrade plasmas. This diagnostic employs cross correlations between signals measured by a tunable, continuous wave, perpendicular incidence, fluctuation reflectometer, and a 24-channel radiometer sharing the same line of sight. Novel measurements in the pedestal of a helium H-mode plasma with small edge localized modes show changes in the cross-phase angle between the electron density and temperature fluctuations from ∼90° to 120°, suggesting changes in the properties of the turbulence driving transport in the plasma edge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental study of multiple-orientation muon tomography with image optimization in sparse data environments

Due to the high penetrating power of cosmic-ray muons, they can be used to probe very thick and dense objects. As muons are charged particles, they can be tracked by ionization detectors, determining the position and direction of the muons. With detectors on either side of an object to measure particle direction change, scattering information within the object can be found. This can be used to produce a scattering-intensity image within the object related to density and atomic number. Such imaging is typically performed with a single detector-object orientation, taking advantage of the more intense downward flux of muons, producing planar imaging with some depth-of-field information in the third dimension. Several simulation studies were published with multiorientation tomography, which can form a three-dimensional representation faster than a single-orientation view. In this study, experimental muon-scatter-based tomography was performed using a concrete filled steel drum with several different metal wedges inside, with the drum between detector planes. Data were collected from different detector-object orientations by rotating the steel drum. The data collected from each orientation were combined using two different tomographic methods. A traditional inverse Radon transform approach used for computed tomography and a combination of multiple depth-of-field reconstructions were applied to the data. As cosmic-ray muon flux imaging is rate limited, the imaging techniques were compared for sparse data. Using the combined depth-of-field reconstruction technique, fewer detector-object orientations were needed to reconstruct images that could be used to differentiate the metal wedges.

47 OTHER INSTRUMENTATION↗

Study of interface reaction in a B 4 C/Cr mirror at elevated temperature using soft X-ray reflectivity

Boron carbide is a prominent material for high-brilliance synchrotron optics as it remains stable up to very high temperatures. The present study shows a significant change taking place at 550°C in the buried interface region formed between the Cr adhesive layer and the native oxide layer present on the silicon substrate. An in situ annealing study is carried out at the Indus-1 Reflectivity beamline from room temperature to 550°C (100°C steps). The studied sample is a mirror-like boron carbide thin film of 400 Å thickness deposited with an adhesive layer of 20 Å Cr on a silicon substrate. The corresponding changes in the film structure are recorded using angle-dependent soft X-ray reflectivity measurements carried out in the region of the boron K-edge after each annealing temperature. Analyses performed using the Parratt recursive formalism reveal that the top boron carbide layer remains intact but interface reactions take place in the buried Cr–SiO2 region. After 300°C the Cr layer diffuses towards the substrate. At higher temperatures of 500°C and 550°C the Cr reacts with the native oxide layer and tends to form a low-density compound of chromium oxysilicide (CrSiOx). Depth profiling of Si and Cr distributions obtained from secondary ion mass spectroscopy measurements corroborate the layer model obtained from the soft X-ray reflectivity analyses. Details of the interface reaction taking place near the substrate region of boron carbide/Cr sample are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of Advanced, Radiation Resistant, Optical-based Detector Technology for Future Experiments.

The primary objective of this project has been to advance the design of high-performance electromagnetic (EM) calorimeters for future particle physics experiments, to identify and measure the timing, position and energy of electrons, positrons and gamma rays, particularly in high-luminosity environments with intense radiation and pileup conditions. To meet such challenges, the proposed research has focused on the development of ultra-compact, radiation-hard calorimeter modules, to provide excellent timing, spatial, and energy resolution. The work aligns with the DOE’s Basic Research Needs (BRN) for High Energy Physics (HEP) Instrumentation and the research team contributes actively to the Coordinating Panel on Advanced Detectors (CPAD) RDC9 calorimetry collaboration in the USA and the European Committee on Future Accelerators (ECFA) DRD-CALO calorimetry collaboration at CERN, the European Laboratory for Particle Physics located in Geneva, Switzerland. The research builds on the RADiCAL (radiation-hard, ultra-compact) modular sampling calorimeter approach, developed by the research team, which employs dense and very bright optical materials such as LYSO:Ce scintillator plates that are interleaved with very dense tungsten plates to minimize detector size while optimizing performance. The modules are comparable in size to a human index finger, dimensionally 14 mm x 14 mm in cross section and 135 mm in length. And despite the small size, the structure is capable of providing excellent timing and energy resolution. This is facilitated through the use of specialized quartz capillaries filled with wavelength-shifting filaments, positioned at various depths along the length of a module, to collect and guide light signals to silicon photomultipliers (SiPMs) which detect and convert the optical signals to electronic signals for analysis. The primary goals of this project have been: (1) Achieve a timing resolution to σ t ≤ 30 ps for high-energy electrons and photons, important for their association with specific events produced in colliding-beam experiments and for the detection of decays-in-flight of long-lived particles. The project has achieved this goal in beam tests of a single RADiCAL module at CERN, during which a timing resolution of σ t = 27 ps was measured for electrons of energy E = 150 GeV. Based upon a mathematical fit to the data measured over a broad energy range from low energy to high energy, a resolution of σ t ≤ 18 ps has been estimated for electrons of very high (TeV) energy. From these measurements and with further expected technical improvements, the timing resolution should reach σ t ≤ 10 ps, important for searches for discovery physics in upcoming and future experiments. (2) Achieve an energy resolution of σ E / E ≤ 10% / $\sqrt{E}$. The project has yet to achieve this goal, but is close to it, having measured a value of σ E / E ≤ 15.9% / $\sqrt{E}$ using a modular array. Ultimately, the resolution goal is expected to be reached by adjustments to material thicknesses within the modules, which will improve the sampling fraction to measure more precisely the shower energy for lower energy particles. The versatility of the modular RADiCAL approach enables the testing of advanced materials, photosensors and electronics, developed in collaboration with CPAD RDC and ECFA DRD-CALO groups. The structure can distinguish electrons, positrons and gamma rays from hadrons and muons and beam-induced backgrounds, making it a valuable tool in a variety of detector environments, including future circular colliders (FCC-ee, FCC-hh) proposed for the European Laboratory for Particle Physics (CERN), the muon-collider proposed for Fermi National Accelerator Laboratory (Fermilab), and searches for new physics in beam-dump, fixed target and forward-physics experiments. And, while designed with particle physics applications in mind, the technologies developed in this project have the potential for application more broadly in particle and nuclear physics, materials science, and medical physics, underscoring the far-reaching potential of this line of instrumentation research and development.

47 OTHER INSTRUMENTATION↗

The Scattered Light Time-history Diagnostic suite at the National Ignition Facility

The Scattered Light Time-history Diagnostic (SLTD) is being implemented at the National Ignition Facility (NIF) to greatly expand the angular coverage of absolute scattered-light measurements for direct- and indirect-drive inertial confinement fusion (ICF) experiments. The SLTD array will ultimately consist of 15 units mounted at a variety of polar and azimuthal angles on the NIF target chamber, complementing the existing NIF backscatter suite. Each SLTD unit collects and diffuses scattered light onto a set of three optical fibers, which transport the light to filtered photodiodes to measure scattered light in different wavelength bands: stimulated Brillouin scattering (350 nm–352 nm), stimulated Raman scattering (430 nm–760 nm), and ω/2 (695 nm–745 nm). SLTD measures scattered light with a time resolution of ~1 ns and a signal-to-noise ratio of up to 500. Currently, six units are operational and recording data. Measurements of the angular dependence of scattered light will strongly constrain models of laser energy coupling in ICF experiments and allow for a more robust inference of the total laser energy coupled to implosions.

47 OTHER INSTRUMENTATION↗

Continuous Light Absorption Photometer (CLAP) Instrument Handbook

Reliable measurements of aerosol light absorption are crucial for quantifying the radiative forcing of climate. As a consequence, light absorption measurements are recommended for all stations in the Global Atmosphere Watch network, which is coordinated by the World Meteorological Organization. Aerosol light absorption is often dominated by soot-like particles produced by the incomplete combustion of carbonaceous fuels, commonly termed "black carbon", and optical methods are the primary way that equivalent black carbon concentrations are derived. Two basic approaches are used for determining the aerosol light absorption coefficient: in situ methods where the absorption is measured while the particles are suspended in air, and filter-based methods where the particles are deposited on a filter for real-time optical analysis. In situ methods are inherently more accurate because the physical state of the particles can be changed by the act of filtration. Unfortunately, currently available instruments for in situ measurements are more expensive and difficult to operate than filter-based methods, making them better suited for use in intensive field campaigns or as laboratory reference instruments. Filter-based instruments, because of their lower cost and simpler operation, have been the preferred choice for long-term measurements of aerosol light absorption in monitoring networks.

54 ENVIRONMENTAL SCIENCES↗

Optical constants of magnetron sputtered aluminum in the range 17–1300 eV with improved accuracy and ultrahigh resolution in the L absorption edge region

This work determines a new set of EUV/x-ray optical constants for aluminum (Al), one of the most important materials in science and technology. Absolute photoabsorption (transmittance) measurements in the 17–1300 eV spectral range were performed on freestanding Al films protected by carbon (C) layers, to prevent oxidation. The dispersive portion of the refractive index was obtained via the Kramers–Kronig transformation. Our data provide significant improvements in accuracy compared to previously tabulated values and reveal fine structure in the Al L 1 and L 2,3 regions, with photon energy step sizes as small as 0.02 eV. The implications of this work in the successful realization of EUV/x-ray instruments and in the validation of atomic and molecular physics models are also discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Results from a synthetic model of the ITER XRCS-Core diagnostic based on high-fidelity x-ray ray tracing

A high-fidelity synthetic diagnostic has been developed for the ITER core x-ray crystal spectrometer diagnostic based on x-ray ray tracing. This synthetic diagnostic has been used to model expected performance of the diagnostic, to aid in diagnostic design, and to develop engineering tolerances. The synthetic model is based on x-ray ray tracing using the recently developed xicsrt ray tracing code and includes a fully three-dimensional representation of the diagnostic based on the computer aided design. The modeled components are: plasma geometry and emission profiles, highly oriented pyrolytic graphite pre-reflectors, spherically bent crystals, and pixelated x-ray detectors. Plasma emission profiles have been calculated for Xe 44+ , Xe 47+ , and Xe 51+ , based on an ITER operational scenario available through the Integrated Modelling & Analysis Suite database, and modeled within the ray tracing code as a volumetric x-ray source; the shape of the plasma source is determined by equilibrium geometry and an appropriate wavelength distribution to match the expected ion temperature profile. All individual components of the x-ray optical system have been modeled with high-fidelity producing a synthetic detector image that is expected to closely match what will be seen in the final as-built system. Particular care is taken to maintain preservation of photon statistics throughout the ray tracing allowing for quantitative estimates of diagnostic performance.

47 OTHER INSTRUMENTATION↗

Smart Adhesive Joint with High-Definition Fiber-Optic Sensing for Automotive Applications

Structural health monitoring of fiber-reinforced composite-based joints for automotive applications during their manufacturing and on-demand assessment for its durability in working environments is critically needed. High-definition fiber-optic sensing is an effective method to measure internal strain/stress development using minimally invasive continuous sensors. The sensing fiber diameters are in the same order of magnitude when compared to reinforcement (glass, basalt, or carbon fibers) used in polymer composites. They also offer a unique ability to monitor the evolution of residual stresses after repeated thermal exposure with varying temperatures for automotive components/joints during painting using an electrophoretic painting process. In this paper, a high-definition fiber-optic sensor utilizing Rayleigh scattering is embedded within an adhesive joint between a carbon fiber-reinforced thermoset composite panel and an aluminum panel to measure spatially resolved strain development, residual strain, and thermal expansion properties during the electrophoretic paint process-simulated conditions. The strain measured by the continuous fiber-optic sensor was compared with an alternate technique using thermal digital image correlation. The fiber-optic sensor was able to identify the spatial variation of residual strains for a discontinuous carbon fiber-reinforced composite with varying local fiber orientations and resin content.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fiber optic sensing for strain and temperature

Fiber optic sensing for strain and temperature. This presentation reports the status of the R&D work performed at FNAL on a novel diagnostic tool for superconducting magnet based on fiber optics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Chalcogenide Glass-Capped Fiber-Optic Sensor for Real-Time Temperature Monitoring in Extreme Environments

We demonstrate a novel chalcogenide glass (ChG)-capped optical fiber temperature sensor capable of operating within harsh environment. The sensor architecture utilizes the heat-induced phase change (amorphous-to-crystalline) property of ChGs, which rapidly (80–100 ns) changes the optical properties of the material. The sensor response to temperature variation around the phase change of the ChG cap at the tip of the fiber provides abrupt changes in the reflected power intensity. This temperature is indicative of the temperature at the sensing node. We present the sensing performance of six different compositions of ChGs and a method to interpret the temperature profile between 440 °C and 600 °C in real-time using an array structure. The unique radiation-hardness property of ChGs makes the devices compatible with high-temperature and high-radiation environments, such as monitoring the cladding temperature of Light Water (LWR) or Sodium-cooled Fast (SFR) reactors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultrafast electron dynamics in platinum and gold thin films driven by optical and terahertz fields

Here, we investigate the ultrafast electron dynamics triggered by terahertz and optical pulses in thin platinum and gold films by probing their transient optical reflectivity. The response of the platinum film to an intense terahertz pulse is similar to the optically induced one and can be described by a two-temperature model with a 20% larger electron–phonon coupling for the terahertz-driven dynamics compared to the optically induced one, ascribed to an additional nonthermal electron–phonon coupling contribution. Surprisingly, gold films exhibit a much smaller terahertz pulse-induced reflectivity change and with a sign opposite to the optical case. Additionally we explain this remarkable observation with field emission of electrons due to Fowler–Nordheim tunneling, enabled in samples with thicknesses below the structural percolation threshold, where nanostructuring promotes near-field enhancement. Our results provide a fundamental insight into the ultrafast processes relevant to modern electro- and magneto-optical applications.

74 ATOMIC AND MOLECULAR PHYSICS↗