Pixel response characterization of the ARCADIA fully depleted MAPS

Monolithic Active Pixel Sensors (MAPS) achieved widespread use in several scientific applications, thanks to their properties, such as low material budget and high granularity. The ARCADIA INFN project developed a Fully-Depleted MAPS (FD-MAPS), using a modified LFoundry 110 nm CIS process. This work presents the first laboratory characterization of the ARCADIA MD3 prototype. Measurements include threshold uniformity studies using both test-pulse injection and a 55 Fe source, as well as threshold and noise calibration achieved thanks to monochromatic X-ray sources. Ultimately, charge-collection efficiency is evaluated using an infrared laser setup.

Particle tracking detectors↗

Opportunities and challenges to study solar neutrinos with a Q-Pix pixel readout

The study of solar neutrinos presents significant opportunities in astrophysics, nuclear physics, and particle physics. However, the low-energy nature of these neutrinos introduces considerable challenges to isolate them from background events, requiring detectors with low-energy threshold, high spatial and energy resolutions, and low data rate. We present the study of solar neutrinos with a kiloton-scale liquid argon detector located underground, instrumented with a pixel readout using the Q-Pix technology. We explore the potential of using volume fiducialization, directional topological information, light signal coincidence, and pulse-shape discrimination to enhance solar neutrino sensitivity. We find that discriminating neutrino signals below 5 MeV is very difficult. However, we show that these methods are useful for the detection of solar neutrinos when external backgrounds are sufficiently understood and when the detector is built using low-background techniques. When building a workable background model for this study, we identify 𝛾 background from the cavern walls and from capture of 𝛼 particles in radon decay chains as both critical to solar neutrino sensitivity and significantly underconstrained by existing measurements. Finally, we highlight that the main advantage of the use of Q-Pix for solar neutrino studies lies in its ability to enable the continuous readout of all low-energy events with minimal data rates and manageable storage for further off-line analyses.

multi-purpose particle detectors↗

High-energy micrometre-scale pixel direct conversion X-ray detector

The objective of this work was to fabricate and characterize a new X-ray imaging detector with micrometre-scale pixel dimensions (7.8 µm) and high detection efficiency for hard X-ray energies above 20 keV. A key technology component consists of a monolithic hybrid detector built by direct deposition of an amorphous selenium film on a custom designed CMOS readout integrated circuit. Characterization was carried out at the synchrotron beamline 1-BM-B at the Advanced Photon Source of Argonne National Laboratory. The direct conversion detector demonstrated micrometre-scale spatial resolution with a 63 keV modulation transfer function of 10% at Nyquist frequency. In addition, spatial resolving power down to 8 µm was determined by imaging a transmission bar target at 21 keV. X-ray signal linearity, responsivity and lag were also characterized in the same energy range. Finally, phase contrast edge enhancement was observed in a phase object placed in the beam path. This amorphous selenium/CMOS detector technology can address gaps in commercially available X-ray detectors which limit their usefulness for existing synchrotron applications at energies greater than 50 keV; for example, phase contrast tomography and high-resolution imaging of nanoscale lattice distortions in bulk crystalline materials using Bragg coherent diffraction imaging. Here, the technology will also facilitate the creation of novel synchrotron imaging applications for X-ray energies at or above 20 keV.

36 MATERIALS SCIENCE↗

Development of an MKID frequency-to-pixel LED mapper for SPT-3G+

SPT-3G+ is the next-generation camera for the South Pole Telescope (SPT). SPT is designed to measure the cosmic microwave background (CMB) and the mm/sub-mm sky. The planned focal plane consists of 34,000 microwave kinetic inductance detectors (MKIDs), divided among three observing bands centered at 220, 285, and 345 GHz. Each readout line is designed to measure 800 MKIDs over a 500 MHz bandwidth, which places stringent constraints on the accuracy of the frequency placement required to limit resonator collisions that reduce the overall detector yield. To meet this constraint, we are developing a two-step process that first optically maps the resonance to a physical pixel location, and then next trims the interdigitated capacitor (IDC) to adjust the resonator frequency. We present a cryogenic LED apparatus operable at 300 mK for the optical illumination of SPT-3G+ detector arrays. We demonstrate integration of the LED controls with the GHz readout electronics (RF-ICE) to take data on an array of prototype SPT-3G+ detectors. We show that this technique is useful for characterizing defects in the resonator frequency across the detector array and will allow for improvements in the detector yield.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Filtered Backprojection in Compton Imaging using a Spherical Harmonic Wiener Filter with Pixelated CdZnTe

Filtered backprojection is an image reconstruction technique for Compton imaging that provides reasonably high resolution at much lower computational costs when compared to iterative methods. Here, this work applies a Wiener filter that has been derived for spherical harmonics on Compton imaging using the OrionUM pixelated CdZnTe imaging-spectrometer. To regularize the filter, an investigation is made into the power spectral density of the signal and noise to develop an appropriate spectral signal-to-noise ratio model for the restoration process. Experimental measurements were conducted with two 228Th sources placed 30° apart. The resulting filtered image of the two sources have an average full-width-at-half-maximum (FWHM) of 9.8° or 7.5° when using a mean squared error and structural similarity optimization approach respectively; an improvement from the 29.0° FWHM image when using simple backprojection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GPU-Accelerated Analytic Simulation of Sparse Ionization Signal Formation in Pixelated Projection Detector

This paper presents a GPU-accelerated simulation package, TRED, for next-generation neutrino detectors with pixelated charge readout, leveraging community-driven software ecosystems to ensure adaptability and extensibility. We introduce two generic contributions: (i) an effective-charge representation based on Gaussian quadrature rules, in which the linear- interpolation factors for the field response inside each voxel are absorbed into the effective charge, and (ii) a sparse, block- binned tensor representation that enables efficient FFT-based computation of induced signals on readout electrodes for sparsely activated detector volumes. The former captures structure inside a voxel without dense sampling, while the latter achieves low memory usage and scalable runtime, as demonstrated in bench- mark studies. The underlying data representation is applicable to large-scale detectors and to other computational problems involving sparse activity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Source noise suppression in attosecond transient absorption spectroscopy by edge-pixel referencing

Attosecond transient absorption spectroscopy (ATAS) is used to observe photoexcited dynamics with outstanding time resolution. The main experimental challenge of this technique is that high-harmonic generation sources show significant instabilities, resulting in sub-par sensitivity when compared to other techniques. This paper proposes edge-pixel referencing as a means to suppress this noise. Two approaches are introduced: the first is deterministic and uses a correlation analysis, while the second relies on singular value decomposition. Each method is demonstrated and quantified on a noisy measurement taken on WS 2 and results in a fivefold increase in sensitivity. The combination of the two methods ensures the fidelity of the procedure and can be implemented on live data collection but also on existing datasets. The results show that edge-referencing methods bring the sensitivity of ATAS near the detector noise floor. An implementation of the post-processing code is provided to the reader.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Single-pixel reconstructive mid-infrared micro-spectrometer

Miniaturized spectrometers in the mid-infrared (MIR) are critical in developing next-generation portable electronics for advanced sensing and analysis. The bulky gratings or detector/filter arrays in conventional micro-spectrometers set a physical limitation to their miniaturization. In this work, we demonstrate a single-pixel MIR micro-spectrometer that reconstructs the sample transmission spectrum by a spectrally dispersed light source instead of spatially grated light beams. The spectrally tunable MIR light source is realized based on the thermal emissivity engineered via the metal-insulator phase transition of vanadium dioxide (VO 2 ). We validate the performance by showing that the transmission spectrum of a magnesium fluoride (MgF 2 ) sample can be computationally reconstructed from sensor responses at varied light source temperatures. With potentially minimum footprint due to the array-free design, our work opens the possibility where compact MIR spectrometers are integrated into portable electronic systems for versatile applications.

47 OTHER INSTRUMENTATION↗

Forward Pixel Detector for the Phase 2 Upgrade of CMS And Module Testing at UIC

High-Luminosity Large Hadron Collider (HL-LHC) upgrade aims to increase performance. In order to efficiently handle the larger particle flux and increased radiation, an upgrade is planned for the inner Tracker of the Compact Muon Solenoid (CMS) detector, which is located at the innermost part of the CMS. To efficiently reconstruct and track particles, the existing pixel tracker will be upgraded with novel sensors, readout chips, and front-end electronics designed to handle increased data rates. These improvements will allow the detector to track particles more precisely. In the United States, we are working on assembling new sensor modules to be inserted into disks, referred to as TFPX, for installation in the CMS detector for the HL-LHC era. We are currently testing the prototype of TFPX modules to ensure the upgrade is carried out in the best way possible. The University of Ilinois Chicago has been tasked with testing the final versions of the TFPX sensor modules before they are sent to CERN to be installed into the CMS detector. This work is supported by NSF.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

ML-Based Reconstruction in a Pixelated LArTPC

The Deep Underground Neutrino Experiment (DUNE) will address open issues in neutrino physics such as the measurement of the CP-violating phase in neutrino oscillations and the neutrino mass ordering. DUNE is expected to have the most energetic neutrino beam in the world. The 2x2 demonstrator is a single-phase liquid argon time projection chamber (LArTPC), with four modules, operated as a prototype for the DUNE Liquid Argon Near Detector (ND-LAr). Each module in the 2x2 demonstrator is 0.67m x 0.67m x 1.8m. Based on the ArgonCube design concept, the 2x2 features a novel pixelated charge readout and advanced high-coverage photon detection system. Machine learning can be used to form a complete reconstruction pipeline for physics interactions in the 2x2 detector. This poster will describe the workings of a package under development called SPINE and its current performance.

43 PARTICLE ACCELERATORS↗

Developing a Novel Neutron Time-of-Flight Diagnostic Platform for Z: Ultrafast Pixel Array Camera System

This report describes a Late-Start LDRD project on a compact neutron time-of-flight (nTOF) diagnostic, based on the Ultra-Fast Pixel Array Camera (UPAC) platform. By leveraging advancements in microelectronics, the UPAC nTOF is designed to address existing challenges of current nTOFs at the Z-machine that rely on large scintillators and photomultiplier tubes using bulky, discrete digitizing units hindering scalability with signal routing presenting an additional challenge. The report describes the UPAC diagnostic platform, outlines the calibration of the diagnostic and the latest results of fielding the UPAC as a ride-a-long diagnostic on the Magnetized liner inertial fusion (MagLIF) campaigns at the Z-machine supported by the Late-Start LDRD, and finally discusses conclusions and proposed future work.

42 ENGINEERING↗

Beam Test Characterization of an Irradiated Pixel-Strip Module for HL_LHC CMS Tracker Upgrade

A new tracker, for the CMS detector at The Large Hadron Collider, will be built to address the demands of the High Luminosity upgrade which aims to achieve peak instantaneous luminosities from 5 up to 7.5 10^34 cm^-2 s^-1 and an integrated luminosity of 3000 4000 fb^-1 at a center of mass energy of 14 TeV. To meet the resulting challenges, the CMS experiment is changing its outer tracker silicon modules to include tracking capabilities at the Level-1 trigger. As part of this upgrade effort, a prototype module, combining both pixel and strip sensors (PS-module), was irradiated and subsequently tested at the Fermilab Test Beam and Irradiation facilities. These tests evaluated the module's ability to maintain precise tracking, effective particle momentum discrimination, and consistent performance when exposed to the radiation levels expected in the High Luminosity LHC environment. Results from these studies are presented with a focus on comparing the module's performance before and after irradiation.

43 PARTICLE ACCELERATORS↗

Heterogeneous Reconstruction of Tracks and Primary Vertices With the CMS Pixel Tracker

The High-Luminosity upgrade of the Large Hadron Collider (LHC) will see the accelerator reach an instantaneous luminosity of 7 × 10 34 cm −2 s −1 with an average pileup of 200 proton-proton collisions. These conditions will pose an unprecedented challenge to the online and offline reconstruction software developed by the experiments. The computational complexity will exceed by far the expected increase in processing power for conventional CPUs, demanding an alternative approach. Industry and High-Performance Computing (HPC) centers are successfully using heterogeneous computing platforms to achieve higher throughput and better energy efficiency by matching each job to the most appropriate architecture. In this paper we will describe the results of a heterogeneous implementation of pixel tracks and vertices reconstruction chain on Graphics Processing Units (GPUs). The framework has been designed and developed to be integrated in the CMS reconstruction software, CMSSW. The speed up achieved by leveraging GPUs allows for more complex algorithms to be executed, obtaining better physics output and a higher throughput.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Operation of a Modular 3D-Pixelated Liquid Argon Time-Projection Chamber in a Neutrino Beam

The 2x2 Demonstrator, a prototype for the Deep Underground Neutrino Experiment (DUNE) liquid argon (LAr) Near Detector, was exposed to the Neutrinos from the Main Injector (NuMI) neutrino beam at Fermi National Accelerator Laboratory (Fermilab). This detector is a prototype of a new modular design for a liquid argon time-projection chamber (LArTPC), comprising a two-by-two array of four modules, each further segmented into two optically isolated LArTPCs. The 2x2 Demonstrator features a number of pioneering technologies, including a low-profile resistive field shell to establish drift fields, native 3D ionization pixelated imaging, and a high-coverage dielectric light readout system. The 2.4-tonne active mass detector is flanked upstream and downstream by supplemental solid-scintillator tracking planes, repurposed from the MINERvA experiment, which track ionizing particles exiting the argon volume. The antineutrino beam data collected by the detector over a 4.5 day period in 2024 include over 30,000 neutrino interactions in the LAr active volume—the first neutrino interactions reported by a DUNE detector prototype. During its physics-quality run, the 2x2 Demonstrator operated at a nominal drift field of 500 V/cm and maintained good LAr purity, with a stable electron lifetime of approximately 1.25 ms. This paper describes the detector and supporting systems, summarizes the installation and commissioning, and presents the initial validation of collected NuMI beam and off-beam self-triggers. In addition, it highlights observed interactions in the detector volume, including candidate muon antineutrino events.

47 OTHER INSTRUMENTATION↗

Performance of a Modular Ton-Scale Pixel-Readout Liquid Argon Time Projection Chamber

The Module-0 Demonstrator is a single-phase 600 kg liquid argon time projection chamber operated as a prototype for the DUNE liquid argon near detector. Based on the ArgonCube design concept, Module-0 features a novel 80k-channel pixelated charge readout and advanced high-coverage photon detection system. In this paper, we present an analysis of an eight-day data set consisting of 25 million cosmic ray events collected in the spring of 2021. We use this sample to demonstrate the imaging performance of the charge and light readout systems as well as the signal correlations between the two. We also report argon purity and detector uniformity measurements and provide comparisons to detector simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Counting of Hong-Ou-Mandel Bunched Optical Photons Using a Fast Pixel Camera

The uses of a silicon-pixel camera with very good time resolution (∼nanosecond) for detecting multiple, bunched optical photons is explored. We present characteristics of the camera and describe experiments proving its counting capabilities. We use a spontaneous parametric down-conversion source to generate correlated photon pairs, and exploit the Hong-Ou-Mandel (HOM) interference effect in a fiber-coupled beam splitter to bunch the pair onto the same output fiber. It is shown that the time and spatial resolution of the camera enables independent detection of two photons emerging simultaneously from a single spatial mode.

47 OTHER INSTRUMENTATION↗