Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Beaming”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Design and Principles of Linear Accelerators and Colliders." in Particle Physics Reference Library, pp. 295-336. Springer, Cham, 2020.

Linear accelerators (linacs) use alternating radiofrequency (RF) electromagnetic fields to accelerate charged particles in a straight line. Linacs were invented about 95 years ago and have seen many significant technical innovations since. A wide range of particle beams have been accelerated with linacs including beams of electrons, positrons, protons, antiprotons, and heavy ions. Linac parameter possibilities include pulsed versus continuous wave, low and high beam powers, low and high repetition rates, low transverse emittance beams, short bunches with small energy spreads, and accelerated multiple bunches in a single pulse. The number of linacs around the world has grown tremendously with thousands of linacs in present use, many for medical therapy, in industry, and for research and development in a broad spectrum of scientific fields. Researchers have developed accelerators for scientific tools in their own right, being awarded several Nobel prizes. Moreover, linacs and particle accelerators in general have enabled many discovery level science experiments in related fields, resulting in many Nobel prizes as well.

Seeman, John↗

Mitigation of Beam Losses in LANSCE Linear Accelerator

Suppression of beam losses is essential for successful operation of high-intensity accelerator facility. The LANSCE accelerator started routine operation in 1972 as a 0.8 MW average proton beam power facility for meson physics research, and delivered highpower beam for a quarter century. The accelerator currently delivers 100 MeV proton beam to Isotope Production Facility (IPF) and 800 MeV H- beams to various experimental areas. The accelerator is equipped with two independent injectors for H + and H - beams, merging at the entrance of a 201.25 MHz Drift Tube Linac (DTL). The DTL performs acceleration up to the energy of 100 MeV. After the DTL, the Transition Region beamline directs a 100 MeV proton beam to the Isotope Production Facility, while the H - beam is accelerated up to the final energy of 800 MeV in an 805- MHz Coupled Cavity Linac. The H - beams, created with different time structure by a lowenergy chopper, are distributed in the Switch Yard (SY) to four experimental areas: the Lujan Neutron Scattering Center equipped with a Proton Storage Ring (PSR), the Weapons Neutron Research facility (WNR), the Proton Radiography facility (pRad), and the Ultra-Cold Neutron facility (UCN). Multi-beam operation requires careful control of accelerator tune to minimize beam losses. In this paper we review main effects affecting beam losses in LANSCE linear accelerator and discuss methods to reduce them.

43 PARTICLE ACCELERATORS↗

Spectral and Spatial Properties of Amplified Radiation in High Gain Tapering Enhanced Stimulated Super-radiant Amplification Regime (Technical Report)

There is a wide convergence of scientific and industrial interests in understanding the physics of high efficiency conversion of relativistic electron beam power into coherent radiation. Improved understanding would open the door to ultrahigh intensity X-ray laser pulses (single shot coherent imaging and Schwingerfield physics), as well as at longer wavelength for fast throughput material processing (EUV-lithography). Modern particle accelerators can be extremely efficient (approaching 50 %) in terms of wall-plug energy use. State-of-the-art light sources on the other hand do not take advantage of all the available power and most of it is left in the beam and simply wasted on the beam dump. This proposal aimed at developing a program based on Tapered Enhanced Stimulated Superradiant Amplification to address the current limitation in electron-based coherent radiation generation exploiting the progress in high brightness beam generation and strong coupling with the electromagnetic field in a strongly tapered undulator system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

RECORD FAST CYCLING ACCELERATOR MAGNET BASED ON HIGH TEMPERATURE SUPERCONDUCTOR

We report on the High Temperature Superconductor (HTS) based prototype accelerator magnet capable to operate at 12 T/s B-field ramping rate with a very low supporting cryogenic cooling power thus indicating a feasibility of its application in the accelerator requiring high repetition rate and high average beam power. The magnet is designed to simultaneously accelerate two particle beams in the separate beam gaps energized by a single conductor. The design, construction and the power test of the prototype fast-cycling HTS based accelerator magnet is presented while the more detailed description and power test data analysis s given in [1]. As example, the measured cryogenic power loss limit is discussed in terms of the feasibility of application of such a magnet for the construction of the 8 GeV dual proton beam Booster.

43 PARTICLE ACCELERATORS↗

Progress towards 28 GHz operations at the Facility for Rare Isotope Beams (FRIB)

This paper provides an overview on the design, operational parameters as well as recent development and recent performance, of the superconducting electron cyclotron resonance (ECR) ion source at the Facility for Rare Isotope Beams (FRIB). The ion source has been used in support of beam operations since the end of 2022 and was designed to operate at 28 GHz and be capable of delivering high intensity uranium beams to help support beam delivery of up to a final beam power of 400 kW. Currently operating at up to 20 kW many primary beams have been developed and routinely used with the superconducting ECR including uranium. Initially operated at 18 GHz, the ion source has now been coupled to a 28 GHz gyrotron and high intensity beams have been demonstrated ahead of the facility planned power ramp up. text with the article abstract. Replace this text with the article abstract.

Machicoane, G. A. [Michigan State University, East↗

Behind the High Power Targetry R&D at Fermilab

• Recently major accelerator facilities have been limited in beam power not by their accelerators, but by their target facilities – Current high power, high intensity targets in use at Fermilab – Plans for future high power, high intensity target facilities

43 PARTICLE ACCELERATORS↗

Explaining the lack of power degradation of energy confinement in wide pedestal quiescent H-modes via transport modeling

Wide pedestal quiescent H (WPQH)-mode is an attractive scenario for future burning plasmas as they operate without ELMs. WPQH is characterized by formation of a wider and higher pedestal (than quiescent H-mode), and broadband fluctuations in the pedestal. Unlike conventional H-modes, where the energy confinement time reduces with increasing heating power, the WPQH plasmas reported in this paper do not show power degradation of the energy confinement. As the injected neutral beam power was increased, reduced core (ρ ≤ 0.45) transport calculated by transp, as well as increased core temperatures, pressure gradient and diamagnetic E × B shear rate were observed. The reduction in the heat transport and rapid decrease in the ion temperature gradient scale length suggest the formation of an ion internal transport barrier (ITB) that was accompanied by increased stored energy in the core. Quasilinear turbulent transport modeling using the trapped gyro Landau fluid (tglf) code was used to predict the ITB and its turbulence stability properties. By using profiles and equilibria produced by matching the transp transport fluxes with the tglf transport model within the tgyro transport solver, the energy confinement time captures the experimentally observed insensitivity to the increased PNBI. Linear stability analysis reveals that drift-wave instabilities in the core are stabilized by E × B shear, T i /T e ratio and Shafranov shift; the latter was found to have the strongest effect on the turbulence suppression at the highest heating level.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

LANSCE Accelerator Modernization Project (LAMP) Overview [Slides]

LANSCE is based on a high-current 800 MeV proton accelerator capable of delivering 1 MW of beam power to the central target area. The LANSCE accelerator provides beam simultaneously to 5 separate experimental areas. LANSCE operates with 650 µs RF macro pulses at 120 Hz. Within this macro pulse several different beam timing patterns are utilized. LANSCE also accelerates H + and H – simultaneously. LANSCE celebrated 50 years of beam delivery in 2022.

43 PARTICLE ACCELERATORS↗

The Fermilab Facility for Dark Matter Discovery (F2D2): A Conceptual PIP-II Beam Stop Facility for Dark Sector Physics

What do the accelerator target stations of the next decade look like? The NuMI beamline, fed by Fermilab s Main Injector, recently exceeded 1 MW beam power. Future experiments fed by the PIP-II superconducting linear accelerator might demand upwards of 2 MW in continuous-wave mode, compared to the pulsed beams typical of neutrino experiments. Looking further into the future, the Muon Collider front end includes a target station with even higher power 5 MW or beyond. How do we build a 2+ MW target facility? How does a high-power, low-energy, CW beam affect target design compared to conventional high-energy neutrino targets? How do we manage radiation and heat? How is the facility serviced? What is the current state of capability, and what technologies do we need to develop? These questions are answered in the context of F2D2, a conceptual target station design for dark sector physics experiments using beam from PIP-II.

Williams, Jonathan K.↗

FRIB Transition to User Operations, Power Ramp Up, and Upgrade Perspectives

After project completion on scope, on cost, and ahead of schedule, the Facility for Rare Isotope Beams began operations for scientific users in May of 2022. During the first 12 months of user operations, the FRIB accelerator complex delivered 5250 beam hours, including 1528 hours to nine science experiments conducted with primary beams of 36Ar, 48Ca, 70Zn, 82Se, 124Xe, and 198Pt at beam energies >200 MeV/u; 2724 hours for beam developments, studies, and tuning; and 998 hours to industrial users and non-scientific programs using the FRIB Single Event Effect (FSEE) beam line. The ramp-up to a beam power of 400 kW is planned over a six-year period; 1 kW was delivered for initial user runs from in 2022, and 5 kW was delivered as of February 2023. Upgrade plans include doubling the primary-beam energy to 400 MeV/nucleon for enhanced discovery potential (¿FRIB 400¿). This talk reports on FRIB status and progress since SRF2021, emphasizing lessons learned during the transition from beam commissioning to machine operations, challenges and resolutions for the power ramp-up, progress with accelerator improvements, and R&D for the energy upgrade.

43 PARTICLE ACCELERATORS↗

Molten Salt Targets for Future High-Power Accelerator Facilities

This talk will give an overview of will give an overview of recent work that began to examine the feasibility of molten salts as a target material for very high power beams as a potential solution for some of the present and future challenges of high power targetry at Fermilab, anchored by the F2D2 conceptual design study. This will include discussion of target and beam dump applications as well as likely challenges, potential for future R&D, projects, and synergy with existing high-power targetry research.

Williams, Jonathan K. [Fermilab]↗

Radiation damage study of POCO ZXF-5Q graphite for neutrino production targets using 4.5 MeV helium ions

To address the challenges of increased beam power and target survivability associated with next-generation particle production beam lines, high dose, high-energy proton beam conditions are simulated using irradiation from low-energy ion beams. A low-energy ion irradiation study of POCO ZXF-5Q graphite under conditions similar to those of the NuMI NT-02 neutrino production target at the Fermi National Accelerator Laboratory is reported. Helium ion irradiation was performed at 100 ∘ C to a maximum damage level of 0.9 displacements per atom (DPA). Irradiation induced hardening, swelling of the irradiated region, inter-plane lattice expansion, and intraplane lattice contraction with increasing ion fluence was observed using micromechanical (nanoindentation, atomic force microscopy) and electron microscopy (high-resolution imaging, selected area diffraction) characterization. Similar changes were also observed in post irradiation examination of the NT-02 target indicating that ion irradiation can be a valuable tool for estimating radiation damage in proton beam targets. Caution must be exercised though, because the hardening, lattice alteration, and swelling occur to different magnitudes for a given damage level. The observed hardening and embrittlement were greater for ion irradiated graphite. For He ion irradiated samples the lattice spacing changes were smaller at low damage levels (78% less expansion and 71% less contraction at 0.1 DPA) and larger at high damage levels (38% more expansion and 5% more contraction at 0.9 DPA) relative to that observed in the NT-02 target. The magnitude of swelling was 8.5× greater under ion irradiation which is influenced by the differing damage gradients and inclusion of implanted He ions in the region of interest.

43 PARTICLE ACCELERATORS↗

Feasibility of using crystal channeling for the beam loss mitigation in Slow Extraction at 8GeV

The mitigation of the beam losses in slow extraction is becoming more and more demanding in accelerator applications for HEP as the beam power is gradually increasing. The successful demonstration of using the proton beam channeling at 450GeV to deflect the beam away from the extraction septa opens the new levels of improving the slow extraction efficiency. It is yet to be demonstrated that this method is still effective at low and medium proton beam energies. Here we present the promising results of the recent computer simulation studies of the septum shadowing at 8GeV for the Mu2e project slow extraction at Fermilab. Depending on the beam parameters the beam loss reduction is shown to be achievable in the range of 1/3 to factor of 3.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Overview on Current Activities of Conduction-Cooled SRF Accelerators and their Applications

When Nb3Sn was reintroduced to the SRF community as an alternative to pure niobium, one key motivation has been to reduce the cryogenic requirements of new and existing accelerators by shifting from 2 K to 4 K operation. Meanwhile, a variety of implementations beyond research machines are being explored. The combination of Nb3Sn with conventional cryocoolers, enabling cryogen-free operation, has paved the way for the development of compact, standalone systems suitable for applications far beyond research, such as enhancing the durability of synthetics via crosslinking or sterilizing food and medical equipment, as well as environmental cleanup when it comes to decontaminating liquid and solid waste material. So, while fundamental R&D continues to refine Nb3Sn resonators, exploring improvements such as replacing the niobium substrate with copper, parallel research efforts are investigating how the increased beam power provided by SRF could expand the commercial use of electron beams. This presentation aims to deliver a comprehensive overview of ongoing research efforts to harness the benefits of SRF through Nb3Sn and conduction cooling.

Vennekate, John [Thomas Jefferson National Acceler↗

Radiation Hardened Beam Instrumentations for Multi-mega-watt Beam Facilities

A beam instrumentation is an essential element for the successful operate particle accelerators in which various diagnostics and beam control systems are integrated into beam optics. However, the performance of beam instrumentation is often subject to constraints such as prompt radiation dose, integrated radiation dose, operation (ambient) temperature and humidity, available space, and strength of embedded electromagnetic fields at the monitoring point. These constraints will limit the dynamic range of operational beam parameters, like the maximum achievable beam power. A seamless R\&D effort to develop the radiation hardened beam instrumentation should be made for future multi-MW beam facilities. In this paper, we describes about a radiation hardened beam instrumentation based on the operational experience of the NuMI beam line.

43 PARTICLE ACCELERATORS↗

Window Cooling Studies and Disk Vibration Testing on a Subset of Mo-100 Disks

Production of metastable Technetium-99 (Tc-99m), a radioactive tracer that emits gamma rays, is vital to the medical imaging community. Tc-99m is extracted from the decay of Molybdenum-99 (Mo-99) which has a half-life of about 2-3 days. The work presented in this report is part of the NNSA’s mission to produce Mo-99 commercially, within the US, without the use of highly enriched uranium (HEU) in support of nonproliferation and global security. Los Alamos National Laboratory (LANL) is working with NorthStar Medical Radioisotopes (NMR) on their efforts to produce Mo-99 through the irradiation of Mo-100 targets using an electron beam. The NMR target comprises a stack of approximately 60-70 Mo-100 disks with diameter 24 mm and thickness 0.74 mm held in stainless steel laminations, each separated using 0.25 mm thick stainless-steel spacers. The symmetric target stack is housed in an Inconel vessel with two Inconel windows on either side. Two electron accelerators are used to produce 40 MeV, 3.16 µA electron beams each that penetrate the Inconel windows and irradiate the Mo-100 disks. Approximately 90% of the total 250 kW beam power is deposited in the NMR target during the irradiation process, with a smaller percentage adding up to 2.2 kW of heat deposited on the Inconel window. During irradiation, pressurized helium gas flows through thin gaps between the disks cooling the beam window, target disks, disk laminations and spacers. Both NMR and LANL have found during cold testing of the target system (no heat deposition) that the Mo 100 disks undergo significant mass loss and disk breakage due to vibrations induced by the flowing helium gas. The mass loss is not only undesirable due to monetary loss from reduced final quantities of Mo-99, but also due to the hazards associated with radioactive material trapped in the cooling lines and particle filters. The effect of flow rate and target geometry on the flow induced vibrations need to be quantified, and recommendations provided to minimize this mass loss. LANL has previously also tested NMR’s Inconel beam window by heating the window, while flowing pressurized helium, using the average heat deposited on the window. However, the NMR beam is pulsed with a duty cycle of 12.5%, which introduces oscillation in temperature around the nominal 600 °C steady state value with each pulse. Available fatigue curves for Inconel are few, established for room temperature, and they are based on mechanical strain cycles not thermally induced strain as in the NMR target. The effect of pulsed beam heating on the Inconel window therefore needs to be quantified. This report details the experiments conducted to assess the factors that lead to mass loss in the NMR target disks as well as to understand the effect of a pulsed beam on NMR’s Inconel window. This work describes LANL’s experimental characterization of the flow induced vibrations and disk mass loss in a reduced scale set-up containing 5 to 10 Mo-100 disks. We use high speed imaging, displacement measurements and microphone measurements combined with signal processing to estimate the vibration frequency of each disk. The effect of disk thickness, target fit and duration of testing on the mass loss is described. We find that in the current configuration of NMR targets, the vibrations and mass loss on the first disk are minimized, while those in the adjacent disks are highest. The microphone and high-speed image data show that increased flow rates and increased duration of testing increases vibration frequency and mass loss. The mass loss is due to both disk rotation and back and forth motion. There are visible wear marks on the disks with the highest mass loss. We also note that the current NMR window gap reduces flow induced vibrations compared to the previous smaller gaps. Improved target holders significantly reduce disk mass loss to almost negligible quantities. This work finds that the larger window to first disk gap and improved target holder geometry should allow NMR to successfully conduct irradiations with minimal mass loss. The window tests were conducted to understand the effect of a pulsed beam on both the window longevity and to estimate the window temperature and displacement during pulsing. The experiments presented here were performed at significantly low power, due to the limitations of the induction heating system. The window temperature rose to approximately 73 °C with a significantly reduced power of 45 W without beam pulsing. With a 5 Hz pulse rate, 12.5% duty cycle, the window temperature remained constant at 26 °C. These experiments will be repeated with improved coil geometry and reported in upcoming journal papers.

42 ENGINEERING↗

Real-time monitoring of the orthohydrogen fraction in a liquid hydrogen moderator

Here, we present the first direct measurements of the orthohydrogen fraction in an operating liquid hydrogen moderator loop at a high-powered neutron source. We have developed a Raman immersion probe capable of characterizing the orthohydrogen and parahydrogen makeup of a liquid hydrogen loop approximately every ten seconds, which can see orthohydrogen fractions lower than 0.20 without difficulty. At the Spallation Neutron Source, where the time-averaged power deposition in the studied moderator system is around 0.02 W/cm 3 , the orthohydrogen fraction increases with beam power and equilibrates at levels of 0.40 and responds to beam trips in a dynamic fashion. Additionally, we find that without deliberate catalyst systems in place, the relaxation due to the piping in the system has insignificant effect in catalyzing the relaxation of freshly condensed hydrogen toward thermodynamic equilibrium, and that the radiation levels associated with activation in a non-operating spallation neutron source target-moderator-reflector assembly likewise has insignificant effect on the liquid hydrogen kinetics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Commissioning of the Advanced Rare Isotope Separator ARIS at FRIB

The Facility for Rare Isotope Beams (FRIB) at Michigan State University (MSU) consists of a newly constructed linear accelerator and fragment separator that are designed for enhanced production rates of rare isotopes for use in research and other societal applications. Recent activities through to August 2022 took place to commission the Advanced Rare Isotope Separator (ARIS) and carry out the first experiments. This followed commissioning of the newly constructed linac that is designed to provide orders of magnitude higher beam power than the previously coupled cyclotrons. This required that more advanced target, beam dump, and collimation systems of the new separator be designed and constructed to sustain unprecedented conditions by heavy ion beams. Commissioning with ~1 kW beams began recently and results from activities that began in late 2021 are reported here. Comparisons between the previous and current facilities are provided.

43 PARTICLE ACCELERATORS↗