Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Telemetry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Demand Response Optimization and Management System for Real-TIme (DROMS-RT)

To design and demonstrate DROMS-RT, a highly distributed Demand Response Optimization and Management System for Real-Time (DROMS-RT) power flow control to support large scale integration of distributed renewable generation into the grid. AutoGrid developed a novel control and communications platform to allow highly dispatchable demand response (DR) services in time frames suitable for providing ancillary services to the transmission grid. These services will be substantially less expensive and more efficient than other forms of ancillary services options currently available to manage the intermittency associated with large-scale renewable integration. DROMSRT successfully leveraged Automated Demand Response (ADR) by fundamentally re-thinking the architecture of the DR platform from the ground up and by developing innovative new technologies in a number of areas related to DR. DROMS-RT leveraged the low-cost, open, interoperable DR signaling technology, OpenADR, and low-cost, internet-protocol based telemetry solutions to reduce the cost of hardware. This allowed DROMS-RT to provide dynamic price signals to millions of OpenADR clients. Statistically rigorous signal processing techniques were developed to reliably detect even small load reductions in the presence of noisy baseline profiles. Novel forecasting engines based on modern online machine learning algorithms enabled accurate individualized forecasts for customer loads in the presence of dynamic pricing signals, and a real-time decision engines enabled continuous optimization and optimal dispatch of DR resources across a large portfolio of heterogeneous loads that respond at varying time-scales. Moreover, the real-time optimization conducted by the decision engine can utilize grid physics to maximize load reduction at the transmission system in addition to the distribution sites, for more efficient grid operation. Finally, the Software-as-a-Service (SaaS) availability of the DROMS-RT platform has reduced the cost of deployment and enable participation of small commercial and residential customers in DR who otherwise would not be able to do so.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Understanding GPU Memory Corruption at Extreme Scale: The Summit Case Study

GPU memory corruption and in particular double-bit errors (DBEs) remain one of the least understood aspects of HPC system reliability. Albeit rare, their occurrences always lead to job termination and can potentially cost thousands of node-hours, either from wasted computations or as the overhead from regular checkpointing needed to minimize the losses. As supercomputers and their components simultaneously grow in scale, density, failure rates, and environmental footprint, the efficiency of HPC operations becomes both an imperative and a challenge. We examine DBEs using system telemetry data and logs collected from the Summit supercomputer, equipped with 27,648 Tesla V100 GPUs with 2nd-generation high-bandwidth memory (HBM2). Using exploratory data analysis and statistical learning, we extract several insights about memory reliability in such GPUs. We find that GPUs with prior DBE occurrences are prone to experience them again due to otherwise harmless factors, correlate this phenomenon with GPU placement, and suggest manufacturing variability as a factor. On the general population of GPUs, we link DBEs to short- and long-term high power consumption modes while finding no significant correlation with higher temperatures. We also show that the workload type can be a factor in memory’s propensity to corruption.

Oles, Vlad↗

Demand Response as a System Reliability Resource

The Demand Response as a System Reliability Resource project consists of six technical tasks: • Task 2.1. Test Plan and Conduct Tests: Contingency Reserves Demand Response (DR) Demonstration—a pioneering demonstration of how existing utility load-management assets can provide an important electricity system reliability resource known as contingency reserve. • Task 2.2. Participation in Electric Power Research Institute (EPRI) IntelliGrid—technical assistance to the EPRI IntelliGrid team in developing use cases and other high-level requirements for the architecture. • Task 2.3. Research, Development, and Demonstration (RD&D) Planning for Demand Response Technology Development—technical support to the Public Interest Energy Research (PIER) Program on five topics: Sub-task 1. PIER Smart Grid RD&D Planning Document; Sub-task 2. System Dynamics of Programmable Controllable Thermostats; Sub-task 3. California Independent System Operator (California ISO) DR Use Cases; Sub-task 4. California ISO Telemetry Requirements; and Sub-task 5. Design of a Building Load Data Storage Platform. • Task 2.4. Time Value of Demand Response—research that will enable California ISO to take better account of the speed of the resources that it deploys to ensure compliance with reliability rules for frequency control. • Task 2.5. System Integration and Market Research: Southern California Edison (SCE)—research and technical support for efforts led by SCE to conduct demand response pilot demonstrations to provide a contingency reserve service (known as non-spinning reserve) through a targeted sub-population of aggregated residential and small commercial customers enrolled in SCE’s traditional air conditioning (AC) load cycling program, the Summer Discount Plan. • Task 2.6. Demonstrate Demand Response Technologies: Pacific Gas and Electric (PG&E)—research and technical support for efforts led by PG&E to conduct a demand response pilot demonstration to provide non-spinning reserve through a targeted sub-population of aggregated residential customers enrolled in PG&E’s AC load curtailment program, the Smart AC™ Demand Response Program.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Decoding Golden Eagle Movement Behavior from High-Resolution, Variable-Rate Telemetry Data Through Bayesian Filtering

The recent advances in animal tracking technology have enabled the collection of a vast amount of in situ data regarding the movement of wildlife at high spatiotemporal resolution. These data are usually available at variable time resolutions and contains noise (error) originating from GPS fixes. Decoding movement characteristics, particularly of flying animals, from telemetry data while handling these factors is a challenging yet important task for conservation purposes. Typically, this task is broken into two subtasks: resampling, and model calibration. The resampling subtask converts the variable rate positional data into a constant time interval data, while the model calibration subtask uses the resampled data to tune time-invariant parameters of the proposed models. For telemetry data at high temporal resolutions (order of 1 second), it is very challenging to decouple noise from actual movements using interpolation-based resampling techniques. Any errors introduced during resampling can significantly alter the the calibration and prediction attributes of the movement model. We address this problem through a unified Bayesian state-space framework that can handle both the resampling and calibration tasks in a single step. In addition, we use the speed and heading of the bird from telemetry data to regularize the position information of the bird. We use a Kalman filtering approach to include these nonlinearly related motion parameters within the state space framework. We cross-validated to quantify how this inclusion affects the model performance in estimating true bird movements. The relationship between the true state of the bird and environmental and topographical covariates is then represented parametrically. These parameters are then tuned using stochastic sampling strategies like Markov Chain Monte Carlo (MCMC). We use the telemetry data collected from golden eagles in the western USA to demonstrate the applicability of this approach to build a predictive, probabilistic movement model. Our preliminary results show that this approach provides improved predictive performance in terms of capturing higher-order motion parameters such as angular and horizontal accelerations, which may have simpler and more direct relationships with environmental covariates than corresponding speeds. In this talk, we will demonstrate how this state-space approach benefits the prediction capabilities of a movement model in simulating golden eagle paths through a wind power plant in Wyoming given certain atmospheric conditions. The model outcomes are aimed at informing mitigation strategies that can minimize the potential for collisions of golden eagles with wind turbines.

Bayesian methods↗

Survival and Passage of Yearling Chinook Salmon and Steelhead at The Dalles Dam, Spring 2011(FINAL REPORT)

The study reported herein was conducted by the Pacific Northwest National Laboratory (PNNL) and the University of Washington (UW) for the U.S. Army Corps of Engineers, Portland District (USACE). The PNNL and UW project managers were Drs. Thomas J. Carlson and John R. Skalski, respectively. The USACE technical lead was Mr. Brad Eppard. The study was designed to estimate dam passage survival and other performance measures at The Dalles Dam as stipulated by the 2008 Federal Columbia River Power System Biological Opinion (BiOp) and the 2008 Columbia Basin Fish Accords. The study is being documented in two types of reports: compliance and technical. A compliance report is delivered within 6 months of the completion of the field season and focuses on results of the performance metrics outlined in the 2008 BiOp and Fish Accords. A technical report is produced within the 18 months after field work, providing comprehensive documentation of a given study and results on route-specific survival estimates and fish passage distributions, which are not included in compliance reports. This technical report concerns the 2011 acoustic telemetry study at The Dalles Dam.

Johnson, Gary E.↗

In service inspection and repair of sodium cooled ASTRID prototype

In the frame of the large R and D work which is performed for the future ASTRID sodium cooled prototype, In Service Inspection and Repair (ISI and R) has been identified as a major issue to be taken into account in order to enlarge the plant safety, to consolidate its availability and to protect the associated investment. After the first part of pre-conceptual design phase (2008-2012), the running second part of pre-conceptual phase (2013-2015) allows to increase the ISI and R tool ability for immersed sodium structures of ASTRID, at about 200 deg. C, on the basis of consolidated specifications and thanks to their qualification through more and more realistic laboratory tests and simulation with CIVA code. ISI and R items are being developed and qualified during a pluri-annual program which mainly deals with the reactor block structures, the primary components and circuit, and the Power Conversion System. It ensures a strong connection between the reactor designers and inspection specialists, as the optimization of inspectability and repairability is looked at: this already induced specific rules for design, in order to shorten and ease the ISI and R operations, which have been merged into RCC-MRx rules. In the frame of increasing technology readiness level with corresponding performance demonstration, this paper presents R and D dealing with the ISI and R items: it highlights the sensor development (both ultrasonic and electromagnetic concepts, compatible with sodium at 200 deg. C), then their applications for ASTRID structure control (under sodium telemetry, imaging and NDE). Activity for repair is also presented (a single laser tool for sodium sweeping, machining and welding), and finally the effort for associated robotic (generic program for ASTRID applications, specific technological tools for sodium medium, tight immersed bell). The main results of testing and simulation are given for telemetry, vision, NDE applications, laser process repair and under sodium sealing. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

220EV Box Truck Telemetry Dataset

This dataset contains telemetry data for the 520EV refuse trucks accessed through a Veracity data platform as provided by Peterbilt. The dataset contains driving data on both electric trucks used by SWS. Data were recorded at an hourly resolution and contain energy use data while driving and idling, distance driven (miles), and driving speed (miles per hour). This dataset also contains charging data on the fast charger in kilowatt-hours for each hour.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

520EV Refuse Truck Telemetry Dataset

This dataset contains telemetry data for the 520EV refuse trucks accessed through a Veracity data platform as provided by Peterbilt. The dataset contains driving data on both electric trucks used by SWS. Data were recorded at an hourly resolution and contain energy use data while driving and idling, distance driven (miles), and driving speed (miles per hour). This dataset also contains charging data on the fast charger in kilowatt-hours for each hour.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Efficacy of Naloxone as a Treatment for an Acute Exposure to Aerosolized Carfentanil

Carfentanil (CRF) is a powerful synthetic opioid that is approximately 100 times more potent than fentanyl and 10,000 times more potent than morphine. CRF originally was intended to be used as a sedative for big game animals in a veterinary setting, but is becoming increasingly common in the illicit drug trade. The increased use of CRF by people has put strain on first responders, who need to administer increased doses of naloxone (Naracan®, Evzio®), an FDA‐approved opioid antagonist, to counteract the effects. First responders may also worry about the potential of self‐exposure through inhalation or dermal contact with CRF. We set out to study the effectiveness of naloxone against a potentially lethal dose of inhaled CRF in male ferrets. Ferrets were implanted with telemetry devices to study cardiac parameters and exposed to aerosolized CRF in a whole‐body plethysmography chamber to record respiratory parameters. We observed profound depression of respiration which resulted in the animals becoming apneic 23% ± 9% of the time during exposure. We also observed cardiac abnormalities, in the form of premature junctional contractions (PJCs), in the ferrets during the apneic periods. At our acute exposure dose, which was lethal in 9% of our animals, ferrets were unresponsive and incapacitated for 105.6 ± 20.0 minutes following the end of exposure. Naloxone, when administered intramuscularly at human equivalent doses ranging from 4 to 40 mg, significantly reduced the time that ferrets were incapacitated following exposure. Although we saw no significant difference in the reduction of time that the animals were incapacitated between the treatment groups (average times between treatment and revival ranged from 6.5 to 9.7 minutes), higher doses of naloxone did revive a portion of the ferrets quicker than the lower doses (some as soon as 1.5–3.5 minutes post‐treatment). We also observed that naloxone was able to significantly reduce the amount of apneic episodes in CRF‐exposed ferrets and resolved the observed cardiac PJCs. Our results suggest that naloxone is a viable treatment against the effects of a potentially lethal dose of inhaled CRF in ferrets. These data have the potential to inform and aid treatment strategies for an acute inhalation exposure to synthetic opioids. Support or Funding Information Opinions, interpretations, conclusions, and recommendations are those of the author and are not necessarily endorsed by the US Army. This research complied with the Animal Welfare Act and implementing Animal Welfare Regulations and adhered to the principles noted in The Guide for the Care and Use of Laboratory Animals. This research was supported by DTRA RD‐CB. M.R. and N.A.A. were supported in part by an appointment to the Postgraduate Research Participation Program at the US Army Medical Research Institute of Chemical Defense administered by the Oak Ridge Institute for Science and Education through an interagency agreement between the US Department of Energy and USAMRMC. This abstract is from the Experimental Biology 2019 Meeting. There is no full text article associated with this abstract published in The FASEB Journal .

McCranor, Bryan J.↗

ADMS Test Bed Updates

This webinar will present results from a joint project with utility partner Xcel Energy in which we evaluated their ADMS application for volt-var optimization using different levels of model quality. We were able to help Xcel Energy understand the trade-offs of telemetry measurements and model quality when managing a feeder's voltage profile to maximize energy conservation. We simulated scenarios with varying levels of model quality and measurement density to evaluate Xcel's options for best using its ADMS. The results help Xcel and other utilities understand how network data affects voltage management as grid operations see continued growth in solar photovoltaic (PV) systems and electric vehicles (EVs).

ADMS↗

Compliance Monitoring of Yearling Chinook Salmon and Juvenile Steelhead Survival and Passage at Bonneville Dam, Spring 2011

The purpose of this compliance study was to estimate dam passage survival of yearling Chinook salmon and steelhead smolts at Bonneville Dam during spring 2011. Under the 2008 Federal Columbia River Power System Biological Opinion (BiOp), dam passage survival should be greater than or equal to 0.96 and estimated with a standard error (SE) less than or equal to 0.015. The study also estimated smolt passage survival from the forebay 2 km upstream of the dam to the tailrace 1 km below the dam, as well as the forebay residence time, tailrace egress, and spill passage efficiency, as required in the Columbia Basin Fish Accords. A virtual/paired-release design was used to estimate dam passage survival at Bonneville Dam. The approach included releases of acoustic-tagged smolts above Bonneville Dam that contributed to the formation of a virtual release at the face of the dam. A survival estimate from this release was adjusted by a paired release below Bonneville Dam. A total of 7692 yearling Chinook salmon and 7766 steelhead smolts were tagged and released during the study. The Juvenile Salmon Acoustic Telemetry System (JSATS) tag model number ATS-156dB, weighing 0.438 g in air, was used in this investigation. The high flows during spring 2011 disrupted planned 100 kcfs spill operations at Bonneville Dam. Therefore, dam passage survival was estimated for the early part of the study (i.e., 30 April–13 May) when spill was about 100 kcfs and for the entire season, which included much higher spill levels from 18–31 May 2011.

Skalski, J. R.↗

VOLTTRON-Based System for Providing Ancillary Services with Residential Building Loads

Ancillary services entail controlled modulation of building equipment to maintain a stable balance of generation and load in the power system. Ancillary services include frequency regulation and contingency reserves, whose acting time ranges from several seconds to several minutes. Many pilot studies have been implemented to use industrial loads to provide ancillary services, and some have explored services from commercial building loads or electric vehicle charging loads. Residential loads, such as space conditioning and water heating, represent a largely untapped resource for providing ancillary services. The residential building sector accounts for a significant fraction of the total electricity use in the United States. Many loads in residential buildings are flexible and could potentially be curtailed or shifted at the request of the grid. However, there are many barriers that prevent residential loads being widely used for ancillary services. One of the major technical barriers is the lack of communication capabilities between end-use devices and the grid. End-use devices need to be able to receive the automatic generation control (AGC) signal from the grid operator and supply certain types of telemetry to verify response. With the advance of consumer electronics, communication-enabled, or 'connected,' residential equipment has emerged to overcome the communication barrier. However, these end-use devices have introduced a new interoperability challenge due to the existence of numerous standards and communication protocols among different end devices. In this paper, we present a VOLTTRON-based system that overcomes these technical challenges and provides ancillary services with residential loads. VOLTTRON is an open-source control and sensing platform for building energy management, facilitating interoperability solutions for end devices. We have developed drivers to communicate and control different types of end devices through standard-based interfaces, manufacturer-provided application programming interfaces, and proprietary communication interfaces. We document the ability to manage nine appliances, using four different standards or proprietary communication methods. A hardware-in-the-loop test was performed in a laboratory environment where the loads of a laboratory home and a large number of simulated homes are controlled by an aggregator. Upon receipt of an AGC signal, the VOLTTRON home energy management system (HEMS) of the laboratory home adjusts the end-device controls based on the comfort criteria set by the end users and sends telemetry to the aggregator to verify response. The aggregator then sends the AGC signal to other simulated homes in attempts to match the utility request as closely as possible. Frequency regulation is generally considered a higher value service than other ancillary services but it is also more challenging due to the constraint of short response time. A frequency regulation use case has been implemented with the regulation signals sent every 10 seconds. Experimental results indicate that the VOLTTRON-controlled residential loads are able to be controlled with sufficient fidelity to enable an aggregator to meet frequency regulation requirements. Future work is warranted, such as understanding the impact of this type of control on equipment life, and market requirements needed to open up residential loads to ancillary service aggregators.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Estimating snow cover from high-resolution satellite imagery by thresholding blue wavelengths

We report the extent and duration of snow cover, a critical component of the hydrologic cycle and the global climate system, is expected to shift dramatically under climate change. Therefore, developing high-resolution assessments of snow cover change is crucial for estimating the impact of changing snow cover on watershed and ecosystems processes in cold regions. Remote sensing tools provide a powerful method for mapping snow-covered area (SCA) across a landscape. The most common method for estimating SCA utilizes the normalized difference snow index (NDSI), which relies on spectral measurements in the shortwave-infrared wavelengths (SWIR). NDSI can effectively estimate catchment- to regional-scale SCA, but it cannot be used to assess fine-scale SCA because of current limitations on the spatial resolution of satellite-derived SWIR measurements. Here, we map SCA using a threshold of blue wavelengths and high-resolution satellite imagery. The thresholding method, which we call the Blue Snow Threshold algorithm (BST), has previously been used with digital camera imagery. We refine and automate the algorithm for use with cloud-free high-resolution satellite imagery and find that the BST can be used to assess fine-scale SCA. For validation, we compared BST-derived estimates of SCA to a) airborne lidar surveys, b) Landsat fractional SCA, and c) snow disappearance dates from Snow Telemetry (SNOTEL) stations. When compared to airborne lidar surveys of SCA, the BST predicted SCA had a range of F-scores between 0.81 and 0.94 in four study areas in California and Colorado. We also found general agreement between SCA and snow disappearance at multiple SNOTEL sites across the western United States. Given the relatively recent availability of high-resolution satellite imagery with spectral measurements in the visible wavelengths but lacking in SWIR, the BST offers a reliable and easy-to-apply tool for examining fine-scale snow-related processes.

54 ENVIRONMENTAL SCIENCES↗

Intra-hour Solar Irradiance Forecast in Multiple Locations using Deep Transfer Learning

In recent years, solar power system installation imposes several challenges on the operations of local and regional power grids due to the inherent variability of ground-level solar irradiance. This work proposes a novel real-time solar forecast methodology for intra-hour solar irradiance based on deep transfer learning from ground-based sky imager for time horizons ranging from 5-15 min. There are three unique aspects of the proposed methodology: (1) a Deep Learning based algorithm development which is modeled as a classification approach rather than a traditional regression approach; (2) the use of the Transfer Learning technique to show generalization capability, robustness, and portability of baseline model in the newly deployed location where availability of enough data for training is typically scarce, and (3) redefinition of point-based irradiation forecast error estimation technique with a window-based one that is more intuitive and user-friendly. The system is developed using multiple years of irradiance and sky image recording in New Jersey and one-year data from Colorado, USA. The method is validated against ground telemetry from these two locations of diverse geographic and climatic conditions. Results show that the forecasting method proposed in this work is robust and highly accurate (8% MAPE error) for multiple locations deployment.

Deep Learning, Convolution Neural Networks, transf↗

Improving Operational Efficiency, Compliance and Community Perception with Real-time Data - 19260

The nuclear and medical radiation industry has always faced a significant burden in effectively balancing exposure and productivity. Maintenance operations and development of new techniques require significant staffing resources to monitor and review personnel exposures and changes in operational radiation levels. Currently utilised monitoring technology and review techniques remain unchanged since the 1950's, relying upon mostly analogue instrumentation and paper reporting. After utilising isolated-area monitoring during a reactor decommissioning project it became apparent that current systems created false assurance as the units continually failed without warning due to 'dirty' power. These instrument failures could have easily led to an unnecessary exposure while operators continued to assume they were being safely monitored. This paper is a philosophical discussion on how current shortcomings could be addressed, security increased, and exposure risks minimised, by utilising real-time monitoring and automated reporting. The community and media expectations of reported data and nuclear monitoring systems continue to be coloured by sensational technology seen in movies and emerging technology available through smart homes and smart cities initiatives. For the general public to be more engaged with real radiation levels and effects, the nuclear industry needs to more effectively communicate safe levels. Organisations can have regain control of exposure levels discussions through the controlled release of background and expected exposure level data. An increase in real world monitoring data communicated in a controlled and more effective way will aid in the general public accepting, and being educated about, the minimal increase above natural background levels of the nuclear industry and other radiation facilities. This is particularly as Australia is in the process of implementing its Nuclear Waste Facility, with community acceptance the number one inhibitor of being able to move forward. Storage, mobile assets, and processing all present unique management, security, exposure, and telemetry challenges for a facility operations manager. Active monitoring and automated review of the monitoring data can alert operators to any unexpected events before any resultant increases in radiation levels cause an unplanned exposure to operators or the environment. Integration of radiation monitoring data with global positioning telemetry enables better organisational awareness of mobile asset location and early detection of any potential shifting and reduction in shielding integrity of sources and encapsulated waste during transport. Additionally, the real-time monitoring can be set-up to enhance an organisations' or nation's security capabilities. For instance, the real time monitor will send an automated alert in the case of an unexpected movement of a source through a monitored facility or for an unscheduled movement of a monitored vehicle. There are further benefits to be gained in control, ALARA principles and effluent management by increasing real-time monitoring capabilities through the stages of the waste cycle. Increasing operational effectiveness while delivering operational cost savings sounds like an attractive proposition. With increased access to operational area radiation data comes drastically improved real-time management of exposures for new, and experimental practices. Increased live data can be utilised to identify optimum practices for reducing operational and environmental exposures or releases. This increased operational data effectively comes with the added benefit of a reduction in the required health physics personnel resources for general operations. By reducing exposure and the detachment of required health physics resources from routine operations, there is greater availability for these resources to support maintenance operations and project-based work. The review of this increased data will create internal capability to identify low-- and high-risk activities, resulting in the ability to reduce the number of highly skilled workers in an industry where the availability of this talent is declining. During my time as the Radiation Safety and Nuclear Security Manager at a research facility, I implemented a real-time monitoring system. The system identified a secondary risk that had previously been unidentified and posed a higher exposure and security risk than the radiation practice being monitored. What stops industry from implementing technology that encourages agile work practices, while minimising security risks and personnel exposure? (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comparison of Actual Costs to Integrate Commercial Buildings with the Grid

During the past decade, the technology to automate demand response (DR) in buildings and industrial facilities has advanced significantly. Automation allows rapid, repeatable, reliable operation. This study focuses on costs for DR automation in commercial buildings with some discussion on residential buildings and industrial facilities. DR automation technology relies on numerous components, including communication systems, hardware and software gateways, standards-based messaging protocols, controls and integration platforms, and measurement and telemetry systems. This paper discusses the impact factors that contribute to the costs of automated DR systems, with a focus on OpenADR 1.0 and 2.0 systems. In addition, this report compares cost data from several DR automation programs and pilot projects, evaluates trends in the cost per unit of DR and kilowatts (kW) available from automated systems, and applies a standard naming convention and classification or taxonomy for system elements. In summary, median costs for the 56 installed automated DR systems studied here are about $200/kW. The deviation around this median is large with costs in some cases being an order of magnitude greater or less than median. Costs to automate fast DR systems for ancillary services are not fully analyzed in this report because additional research is needed to determine the total such costs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Survival Rates of Juvenile Salmonids Passing Through the Bonneville Dam and Spillway in 2008

This report describes a 2008 acoustic telemetry survival study conducted by the Pacific Northwest National Laboratory for the Portland District of the U.S. Army Corps of Engineers. The study estimated the survival of juvenile Chinook salmon and steelhead passing Bonneville Dam (BON) and its spillway. Of particular interest was the relative survival of smolts detected passing through end spill bays 1-3 and 16-18, which had deep flow deflectors immediately downstream of spill gates, versus survival of smolts passing middle spill bays 4-15, which had shallow flow deflectors.

13 HYDRO ENERGY↗