Small-Signal Stability Support from Dynamically Configurable Grid-Forming/Following Inverters for Distribution Systems: Preprint

As the penetration of inverter-based resources (IBRs) continues to increase in modern power systems, system stability is challenged by the insufficient inertia induced by IBRs; hence, there is a need to develop various methods to address the potential instabilities. In this paper, grid-forming (GFM) and grid-following (GFL) controls are implemented for inverters with flexible-mode transitions between them. The operation mode transition between GFM and GFL controls is adopted as an additional degree of control flexibility to adjust the small signal stability margin. Further, a holistic and detailed small signal model of the entire system with the dynamics from both synchronous generators (SGs) and IBRs is derived. The effectiveness of the proposed work in adjusting the system small signal stability margin is validated by conducting case studies with varying penetration levels of IBRs. A test system with one SG and five inverters was implemented in MATLAB/Simulink to demonstrate the effectiveness of the proposed approach. Index Terms - grid-following control, grid-forming control, operation mode transition, small-signal stability analysis

grid-following control↗

Stability of large DC power systems using switching converters, with application to the international space station

As space direct current (dc) power systems continue to grow in size, switching power converters are playing an ever larger role in power conditioning and control. When designing a large dc system using power converters of this type, special attention must be placed on the electrical stability of the system and of the individual loads on the system. In the design of the electric power system (EPS) of the International Space Station (ISS), the National Aeronautics and Space Administration (NASA) and its contractor team led by Boeing Defense & Space Group has placed a great deal of emphasis on designing for system and load stability. To achieve this goal, the team has expended considerable effort deriving a dear concept on defining system stability in both a general sense and specifically with respect to the space station. The ISS power system presents numerous challenges with respect to system stability, such as high power, complex sources and undefined loads. To complicate these issues, source and load components have been designed in parallel by three major subcontractors (Boeing, Rocketdyne, and McDonnell Douglas) with interfaces to both sources and loads being designed in different countries (Russia, Japan, Canada, Europe, etc.). These issues, coupled with the program goal of limiting costs, have proven a significant challenge to the program. As a result, the program has derived an impedance specification approach for system stability. This approach is based on the significant relationship between source and load impedances and the effect of this relationship on system stability. This approach is limited in its applicability by the theoretical and practical limits on component designs as presented by each system segment. As a result, the overall approach to system stability implemented by the ISS program consists of specific hardware requirements coupled with extensive system analysis and hardware testing. Following this approach, the ISS program plans to begin construction of the world's largest orbiting power system in 1997.

Manners, B.↗

A Generic and Multifunctional Electromagnetic Transient Model for Grid-Following Inverters

This paper presents a generic and multifunctional electromagnetic transient (EMT) dynamic model of grid-following (GFL) inverter-based resources (IBRs) using the PSCAD software platform. The features of the model include flexibility in selecting various types and combinations of DC sources covering photovoltaic modules, battery modules, and ideal DC-source modules as well as flexibility in selecting either switching or averaged models of the inverter. This model also covers exhaustive lists of controller algorithm, including open-loop/closed-loop PQ dispatch control, DC voltage and AC terminal voltage control, and conventional current control designed in the dq-domain, the ..alpha....beta.. -domain, and the positive-/negative-sequence domain. Moreover, this model is equipped with flexibility in selecting various types of current-limiting schemes, including saturation-based and latching-based current limiters, and anti-windup protection. Also, the EMT model is agnostic to the MVA rating and is suitable for interfacing transmission systems by complying with IEEE Std. 2800. The generality in the power circuits and the multifunctional options in the operation and control of the developed EMT model make it suitable for both academia and industry to study various power system aspects, including, but not limited to, the fault behavior of GFL IBRs, the impacts on the protection system, and the transient stability of a system interfaced with large numbers of GFL IBRs.

integrated circuit modeling↗

Interactive Power to Frequency Dynamics Between Grid-Forming Inverters and Synchronous Generators in Power Electronics-Dominated Power Systems

With increased attention on grid-forming inverters as a power system stabilizing device during high shares of inverter-based resource operations, there is a present need for a transparent and methodical investigation of the inverted and direct power to frequency control capabilities and impacts of these devices on emerging power systems. Here, analysis of the frequency dynamics of the droop-controlled grid-forming inverter and the synchronous generator illuminates the inverted active power-frequency relationship and the frequency response order reduction, forming the basis for novel, nonlinear frequency control approaches. Device-level electromagnetic transient domain simulations corroborate the order-reduction findings, establish that a properly designed dc-side system has a negligible impact on power transfer and will not impede frequency regulation, and confirm the primary frequency response improvement with nonlinear control. Simulations of the 9- and 39-bus test systems validate the order reduction and associated decoupling of the nadir and rate of change of frequency in larger networks. Oscillatory mode analysis confirms the grid-forming benefit of increased damping; decreased damping is observed at shares above 80%, but not at 100%. Finally, simulations on a validated Maui power system model with a 96% of inverter-based resources model yield a trend toward a first-order response.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Small-Signal Angle Stability-Oriented False Data Injection Cyber-Attacks on Power Systems

The small-signal angle stability (SSAS) of a power system is determined by the property of operation points. The widely applied false data injection (FDI) cyber-attack, however, is able to stealthily mislead the optimal power flow (OPF) and thus compromise operation points, leading to damages to the SSAS margin. Here, to provide insights for cyber defenders, this paper proposes and investigates a stealthy SSAS-oriented FDI cyber-attack focusing on two attacking purposes, i.e., the SSAS margin and operation cost, with higher priority on the former one. First, this paper establishes a novel bi-level model with an implicit SSAS constraint based on a structure preserving model to compromise operation points. Then, for the SSAS interarea mode in a typical two-area system, this paper formulates closed-form expressions of how the SSAS margin and operation cost behave with respect to stealthy injections. By comparison, for the SSAS local mode in general power systems, this paper proposes a moving target cyber-attack-based hierarchical solution algorithm. Simulation results on a two-area system, a Kundur 11 bus system, and a modified IEEE 14 bus system demonstrate the significant damaging effects of the proposed SSAS-oriented FDI cyber-attack and the conflict between the two attacking purposes.

Benders decomposition↗

Inter-Area Oscillation Damping with Type-5 Wind Power Plant

This paper investigates the potential of using brushless excitation (BLE) for not only riding through the fault but also to damp inter-area power oscillation with the help of a synchronous generator (SG) used in Type 5 Wind Power Plant (WPP). In BLE, an auxiliary synchronous generator (ASG) behaving like an exciter is coupled and driven by the rotor of the main SG. The BLE's field current's ASG is fed by two separate loops of the automatic voltage regulator (AVR) and power system stabilizer (PSS). The AVR system implements a control loop to regulate the generator terminal voltage, VT. For the PSS, the kinetic energy of the wind turbine is utilized according to the estimated rotational speed of the synchronous generator shaft of the SG. It may mitigate the necessity of any curtailment of active power for damping. The effectiveness of the proposed control scheme is verified with a three-phase short circuit fault in a two-area power system.

brushless↗

Inter-Area Oscillation Damping with Type-5 Wind Power Plant: Preprint

This paper investigates the potential of using brushless excitation (BLE) for not only riding through the fault but also to damp inter-area power oscillation with the help of a synchronous generator (SG) used in Type 5 Wind Power Plant (WPP). In BLE, an auxiliary synchronous generator (ASG) behaving like an exciter is coupled and driven by the rotor of the main SG. The BLE's field current's ASG is fed by two separate loops of the automatic voltage regulator (AVR) and Power System Stabilizer (PSS). The AVR system implements a control loop to regulate the generator terminal voltage, VT. For the PSS, the kinetic energy of the wind turbine is utilized according to the estimated rotational speed of the synchronous generator shaft of the SG. It mitigates the necessity of any curtailment of active power for damping. The effectiveness of the proposed control scheme is verified with a three-phase short circuit fault in a two-area power system.

brushless↗

Investigating the Impact of Wind Turbines on Distribution System Stability

Modern wind turbines utilize power electronic converters to regulate their output and optimize their performance. Their impact on the distribution system is not as well understood as for transmission system. The novelty of this work is in studying the impact of wind turbines given its proximity to faults or severe voltage events, and the influence on system stability given its location relative to the substation (representing the conventional grid). This paper presents the frequency and voltage swing plots for various study scenarios. The responses are analyzed two fold - Steady state operation, and performance given a fault or voltage events occurs in the system. The findings are presented, with crucial differences from transmission systems highlighted.

17 WIND ENERGY↗

Real Time Applications Using Linear State Estimation Technology (RTA/LSE)

Electric Power Group, LLC (EPG) was awarded DOE OE0000849 to design, develop, and demonstrate three real-time applications for monitoring power system stability. The applications use phasor measurements and processing by a linear state estimator (LSE) to improve system visibility and accuracy. These applications leverage the large and expanding phasor measurement systems being deployed by utilities throughout the world, and specifically in the United States. Phasor measurements provide a much more detailed view of the power systems than traditional SCADA systems, so can provide better visibility of events and an early warning of developing problems. These three applications are real-time contingency analysis (RTCA), area angle monitoring (AAM), and a voltage stability index (VSI). The project was fully completed as proposed. All three applications were successfully implemented and demonstrated. There were challenges the caused project delays, however. While the RTCA is based on well-known concepts and readily available tools, its deployment using phasor measurements meant it needed to be adapted to sometimes sparse measurements and limited coverage areas. EPG met these challenges with extensive modeling and testing. The AAM is based on unproven research, so EPG had to deal with a lot of unknowns and develop additional methods for practical implementation. These activities took more time than anticipated, so required extra time for development. In addition, there was difficulty getting adequate measurement locations for successful deployment and utility installation delays. Consequently, the project required a time extension to complete. These three real-time applications, RTCA, AAM, and VSI, use only phasor measurement input. Since they do not require the EMS or other measurement systems, they can serve as a backup and security check for the EMS. Phasor measurements are validated and extended by an LSE. The LSE will always produce an output even when some inputs are impaired, so the RT applications will operate even when the EMS state estimator does not converge and the applications it supports cannot function. Consequently, these RT applications can provide valuable additional reliability for control center operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High Penetration Microgrids Providing Grid Stability Using Frequency-Watt Control Presentation

The U.S. grid is rapidly transitioning towards utilizing inverter-based renewable energy resources such as solar, wind, and batteries, reducing the carbon emission footprint.Inverter-based microgrid control architectures remain a critical focus to address power system stability issues in future high penetration markets lacking spinning generation assets. Idaho National Laboratory (INL) is researching an active layered inverter based frequency-Watt control scheme that provides distribution level stability in high-penetration markets where grid inertia is lacking. Hardware in the loop case study was implemented using INL’s Microgrid Testbed to combat scalable frequency deviations ranging from 60 Hz down to 50 Hz initialized by a hydropower model implementing step loads using a 540-kW grid emulator. Our research findings demonstrate the importance of distribution level, inverter-based active frequency-Watt controls utilizing a battery energy storage system (BESS) to provide adequate frequency support at the point of common coupling without major power infrastructure upgrades.

13 HYDRO ENERGY↗

High-Penetration Microgrids Providing Grid Stability Using Frequency Watt Control

The U.S. grid is rapidly transitioning towards utilizing inverter-based renewable energy resources such as solar, wind, and batteries, reducing the carbon emission footprint. Inverter-based microgrid control architectures remain a critical focus to address power system stability issues in future high penetration markets lacking spinning generation assets. Idaho National Laboratory (INL) is researching an active layered inverter based frequency-Watt control scheme that provides distribution level stability in high-penetration markets where grid inertia is lacking. Hardware in the loop case study was implemented using INL’s Microgrid Testbed to combat scalable frequency deviations ranging from 60 Hz down to 50 Hz initialized by a hydropower model implementing step loads using a 540-kW grid emulator. Our research findings demonstrate the importance of distribution level, inverter-based active frequency-Watt controls utilizing a battery energy storage system (BESS) to provide adequate frequency support at the point of common coupling without major power infrastructure upgrades.

14 SOLAR ENERGY↗

Grand Challenges in Modeling, Simulation and Analysis: Extraction and Visualization of Power Systems

Threats to the national electric power grid often require the coupling of real-time state data with look-ahead or forecasting models to provide timely disruption warnings. However, successful accomplishment of this capability presents a grand challenge in modeling, simulation, and analysis. Analysis of inter-area oscillatory modes may provide a new path to anticipate power system stability and address this grand challenge. An algorithm is presented for the identification and analysis of such modes from high resolution phasor measurement data that might indicate a pathway to meet this grand challenge. The process outlined includes data collection, conditioning, extraction of the primary oscillatory frequency, and determination of participating areas of the system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of Wind Turbine Simulation Models: Assessment of Simplified versus Complete Methodologies: Preprint

This paper presents the current status of simplified wind turbine models used for power system stability analysis. This work is based on the ongoing work being developed in IEC 61400-27. This international standard, for which a technical committee was convened in October 2009, is focused on defining generic (also known as simplified) simulation models for both wind turbines and wind power plants. The results of the paper provide an improved understanding of the usability of generic models to conduct power system simulations.

17 WIND ENERGY↗

Open-Source PSCAD Grid-Following and Grid-Forming Inverters and a Benchmark for Zero-Inertia Power System Simulations: Preprint

This paper presents open-source, flexible, and easily-scalable models of grid following and grid forming inverters for the PSCAD software platform. The models are intended for system integration studies, particularly stability analyses of power systems with high penetration of inverter-based generation. To verify the model functionality, they are implemented in a IEEE9-bus system in a zero-inertia operational scenario of 100% inverter-based generation. The models have been made available open source at the PyPSCAD NREL GitHub page.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Enhancing the Flexibility of Generation of Run-Of-the-River Hydro Power Plants

Run-of-the-River Hydro Power Plants (ROR HPPs) output can be characterized as fixed and predictable output with low cost of both installation and operation. ROR HPP generation is proportional to the water flow and cannot be adjusted to provide inertia to the grid, which is critical to power systems stability. Hence ROR HPP can only participate in low profit energy markets and not in the high profit ancillary service market. With the advances in energy storage, they can help build a synthetic energy reservoir. The combined operation of ROR HPPs and energy storage are capable of both ramping and variable power output, allowing participation in the ancillary service markets. However, energy storage technologies such as supercapacitors and flywheels, which are power dense can quickly charge/discharge within a short duration. Energy dense storage technologies such as batteries can provide long duration energy injection while the maximum ramping rate is much lower than power dense energy storage. In order to provide long duration fast ramping capability, Hybrid Energy Storage Systems (HESSs) including both power and energy dense energy storage are proposed to be integrated to enable the flexible operation of ROR HPP. Power dense energy storage with quick burst of energy can assist in regulation, whereas energy dense storage can provide energy balance over larger time. In this paper, the properties of different types of energy storage including the ramping rate, affordable energy storage capacity, thermal management, etc. are analyzed. The size of each type of energy storage is determined to ensure optimal combination of HESS and ROR HPP. A generic Front End Controller (FEC) is developed and customized for ROR HPP to provide real time control and cohesive operation of multiple units. FEC serves as the interface between utility management systems and ROR HPPs to ensure their integration with the centralized controls. Using the Automatic Generation Control (AGC) signal received from grid operator, FEC optimizes the ROR HPP turbine and HESS so that the aggregated generation can satisfy the market needs. Based on the study, system operator can acquire extra inertia support for system stability, and the ROR HPP operators can enhance their revenues by participating in wider market avenues.

13 HYDRO ENERGY↗

Data-Driven Security Assessment of Power Grids Based on Machine Learning Approach: Preprint

Data-driven security assessment provides key indicators on power system stability using simulations on scheduling models, as opposed to dynamic simulations that are more time-consuming. This paper investigates data-driven security assessment of power grids based on machine learning. Multivariate random forest regression is used as the machine learning algorithm due to its high robustness to the input data. Three stability issues are analyzed using the proposed machine learning tool, including transient stability, frequency stability and small signal stability. The estimation values from machine learning tool are compared with those from dynamic simulations. Results show that the proposed machine learning tool can effectively predict the stability margins for the three stability metrics.

14 SOLAR ENERGY↗

Photovoltaic Inverter Momentary Cessation: Recovery Process is Key

Momentary cessation refers to an inverter control mode. When the inverter terminal voltage falls below (or exceeds) a certain level, the inverter ceases to output any current, but attempts to maintain (or quickly regain) phase-locked loop synchronization to allow for quick reinjection of current when the voltage recovers to a certain point. This paper presents a photovoltaic (PV) momentary cessation model developed in PSS/E. Simulations are presented for a high voltage transmission line fault contingency in the Hawaiian island of Oahu power system on a validated PSS/E model, modified to include a custom distributed PV inverter model, and different near-future distributed PV penetration levels. Simulations for the island power system include different penetration levels of PV, and different recovery times (ramp rates and delays) after momentary cessation. The results indicate that during low voltage events, such as faults, momentary cessation can produce severe under frequency events, causing significant load shed and shortly thereafter, in some cases, over frequency events that cause generation to trip offline. The problem is exacerbated with higher penetration levels of PV. If momentary cessation is used (as is typically the case for distribution-connected resources), the recovery process after momentary cessation should be carefully considered to minimize impacts to bulk power system stability.

14 SOLAR ENERGY↗

Extraction and Visualization of Power System Interarea Oscillatory Modes

Interarea oscillatory modes pose a threat to power system stability. An algorithm is presented for the identification and analysis of such modes from high resolution phasor measurement data. The entire process is outlined including data collection, conditioning, extraction of the primary oscillatory frequency, and determination of participating areas of the system. Additionally a visualization methodology is presented which displays these results. Using the tools developed here the dominant modes and their associated regions of influence in a power system can be determined directly from measurement data.

24 POWER TRANSMISSION AND DISTRIBUTION↗