Reanalysis of the top-quark pair hadroproduction and a precise determination of the top-quark pole mass at the LHC *

In this study, we calculate the $t\bar{t}$ pQCD production cross-section at the NNLO and determine the top-quark pole mass from recent measurements at the LHC at the center-of-mass energy $\sqrt{S}=13$ TeV to a high precision by applying the principle of maximum conformality (PMC). The PMC provides a systematic method that rigorously eliminates QCD renormalization scale ambiguities by summing the nonconformal $\beta$ contributions into the QCD coupling constant. The PMC predictions satisfy the requirements of renormalization group invariance, including renormalization scheme independence, and the PMC scales accurately reflect the virtuality of the underlying production subprocesses. By using the PMC, an improved prediction for the $t\bar{t}$ production cross-section is obtained without scale ambiguities, which in turn provides a precise value for the top-quark pole mass. Moreover, the prediction of PMC calculations that the magnitudes of higher-order PMC predictions are well within the error bars predicted from the known lower-order has been demonstrated for the top-quark pair production. The resulting determination of the top-quark pole mass, $m_t^{\rm{pole}}=172.5\pm1.4$ GeV, from the LHC measurement at $\sqrt{S}=13$ TeV agrees with the current world average cited by the Particle Data Group (PDG). The PMC prediction provides an important high-precision test of the consistency of pQCD and the SM at $\sqrt{S}=13$ TeV with previous LHC measurements at lower CM energies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The EBLM project – IX. Five fully convective M-dwarfs, precisely measured with CHEOPS and TESS light curves

ABSTRACT Eclipsing binaries are important benchmark objects to test and calibrate stellar structure and evolution models. This is especially true for binaries with a fully convective M-dwarf component for which direct measurements of these stars’ masses and radii are difficult using other techniques. Within the potential of M-dwarfs to be exoplanet host stars, the accuracy of theoretical predictions of their radius and effective temperature as a function of their mass is an active topic of discussion. Not only the parameters of transiting exoplanets but also the success of future atmospheric characterization relies on accurate theoretical predictions. We present the analysis of five eclipsing binaries with low-mass stellar companions out of a subsample of 23, for which we obtained ultra-high-precision light curves using the CHEOPS satellite. The observation of their primary and secondary eclipses are combined with spectroscopic measurements to precisely model the primary parameters and derive the M-dwarfs mass, radius, surface gravity, and effective temperature estimates using the PYCHEOPS data analysis software. Combining these results to the same set of parameters derived from TESS light curves, we find very good agreement (better than 1 per cent for radius and better than 0.2 per cent for surface gravity). We also analyse the importance of precise orbits from radial velocity measurements and find them to be crucial to derive M-dwarf radii in a regime below 5 per cent accuracy. These results add five valuable data points to the mass–radius diagram of fully convective M-dwarfs.

Sebastian, D. (ORCID:0000000222149258)↗

Precise $\textit{Q}$-value measurements of 112,113 Ag and 115 Cd with the Canadian Penning trap for evaluation of potential ultralow $\textit{Q}$-value $\textit{β}$ decays

Background: An ultralow $\textit{Q}$-value $\textit{β}$ decay can occur from a parent nuclide to an excited nuclear state in the daughter such that $Q_{\text{UL}}$ 1 keV. These decay processes are of interest for nuclear $\textit{β}$-decay theory and as potential candidates in neutrino mass determination experiments. To date, only one ultralow $\textit{Q}$-value $\textit{β}$ decay has been observed—that of 115 In with $Q_β$ = 147(10) eV. A number of other potential candidates exist, but improved mass measurements are necessary to determine if these decay channels are energetically allowed and, in fact, ultralow. Purpose: To perform precise $\textit{β}$-decay $\textit{Q}$-value measurements of 112,113 Ag and 115 Cd and to use them in combination with nuclear energy level data for the daughter isotopes 112,113 Cd and 115 In to determine if the potential ultralow $\textit{Q}$-value $\textit{β}$-decay branches of 112,113 Ag and 115 Cd are energetically allowed and 1 keV. Method: The Canadian Penning Trap at Argonne National Laboratory was used to measure the cyclotron frequency ratios of singly charged 112,113 Ag and 115 Cd ions with respect to their daughters 112,113 Cd and 115 In. From these measurements, the ground-state to ground-state $\textit{β}$-decay $\textit{Q}$ values were obtained. Results: The 112 Ag → 112 Cd, 113 Ag → 113 Cd, and 115 Cd → 115 In $\textit{β}$-decay $\textit{Q}$ values were measured to be $Q_β$( 112 Ag) = 3990.16(22) keV, $Q_β$( 113 Ag) = 2085.7(4.6) keV, and $Q_β$( 115 Cd) = 1451.36(34) keV. These results were compared to energies of excited states in 112 Cd at 3997.75(14) keV, 113 Cd at 2015.6(2.5) and 2080(10) keV, and 115 In at 1448.787(9) keV, resulting in precise $Q_{\text{UL}}$ values for the potential decay channels of –7.59(26) keV, 6(11) keV, and 2.57(34) keV, respectively. Conclusion: The potential ultralow $\textit{Q}$-value decays of 112 Ag and 115 Cd have been ruled out. 113 Ag is still a possible candidate until a more precise measurement of the 2080(10) keV, 1/2+ state of 113 Cd is available. In the course of this work we have found the ground state mass of 113 Ag reported in the 2020 Atomic Mass Evaluation [Wang et al., Chin. Phys. C 45, 030003 (2021)] to be lower than our measurement by 69(17) keV (a 4σ discrepancy).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-precision mass measurement of Si 24 and a refined determination of the r p process at the A = 22 waiting point

We report a high-precision mass measurement of 24 Si, performed with the Low Energy Beam and Ion Trap (LEBIT) facility at the National Superconducting Cyclotron Laboratory. The atomic mass excess, 10 753.8 (37) keV, is a factor of 5 more precise than previous results. This substantially reduces the uncertainty of the 23 Al(p ,γ) 24 Si reaction rate, which is a key part of the rapid proton capture (rp) process powering type I x-ray bursts. Furthermore, the updated rate constrains the onset temperature of the (α,p) process at the 22 Mg waiting point to a precision of 9%.

20 ≤ A ≤ 38↗

First direct 7 Be electron-capture $\mathrm{Q}$-value measurement toward high-precision searches for neutrino physics beyond the Standard Model

Here, we report the first direct measurement of the nuclear electron-capture (EC) decay Q value of 7 Be → 7 Li via high-precision Penning trap mass spectrometry (PTMS). This was performed using the LEBIT Penning trap located at the National Superconducting Cyclotron Laboratory/Facility for Rare Isotope Beams (NSCL/FRIB) using the newly commissioned Batch-Mode Ion-Source (BMIS) to deliver the unstable 7 Be + samples. With a measured value of Q EC = 861.963(23) keV, this result is three times more precise than any previous determination of this quantity. This improved precision and accuracy of the 7 Be EC decay Q value is critical for ongoing experiments that measure the recoiling nucleus in this system as a signature to search for beyond the Standard Model (BSM) neutrino physics using 7 Be-doped superconducting sensors. This experiment has extended LEBIT capabilities, using the first low-energy beam delivered by BMIS at FRIB for PTMS, as well as measuring the lightest-mass isotopes so far with LEBIT.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigating the effects of precise mass measurements of Ru and Pd isotopes on machine learning mass modeling

Atomic masses are a foundational quantity in our understanding of nuclear structure, astrophysics, and fundamental symmetries. The longstanding goal of creating a predictive global model for the binding energy of a nucleus remains a significant challenge, however, and prompts the need for precise measurements of atomic masses to serve as anchor points for model developments. We present precise mass measurements of neutron-rich Ru and Pd isotopes performed at the Californium Rare Isotope Breeder Upgrade facility at Argonne National Laboratory using the Canadian Penning Trap mass spectrometer. The masses of 108 Ru, 110 Ru, and 116 Pd were measured to a relative mass precision $\delta$⁢$m/m$ ≈ 10 -8 via the phase-imaging ion-cyclotron-resonance technique, and represent an improvement of approximately an order of magnitude over previous measurements. Further, these mass data were used in conjunction with the physically interpretable machine learning (PIML) model, which uses a mixture density neural network to model mass excesses via a mixture of Gaussian distributions. The effects of our new mass data on a Bayesian-updating of a PIML model are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Precision unification and the scale of supersymmetry

In this paper, we study the implications of precise gauge coupling unification on supersymmetric particle masses. We argue that precise unification favors the superpartner masses that are in the range of several TeV and well beyond. We demonstrate this in the minimal supersymmetric theory with a common sparticle mass threshold, and two simple high-scale scenarios; minimal supergravity and minimal anomaly-mediated supersymmetry. We also identify candidate models with a Higgsino or a wino dark matter candidate. Finally, the analysis shows unambiguously that unless one takes foggy naturalness notions too seriously, the lack of direct superpartner discoveries at the LHC has not diminished the viability of supersymmetric unified theories in general nor even precision unification in particular. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precise absolute 𝛾–ray intensities following the 𝛽 decay of 156 Eu

The most recent 𝛽-decay data for 156 Eu is over 40 years old, and the 𝛾-ray intensities are only known with a fractional precision of about 10% or worse. Here, in this work, we present new results for the absolute intensities of more than 60 𝛾 rays emitted following the 𝛽 decay of 156 Eu with many measured to ≲1% accuracy, representing an order-of-magnitude improvement in precision. This was achieved by leveraging the fission-product beams produced at the CARIBU facility to create radio-pure samples and detecting the radiation with a 4⁢𝜋 𝛽-particle counter coupled with a precisely efficiency-calibrated HPGe detector at Texas A and M University.

Physics - Nuclear physics and radiation physics↗

Automating the Solar Interconnection Technical Evaluation Process: PREconfiguring and Controlling Inverter SEt-Points (PRECISE)

Utilities are receiving an increasing number of interconnection requests for distributed solar photovoltaic (PV) systems from their customers, requiring a solution to quickly and intelligently perform technical assessments of these requests and to manage these new renewable energy assets. In this paper, we present a stand-alone interconnection tool, PREconfiguring and Controlling Inverter SEt-points (PRECISETM), and how it overcomes the challenges of accelerating technical evaluations and leverages smart inverter functionality to provide local voltage support on an as-needed basis. The paper details the purpose and architecture of PRECISE, including tools, data source requirements, the model-based interconnection evaluation process, and technical results. PRECISE is an integrated software tool that customizes PV inverter settings for utilities by modeling and assessing impacts on local voltages and the need for advanced inverter functions (AIFs) (e.g., volt-VAR and volt-watt). PRECISE maximizes the use of readily available utility data sets to make fast online assessments of incoming PV interconnection requests and makes accept/reject recommendations along with custom settings for AIFs.

ENERGY PLANNING, POLICY, AND ECONOMY,SOLAR ENERGY↗

Efficient and Flexible Hierarchical Data Layouts for a Unified Encoding of Scalar Field Precision and Resolution

To address the problem of ever-growing scientific data sizes making data movement a major hindrance to analysis, we introduce a novel encoding for scalar fields: a unified tree of resolution and precision, specifically constructed so that valid cuts correspond to sensible approximations of the original field in the precision-resolution space. Furthermore, we introduce a highly flexible encoding of such trees that forms a parameterized family of data hierarchies. We discuss how different parameter choices lead to different trade-offs in practice, and show how specific choices result in known data representation schemes such as zfp[52], idx[58], and jpeg2000 [76]. Lastly, we provide system-level details and empirical evidence on how such hierarchies facilitate common approximate queries with minimal data movement and time, using real-world data sets ranging from a few gigabytes to nearly a terabyte in size. Experiments suggest that our new strategy of combining reductions in resolution and precision is competitive with state-of-the-art compression techniques with respect to data quality, while being significantly more flexible and orders of magnitude faster, and requiring significantly reduced resources.

97 MATHEMATICS AND COMPUTING↗

Precision luminosity measurement in proton–proton collisions at $\sqrt{s}$ = 13 TeV in 2015 and 2016 at CMS

The measurement of the luminosity recorded by the CMS detector installed at LHC interaction point 5, using proton–proton collisions at √s = 13 TeV in 2015 and 2016, is reported. The absolute luminosity scale is measured for individual bunch crossings using beam-separation scans (the van der Meer method), with a relative precision of 1.3 and 1.0% in 2015 and 2016, respectively. The dominant sources of uncertainty are related to residual differences between the measured beam positions and the ones provided by the operational settings of the LHC magnets, the factorizability of the proton bunch spatial density functions in the coordinates transverse to the beam direction, and the modeling of the effect of electromagnetic interactions among protons in the colliding bunches. When applying the van der Meer calibration to the entire run periods, the integrated luminosities when CMS was fully operational are 2.27 and 36.3 fb -1 in 2015 and 2016, with a relative precision of 1.6 and 1.2%, respectively. These are among the most precise luminosity measurements at bunched-beam hadron colliders.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A precise measurement of the Z -boson double-differential transverse momentum and rapidity distributions in the full phase space of the decay leptons with the ATLAS experiment at $\sqrt{s}=8$ TeV

This paper presents for the first time a precise measurement of the production properties of the Z boson in the full phase space of the decay leptons. This is in contrast to the many previous precise unfolded measurements per formed in the fiducial phase space of the decay leptons. The measurement is obtained from proton–proton collision data collected by the ATLAS experiment in 2012 at $\sqrt{s}$ = 8 TeV at the LHC and corresponding to an integrated luminosity of 20.2 fb -1 . The results, based on a total of 15.3 million Z boson decays to electron and muon pairs, extend and improve a previous measurement of the full set of angular coefficients describing Z-boson decay. The double-differential cross section distributions in Z-boson transverse momentum pT and rapidity y are measured in the pole region, defined as 80 < m ℓℓ < 100 GeV, over the range |y| < 3.6. The total uncertainty of the normalised cross-section measurements in the peak region of the pT distribution is dominated by statistical uncertainties over the full range and increases as a function of rapidity from 0.5–1.0% for |y| < 2.0 to 2 - 7% at higher rapidities. The results for the rapidity-dependent transverse momentum distributions are compared to state of-the-art QCD predictions, which combine in the best cases approximate N 4 LL resummation with N 3 LO fixed-order per turbative calculations. The differential rapidity distributions integrated over pT are even more precise, with accuracies from 0.2–0.3% for |y| < 2.0 to 0.4–0.9% at higher rapidities, and are compared to fixed-order QCD predictions using the most recent parton distribution functions. The agreement between data and predictions is quite good in most cases.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

NCCS High Performance GMRES Mixed Precision

HPG-MxP is a software package that performs a fixed number of multigrid preconditioned (using a Gauss-Seidel smoother) Generalized minimal residual (PGMRES) iterations in order to solve a possibly nonsymmetric large sparse linear system of equations. It is designed to be a benchmark to measure a computer's performance for sparse linear algebra workloads typical in scientific computing while allowing the use of mixed precision methods. The solution is required to have convergence characteristics and accuracy similar to double precision GMRES. It is based on the High Performance Conjugate Gradient Benchmark (HPCG) which restricts all implementations to use only the IEEE double precision format (FP64). The original implementation (https://github.com/hpg-mxp/hpg-mxp) was written by Ichitaro Yamazaki, Jennifer Loe, Christian Glusa, Sivasankaran Rajamanickam, Piotr Luszczek, and Jack Dongarra. Please refer to that repository for documentation on the original implementation. This version is maintained by the National Center for Computational Sciences at Oak Ridge National Laboratory. It is highly scalable and optimized for Oak Ridge Leadership Computing Facility (OLCF) systems, particularly Frontier.

Kashi, Aditya [Oak Ridge National Laboratory (ORNL↗

High-precision millimeter-wave frequency determination through plasmonic photomixing

We present a technique for high-precision millimeter-wave frequency determination through plasmonic photomixing. Our technique utilizes a plasmonic photomixer pumped by an optical frequency comb with a high-stability millimeter-wave beat frequency. The plasmonic photomixer down-converts the millimeter-wave signal to the radio frequency regime at which high-accuracy frequency counters are available. The precision of this technique is determined by the frequency stability of the optical beat frequency, which can be directly characterized in the presented experimental setup. We demonstrate frequency measurement precision as low as 3.9×10 −10 at 95 GHz through plasmonic photomixing without phase-locking the optical frequency comb.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fabrication of silicon-tipped fiber-optic temperature sensors using aerogel-assisted glass soldering with precise laser heating

We demonstrate the fabrication of fiber-optic Fabry–Perot interferometer (FPI) temperature sensors by bonding a small silicon diaphragm to the tip of an optical fiber using low melting point glass powders heated by a 980 nm laser on an aerogel substrate. The heating laser is delivered to the silicon FPI using an optical fiber, while the silicon temperature is being monitored using a 1550 nm white-light system, providing localized heating with precise temperature control. The use of an aerogel substrate greatly improves the heating efficiency by reducing the thermal loss of the bonding parts to the ambient environment. A desirable temperature for bonding can be achieved with relatively small heating laser power. The bonding process is carried out in an open space at room temperature for convenient optical alignment. The precise temperature control ensures minimum perturbation to the optical alignment and no induced thermal damage to the optical parts during the bonding process. For demonstration, we fabricated a low-finesse and high-finesse silicon FPI sensor and characterized their measurement resolution and temperature capability. The results show that the fabrication method has a good potential for high-precision fabrication of fiber-optic sensors.

Sheng, Qiwen↗

Data and Scripts associated with: “Laboratory evaluation of open source and commercial electrical conductivity sensor precision and accuracy”

This data package is associated with the publication “Laboratory evaluation of open source and commercial electrical conductivity sensor precision and accuracy: How do they compare?” submitted to PLOS ONE and accepted for publication (Fulton, S.G. et al. 2023; doi not yet available).Variation in electrical conductivity (EC) of water is important to reveal environmental disturbance and natural dynamics, including factors such as anthropogenic salinization. This data package supports a study addressing the need for a robust performance assessment of open source (OS) EC sensors. We evaluated the accuracy (mean error, %) and precision (sample standard deviation) of OS EC sensors in the laboratory via comparison to EC calibration standards using three different OS and OS/commercial-hybrid (OS/C) EC sensors and data logger configurations and two commercial (C) EC sensors and data logger configurations. We also evaluated the effect of cable length (7.5 m and 30 m) and sensor calibration on OS sensor accuracy and precision. This data package presents the results from the different testing laboratory configurations. It also includes an R script for statistical analysis of the data and an Arduino IDE file used to calibrate and collect data with the OS Atlas EC sensor. File types are .csv, .pdf, .R, and .ino.

54 ENVIRONMENTAL SCIENCES↗

Atomic-precision advanced manufacturing for Si quantum computing

Abstract A materials synthesis method that we call atomic-precision advanced manufacturing (APAM), which is the only known route to tailor silicon nanoelectronics with full 3D atomic precision, is making an impact as a powerful prototyping tool for quantum computing. Quantum computing schemes using atomic ( 31 P) spin qubits are compelling for future scale-up owing to long dephasing times, one- and two-qubit gates nearing high-fidelity thresholds for fault-tolerant quantum error correction, and emerging routes to manufacturing via proven Si foundry techniques. Multiqubit devices are challenging to fabricate by conventional means owing to tight interqubit pitches forced by short-range spin interactions, and APAM offers the required (Å-scale) precision to systematically investigate solutions. However, applying APAM to fabricate circuitry with increasing numbers of qubits will require significant technique development. Here, we provide a tutorial on APAM techniques and materials and highlight its impacts in quantum computing research. Finally, we describe challenges on the path to multiqubit architectures and opportunities for APAM technique development. Graphic Abstract

36 MATERIALS SCIENCE↗

Initial Exploration of the Use of Mixed Precision in Iterative Solvers (B639388 Subcontract Quarter I Report)

The first quarter of the project was primarily spent identifying potential projects at the intersection of finite precision analysis, mixed precision computation, and Krylov subspace methods. We summarize our findings in the remainder of the document. Other activities include attending biweekly xSDK meetings as well as contributing material to the technical report and journal versions of the multiprecision landscape paper. The subsequent quarter will be spent selecting a subset of the described projects to focus on, performing initial numerical experiments to evaluate the potential for the use of mixed precision, and developing initial theoretical analysis.

97 MATHEMATICS AND COMPUTING↗