Modification of Mach 6 Freestream Flow by Pitot Probe Bow Shock as Measured by Line FLDI and SAFS

Measurements of the flow in front of flat-face Pitot probes in NASA Langley ResearchCenter’s 20-Inch Mach 6 Air Tunnel were made using a 35-point line focused laser differentialinterferometer (FLDI), a two-point FLDI, and a self-aligned focusing schlieren system. Thesesystems were used to make measurements of flow unsteadiness between the bow shock andPitot probe face, while also probing the freestream region just upstream of the bow shock.Shock standoff distances from the non-intrusive measurements match closely with analyticalsolutions using the probe face diameter. Acoustic wave angles and velocities in the freestreamcompare favorably with DNS simulations of a Mach 6 freestream flow, and wave velocities in thepost-shock region slow as they approach the probe face. Peak frequencies in the post-shockregion as measured by FLDI compare favorably to the estimates computed from the shockstandoff distance for most probe diameters. With increasing unit Reynolds number, fluctuationintensities in the post-shock region were attenuated below the intensities of the freestream, witha spectral, spatial, and probe size dependence. Pitot probe power spectral density estimatesare presented from the test campaign, which can be compared with FLDI and SAFS data toevaluate the applicability of the transfer functions derived from computational simulations.

Joshua M Weisberger↗

A Multi‐Probe Automated Classification of Ice Crystal Habits During the IMPACTS Campaign

Although all ice crystals are unique, many can be grouped together by shape or habit, with members of a habit class sharing similar representations of properties such as fall velocity and growth rate. A decision tree algorithm designed to be adaptable to any particle imaging probe, thus enabling the creation of habit size distributions over a size range larger than that of any probe on its own, is used to classify ice crystals imaged by three airborne cloud probes in mid-latitude winter cyclones during the Investigation of Microphysics and Precipitation for Atlantic Coast-Threatening Snowstorms (IMPACTS) field campaign. Crystals are sorted into seven habit classes based on their morphological properties: sphere, column/needle, plate, graupel, dendrite, aggregate, and irregular. Although adaptability was its primary goal, the algorithm was found to be moderately skillful for identifying idealized habit images. Quantitative tests of the algorithm’s adaptability displayed mixed results, as Two-Dimensional Stereo Probe (2DS) classifications showed moderate correlation with Particle Habit Imaging and Polar Scattering Probe (PHIPS) classifications, but only weak correlation with High Volume Precipitation Spectrometer (HVPS) classifications. The algorithm was applied to random sets of images from each probe in a case study of a mesoscale snow band sampled on 7 February 2020. In the case study, qualitative analysis of particle images revealed general agreement on classifications among the probes, supporting the algorithm’s applicability to multiple cloud probes. Most classifications appeared correct upon manual inspection, suggesting that in practical use, the algorithm is reasonably able to classify non-idealized images.

Julian Schima↗

Overview of Key Saturn Probe Mission Trades

Ongoing studies, performed at NASA/JPL over the past two years in support of NASA's SSE Roadmap activities, proved the feasibility of a NF class Saturn probe mission. I. This proposed mission could also provide a good opportunity for international collaboration with the proposed Cosmic Vision KRONOS mission: a) With ESA contributed probes (descent modules) on a NASA lead mission; b) Early 2017 launch could be a good programmatic option for ESA-CV/NASA-NF. II. A number of mission architectures could be suitable for this mission: a) Probe Relay based architecture with short flight time (approx. 6.3-7 years); b) DTE probe telecom based architecture with long flight time (-11 years), and low probe data rate, but with the probes decoupled from the carrier, allowing for polar trajectories I orbiter. This option may need technology development for telecom; c) Orbiter would likely impact mission cost over flyby, but would provide significantly higher science return. The Saturn probes mission is expected to be identified in NASA's New Frontiers AO. Thus, further studies are recommended to refine the most suitable architecture. International collaboration is started through the KRONOS proposal work; further collaborated studies will follow once KRONOS is selected in October under ESA's Cosmic Vision Program.

probes↗

X-59 Air Data Probe Calibration Wind Tunnel Test

NASA's aeronautical innovators are working with Lockheed Martin to design and build a supersonic X-plane, the X-59, under the the Low Boom Flight Demonstrator (LBFD) Project, that produces a gentle thump rather than a loud sonic boom. The plane will be used to collect human response data over select U.S. communities. The data from the X-59 test flights will be provided to U.S. and international regulators to potentially allow supersonic flight over land, drastically reducing travel time within the U.S. and around the world. Two wind tunnel tests were conducted in the NASA Glenn Research Center (GRC) 8- by 6-Foot Supersonic Wind Tunnel to calibrate the nose probe for the X-59. The probe was successfully tested and calibrated at 19 Mach numbers between Mach 0.25 and Mach 1.7. Most data were collected using continuous roll angle sweeps at a set Mach number and pitch angle. About 725 high quality data runs were recorded during testing to be used in the calibration of the probe. A backup nose probe was also run through the same test matrix as the primary probe. The probe will be the primary instrument for the flight test of the X-59 for determining angle of attack, angle of sideslip, airspeed, and pressure altitude of the aircraft in flight. Knowing the aircraft's speed and attitude is critical for flight safety and is also critical data for the Sonic Boom mission. Areas of interest for the test were sea level takeoff and landing at Mach 0.2, subsonic cruise at Mach 0.9, and supersonic cruise at Mach 1.4. During Phase I flight testing, the air data nose probe and air data system as a whole will be further calibrated in flight to account for additional installed effects of the airframe on the air data system.

X-59↗

X-59 Air Data Probe Calibration Wind Tunnel Test

NASA's aeronautical innovators are working with Lockheed Martin to design and build a supersonic X-plane, the X-59, under the the Low Boom Flight Demonstrator (LBFD) Project, that produces a gentle thump rather than a loud sonic boom. The plane will be used to collect human response data over select U.S. communities. The data from the X-59 test flights will be provided to U.S. and international regulators to potentially allow supersonic flight over land, drastically reducing travel time within the U.S. and around the world. Two wind tunnel tests were conducted in the NASA Glenn Research Center (GRC) 8- by 6-Foot Supersonic Wind Tunnel to calibrate the nose probe for the X-59. The probe was successfully tested and calibrated at 19 Mach numbers between Mach 0.25 and Mach 1.7. Most data were collected using continuous roll angle sweeps at a set Mach number and pitch angle. About 725 high quality data runs were recorded during testing to be used in the calibration of the probe. A backup nose probe was also run through the same test matrix as the primary probe. The probe will be the primary instrument for the flight test of the X-59 for determining angle of attack, angle of sideslip, airspeed, and pressure altitude of the aircraft in flight. Knowing the aircraft's speed and attitude is critical for flight safety and is also critical data for the Sonic Boom mission. Areas of interest for the test were sea level takeoff and landing at Mach 0.2, subsonic cruise at Mach 0.9, and supersonic cruise at Mach 1.4. During Phase I flight testing, the air data nose probe and air data system as a whole will be further calibrated in flight to account for additional installed effects of the airframe on the air data system.

X-59↗

Measurement Accuracy and Uncertainty Analysis of the X-59 Air Data Probe Calibration Test Entry One

The X-59 is being developed to demonstrate quiet sonic boom technology. Data was obtained via two test entries in the NASA Glenn Research Center’s 8- by 6-Foot Supersonic Wind Tunnel to calibrate the X-59’s nose air data probe. The first entry tested two theoretically identical probes with the intention of one of the probes becoming the primary X-59 nose air data probe flight hardware and the other becoming a backup. A measurement accuracy and uncertainty analysis was performed on data obtained from the first test entry. The analysis showed that the uncertainties in the probe pressures were nearly identical for the two probes, with an average difference of 2.51 x 10-5 for the non-dimensional total pressure and 2.88 x 10-5 for the non-dimensional static pressures. The analysis also showed that the uncertainty in the probe yaw and pitch angles were 0.00034° and 0.01416°, respectively. This gives confidence in the X-59’s flight air data system.

Air Data Probe↗

Measurement Accuracy and Uncertainty Analysis of the X-59 Air Data Probe Calibration Test Entry One

The X-59 is being developed to demonstrate quiet sonic boom technology. Data was obtained via two test entries in the NASA Glenn Research Center’s 8- by 6-Foot Supersonic Wind Tunnel to calibrate the X-59’s nose air data probe. The first entry tested two theoretically identical probes with the intention of one of the probes becoming the primary X-59 nose air data probe flight hardware and the other becoming a backup. A measurement accuracy and uncertainty analysis was performed on data obtained from the first test entry. The analysis showed that the uncertainties in the probe pressures were nearly identical for the two probes, with an average difference of 2.51 x 10 -5 for the non-dimensional total pressure and 2.88 x 10 -5 for the non-dimensional static pressures. The analysis also showed that the uncertainty in the probe yaw and pitch angles were 0.00034° and 0.01416°, respectively. This gives confidence in the X-59’s flight air data system.

Air Data Probe↗

Wind Tunnel Test of A Scale Model of A Venus Probe to Determine Aeroacoustics Environment

The Zephyr probe for NASA’s DAVINCI project is being designed to fly to Venus and collect measurements to characterize the Venusian atmosphere while it descends towards the surface. Despite a slow descent speed as the probe approaches the surface, the very dense atmosphere means the vibro-acoustic environment that the probe must withstand could be very harsh. A wind tunnel test campaign was conducted to characterize the surface-pressure fluctuations (acoustics) on the external surface of the probe during the descent. The goal was to provide forcing functions for vibro-acoustic analysis of all instruments inside the probe. A 25% scale-model of the Zephyr probe was manufactured, instrumented with 18 microphones, and tested in two wind tunnels located in the Fluid Mechanics Lab at NASA Ames Research Center at velocities ranging from 13 m/s to 48 m/s. Trip strips were added to the model to ensure a turbulent boundary layer on the model. Microphones were located appropriately to provide spectra of pressure fluctuations in regions with different flow characteristics as well as for calculating various two-point statistics. The acoustic spectra measured in the wind tunnel tests were scaled up to flight-scale using the estimated flight trajectory information. Besides fluctuating surface-pressure measurements, hot-film velocity measurements as well as smoke-laser flow visualization were conducted to better understand the flow around the probe. Lastly, several different geometry configurations were tested to see whether any reduction in acoustic levels could be achieved, but none of the configurations that were tested offered significant improvements. The flow visualization showed 3 primary flow regimes on the model: an attached turbulent boundary layer on the front of the model, a region of separated flow upstream of the flared lip, and a large, separated wake at the rear of the model. The acoustic spectra generally show three different shapes corresponding to these flow regions, with the highest levels seen at the rear of the model, and directly in front of the drag plate. The scaled overall levels of pressure fluctuations were found to be high: in the range of 130dB to 155dB.

planetary probe↗

Outer planet entry probe system study. Volume 1: Summary

General mission considerations and science prospectus, which are of a general nature that applies to several or all planetary applications, are presented. Five probe systems are defined: nominal Jupiter probe system, and Jupiter probe-dedicated alternative probe system, Jupiter spacecraft radiation-compatible alternative probe system, Saturn probe system, and Saturn probe applicability for Uranus. Parametric analysis is summarized for mission analysis of a general nature, and then for specific missions to Jupiter, Saturn, Uranus, and Neptune. The program is also discussed from the hardware availability viewpoint and the aspect of commonality.

Source record↗

Properties of the wake of small Langmuir probes on sounding rockets

Split Langmuir probes have been used to study the near wake of small Langmuir probes on sounding rockets. Experiments have been performed on two rocket flights using planar disk and cylindrical geometries, and the results are presented. Significant wake perturbations in plasma density and temperature were found due to the probe body itself, even though the probes were of the order of or smaller than the Debye length. The largest effects of the wake are seen in the electron collection characteristics of the probe. The wake of small probes show apparent magnetic field aligned structure, even though the probes were much smaller than the ion gyroradius. On one flight, a space charge potential large enough to substantially alter photoemission, -3.5 volts, was observed.

Bering, E. A.↗

Probe corrected far-field reconstruction from measurements on a cylinder: A novel formulation and efficient algorithm

A novel and numerically efficient method of far field evaluation from measurements taken on a cylinder is based on the representation of both the antenna and the probe fields as superpositions of plane waves. A system of two integral equations are established whose unknown functions are the azimuthal and elevation components of the antenna pattern and whose known terms are the set of measurement data taken with two different probes - the second probe in most practical instances being simply the same probe with a different geometrical orientation. The equations express the known data - for each angular position of the antenna under measurement - as the integrals of the products of the corresponding components of the unknown antenna and known probe patterns multiplied by a phase term. The convolutional nature of the integral equations makes their solutions straight-forward. If, as is virtually always the case, the probe is small or of moderate size so that the axis of rotation of the antenna mount is in the far field of the probe, the intervention of asymptotic techniques makes the solution numerically very efficient. The agreement of calculated and experimental patterns is excellent.

Borgiotti, G. V.↗

The infinite line pressure probe

The infinite line pressure probe provides a means for measuring high frequency fluctuating pressures in difficult environments. A properly designed infinite line probe does not resonate; thus its frequency response is not limited by acoustic resonance in the probe tubing, as in conventional probes. The characteristics of infinite line pressure probes are reviewed and some applications in turbine engine research are described. A probe with a flat-oval cross section, permitting a constant-impedance pressure transducer installation, is described. Techniques for predicting the frequency response of probes with both circular and flat-oval cross sections are also cited.

Englund, D. R.↗

Ram-wake effects on plasma current collection of the PIX 2 Langmuir probe

The Plasma Interaction Experiment 2 (PIX 2) Langmuir probe readings of the same polar magnetospheric regions taken on consecutive orbits showed occasional apparent densities as much as 10 times lower than the average, although each pass clearly showed density structures related to the day/night boundary. At other points in the orbit, Langmuir probe currents varied by as much as a factor of 20 on a time scale of minutes. The hypothesis is advanced that these apparent inconsistencies in Langmuir probe current are the results of the probe's orientation relative to the body of the spacecraft and the velocity vector. Theoretical studies predict a possible depletion in collected electron current by a factor of 100 in the wake. Experimental results from other spacecraft indicate that a wake electron depletion by a factor of 10 or so is realistic. This amount of depletion is consistent with the PIX 2 data if the spacecraft was rotating. Both the Sun sensor and temperature sensor data on PIX 2 show a complex variation consistent with rotation of the Langmuir probe into and out of the spacecraft wake on a time scale of minutes. Furthermore, Langmuir probe data taken when the probe was not in the spacecraft wake are consistent from orbit to orbit. This supports the interpretation that ram/wake effects may be the source of apparent discrepancies at other orientations.

Ferguson, D. C.↗

The infinite line pressure probe

The infinite line pressure probe provides a means for measuring high frequency fluctuating pressures in difficult environments. A properly designed infinite line probe does not resonate; thus its frequency response is not limited by acoustic resonance in the probe tubing, as in conventional probes. The characteristics of infinite line pressure probes are reviewed and some applications in turbine engine research are described. A probe with a flat-oval cross section, permitting a constant-impedance pressure transducer installation, is described. Techniques for predicting the frequency response of probes with both circular and flat-oval cross sections are also cited.

Englund, D. R.↗

Measurement of a zonal wind profile on Titan by Doppler tracking of the Cassini entry probe

A program, called the Cassini mission, intended to study the Saturn system by utilizing a Saturn orbiter and a probe descending to the surface of Titan, is discussed. Winds are expected to cause perturbations to the probe local horizontal velocity, resulting in an anomalous drift in the probe location and a shift in the frequency of the probe telemetry, due to the Doppler effect. By using an iterative algorithm, in which the time variation of the probe telemetry frequency is monitored throughout the descent, and the probe trajectory is updated to reflect the effect of wind on the probe location, a highly accurate relative wind profile can be recovered. By adding a single wind velocity, measured by independent means, an absolute wind profile can be obtained. However, the accuracy of the zonal winds recovery is limited by errors in trajectory, and frequency.

Atkinson, D. H.↗

Titan aerosol and gas experiment for the Huygens Probe

The Cassini Mission is a joint undertaking of NASA and the European Space Agency (ESA) to explore the Saturnian System with a Saturn Orbiter and a Titan Probe. The launch vehicle and the Saturn Orbiter are the responsibility of NASA while the Huygens Probe (detachable Titan Probe) is the responsibility of ESA. The spacecraft will be launched in 1996 and the Huygens Probe will arrive at Titan in 2003. The Cassini Mission-Huygens Probe provides a unique opportunity to obtain detailed information about the atmosphere and, possibly, the surface of Titan. Titan possesses a substantial nitrogen atmosphere containing methane and many other organic compounds. Aerosols play an important role in the atmospheric processes on Titan. The Huygens Probe offers an opportunity to determine how organic particles are formed and grow which will clarify their role on Earth. A powerful analytical instrument, capable of addressing the above technology and other science questions, was recently proposed for the Huygens Probe. It is comprised of an aerosol and gas sampler and processor, and a gas chromatograph-ion mobility spectrometer. The instrument will be able to measure complex organics that make up the collected aerosols to the approximate 1 ppm level. Gases will be measured to approximately 10 ppb. Because the Titan atmosphere is expected to be quite complex, a gas chromatograph-ion mobility spectrometer is used to provide unequivocal identification of the components of the analytes. Further details of the science question to be investigated and the proposed instrument are described. The expected results and their implications are also addressed.

Carle, G. C.↗

A new algorithm for five-hole probe calibration, data reduction, and uncertainty analysis

A new algorithm for five-hole probe calibration and data reduction using a non-nulling method is developed. The significant features of the algorithm are: (1) two components of the unit vector in the flow direction replace pitch and yaw angles as flow direction variables; and (2) symmetry rules are developed that greatly simplify Taylor's series representations of the calibration data. In data reduction, four pressure coefficients allow total pressure, static pressure, and flow direction to be calculated directly. The new algorithm's simplicity permits an analytical treatment of the propagation of uncertainty in five-hole probe measurement. The objectives of the uncertainty analysis are to quantify uncertainty of five-hole results (e.g., total pressure, static pressure, and flow direction) and determine the dependence of the result uncertainty on the uncertainty of all underlying experimental and calibration measurands. This study outlines a general procedure that other researchers may use to determine five-hole probe result uncertainty and provides guidance to improve measurement technique. The new algorithm is applied to calibrate and reduce data from a rake of five-hole probes. Here, ten individual probes are mounted on a single probe shaft and used simultaneously. Use of this probe is made practical by the simplicity afforded by this algorithm.

Reichert, Bruce A.↗

Dual Active Surface Heat Flux Gage Probe

A unique plug-type heat flux gage probe was tested in the NASA Ames Research Center 2x9 turbulent flow duct facility. The probe was fabricated by welding a miniature dual active surface heat flux gage body to the end of a hollow metal cylindrical bolt containing a metal inner tube. Cooling air flows through the inner tube, impinges onto the back of the gage body and then flows out through the annulus formed between the inner tube and the hollow bolt wall. Heat flux was generated in the duct facility with a Huels arc heater. The duct had a rectangular cross section and one wall was fabricated from 2.54 centimeter thick thermal insulation rigid surface material mounted onto an aluminum plate. To measure heat flux, the probe was inserted through the plate and insulating materials with the from of the gage located flush with the hot gas-side insulation surface. Absorbed heat fluxes measured with the probe were compared with absorbed heat fluxes measured with six water-cooled reference calorimeters. These calorimeters were located in a water-cooled metal duct wall which was located across from the probe position. Correspondence of transient and steady heat fluxes measured with the reference calorimeters and heat flux gage probe was generally within a satisfactory plus or minus 10 percent. This good correspondence was achieved even though the much cooler probe caused a large surface temperature disruption of 1000K between the metal gage and the insulation. However, this temperature disruption did not seriously effect the accuracy of the heat flux measurement. A current application for dual active surface heat flux gages is for transient and steady absorbed heat flux, surface temperature and heat transfer coefficient measurements on the surface of an oxidizer turbine inlet deflector operating in a space shuttle test bed engine.