Search NASA⌕ Search

SEARCH · Search NASA

Results for “Protection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

A Review on Protection Challenges on Transmission Lines Connected to Inverter Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses. Utilities, university researchers, research institutes, and relay manufacturers have performed studies to investigate different aspects of high IBR penetration. Almost all studies support 1) creating international and national standards to regulate the IBRs, 2) revising engineering tools to address shortcomings, and 3) adjusting the protective relay settings to resolve protection problems. This paper summarizes the studies and research conducted in recent years to quantify the impact of IBR penetration on transmission line protection and to identify potential solutions to improve the dependability and reliability of grid protection systems.

14 SOLAR ENERGY↗

Verification of Adaptive Protection in Hardware in the Loop for Coordination with Solar Variability

As inverter-based resources continue to be installed at all levels of the electric grid, the fixed protection schemes used at the distribution level will continue to be stressed until they no longer ensure the protection of the grid. Adaptive protection has been proposed as a solution with the ability to update the protection schemes in near real-time to ensure reliability and increase the resilience of the grid. However, weather variability poses a significant challenge to the ability of these methods to keep the selectivity and reliability of these schemes coordinated. If the ramp rates, due to solar variability, of the inverter-based resources change faster than the adaptive protection can issue new settings, the protection system could be uncoordinated, with the wrong device responding to a system fault. The proposed adaptive protection method ensures that due to solar variability, communication, and protection calculation latency, it can issu e coordinated protection settings promptly, in one minute or less. The hardware-in-the-loop results show the protection settings being issued and maintaining system coordination in under a minute.

Summers, Adam↗

Audit Report, "Fire Protection Deficiencies at Los Alamos National Laboratory"

The Department of Energy's Los Alamos National Laboratory (Los Alamos) maintains some of the Nation's most important national security assets, including nuclear materials. Many of Los Alamos' facilities are located in close proximity to one another, are occupied by large numbers of contract and Federal employees, and support activities ranging from nuclear weapons design to science-related activities. Safeguarding against fires, regardless of origin, is essential to protecting employees, surrounding communities, and national security assets. On June 1, 2006, Los Alamos National Security, LLC (LANS), became the managing and operating contractor for Los Alamos, under contract with the Department's National Nuclear Security Administration (NNSA). In preparation for assuming its management responsibilities at Los Alamos, LANS conducted walk-downs of the Laboratory's facilities to identify pre-existing deficiencies that could give rise to liability, obligation, loss or damage. The walk-downs, which identified 812 pre-existing fire protection deficiencies, were conducted by subject matter professionals, including fire protection experts. While the Los Alamos Site Office has overall responsibility for the effectiveness of the fire protection program, LANS, as the Laboratory's operating contractor, has a major, day-to-day role in minimizing fire-related risks. The issue of fire protection at Los Alamos is more than theoretical. In May 2000, the 'Cerro Grande' fire burned about 43,000 acres, including 7,700 acres of Laboratory property. Due to the risk posed by fire to the Laboratory's facilities, workforce, and surrounding communities, we initiated this audit to determine whether pre-existing fire protection deficiencies had been addressed. Our review disclosed that LANS had not resolved many of the fire protection deficiencies that had been identified in early 2006: (1) Of the 296 pre-existing deficiencies we selected for audit, 174 (59 percent) had not been corrected; and, (2) A substantial portion of the uncorrected deficiencies, 86 (49 percent) were considered by the walk-down teams to be significant enough to warrant compensatory actions until the deficiency was corrected or was tracked to closure through implementation of corrective actions. Further, we found that 32 of the significant deficiencies had been closed by the previous Los Alamos contractor, prior to LANS assuming responsibility for operation of the Laboratory, even though the deficiencies had not been corrected. A fire protection expert provided technical support during the audit. As an example of uncorrected problems, LANS had not resolved, by performing periodic tests, a deficiency identified in 2006 regarding a kitchen hood fire suppression system in a facility located within the Los Alamos Neutron Science Center. Such systems are required to be tested twice a year by the National Fire Protection Association standard, a standard that had been adopted by Department of Energy under DOE Order 420.1B. Yet, in 2006, the LANS walk-down team recognized that this system had not been inspected since May 2004 and noted that deficient suppression systems could result in significantly high levels of property damage and loss. After we brought this issue to management's attention on February 6, 2009, LANS officials stated that the Laboratory would correct this deficiency. As with the problems involving the fire suppression system, we observed that LANS had not always corrected life safety deficiencies involving building exits at one of its primary facilities. This included providing a secondary emergency exit for a building with occupants on multiple floor levels. LANS had removed personnel from the third floor and improved the sprinkler system of the facility, but it had still not provided a secondary exit for personnel on the second floor by the time we completed our review. NNSA has since stated that this fire protection issue will be completely addressed by relocating personnel from the second floor. Perhaps most serious, our testing revealed that a number of deficiencies were formally closed even though actual corrective action had not been completed. Notably, we observed that action had not been taken to resolve a recommendation to replace a fire alarm panel found to be unreliable. After the walk-down was conducted but prior to contract transition, the former contractor closed the recommendation in its action tracking database even though the panel had not been replaced. The walk-down team had categorized the fire alarm system as requiring replacement since it had been modified many times, was old and obsolete, and had very limited available spare parts. In fact, the walk-down team concluded that the panel 'must be considered to be unreliable and should have a very high priority for replacement'.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Utility Perspective on Protection Challenges with High Penetration of IBRs

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report / presentation identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, this report looks broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the report summarizes on gathered data and internal experiences.

14 SOLAR ENERGY↗

Protection against acetaminophen-induced liver injury by allopurinol is dependent on aldehyde oxidase-mediated liver preconditioning

Acetaminophen (APAP) overdose causes severe and occasionally fatal liver injury. Numerous drugs that attenuate APAP toxicity have been described. However these compounds frequently protect by cytochrome P450 inhibition, thereby preventing the initiating step of toxicity. We have previously shown that pretreatment with allopurinol can effectively protect against APAP toxicity, but the mechanism remains unclear. In the current study, C3HeB/FeJ mice were administered allopurinol 18 h or 1 h prior to an APAP overdose. Administration of allopurinol 18 h prior to APAP overdose resulted in an 88% reduction in liver injury (serum ALT) 6 h after APAP; however, 1 h pretreatment offered no protection. APAP-cysteine adducts and glutathione depletion kinetics were similar with or without allopurinol pretreatment. The phosphorylation and mitochondrial translocation of c-jun-N-terminal-kinase (JNK) have been implicated in the progression of APAP toxicity. In our study we showed equivalent early JNK activation (2 h) however late JNK activation (6 h) was attenuated in allopurinol treated mice, which suggests that later JNK activation is more critical for the toxicity. Additional mice were administered oxypurinol (primary metabolite of allopurinol) 18 h or 1 h pre-APAP, but neither treatment protected. This finding implicated an aldehyde oxidase (AO)-mediated metabolism of allopurinol, so mice were treated with hydralazine to inhibit AO prior to allopurinol/APAP administration, which eliminated the protective effects of allopurinol. We evaluated potential targets of AO-mediated preconditioning and found increased hepatic metallothionein 18 h post-allopurinol. These data show metabolism of allopurinol occurring independent of P450 isoenzymes preconditions the liver and renders the animal less susceptible to an APAP overdose. - Highlights: • 18 h allopurinol pretreatment protects against acetaminophen-induced liver injury. • 1 h allopurinol pretreatment does not protect from APAP-induced injury. • 18 h or 1 h oxypurinol pretreatment does not alter APAP-induced injury. • Inhibiting aldehyde oxidase eliminates protection from 18 h allopurinol pretreatment. • 18 h allopurinol induces metallothionein which protects the liver against APAP injury.

60 APPLIED LIFE SCIENCES↗

Policy-relevant differences between secondhand and thirdhand smoke: strengthening protections from involuntary exposure to tobacco smoke pollutants

Starting in the 1970s, individuals, businesses and the public have increasingly benefited from policies prohibiting smoking indoors, saving thousands of lives and billions of dollars in healthcare expenditures. Smokefree policies to protect against secondhand smoke exposure, however, do not fully protect the public from the persistent and toxic chemical residues from tobacco smoke (also known as thirdhand smoke) that linger in indoor environments for years after smoking stops. Nor do these policies address the economic costs that individuals, businesses and the public bear in their attempts to remediate this toxic residue. We discuss policy-relevant differences between secondhand smoke and thirdhand smoke exposure: persistent pollutant reservoirs, pollutant transport, routes of exposure, the time gap between initial cause and effect, and remediation and disposal. We examine four policy considerations to better protect the public from involuntary exposure to tobacco smoke pollutants from all sources. We call for (a) redefining smokefree as free of tobacco smoke pollutants from secondhandandthirdhand smoke; (b) eliminating exemptions to comprehensive smoking bans; (c) identifying indoor environments with significant thirdhand smoke reservoirs; and (d) remediating thirdhand smoke. We use the case of California as an example of how secondhand smoke-protective laws may be strengthened to encompass thirdhand smoke protections. The health risks and economic costs of thirdhand smoke require that smokefree policies, environmental protections, real estate and rental disclosure policies, tenant protections, and consumer protection laws be strengthened to ensure that the public is fully protected from and informed about the risks of thirdhand smoke exposure.

Public, Environmental & Occupational Health↗

Modeling protected species distributions and habitats to inform siting and management of pioneering ocean industries: A case study for Gulf of Mexico aquaculture

Marine Spatial Planning (MSP) provides a process that uses spatial data and models to evaluate environmental, social, economic, cultural, and management trade-offs when siting (i.e., strategically locating) ocean industries. Aquaculture is the fastest-growing food sector in the world. The United States (U.S.) has substantial opportunity for offshore aquaculture development given the size of its exclusive economic zone, habitat diversity, and variety of candidate species for cultivation. However, promising aquaculture areas overlap many protected species habitats. Aquaculture siting surveys, construction, operations, and decommissioning can alter protected species habitat and behavior. Additionally, aquaculture-associated vessel activity, underwater noise, and physical interactions between protected species and farms can increase the risk of injury and mortality. In 2020, the U.S. Gulf of Mexico was identified as one of the first regions to be evaluated for offshore aquaculture opportunities as directed by a Presidential Executive Order. We developed a transparent and repeatable method to identify aquaculture opportunity areas (AOAs) with the least conflict with protected species. First, we developed a generalized scoring approach for protected species that captures their vulnerability to adverse effects from anthropogenic activities using conservation status and demographic information. Next, we applied this approach to data layers for eight species listed under the Endangered Species Act, including five species of sea turtles, Rice’s whale, smalltooth sawfish, and giant manta ray. Next, we evaluated four methods for mathematically combining scores (i.e., Arithmetic mean, Geometric mean, Product, Lowest Scoring layer) to generate a combined protected species data layer. The Product approach provided the most logical ordering of, and the greatest contrast in, site suitability scores. Finally, we integrated the combined protected species data layer into a multi-criteria decision-making modeling framework for MSP. This process identified AOAs with reduced potential for protected species conflict. These modeling methods are transferable to other regions, to other sensitive or protected species, and for spatial planning for other ocean-uses.

54 ENVIRONMENTAL SCIENCES↗

Cybersecurity for Distance Relay Protection

This project is a DOE follow-up effort on the CREDC workshop held on September 13, 2018 in Cambridge, MA to discuss cybersecurity of distance relays, which considered the benefits, vulnerabilities and risk mitigations for the use of communication systems in power system protection. The objectives of this project are to define the taxonomy of relay protection and associated communications; define use cases describing approaches to reduce the cyber-attack surface on those protective relays; and evaluate the loss of operational functional capability from changes to communication coverage. Mitigating controls will also be evaluated to understand if there are other approaches to reduce attack surfaces while maintaining communications or partial communications. Distance relays are used to protect transmission lines of approximately 10 to 300 miles in length, by detecting short circuits (i.e., faults) on the lines and then tripping circuit breakers in the substation. Such protection systems are a subset of the power system and they incorporate sensing, logic and communication functions. Protection system exposure to cyberattack could be drastically limited by disconnecting relays from all vulnerable communication systems, but this may adversely impact overall power system performance in the absence of cyberattack. This project began with a use case analysis of protection systems with communications, as summarized in this report. It continued with modeling, testing and evaluation in a miniature power system (MPS), located in the Western Area Power Administration (WAPA) Electric Power Training Center (EPTC). The project also incorporated feedback from two industry meetings held in February and September 2019. The suggested next steps account for and complement the work already underway with DOE/CESER funding: 1. Study the performance of LCD and PC vs. PUTT, which is less reliant on communication system performance and GPS timing references. The PUTT scheme could prove to be more resilient to cyberattack or communications-related disruption. It could also be more tolerant of message re-routing with SDN/SDR communication systems. On the other hand, it will be more vulnerable to false tripping during dynamic events or to loss of the voltage signal. The optimum choice of scheme may depend on the specific power system and risk assessment. This study could provide a new template for evaluation based on business functions. 2. Research and develop new methods to detect and monitor distributed physical attacks, possibly using drones, video sensors, thermal sensors, machine learning and other advanced techniques. This will help mitigate the impact of cyberattack on the protection system, and will also help mitigate the impact of wild fires. 3. Implement a scalable PKI for use in electric utility protection systems. This will encourage widespread adoption of secure authentication methods that are already available, but not widely used at present. This will help secure engineering access to the relays. 4. Investigate the use of SDN in combination with SDR to achieve better cybersecurity and electromagnetic security of the network, incorporating path variability. This would help secure both engineering access and peer-to-peer GOOSE messaging. 5. Perform additional testing, with operator evaluation of “red button” scenarios, PUTT vs. LCD, relay mis-operations, and other cyberattacks in the EPTC. This is an important advantage of testing in the EPTC rather than by computer simulation or even hardware-in-the-loop simulation; the EPTC is already dedicated to managing the situational awareness, operator response times and other human impacts. One of the project objectives was to settle on a common nomenclature for this problem space. We have concluded that the OSI layer model, supplemented by ANSI device numbers and other IEEE standards, is already well-accepted by the industry. The IEEE PSRC knowledge base provides a great deal of public information

24 POWER TRANSMISSION AND DISTRIBUTION↗

POSSIBILITIES FOR ASSESSMENT AND OPTIMIZATION OF NPP PHYSICAL PROTECTION SYSTEMS IN UKRAINE ON THE BASIS OF NUCLEAR SAFETY ANALYSIS

The design requirements for physical protection systems currently adopted at Ukrainian NPPs were established in the middle of the nineties on the basis of deterministic analyses and expert evaluations of the vulnerabilities of reactor facilities. At the present time the in-depth assessment of the nuclear safety of Ukrainian NPPs with VVER-1000/B320 reactors has been completed using Probabilistic Safety Assessment (PSA). PSA has established and provided a qualitative assessment of the significance of the equipment for maintaining the integrity of a reactor core and preventing an abnormal radioactive release. The availability of qualitative assessments of the importance of equipment for nuclear safety allows one to assess the existing physical protection system using (1) comparative analysis: to determine whether all equipment and zones that may be affected, as established by the nuclear safety assessment, are actually included into the vital zones protected by the existing physical protection system; (2) specific analysis of dominant contributors: since nuclear safety analyses provide qualitative assessment of the equipment’s importance for safety, it is easy to select a limited group of essential equipment that makes the major contribution to safety, and (3) specific equipment analysis included in dominant emergency sets: part of the components might not be included in the essential equipment group, but it might be included in the dominant emergency sets. If some equipment is found not to be covered by the physical protection system, it is possible, using qualitative assessment of the importance of this equipment for safety, to assess the required degree of enhancement of physical protection. Such analysis will permit an assessment of the sufficiency of the existing physical protection system, to define the "tight" system areas and, therefore, to develop a justified optimization of a PPS with the objective of implementing priority upgrades to enhance safety, and using limited resources in the most effective way. The application of risk-informed approaches to assessment, and subsequent optimization of the physical protection system will permit establishing basis for the implementation of the so-called graded-protection concept.

Shcherbinin, Konstantin↗

Protective barriers and related methods

Protective barriers for protecting assets (e.g., electrical power transformers and other substation components). The protective barrier may include a lower portion and an upper portion. The lower portion may include first and second laterally spaced A-frame structures having a first protective member assembly extending between aligned legs of the respective A-frame structures on one side thereof. The first protective member assembly may include a first plurality of substantially horizontally extending protective members oriented at an angle relative to a horizontal plane. The first and second A-frame structures may have a second protective member assembly extending between aligned legs of the respective A-frame structures on an opposing side thereof. The upper portion may comprise a third protective member assembly. Methods of making a protective barrier are also disclosed.

42 ENGINEERING↗

Synopsis of the Oak Ridge Radiation Protection Research Needs Workshop

Radiation protection is foundational to harnessing the societal benefits of radiation in nuclear energy, security, and medicine applications. Significant challenges in radiation protection remain unaddressed for the nuclear fuel cycle, nuclear medicine, emergency response, national defense, and space exploration, as the United States is lacking a coherent research strategy prioritizing radiation protection mission needs and gaps in scientific knowledge to meet these needs. Research and development in the field of radiation protection calls for cooperation among governmental agencies, emergency responders, research organizations, and the academic community. Amidst atrophying national expertise in radiation protection, the Radiation Protection Research Needs Workshop was spearheaded by the Oak Ridge Associated Universities, Oak Ridge National Laboratory, and the Health Physics Society. This workshop facilitated critical dialogue among radiation stakeholders in the governmental and scientific communities, including national laboratories, academic institutions, and industry partners. The workshop featured presentations representing 12 federal agencies and breakout sessions involving the identification of scientific drivers by subject matter experts in each of the following areas: new fuel cycles/reactors, dosimetry, medical physics, instrumentation and operations, decontamination and decommissioning, space radiation, national defense, emergency response, environmental modeling, and low-dose effects. The goal of this workshop was to seek stakeholder input toward the development of a national strategic research agenda in the field of radiation protection. Consequently, the Health Physics Society has established a Special Task Force on Health Physics Research Needs, tasked with the prioritization of scientific drivers in radiation protection for the development of a national strategic research agenda.

61 RADIATION PROTECTION AND DOSIMETRY↗

Utilities Perspective on Protection Challenges with High IBR Penetration

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This presentation identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, we are looking broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the presentation summarizes on gathered data and internal experiences.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Protection schemes used in North American microgrids

This study reviewed existing conventional and nonconventional protection schemes for grid-connected and islanded mode operations in North American microgrid projects. The microgrid projects investigated in this study used different types of distributed energy resources (DERs) and integrated hydropower/diesel generators, gas/steam/wind turbines, and photovoltaic systems with energy storage. In this work, conventional protection schemes were defined as those within the IEEE Standard C37.2-2008, whereas nonconventional schemes were those not defined within this standard. The pros and cons of conventional and nonconventional protection schemes were discussed in detail. The overvoltage, undervoltage, and frequency elements were the most common conventional protection schemes applied in microgrid projects in North America. These protection elements were used to detect the islanded conditions and faults that could not be sensed by overcurrent relays because of small fault currents contributed by low-inertia DERs and power-electronic sources. Directional overcurrent elements were used to distinguish between external (grid) and internal (microgrid) faults. Adaptive protection was the most popular nonconventional protection scheme applied to the microgrid projects. In conclusion, different types of DERs and operational modes must be considered in order to address the protection and control challenges of each microgrid and to obtain the best technical and economical solution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Compromise of Personal Protective Clothing from Liquid Exposure

Following critiques of multiple personal contamination events from entries into the Oak Ridge National Laboratory’s Spallation Neutron Source transfer bay, it was considered that the most likely causes for contamination were personal protective clothing doffing errors or that moisture (sweat) allowed contamination to wick through the protective clothing. To pursue this issue, radiological protection staff looked more closely, however, at the specific area of the clothing where contamination was highest; under enhanced lighting and photochromic manipulation, there appeared to have been some type of moisture in the area. Recognizing the possibility that moisture may have allowed for migration of contamination through the clothing, further experiments were undertaken to determine under which conditions this transport might have occurred. The objective for this work was to identify the susceptibility of different types of personal protective clothing to various liquids encountered in the workplace.Method: Several tests were performed to determine if perspiration had enabled migration of contamination, and to identify what other liquids might have affected contamination transport. Two layers of personal protective clothing were subjected to static conditions and dynamic conditions, to include active rubbing of the materials while wet. Food dye added to each of the liquids tested enabled visual indications of liquid breakthrough. Additional tests were conducted to see if solid contamination could be transported through the materials along with the liquids. As a result, it was found that all but one type of non-rubberized personal protective clothing in use at Oak Ridge National Laboratory were permanently compromised to some extent by the solvents used for decontamination. It was determined that most common cleaning agents immediately and permanently destroyed the hydrophobic nature of several of the splash-resistant protective clothing materials, allowing for radioactive contamination to penetrate through the material to the worker. Work around wet surfaces or performing wet decontamination will only be performed in protective clothing known to prevent transport of the wetting agent.

61 RADIATION PROTECTION AND DOSIMETRY↗

On the Adaptive Protection of Microgrids: A Review on How to Mitigate Cyber Attacks and Communication Failures

One main challenge in the practical implementation of a microgrid is the design of an adequate protection scheme in both grid connected and islanded modes. Conventional overcurrent protection schemes face selectivity and sensitivity issues during grid and microgrid faults since the fault current level is different in both cases for the same relay. Various approaches have been implemented in the past to deal with this problem, yet the most promising ones are the implementation of adaptive protection techniques abiding by the IEC 61850 communication standard. This paper presents a critical review of existing adaptive protection schemes, the technical challenges for the use of classical protection techniques and the need for an adaptive, smart protection system. However, the risk of communication link failures and cyber security threats still remain a challenge in implementing a reliable adaptive protection scheme. A contingency is needed where a communication issue prevents the relay from adjusting to a lower current level during islanded mode. An adaptive protection scheme is proposed that utilizes energy storage (ES) and hybrid ES (HESS) already available in the network as a mechanism to source the higher fault current. Four common grid ES and HESS are reviewed for their suitability in feeding the fault while some solutions are proposed.

25 ENERGY STORAGE↗

Real-Time Hardware-in-The-Loop Implementation of Protection and Self-Healing of Microgrids

The design of a reliable protection scheme for microgrids often requires communication between protective devices and microgrid controllers. The authors have developed such a communication assisted scalable protection scheme with a self healing feature to protect a microgrid with 100% Inverter Based Resources (IBRs). The communication assisted scheme must be validated in real time with cyber physical co-simulation for successful demonstration. In this regard, the paper presents a co-simulation platform between a simulated power system model using RTDS and physical protective devices. The primary protection of the scheme is programmed in SEL 421-7 relay and backup protection is programmed in MATLAB on a generic computer acting as a microgrid controller. The IEC 61850 models are used to communicate between SEL-421-7 relay and RTDS, whereas TCP/IP communication connects the microgrid controller to RTDS. The paper’s focus is to demonstrate the co- simulation platform with communication links established using both protocols and validate the proposed scheme in real-time on the IEEE 123 node distribution feeder. The paper explains the configuration of the IEC 61850 and TCP/IP communications as the interface requires proper hardware and software setup. Furthermore, the real time performance indicates the Hardware In the Loop (HIL) framework as a competent testing environment for the developed protection scheme for microgrids.

42 ENGINEERING↗

SU-E-I-76: Matching Primary and Scattered X-Ray Spectra for Use in Calculating the Diagnostic Radiation Index of Protection

Purpose: Lightweight lead-free or lead-composite protective garments exploit k-edge interactions to attenuate scattered X-rays. Manufacturers specify the protective value of garments in terms of lead equivalence at a single kVp. This is inadequate, as the protection provided by such garments varies with radiation quality in different use conditions. We present a method for matching scattered X-ray spectra to primary X-ray spectra. The resulting primary spectra can be used to measure penetration through protective garments, and such measurements can be weighted and summed to determine a Diagnostic Radiation Index for Protection (DRIP). Methods: Scattered X-ray spectra from fluoroscopic procedures were modeled using Monte Carlo techniques in MCNP-X 2.7. Data on imaging geometry, operator position, patient size, and primary beam spectra were gathered from clinical fluoroscopy procedures. These data were used to generate scattered X-ray spectra resulting from procedural conditions. Technical factors, including kV and added filtration, that yielded primary X-ray spectra that optimally matched the generated scattered X-ray spectra were identified through numerical optimization using a sequential quadratic programming (SQP) algorithm. Results: The primary spectra generated with shape functions matched the relative flux in each bin of the scattered spectra within 5%, and half and quarter-value layers matched within 0.1%. The DRIP for protective garments can be determined by measuring the penetration through protective garments using the matched primary spectra, then calculating a weighted average according to the expected clinical use of the garment. The matched primary spectra are specified in terms of first and second half-value layers in aluminum and acrylic. Conclusion: Lead equivalence is inadequate for completely specifying the protective value of garments. Measuring penetration through a garment using full scatter conditions is very difficult. The primary spectra determined in this work allow for practical primary penetration measurements to be made with equipment readily available to clinical medical physicists.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Sensitivity-driven Wide Area Protection (SWAP) Coordination Tool for High Penetration of Inverter-based Resources (IBR)

Traditionally, power system generation sources have been composed of synchronous generators, of which the fault current behavior is understood with minimal differences between generation size and types due to the physics of their construction. Present protection schemes and modeling methods are based upon these understood characteristics. Most renewable generation is composed of inverter-based resources (IBR), in which fault current is determined by switching control software and hardware limitations, each of which can vary between manufacturers and even between models of the same manufacturer. The resulting fault current is low in magnitude, low in negative-sequence current, unpredictable phase angles, and is a challenge to model. These characteristics also result in a challenge to traditional protection schemes and fault simulation software. To address several of these concerns, the project has the following goals: 1. Improve IBR models: Improve IBR models used in short circuit (SC) programs to accurately capture the response of IBRs at the bulk power system (BPS) level for fault and protection studies. 2. Develop automation tool: Develop an automation tool that allows engineers to identify protection coordination and sensitivity issues by performing SC and protection coordination studies in a high IBR-penetrated grid by applying variations to the IBR models, faults, contingencies, etc. 3. Develop schemes: Develop new protection mitigation solution schemes that complement the existing protection systems to ensure safe operation of the BPS with higher IBR penetration levels. The project team did not achieve this final goal, as the Department of Energy (DOE) stopped the project early due to changes in DOE funding priorities. The termination notice came at the beginning of the final project phase, while the team was identifying and beginning to investigate protection issues. It should be noted that the team discussed a 100% penetration scenario. However, this scenario would require the use of grid-forming IBR models that are not presently available. Since developing these models requires additional effort, the 100% penetration scenario was not pursued during this project. In the future, developing the methodology and models for the 100% scenario could benefit the industry.

14 SOLAR ENERGY↗