Search NASA⌕ Search

SEARCH · Search NASA

Results for “Proton imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Advancing Artificial Intelligence with Liquid Argon Neutrino Experiments (Technical Report)

The grant allowed two main contributions: 1) The development of a first successful demonstration of the employment of Optimal Transport in liquid argon time projection chamber neutrino detectors. Optimal Transport, used in other contexts and specifically with LHC calorimetric data, was adapted to address a key particle identification challenge in LArTPCs: the separation of pi0 backgrounds from single-electrons produced in charged-current electron neutrino interactions. The work, leveraging ML methods such as k-nearest-neighbor (kNN) and support-vector-machine (SVM), showed an increase in background rejection of a factor of two or more. Work is now ongoing to incorporate this development in physics analyses for LArTPC experiments and more broadly expand the use of OT in LArTPC detectors including DUNE. This work was done in collaboration with the phenomenology group led by Nathaniel Craig at UCSB. 2) The deployment of NuGraph2, a graph neural network developed for LArTPC reconstruction, in the MicroBooNE experiment. NuGraph2 uses novel graph-neural-network methods on the rather simple LArTPC inputs of reconstructed hits, greatly simplifying the workflow compared to the use of waveform or signal-deconvolved wire ROIs. The network performed particle classification and was shown to address many challenging problems in LArTPC imaging including track-shower separation and the identification of protons and charged pions from primary muons. Our group collaborated with Giuseppe Cerati (FNAL scientist) who is one of the core developers of NuGraph2 to integrate this tool in MicroBooNE’s analysis framework. This consisted in tow key contributions: a) Studying performance on real data, which came with several months of iterations because the MC-trained version of the network was found to show significant bias that our group investigated and addressed. b) Integrating the output hit labeling of NuGraph2 into the existing particle tracking and shower reconstruction code. As a result of this work led by our team NuGraph2 is now enabling a suite of new analyses which benefit from enhanced capabilities and thus broader physics reach. The grant supported primarily the salary of UCSB graduate student Chuyue “Michaelia” Fang as well as partial summer salary support for PI Caratelli. Some funds were used for travel by Michaelia to ML related schools and conferences.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Mars Pathfinder Mission

Mars Pathfinder, one of the first Discovery-class missions (quick, low-cost projects with focused science objectives), will land a single spacecraft with a microrover and several instruments on the surface of Mars in 1997. Pathfinder will be the first mission to use a rover, carrying a chemical analysis instrument, to characterize the rocks and soils in a landing area over hundreds of square meters on Mars, which will provide a calibration point or "ground truth" for orbital remote sensing observations. In addition to the rover, which also performs a number of technology experiments, Pathfinder carries three science instruments: a stereoscopic imager with spectral filters on an extendable mast, an alpha proton X ray spectrometer, and an atmospheric structure instrument/meteorology package. The instruments, the rover technology experiments, and the telemetry system will allow investigations of the surface morphology and geology at submeter to a hundred meters scale, the petrology and geochemistry of rocks and soils, the magnetic properties of dust, soil mechanics and properties, a variety of atmospheric investigations, and the rotational and orbital dynamics of Mars. Landing downstream from the mouth of a giant catastrophic outflow channel, Ares Vallis at 19.5 deg N, 32.8 deg W, offers the potential of identifying and analyzing a wide variety of crustal materials, from the ancient heavily cratered terrain, intermediate-aged ridged plains, and reworked channel deposits, thus allowing first-order scientific investigations of the early differentiation and evolution of the crust, the development of weathering products, and tile early environments and conditions on Mars.

Golombek, Matthew P.↗

Modeling of Proton-Induced CCD Degradation in the Chandra X-Ray Observatory

Modeling results are presented for proton-induced degradation of charge-coupled devices (CCDs) used in the Advanced CCD Imaging Spectrometer instrument on the Chandra X-Ray Observatory. A methodology is described that provides insights regarding degradation mechanism and on-orbit performance for front-illuminated and back-illuminated CCDs Proton-induced changes in charge transfer inefficiency are modeled. The observed amount of on-orbit degradation can be accounted for using a proton spectrum at the CCD location that is reduced in magnitude by a factor of approx. 1E5 compared to the spectrum incident on the spacecraft.

Lo, D. H.↗

Estimation of Length-Scales in Soils by MRI

Soil can be best described as an unconsolidated granular media that forms porous structure. The present macroscopic theory of water transport in porous media rests upon the continuum hypothesis that the physical properties of porous media can be associated with continuous, twice-differentiable field variables whose spatial domain is a set of centroids of Representative Elementary Volume (REV) elements. MRI is an ideal technique to estimate various length-scales in porous media. A 0.267 T permanent magnet at NASA GRC was used for this study. A 2D or 3D spatially-resolved porosity distribution were obtained from the NMR signal strength from each voxel and the spin-lattice relaxation time. A classical spin-warp imaging with Multiple Spin Echos (MSE) was used to evaluate proton density in each voxel. Initial resolution of 256 x 256 was subsequently reduced by averaging neighboring voxels and the porosity convergence was observed. A number of engineered "space candidate" soils such as Isolite(trademark), Zeoponics(trademark), Turface(trademark), and Profile(trademark) were used. Glass beads in the size range between 50 microns to 2 mm were used as well. Initial results with saturated porous samples have shown a good estimate of the average porosity consistent with the gravimetric porosity measurement results. For Profile(trademark) samples with particle sizes ranging between 0.25 to 1 mm and characteristic interparticle pore size of 100 microns the characteristic Darcy scale was estimated to be about delta(sub REV) = 10 mm. Glass beads porosity show clear convergence toward a definite REV which stays constant throughout homogeneous sample. Additional information is included in the original extended abstract.

N E Daidzic↗

Mars Pathfinder Science Investigations and Objectives

Pathfinder's primary ojective is to demonstrate an inexpensive system for curise, entry, descent, and landing on mars. Additional objective include the deployent and operation of various science instruments: a stereoscopic imager with filters on a pop up mast, and alpha proton x-ray spectometer (APXS), and an atmospheric structure instrument/meteorology package

Mars↗

Measurement of the Iron Spectrum in Cosmic Rays from 10 GeV/n to 2.0 TeV/n with the Calorimetric Electron Telescope on the International Space Station

The Calorimetric Electron Telescope (CALET), in operation on the International Space Station since 2015, collected a large sample of cosmic-ray iron over a wide energy interval. In this paper a measurement of the iron spectrum is presented in the range of kinetic energy per nucleon from 10GeV/n to 2.0 TeV/n allowing the inclusion of iron in the list of elements studied with unprecedented precision by space-borne instruments. The measurement is based on observations carried out from January 2016 to May 2020. The CALET instrument can identify individual nuclear species via a measurement of their electric charge with a dynamic range extending far beyond iron (up to atomic number Z = 40). The energy is measured by a homogeneous calorimeter with a total equivalent thickness of 1.2 proton interaction lengths preceded by a thin (3 radiation lengths) imaging section providing tracking and energy sampling. The analysis of the data and the detailed assessment of systematic uncertainties are described and results are compared with the findings of previous experiments. The observed differential spectrum is consistent within the errors with previous experiments. In the region from 50 GeV/n to 2 TeV/ n our present data are compatible with a single power law with spectral index−2.60±0.03.

O Adriani↗

Precision Measurement of the Nickel Spectrum in Cosmic Rays from 8.8 GeV/n to 240 GeV/n with CALET on the International Space Station

The relative abundance of nickel with respect to iron is by far larger than all other trans-iron elements, therefore it provides a favourable opportunity for a low background measurement of its spectrum. Since nickel, as well as iron, is one of the most stable nuclei, the nickel energy spectrum and its relative abundance with respect to iron provide important information to estimate the abundances at the source and to model the propagation of heavy nuclei. However, only a few direct measurements of cosmic-ray nickel at energy larger than∼3 GeV/n are available at present in the literature and they are affected by strong limitations in both energy reach and statistics. In this paper we present a measurement of the differential energy spectrum of nickel from 8.8 GeV/nto 240 GeV/n, carried out with unprecedented precision by the Calorimetric Electron1 Telescope(CALET) in operation on the International Space Station since 2015. The CALET instrument can identify individual nuclear species via a measurement of their electric charge with a dynamic range extending far beyond iron (up to atomic number Z = 40). The particle’s energy is measured by a homogeneous calorimeter (1.2 proton interaction lengths, 27 radiation lengths) preceded by a thin imaging section (3 radiation lengths) providing tracking and energy sampling. This paper follows our previous measurement of the iron spectrum [1] and it extends our investigation on the energy dependence of the spectral index of heavy elements. It reports the analysis of nickel data collected from November 2015 to May 2021 and a detailed assessment of the systematic uncertainties. In the region from 20 GeV/nto 240 GeV/n our present data are compatible within the errors with a single power law with spectral index−2.51±0.07.

O Adriani↗

Hybrid-Vlasov Simulation of Soft X-Ray Emissions at the Earth’S Dayside Magnetospheric Boundaries

Solar wind charge exchange produces emissions in the soft X-ray energy range which can enable the study of near-Earth space regions such as the magnetopause, the magnetosheath and the polar cusps by remote sensing techniques. The Solar wind–Magnetosphere–Ionosphere Link Explorer (SMILE) and Lunar Environment heliospheric X-ray Imager (LEXI) missions aim to obtain soft X-ray images of near-Earth space thanks to their Soft X-ray Imager (SXI) instruments. While earlier modeling works have already simulated soft X-ray images as might be obtained by SMILE SXI during its mission, the numerical models used so far are all based on the magnetohydrodynamics description of the space plasma. To investigate the possible signatures of ion-kinetic-scale processes in soft X-ray images, we use for the first time a global hybrid-Vlasov simulation of the geospace from the Vlasiator model. The simulation is driven by fast and tenuous solar wind conditions and purely southward interplanetary magnetic field. We first produce global X-ray images of the dayside near-Earth space by placing a virtual imaging satellite at two different locations, providing meridional and equatorial views. We then analyze regional features present in the images and show that they correspond to signatures in soft X-ray emissions of mirror mode wave structures in the magnetosheath and flux transfer events (FTEs) at the magnetopause. Our results suggest that, although the time scales associated with the motion of those transient phenomena will likely be significantly smaller than the integration time of the SMILE and LEXI imagers, mirror-mode structures and FTEs can cumulatively produce detectable signatures in the soft X-ray images. For instance, a local increase by 30% in the proton density at the dayside magnetopause resulting from the transit of multiple FTEs leads to a 12% enhancement in the line-of-sight- and time integrated soft X-ray emissivity originating from this region. Likewise, a proton density increase by 14% in the magnetosheath associated with mirror-mode structures can result in an enhancement in the soft X-ray signal by 4%. These are likely conservative estimates, given that the solar wind conditions used in the Vlasiator run can be expected to generate weaker soft X-ray emissions than the more common denser solar wind. These results will contribute to the preparatory work for the SMILE and LEXI missions by providing the community with quantitative estimates of the effects of small-scale, transient phenomena occurring on the dayside.

magnetosphere↗

Ultrafast time-resolved 2D imaging of laser-driven fast electron transport in solid density matter using an x-ray free electron laser

High-power, short-pulse laser-driven fast electrons can rapidly heat and ionize a high-density target before it hydrodynamically expands. The transport of such electrons within a solid target has been studied using two-dimensional (2D) imaging of electron-induced Kα radiation. However, it is currently limited to no or picosecond scale temporal resolutions. Here, we demonstrate femtosecond time-resolved 2D imaging of fast electron transport in a solid copper foil using the SACLA x-ray free electron laser (XFEL). An unfocused collimated x-ray beam produced transmission images with sub-micron and ~10 fs resolutions. The XFEL beam, tuned to its photon energy slightly above the Cu K-edge, enabled 2D imaging of transmission changes induced by electron isochoric heating. Time-resolved measurements obtained by varying the time delay between the x-ray probe and the optical laser show that the signature of the electron-heated region expands at ~25% of the speed of light in a picosecond duration. Time-integrated Cu Kα images support the electron energy and propagation distance observed with the transmission imaging. The x-ray near-edge transmission imaging with a tunable XFEL beam could be broadly applicable for imaging isochorically heated targets by laser-driven relativistic electrons, energetic protons, or an intense x-ray beam.

47 OTHER INSTRUMENTATION↗

MESUR Pathfinder Science Investigations

The MESUR (Mars Environmental Survey) Pathfinder mission is the first Discovery mission planned for launch in 1996. MESUR Pathfinder is designed as an engineering demonstration of the entry, descent and landing approach to be employed by the follow-on MESUR Network mission, which will land of order 10 small stations on the surface of Mars to investigate interior, atmospheric and surface properties. Pathfinder is a small Mars lander, equipped with a microrover to deploy instruments and explore the local landing site. Instruments selected for Pathfinder include a surface imager on a 1 m pop-up mast (stereo with spectral filters), an atmospheric structure instrument/surface meteorology package, and an alpha proton x-ray spectrometer. The microrover will carry the alpha proton x-ray spectrometer to a number of different rocks and surface materials and provide close-up imaging...

Golombek, M.↗

Beam test performance of AstroPix sensor with 120 GeV protons

AstroPix is a High-Voltage CMOS Monolithic Active Pixel Sensor (HV-CMOS MAPS) developed for precision gamma-ray imaging and spectroscopy in the medium-energy regime, as well as for precise shower imaging and tracking in the Barrel Imaging Calorimeter (BIC) of the Electron Proton/Ion Collider (ePIC) detector at the future Electron–Ion Collider (EIC). We present beam test results of the AstroPix_v3 sensor using a 120 GeV proton beam at the Fermilab Test Beam Facility (FTBF), performed as part of the broader experimental campaign for the BIC prototype calorimeter. The sensor’s 500 µm pixel pitch enabled precise measurement of the beam profile, providing important information for the calorimeter performance studies. Using the measured 120 GeV proton data, we measure the energy deposit of minimum ionizing particles (MIP) and use them to extract the corresponding effective depletion depth at a single bias voltage of −150 V .

AstroPix↗

Electromagnetic ion cyclotron waves stimulated by modest magnetospheric compressions

AMPTE/CCE magnetic field and particle data are used to test the suggestion that increased hot proton temperature anisotropy resulting from convection during magnetospheric compression is responsible for the enhancement in Pc 1 emission via generation of electromagnetic ion cyclotron (EMIC) waves in the dayside outer equatorial magnetosphere. The relative increase in magnetic field is used to gauge the strength of the compression, and an image dipole model is used to estimate the motion of the plasma during compression. Proton data are used to analyze the evolution of the proton distribution and the corresponding changes in EMIC wave activity expected during the compression. It is suggested that enhancements in dynamic pressure pump the energetic proton distributions in the outer magnetosphere, driving EMIC waves. Waves are expected to be generated most readily close to the magnetopause, and transient pressure pulses may be associated with bursts of EMIC waves, which would be observed on the ground in association with ionospheric transient signatures.

Anderson, B. J.↗

A high-granularity calorimeter insert based on SiPM-on-tile technology at the future Electron-Ion Collider

Herein we present a design for a high-granularity calorimeter insert for future experiments at the Electron-Ion Collider (EIC). The sampling-calorimeter design uses scintillator tiles read out with silicon photomultipliers. It maximizes coverage close to the beampipe, while solving challenges arising from the beam-crossing angle and mechanical integration. It yields a compensated response that is linear over the energy range of interest for the EIC. Its energy resolution meets the requirements set in the EIC Yellow Report even with a basic reconstruction algorithm. Moreover, this detector will provide 5D shower data (position, energy, and time), which can be exploited with machine-learning techniques. This detector concept has the potential to unleash the power of imaging calorimetry at the EIC to enable measurements at extreme kinematics in electron–proton and electron–nucleus collisions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Differentiating multi-MeV, multi-ion spectra with CR-39 solid-state nuclear track detectors

The development of high intensity petawatt lasers has created new possibilities for ion acceleration and nuclear fusion using solid targets. In such laser-matter interaction, multiple ion species are accelerated with broad spectra up to hundreds of MeV. To measure ion yields and for species identification, CR-39 solid-state nuclear track detectors are frequently used. However, these detectors are limited in their applicability for multi-ion spectra differentiation as standard image recognition algorithms can lead to a misinterpretation of data, there is no unique relation between track diameter and particle energy, and there are overlapping pit diameter relationships for multiple particle species. In this report, we address these issues by first developing an algorithm to overcome user bias during image processing. Second, we use calibration of the detector response for protons, carbon and helium ions (alpha particles) from 0.1 to above 10 MeV and measurements of statistical energy loss fluctuations in a forward-fitting procedure utilizing multiple, differently filtered CR-39, altogether enabling high-sensitivity, multi-species particle spectroscopy. To validate this capability, we show that inferred CR-39 spectra match Thomson parabola ion spectrometer data from the same experiment. Filtered CR-39 spectrometers were used to detect, within a background of ~ 2 × 10 11 sr -1 J -1 protons and carbons, (1.3 ± 0.7) × 10 8 sr -1 J -1 alpha particles from laser-driven proton-boron fusion reactions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Mars 2001 Athena Precursor Experiment (APEX)

The Athena Precursor Experiment (APEX) is a suite of scientific instruments for the Mars Surveyor Program 2001 (MSP'01) lander. The major elements of the APEX pay load are: (1) Pancam/Mini-TES, a combined stereo color imager and mid-infrared point spectrometer. (2) An Alpha-Proton-X-Ray Spectrometer (APXS) for in-situ elemental analysis. (3) A Mossbauer Spectrometer for in-situ determination of the mineralogy of Fe-bearing rocks and soils. (4) A Magnet Array that can separate magnetic soil particles from non-magnetic ones.

Squyres, S. W.↗

Mars Pathfinder Microrover - Implementing a Low Cost Planetary Mission Experiment

The Mars Pathfinder Microrover Flight Experiment (MFEX) is a NASA OACT flight experiment which is planned to be delivered and integrated with the Mars Pathfinder (MFP) lander and spacecraft system for landing on Mars on July 4, 1997. After landing, the MFEX rover is deployed from the lander and begins a 7 sol (1 sol=1 Martian day) mission to conduct technology experiments, deploy an alpha proton x-ray spectrometer (APXS) on rocks and soil, and image the lander as part of the engineering assessment of the mission after landing.

Mars Pathfinder↗

Magnetic Resonance Imaging of Ventilation and Perfusion in the Lung

Methods, devices, and systems are disclosed for implementing a fully quantitative non-injectable contrast proton MRI technique to measure spatial ventilation-perfusion (VA/Q) matching and spatial distribution of ventilation and perfusion. In one aspect, a method using MRI to characterize ventilation and perfusion in a lung includes acquiring an MR image of the lung having MR data in a voxel and obtaining a breathing frequency parameter, determining a water density value, a specific ventilation value, and a perfusion value in at least one voxel of the MR image based on the MR data and using the water density value to determine an air content value, and determining a ventilation-perfusion ratio value that is the product of the specific ventilation value, the air content value, the inverse of the perfusion value, and the breathing frequency.

Prisk, Gordon Kim↗

Dosimetric delivery validation of dynamically collimated pencil beam scanning proton therapy

Pencil beam scanning (PBS) proton therapy target dose conformity can be improved with energy layer-specific collimation. One such collimator is the dynamic collimation system (DCS), which consists of four nickel trimmer blades that intercept the scanning beam as it approaches the lateral extent of the target. While the dosimetric benefits of the DCS have been demonstrated through computational treatment planning studies, there has yet to be experimental verification of these benefits for composite multi-energy layer fields. The objective of this work is to dosimetrically characterize and experimentally validate the delivery of dynamically collimated proton therapy with the DCS equipped to a clinical PBS system. Approach. Optimized single field, uniform dose treatment plans for 3 × 3 × 3 cm 3 target volumes were generated using Monte Carlo dose calculations with depths ranging from 5 to 15 cm, trimmer-to-surface distances ranging from 5 to 18.15 cm, with and without a 4 cm thick polyethylene range shifter. Treatment plans were then delivered to a water phantom using a prototype DCS and an IBA dedicated nozzle system and measured with a Zebra multilayer ionization chamber, a MatriXX PT ionization chamber array, and Gafchromic™ EBT3 film. Main results. For measurements made within the SOBPs, average 2D gamma pass rates exceeded 98.5% for the MatriXX PT and 96.5% for film at the 2%/2 mm criterion across all measured uncollimated and collimated plans, respectively. For verification of the penumbra width reduction with collimation, film agreed with Monte Carlo with differences within 0.3 mm on average compared to 0.9 mm for the MatriXX PT. Significance. We have experimentally verified the delivery of DCS-collimated fields using a clinical PBS system and commonly available dosimeters and have also identified potential weaknesses for dosimeters subject to steep dose gradients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗