Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION CONTROL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

FRIB Beam Power Ramp-up: Status and Plans

After project completion on scope, on cost, and ahead of schedule, the Facility for Rare Isotope Beams began operations for scientific users in May of 2022. The ramp-up to a beam power of 400 kW is planned over a six-year period; 1 kW was delivered for initial user runs from in 2022, and 5 kW was delivered as of February 2023. Test runs with 10 kW 36Ar and 48Ca beams were conducted in July 2023. Upgrade plans include doubling the primary-beam energy to 400 MeV/nucleon for enhanced discovery potential (¿FRIB 400¿). This talk reports on the strategic plans towards high power operations emphasizing challenges and resolutions in beam-interception devices and targetry systems, radiation protection and controls, and legacy system renovation and integration.

43 PARTICLE ACCELERATORS↗

The Early Career Research Program Annual Progress Report: Using ARM Data and Multiscale Models to Advance the Understanding of Liquid-Phase Cloud Response to Aerosol Perturbation over Ocean and Land

This project aims to study the response of liquid-phase clouds to aerosol perturbation and reduce the related uncertainty in the DOE Earth system model. Specific objectives include: Objective 1: Quantify the aerosol indirect effect on liquid-phase clouds using ARM observations and satellite retrievals while constraining the confounding large-scale conditions; Objective 2: Harness LES case studies, untangle the confounding meteorological impacts on the observed aerosol indirect effect, and identify key cloud processes controlling the net radiative forcing of aerosol-cloud interactions at different spatiotemporal scales; Objective 3: Evaluate the aerosol indirect effect on liquid-phase clouds with process-level understanding in E3SM multiscale model configurations.

54 ENVIRONMENTAL SCIENCES↗

Simulations Supporting the Development of Northstar's Indirect Beam Parameters Monitoring System

NorthStar Medical Radioisotopes, LLC is planning to produce the important medical radioisotope molybdenum-99 (Mo-99), the parent of technetium-99m (Tc-99m), through photonuclear reactions in molybdenum-100 (Mo-100). In this approach, a target comprising multiple thin disks of enriched molybdenum metal is bombarded with a 40-MeV electron beam. Electrons impinged on the molybdenum target produce bremsstrahlung X-rays that cause the nuclear reaction. Because enriched Mo-100 is expensive, there is a desire to utilize as much beam power as possible to achieve maximum production yield and minimize the size of the target. This requirement leads to very high beam power density (and heat deposition in the target), which creates challenging requirements for the cooling of the target. The critical part of the target is the target window. It separates the high-pressure helium cooled target from the vacuum beamline and the subject of structural and thermal stress. The temperature of the target window is proportional to the energy density deposited by the beam, so it is critical to maintain the desired beam profile on the target window. The feasibility of indirectly monitoring the maximum energy density of the beam on the beam window through beam losses at the main collimator (Collimator) before the production target was verified. A model of the NorthStar beam transport line was constructed for this purpose using MAD-X and Tao/Bmad codes. Beam optics were computed for the standard operational scenario, followed by an investigation involving approximately 400 cases with parameter variations in the last tuning quadrupoles. This was done to assess the correlation between losses in the collimator and the peak energy density on the target. We developed a model to explore the potential application of Optical transition radiation (OTR) for controlling beam parameters in the NorthStar beam delivery system. This model was based on a generic formula derived from the fundamental solution of the inhomogeneous wave equation of the vector potential, and allowed us to consider various surfaces, even those with irregular or random features, using numerical integration. We applied the model to OTR generated by relativistic electrons impacting an Inconel® 718 beam window. We examined cases with different levels of the window’s surface roughness, ranging from 0.5 to 3.0 microns of root square mean (RMS) deviation. The results of the OTR simulations provided distributions of OTR photons that can be used to study the limitations of optical systems for controlling beam parameters.

43 PARTICLE ACCELERATORS↗

SpinQuest Polarized Target System

The SpinQuest experiment at Fermilab uses a solid-state polarized ammonia target held at a magnetic field of 5 T, immersed in liquid helium-4, which is held at approximately 1K by the evaporation refrigerator. The refrigerator provides the required cooling power during the dynamic nuclear polarization (DNP) process and the high intensity interaction with the 120 GeV proton beam from the Fermilab main injector. The refrigerator was designed in compliance with the American Society of Mechanical Engineers (ASME) to operate safely at Fermilab. The high pumping capacity ($17,000 \:m^3/h$) roots stack provides the required pumping speed during DNP production data taking and a custom-made radiation hard flow control valve regulates the refrigerator temperature during the thermal equilibrium calibration measurements. The frequency of the microwave generator, an Extended Interaction Oscillator (EIO), is automated to keep the maximum polarization while the (Nuclear Magnetic Resonance) NMR system continuously measures the polarization of the target material. In this talk, an overview of the SpinQuest polarized target system will be presented as well as a brief report of recent commissioning activities and target performance during the early production runs in 2024.

Bandara, Vibodha [Colombo U.]↗

Temperature-tuned ultrafast X-ray shutter using optics-on-a-chip

Typically modulation systems are incapable of performing synchronous modulation for high-energy radiation systems. A method and system for performing high-energy synchronous radiation modulating is described. The method includes providing an oscillatory diffractive element, with the oscillatory diffractive element capable of being oscillated over a range of angles. A radiation source provides radiation to the oscillatory diffractive element. An electrical signal is provided to electrodes that oscillate the oscillatory diffractive element to modulate the radiation. A temperature controller controls the temperature of the oscillatory diffractive element to tune the oscillatory motion of the oscillatory diffractive element.

Wang, Jin↗

Patient-Reported Outcomes From a Phase 3 Randomized Controlled Trial Exploring Optimal Sequencing of Short-Term Androgen Deprivation Therapy With Prostate Radiation Therapy in Localized Prostate Cancer

Two phase 3 randomized controlled trials (OTT-0101, RTOG-9413) and a meta-analysis have shown an impact of sequencing of androgen deprivation therapy (ADT) and radiation therapy on oncologic outcomes in prostate cancer (PCa). However, the impact of sequencing strategy on health-related quality of life (HR-QoL) is unclear. Here, we present the patient-reported HR-QoL outcomes from the OTT-0101 study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimeter Area Monitoring Program (DAMP) Technical Basis Document

This document provides a technical basis for establishing a Dosimetry-based Area Monitoring Program (DAMP) at Lawrence Livermore National Laboratory (LLNL). A DAMP is part of a comprehensive routine monitoring program and provides information about radiation levels inside and outside of Radiologically-Controlled Areas (RCAs). The routine, hand-held radiation survey program driven by the Health Physics Discipline Action Plan (HP-DAP) helps to ensure radiological conditions within RCAs are well-characterized and routinely monitored; however, such surveys are a snapshot in time, whereas area monitoring dosimeters (AMDs) continuously monitor radiation doses in the areas where they are installed. Together, data from the hand-held radiation surveys and the DAMP provides a comprehensive picture of radiation environment at LLNL. A DAMP helps to verify the effectiveness of established engineered and administrative controls while documenting that radiation doses in RCAs are below that which requires individual monitoring. This document establishes the basis for determining which model of dosimeter to use, the exchange frequency, the occupancy factor, monitoring locations, and a method for evaluating AMD results.

61 RADIATION PROTECTION AND DOSIMETRY↗

Preclinical Risk Evaluation of Normal Tissue Injury With Novel Radiosensitizers

Genotoxic damage induced by radiation triggers a highly coordinated DNA damage response, and molecular inhibitors of key nodes within this complex response network can profoundly enhance the antitumor efficacy of radiation. This is especially true for drugs targeting the catalytic subunit of DNA-dependent protein kinase, which is a core component of the nonhomologous end-joining DNA repair pathway, and ataxia telangiectasia mutated, which coordinates cell cycle arrest, apoptosis, and DNA repair functionalities after radiation exposure. Unlike the more modest in vitro radiosensitizing effects seen with classic sensitizing agents such as cisplatin, 5-fluorouracil, or taxanes, DNA-dependent protein kinase or ataxia telangiectasia mutated inhibitors provide much more robust sensitizing effects in vitro, as might be anticipated from targeting these key DNA repair modulators. However, patients with homozygous inactivating mutations of ataxia telangiectasia mutated or mice with homozygous defects in DNA-dependent protein kinase (severe combined immunodeficiency) have profoundly enhanced acute normal tissue radiation reactions. Therefore, there is significant potential that the combination of small molecule inhibitors of these kinases with radiation could cause similar dose-limiting acute normal tissue toxicities. Similarly, although less understood, inhibition of these DNA repair response pathways could markedly increase the risk of late radiation toxicities. Because these potent radiosensitizers could be highly useful to improve local control of otherwise radiation-resistant tumors, understanding the potential for elevated risks of radiation injury is essential for optimizing therapeutic ratio and developing safe and informative clinical trials. In this review, we will discuss 2 straightforward models to assess the potential for enhanced mucosal toxicity in the oral cavity and small intestine established in our laboratories. We also will discuss similar strategies for evaluating potential drug–radiation interactions with regard to increased risks of debilitating late effects.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Near-field-driven radiative thermal dynamics in aperiodic photonic nanostructures

Harnessing structural correlations in near-field plasmonic and polaritonic systems hold untapped potential for controlling light–matter interactions at the nanoscale. By tuning these correlations, one can reshape mode localization, coupling, and spectral distribution which are properties central to manipulating energy transport and field enhancement in nanophotonic platforms. We exploit Vogel spirals, an aperiodic geometry where a single parameter dictates spatial correlations, to show how correlation strength reshapes the modal spectrum and transient dynamics of near-field coupling. As a proof of concept, we demonstrate that aperiodic configurations outperform both uncorrelated (random) and periodic arrays in controlling near-field radiative heat-transfer dynamics. These results establish deterministic aperiodic order as a powerful platform for tailoring correlated electromagnetic responses in next-generation nanophotonic devices.

36 MATERIALS SCIENCE↗

Stereotactic Body Radiation Therapy With a High Maximum Dose Improves Local Control, Cancer-Specific Death, and Overall Survival in Peripheral Early-Stage Non-Small Cell Lung Cancer

We investigated whether delivery of a high biologically effective dose (BED) to primary tumors affects systemic outcomes of cancer-specific death (CSD) and overall survival (OS) rates after stereotactic body radiation therapy (SBRT) in patients with early-stage non-small cell lung cancer (ES-NSCLC).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Progress of Divertor Heat and Particle Flux Control in EAST for Advanced Steady-State Operation in the Last 10 Years

Active control of the excessively high heat and particle fluxes on the divertor target plates is of fundamental importance to the steady state operation of tokamaks, especially for fusion reactors. A series of experiments have been carried out on this critical issue to relieve the plasma-wall interactions in the experimental advanced superconducting tokamak (EAST) in the last ten years, not only contributing to the long pulse operation of EAST itself, but also providing physical understandings and potential techniques to the next-generation devices like ITER. Here we have characterized the power deposition pattern and broadened the divertor footprint width effectively. The plasma-wetted area is actively handled using either 3-dimentional edge magnetic topology or advanced plasma equilibrium, thereby peak heat flux around the strike point is reduced. Active control of detachment or radiation compatible with core plasma performance has progressed significantly in very recent years, with a series of active feedback control modules developed and utilized successfully, based on the divertor physics advances with both experiments and simulation. The upper divertor of EAST was upgraded from graphite to active water-cooling ITER-like tungsten in 2014, exhibiting much enhanced heat removal capability. As for the particle exhaust including both fueling and impurity particles, in addition to wall conditioning and impurity source control, the efficiency of particle flux exhaust is optimized by making full use of the divertor closure and the plasma drifts in both scrape-off layer and divertor volume. These heat and particle exhaust advances contribute greatly to a series of EAST achievements like H-mode operation over 100 s. A brief near-term plan on the integrated control of divertor plasma-wall interactions in long-time scale will also be introduced, aiming to provide favorable divertor operation solution for ITER and CFETR.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

3D radiated power analysis of JET SPI discharges using the Emis3D forward modeling tool

Abstract Precise values for radiated energy in tokamak disruption experiments are needed to validate disruption mitigation techniques for burning plasma tokamaks like ITER and SPARC. Control room analysis of radiated power ( P rad ) on JET assumes axisymmetry, since fitting 3D radiation structures with limited bolometry coverage is an under-determined problem. In mitigated disruptions, radiation is toroidally asymmetric and 3D, due to fast-growing 3D MHD modes and localized impurity sources. To address this problem, Emis3D adopts a physics motivated forward modeling (‘guess and check’) approach, comparing experimental bolometry data to synthetic data from user-defined radiation structures. Synthetic structures are observed with the Cherab modeling framework and a best fit chosen using a reduced χ 2 statistic. 2D tomographic inversion models are tested, as well as helical flux tubes and 3D MHD simulated structures from JOREK. Two nominally identical pure neon shattered pellet injection (SPI) mitigated discharges in JET are analyzed. 2D tomographic inversions with added toroidal freedom are the best fits in the thermal quench (TQ) and current quench (CQ). In the pre-TQ, 2D reconstructions are statistically the best fits, but are likely over-optimized and do not capture the 3D radiation structure seen in fast camera images. The next-best pre-TQ fits are helical structures that extend towards the high-field side, consistent with an impurity flow under the magnetic nozzle effect also observed in JOREK simulations. Whole-disruption radiated fractions of 0.98 + 0.03 / − 0.29 and 1.01 + 0.02 / − 0.17 are found, suggesting that the stored energy may have been fully mitigated by each SPI, although mitigation efficiencies well below ITER and SPARC requirements for high energy pulses are still within the large uncertainties. Emis3D is also used to validate JOREK SPI simulations, and confirms improvements in matching experiment from changes to impurity modeling. Time-dependent toroidal peaking factors are calculated and discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observations of Fog-Aerosol Interactions Over Central Greenland

Supercooled fogs can have an important radiative impact at the surface of the Greenland Ice Sheet, but they are difficult to detect and our understanding of the factors that control their lifetime and radiative properties is limited by a lack of observations. This study demonstrates that spectrally resolved measurements of downwelling longwave radiation can be used to generate retrievals of fog microphysical properties (phase and particle effective radius) when the fog visible optical depth is greater than ~0.25. For 12 cases of fog under otherwise clear skies between June and September 2019 at Summit Station in central Greenland, nine cases were mixed-phase. The mean ice particle (optically-equivalent sphere) effective radius was 24.0 ± 7.8 µm, and the mean liquid droplet effective radius was 14.0 ± 2.7 µm. These results, combined with measurements of aerosol particle number concentrations, provide evidence supporting the hypotheses that (a) low surface aerosol particle number concentrations can limit fog liquid water path, (b) fog can act to increase near-surface aerosol particle number concentrations through enhanced mixing, and (c) multiple fog events in quiescent periods gradually deplete near-surface aerosol particle number concentrations.

54 ENVIRONMENTAL SCIENCES↗

The Oral CXCR4 Inhibitor X4-136 Improves Tumor Control and Reduces Toxicity in Cervical Cancer Treated With Radiation Therapy and Concurrent Chemotherapy

Cervical cancer is a global health problem. Despite the growth of prevention programs, there is an important need to improve the effectiveness of treatment for patients with invasive, locally advanced disease. In this study we examined (1) the efficacy of radiation therapy (RT) with cisplatin (RTCT) and an orally administered CXCR4 inhibitor suitable for clinical use, X4-136; (2) biomarkers of response to RTCT and X4-136; and (3) intestinal toxicity from RTCT and X4-136.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Association of Short-term Patient-reported Outcomes With Long-term Oncologic Outcomes in Localized Prostate Cancer Patients Treated With Radiation Therapy and Androgen Deprivation Therapy in a Randomized Controlled Trial

Both oncologic outcomes and patient-reported outcomes are pivotal in prostate cancer (PCa). However, it remains unknown if there is any association between these 2 outcomes. In this secondary analysis of a randomized controlled trial, we investigated the association of short-term changes in patient-reported outcome with long-term event-free survival (EFS) and metastasis-free survival (MFS) in localized PCa.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Heavy-Ion-Induced Lung Tumors: Dose- & LET-Dependence

There is a limited published literature reporting dose-dependent data for in vivo tumorigenesis prevalence in different organs of various rodent models after exposure to low, single doses of charged particle beams. The goal of this study is to reduce uncertainties in estimating particle-radiation-induced risk of lung tumorigenesis for manned travel into deep space by improving our understanding of the high-LET-dependent dose-response from exposure to individual ion beams after low particle doses (0.03 - 0.80 Gy). Female CB6F1 mice were irradiated with low single doses of either oxygen, silicon, titanium, or iron ions at various energies to cover a range of dose-averaged LET values from 0.2 - 193 keV/µm, using 137Cs γ-rays as the reference radiation. Sham-treated controls were included in each individual experiment totally 398 animals across the 5 studies reported. Based on power calculations, between 40 - 156 mice were included in each of the treatment groups. Tumor prevalence at 16 months after radiation exposure was determined and compared to the age-matched, sham-treated animals. Results indicate that lung tumor prevalence is non-linear as a function of dose with suggestions of threshold doses depending on the LET of the beams. Histopathological evaluations of the tumors showed that the majority of tumors were benign bronchioloalveolar adenomas with occasional carcinomas or lymphosarcomas which may have resulted from metastases from other sites.

60 APPLIED LIFE SCIENCES↗

Investigation of divertor detachment induced through neon seeding and density ramp on HL-3

A new self-consistent 1D scrape-off layer model has been recently developed in BOUT++ framework, named SD1D, which includes equations for various particle species (e.g. main plasma, neutrals and impurities) and couples open databases like ADAS and AMJUEL. It is able to quickly and effectively simulate divertor detachment experiments. In this work, a typical detachment experiment (shot #6270) on HL-3 with neon seeding is simulated using the SD1D code. It is found that the target electron temperature and the target ion saturation current in the simulations are consistent with experimental results measured by Langmuir probes on the target plate. The variation of D α radiation intensity in the divertor is qualitatively similar to the measured D α signal. Following the experimental validations, different upstream densities are set in the simulations to study the impurity distribution under different plasma density conditions. It is found that increasing upstream density can be helpful for the control of the neon radiation front (closer to the target). In this work we also compare two detachment regimes in simulations. Based on the same initial experimental parameters (shot #6270) on HL-3, a scan of upstream density and a scan of neon seeding rate are carried out respectively. It is found that the role of atomic and molecular processes is different in the two detachment regimes. The current density roll-over is ascribed to a drop in the divertor ion source, and the variation of D α radiation intensity via different excitation channels is associated with the relevant collisional reaction sources.

BOUT++↗