Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION COUNTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Observations of the Van Allen Radiation Regions During August and September 1959

An integrating ionization chamber and a single Geiger counter were flown on United States satellite Explorer VI in an elliptical orbit extending to 48,000 km. In addition to the Van Allen inner zone and the great outer zone, a stable and distinct intermediate zone was detected throughout August and September 1959. The outer-zone intensity showed a large decrease following the sudden commencement of a geomagnetic storm. Later in the storm the outer zone increased to much in excess of its prestorm level. During stable periods the outer zone was fairly constant and less intense than it had been observed to be with Pioneer III or Pioneer IV or the first Soviet cosmic rocket. Cosmic-ray background counting rates were reached on most passes in August and Septmeber near apogee of the satellite. The radiation ?dumped? from the outer zone during the geomagnetic storm fits very well with the intensity and latitude distribution required to account for balloon observations of auroral X rays made during the IGY period. This paper is based on preliminary analysis of Explorer VI data.

Arnoldy, R. L.↗

Spiral clouds on Mars - A new atmospheric phenomenon

Viking Orbiter images obtained during the 1978 northern summer on Mars show unusual spiral cloud patterns at high northern latitudes. Well-developed spirals occurred only during early summer at a time when the sublimation of the annual CO2 frost cap in the north had ceased. The systems ranged in size from 200 to 500 km and all spirals were wound in a counter-clockwise sense. An explanation is proposed, based on the radiatively driven instability described by Gierasch, Ingersoll, and Williams. The model predicts disturbances with the correct scale and lifetime. However, the successful development of the spirals depends on the existence of weak mean winds, suggesting that these instabilities can only develop at special null points in the general circulation. It is argued that such special circumstances are most likely to occur during early northern summer and are less likely to obtain at a comparable season in the Southern Hemisphere.

Gierasch, P.↗

MSFC Investigations of Beta Cloth Darkening Due to Ultraviolet Radiation Interactions

A common component of multi-layer insulation blankets is beta cloth, a woven fiberglass cloth impregnated with Teflon. It is planned for extensive use on the International Space Station (ISS). The Environmental Effects Group of the Marshall Space Flight Center Materials, Processing and Manufacturing Department has investigated the impact of atomic oxygen (AO) and ultraviolet (UV) radiation on the optical properties of plain and aluminized beta cloth, both in the laboratory and as part of long-duration flight experiments. These investigations indicate that beta cloth was susceptible to darkening in the presence of UV radiation, dependent on the additives used. The presence of AO countered some, if not all, of the UV degradation.

Kamenetzky, Rachel R.↗

Radiation measured with TEPC and CR-39 PNTDs in low Earth orbit

The radiation impact to astronauts depends strongly on the particles linear energy transfer (LET) and is dominated by high LET radiation. It is important to investigate the LET spectrum for the radiation field in low Earth orbit (LEO) and the influence of radiation on astronauts. The best active dosimeter used for all LET is the tissue equivalent proportional counter (TEPC); the best passive dosimeter used for high LET is CR-39 plastic nuclear track dosimeter (PNTD). TEPC and CR-39 PNTDs were used to investigate the radiation in LEO. LET spectra and radiation quantities were obtained for STS-112 and STS-114 missions with TEPC and CR-39 PNTDs. This paper introduces the operation principles for the two types of dosimeters, presents radiation results measured and compares the results obtained with different dosimeters.

Zhou, D.↗

The analysis of X-ray spectra.

Systematic analysis program for proportional counter X ray spectral observations of celestial objects, considering interaction between radiation field and detector

Garmire, G.↗

Support of research in X-ray astronomy

Activities described include: (1) the evaluation of CCD detectors for X-ray astronomy applications; (2) contributions to the development of an imaging gas scintillation proportional counter; (3) the evaluation of certain metal oxide crystals as potential radiation detectors; (4) optical observations and searches for X-ray sources discovered by the HEAO-1 A2 experiment; and (5) theoretical modeling of nonequilibrium ionization structure of supernova remnants.

Garmire, G.↗

TEPC Response Functions

The tissue equivalent proportional counter had the purpose of providing the energy absorbed from a radiation field and an estimate of the corresponding linear energy transfer (LET) for evaluation of radiation quality to convert to dose equivalent. It was the recognition of the limitations in estimating LET which lead to a new approach to dosimetry, microdosimetry, and the corresponding emphasis on energy deposit in a small tissue volume as the driver of biological response with the defined quantity of lineal energy. In many circumstances, the average of the lineal energy and LET are closely related and has provided a basis for estimating dose equivalent. Still in many cases the lineal is poorly related to LET and brings into question the usefulness as a general purpose device. These relationships are examined in this paper.

Shinn, J. L.↗

Twenty Years of Radiation Measurements in Low-Earth Orbit - What Have We Learned Space Radiation Environment?

The advent of the Space Shuttle program has made possible space radiation environment measurements spanning a wide range of altitudes and orbital inclinations over multiple solar cycles. These measurements range from routine integral dose measurements with thermoluminescent dosimeters to particle energy spectra measurements made with a charged particle telescope. This paper will review the new understanding about the space radiation environment gained from this diverse data set. Major findings from these measurements include: estimations of the westward drift rate of the South Atlantic Anomaly (SAA) of 0.28-0.49/y; evidence for a northward component to the SAA drift of 0.08-0.12/y; observation of the formation and decay of the pseudo-stable additional radiation belt following the Mar 1991 SPE and geomagnetic storm with an estimated decay e-folding time of 9-10 months; observation of a local geomagnetic east-west trapped proton exposure anisotropy with an estimated magnitude of 1.6-3.3; demonstration that the trapped proton exposure in low-Earth orbit (LEO) can be reasonably modeled as a power law function of atmospheric density in the SAA region, with best correlations obtained when the exospheric temperature saturates at 938-975 K; the actual solar cycle modulation of trapped proton exposure in LEO is less than predicted by the AP8 model; and the testing and validation of GCR flux models, radiation transport codes, and dynamic geomagnetic cutoff models. Long-term, time-resolved proportional counter measurements made aboard the Mir during the same period provides further demonstration of the solar cycle modulation of the trapped protons at low altitudes - the observed modulation is also well described as power law function of atmospheric density. These data and findings have helped to improve the overall accuracy of pre-mission crew exposure projections using various semi-empirical space environment models, radiation transport codes, and spacecraft radiation shielding models. During the rise phase of solar cycle 22 (1987-1991), the RMS error between preflight exposure projections and measured crew exposure was 73%. For the rise phase of cycle 23 (1997-2001), the preflight exposure projection RMS error has decreased to 23%. The launch and assembly of the Space Station has begun a new era of long-term LEO space environment monitoring. The radiation environment at the Space Station will be monitored with three external charged particle telescopes oriented in the velocity vector, anti-velocity vector, and zenith directions. Data from the telescopes will provide charge, mass, energy, and arrival direction for incident particles with energy to mass ratios of 13- 450 MeV/amu and Z of 1-24. The external environment data will be complimented by measurements from a portable charged particle telescope and proportional counter located inside the vehicle.

Golightly, Michael J.↗

Comparison of graphite, aluminum, and TransHab shielding material characteristics in a high-energy neutron field

Space radiation transport models clearly show that low atomic weight materials provide a better shielding protection for interplanetary human missions than high atomic weight materials. These model studies have concentrated on shielding properties against charged particles. A light-weight, inflatable habitat module called TransHab was built and shown to provide adequate protection against micrometeoroid impacts and good shielding properties against charged particle radiation in the International Space Station orbits. An experiment using a tissue equivalent proportional counter, to study the changes in dose and lineal energy spectra with graphite, aluminum, and a TransHab build-up as shielding, was carried out at the Los Alamos Nuclear Science Center neutron facility. It is a continuation of a previous study using regolith and doped polyethylene materials. This paper describes the results and their comparison with the previous study. Published by Elsevier Science Ltd.

NASA Center JSC↗

Radiation Measured with Different Dosimeters for ISS-Expedition 18-19/ULF2 on Board International Space Station during Solar Minimum

Radiation field of particles in low Earth orbit (LEO) is mainly composed of galactic cosmic rays (GCR), solar energetic particles and particles in SAA (South Atlantic Anomaly). GCR are modulated by solar activity, at the period of solar minimum activity, GCR intensity is at maximum and the main contributor for space radiation is GCR. At present for space radiation measurements conducted by JSC (Johnson Space Center) SRAG (Space Radiation Analysis Group), the preferred active dosimeter sensitive to all LET (Linear Energy Transfer) is the tissue equivalent proportional counter (TEPC); the preferred passive dosimeters are thermoluminescence dosimeters (TLDs) and optically stimulated luminescence dosimeters (OSLDs) sensitive to low LET as well as CR-39 plastic nuclear track detectors (PNTDs) sensitive to high LET. For the method using passive dosimeters, radiation quantities for all LET can be obtained by combining radiation results measured with TLDs/OSLDs and CR-39 PNTDs. TEPC, TLDs/OSLDs and CR-39 detectors were used to measure the radiation field for the ISS (International Space Station) - Expedition 18-19/ULF2 space mission which was conducted from 15 November 2008 to 31 July 2009 - near the period of the recent solar minimum activity. LET spectra (differential and integral fluence, absorbed dose and dose equivalent) and radiation quantities were measured for positions TEPC, TESS (Temporary Sleeping Station, inside the polyethylene lined sleep station), SM-P 327 and 442 (Service Module - Panel 327 and 442). This paper presents radiation LET spectra measured with TEPC and CR-39 PNTDs and radiation dose measured with TLDs/OSLDs as well as the radiation quantities combined from results measured with passive dosimeters.

Zhou, Dazhuang↗

In-flight radiation measurements on STS-60

A joint investigation between the United States and Russia to study the radiation environment inside the Space Shuttle flight STS-60 was carried out as part of the Shuttle-Mir Science Program (Phase 1). This is the first direct comparison of a number of different dosimetric measurement techniques between the two countries. STS-60 was launched on 3 February 1994 in a nearly circular 57 degrees x 353 km orbit with five U.S. astronauts and one Russian cosmonaut for 8.3 days. A variety of instruments provided crew radiation exposure, absorbed doses at fixed locations, neutron fluence and dose equivalent, linear energy transfer (LET) spectra of trapped and galactic cosmic radiation, and energy spectra and angular distribution of trapped protons. In general, there is good agreement between the U.S. and Russian measurements. The AP8 Min trapped proton model predicts an average of 1.8 times the measured absorbed dose. The average quality factor determined from measured lineal energy, y, spectra using a tissue equivalent proportional counter (TEPC), is in good agreement with that derived from the high temperature peak in the 6LiF thermoluminescent detectors (TLDs). The radiation exposure in the mid-deck locker from neutrons below 1 MeV was 2.53 +/- 1.33 microSv/day. The absorbed dose rates measured using a tissue equivalent proportional counter, were 171.1 +/- 0.4 and 127.4 +/- 0.4 microGy/day for trapped particles and galactic cosmic rays, respectively. The combined dose rate of 298.5 +/- 0.82 microGy/day is about a factor of 1.4 higher than that measured using TLDs. The westward longitude drift of the South Atlantic Anomaly (SAA) is estimated to be 0.22 +/- 0.02 degrees/y. We evaluated the effects of spacecraft attitudes on TEPC dose rates due to the highly anisotropic low-earth orbit proton environment. Changes in spacecraft attitude resulted in dose-rate variations by factors of up to 2 at the location of the TEPC.

NASA Discipline Radiation Health↗

Radiation Measured during ISS-Expedition 13 with Different Dosimeters

Radiation in low Earth orbit (LEO) is mainly composed of Galactic Cosmic Rays (GCR), solar energetic particles and particles in SAA (South Atlantic Anomaly). The biological impact of space radiation to astronauts depends strongly on the particles linear energy transfer (LET) and is dominated by high LET radiation. It is important to measure the LET spectrum for the space radiation field and to investigate the influence of radiation on astronauts. At present, the preferred active dosimeters sensitive to all LET are the tissue equivalent proportional counter (TEPC) and silicon detectors in various configurations; the preferred passive dosimeters are thermoluminescence dosimeters (TLDs) and optically stimulated luminescence dosimeters (OSLDs) sensitive to low LET as well as CR-39 plastic nuclear track detectors (PNTDs) sensitive to high LET. The TEPC, CR-39 PNTDs, TLDs and OSLDs were used to investigate the radiation exposure for the ISS mission Expedition 13 (ISS-12S) in LEO. LET spectra and radiation quantities (fluence, absorbed dose, dose equivalent and quality factor) were measured for the space mission with different dosimeters. This paper introduces the operational principles for the dosimeters, describes the method to combine the results measured by TLDs/OSLDs and CR-39 PNTDs, and presents the LET spectra and the radiation quantities measured. Keywords: space radiation; cosmic rays; active and passive dosimeters; LET spectra

Zhou, D.↗

Radiation Shielding Plasma Sprayed Coatings Heads to International Space Station for MISSE-17 Experiments

NASA's Artemis program aims to return to the moon in search of scientific discoveries and establish a habitat using in-situ resource utilization. However, the past lunar explorations presented challenges, such as thermal cycles, solar and intergalactic cosmic radiation, and severe abrasive interaction of sharp lunar regolith particles[1]–[4].Dust mitigation and radiation shielding have become the most important concerns for lunar structural components and rovers which can fail abruptly without a protective solution. To counter these threats, Plasma Forming Laboratory(PFL) at Florida International University (FIU), in collaboration with NASA, has developed a novel multi-functional coating to protect the components synergistically against abrasion, erosion ,and radiation. The titanium-boron nitride composite coatings were prepared using the atmospheric plasma spray technique from engineered composite powders [5], [6].The coatings were subjected to extensive characterization and tribological study with lunar mare simulant JSC-1A, which shows tremendous improvement in the wear performance. The coatings subjected to neutron radiation shielding experiments at NASA Langley Research Center exhibited significantly improved neutron attenuation capacity compared to the substrate. The coating is selected to undergo radiation exposure on the International Space Station as a part of MISSE-17 (Materials International Space Station Experiment).

Thermal Spray↗

Integrated Orbit, Attitude, and Structural Control Systems Design for Space Solar Power Satellites

The major objective of this study is to develop an integrated orbit, attitude, and structural control systems architecture for very large Space Solar Power Satellites (SSPS) in geosynchronous orbit. This study focuses on the 1.2-GW Abacus SSPS concept characterized by a 3.2 x 3.2 km solar-array platform, a 500-m diameter microwave beam transmitting antenna, and a 500 x 700 m earth-tracking reflector. For this baseline Abacus SSPS configuration, we derive and analyze a complete set of mathematical models, including external disturbances such as solar radiation pressure, microwave radiation, gravity-gradient torque, and other orbit perturbation effects. The proposed control systems architecture utilizes a minimum of 500 1-N electric thrusters to counter, simultaneously, the cyclic pitch gravity-gradient torque, the secular roll torque caused by an offset of the center-of-mass and center-of-pressure, the cyclic roll/yaw microwave radiation torque, and the solar radiation pressure force whose average value is about 60 N.

Wie, Bong↗