Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Trapped radiation experiment

Trapped radiation detector on Mariner IV space probe measurement of outer Van Allen belt - feasibility of detecting trapped radiation at Mars

MARINER IV SPACE PROBE↗

Space radiation studies

Instrument design and data analysis expertise was provided in support of several space radiation monitoring programs. The Verification of Flight Instrumentation (VFI) program at NASA included both the Active Radiation Detector (ARD) and the Nuclear Radiation Monitor (NRM). Design, partial fabrication, calibration and partial data analysis capability to the ARD program was provided, as well as detector head design and fabrication, software development and partial data analysis capability to the NRM program. The ARD flew on Spacelab-1 in 1983, performed flawlessly and was returned to MSFC after flight with unchanged calibration factors. The NRM, flown on Spacelab-2 in 1985, also performed without fault, not only recording the ambient gamma ray background on the Spacelab, but also recording radiation events of astrophysical significance.

Gregory, J. C.↗

A Satellite Borne Cadmium Sulfide Total Corpuscular Energy Detector

The properties of single crystals of cadmium sulfide as radiation detectors are described. It has been found possible to select crystals such that: (a) The ratio of increase of conductivity under irradiation to the rate of absorption of energy in the crystal is substantially independent of particle energy (over the examined ranges of 500 ev to 80 kev for electrons and 5 kev to 180 kev for protons) and of the magnitude of energy flux (over the range from.005 to 10 ergs/cm(sup 2 -sec); and (b) The above ration is substantially the same for protons, electrons, alpha particles, x-rays, and gamma-rays. For a driving voltage of 100 volts, typical crystal yield currents of 10(sup -7) to 10(sup- 6) amperes for each erg/cm(sup 2-sec) of energy absorbed by the crystal. The threshold of such crystal detectors (resulting from dark currents of the order of 10(sup 10 amp) is typically 10(sup -3) ergs/cm(sup 2- sec). For the selected crystals a response-temperature coefficient of -0.25% per degree centigrade is found for the temperature range -50 deg C to + 50 deg C. A description is given of a complete CdS total corpuscular energy detector for the study of geomagnetically trapped radiation by means of a satellite. The detector described has a dynamic range great than 10(sup 4), a solid angle of 10(exp -3) steradian, and a detection threshold of approximately 1 erg/cm(sup 2-sec-sterad). A similar detector employing a small magnet for the selective exclusion of electrons is also described. Noteworthy practical features of these detectors for satellite and space probe experiments are: (a) Use of bare crystals, without covering foils, in order to detect charged particles having energies as low as hundreds of electron volts. (b) Simplicity of electronic auxiliaries. (c) Compactness, lightweight and nechanical ruggedness. (d) Low electrical power requirements; and (e) Conversion of conduction current to the rate of a twostate relaxation oscillator in order to facilitate telemetric transmission of data. A pair of such detectors was flown as part of the s-46 satellite payload on March 23, 1960, but due to vehicular failure an orbit was not achieved and the operation of the CdS detectors was observed for only, six minutes of flight.

Freeman, John W.↗

Detector absorptivity measuring method and apparatus

A method and apparatus for measuring the absorptivity of a radiation detector by making the detector an integral part of a cavity radiometer are described. By substituting the detector for the surface of the cavity upon which the radiation first impinges a comparison is made between the quantity of radiation incident upon the detector and the quantity reflected from the detector. The difference between the two is a measurement of the amount of radiation absorbed by the detector.

Sheets, R. E.↗

SiC Charged Particle Telescope GRC Independent Research and Development (IRAD) Program End of Project Final Report

In an advancement over the state-of-the art, NASA Glenn Research Center (GRC) has developed a large area silicon carbide (SiC)-based charged particle telescope through an Independent Research and Development (IRAD) project. The telescope has been demonstrated to have improved noise characteristics and resolution than previous SiC detectors. This improvement will meet the challenges of compact multidirectional robust radiation detector systems to study a wide range of elementary particle mass and energies. In order to provide a complete understanding of how energetic processes internal and external to the solar system shape magnetospheres, atmospheres, and surfaces, in situ particle observations should include measurements of Solar Energetic Particles (SEP) and Galactic Cosmic Rays (GCR), along with solar wind and plasma. The potential temperature stability, tolerance to high radiation environments, and low noise characteristics expected in SiC-based detectors can have advantages over the state-of-the-art silicon detectors. These advantages will allow the detectors to be deployed in small compact systems on a variety of platforms, enabling compact structures for small satellite platforms with improved data quality.

Field and particle detectors↗

Proton Straggling in Thick Silicon Detectors

Straggling functions for protons in thick silicon radiation detectors are computed by Monte Carlo simulation. Mean energy loss is constrained by the silicon stopping power, providing higher straggling at low energy and probabilities for stopping within the detector volume. By matching the first four moments of simulated energy-loss distributions, straggling functions are approximated by a log-normal distribution that is accurate for Vavilov k is greater than or equal to 0:3. They are verified by comparison to experimental proton data from a charged particle telescope.

Selesnick, R. S.↗

Planetary-scan system

Mariner IV scanning system and radiation detector for locating and tracking Mars

MARINER IV SPACE PROBE↗

Photon bunching and the photon-noise-limited performance of infrared detectors

The photon-noise-limited performance of a radiation detector exposed to a thermal background of temperature T is analyzed by calculating the resulting specific detectivity. Both ideal photon detectors of arbitrary quantum efficiency eta and ideal thermal detectors of arbitrary emissivity eta are considered; and the effects of both shot noise and excess noise are taken into account. The relative contributions of these two sources depend on the quantum efficiency or emissivity of the system. For frequencies nu such that hnu/kT is much less than eta, excess noise can make an appreciable contribution to the total system noise. For the case of the detection of the narrow-band radiation, the specific detectivity is independent of eta in the limit hnu/kT is much less than eta.

Boyd, R. W.↗

Plural-wavelength flame detector that discriminates between direct and reflected radiation

A flame detector employs a plurality of wavelength selective radiation detectors and a digital signal processor programmed to analyze each of the detector signals, and determine whether radiation is received directly from a small flame source that warrants generation of an alarm. The processor's algorithm employs a normalized cross-correlation analysis of the detector signals to discriminate between radiation received directly from a flame and radiation received from a reflection of a flame to insure that reflections will not trigger an alarm. In addition, the algorithm employs a Fast Fourier Transform (FFT) frequency spectrum analysis of one of the detector signals to discriminate between flames of different sizes. In a specific application, the detector incorporates two infrared (IR) detectors and one ultraviolet (UV) detector for discriminating between a directly sensed small hydrogen flame, and reflections from a large hydrogen flame. The signals generated by each of the detectors are sampled and digitized for analysis by the digital signal processor, preferably 250 times a second. A sliding time window of approximately 30 seconds of detector data is created using FIFO memories.

Hall, Gregory H.↗

Radiation monitoring container device (16-IML-1)

In this experiment, layers of radiation detectors and biological specimens, bacterial spores (Bacillus subtillis), shrimp eggs (Altemia salina), and maize seeds (Zea mays) are sandwiched together in the Radiation Monitoring Container. The detectors, sheets of plastic materials, record the nuclear track of cosmic radiation. The dosimeter package contains conventional detectors made of materials such as lithium fluoride or magnesium-silica-terbium. The thermoluminescent materials (TLD) will, when moderately heated, emit luminescent photons linearly depending upon the dose of radiation received. The experiment, enclosed in a box-like container, is mounted on the aft end cone of the Spacelab, the area where the shielding is somewhat less than other locations.

Nagaoka, S.↗