Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIOACTIVE PARTICLE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Design and calibration of an optically segmented single volume scatter camera for neutron imaging

The Optically Segmented Single Volume Scatter Camera (OS-SVSC) aims to image neutron sources for non-proliferation applications using the kinematic reconstruction of elastic double-scatter events. Our prototype system consists of 64 EJ-204 organic plastic scintillator bars, each measuring 5mm × 5mm × 200mm and individually wrapped in Teflon tape. The scintillator array is optically coupled to two silicon photomultiplier ArrayJ-60035 64P-PCB arrays, each comprised of 64 individual 6x6mm J-Series sensors arranged in an 8 × 8 array. We report on the design details, including component selections, mechanical design and assembly, and the electronics system. The described design leveraged existing off-the-shelf solutions to support the rapid development of a phase 1 prototype. Several valuable lessons were learned from component and system testing, including those related to the detector's mechanical structure and electrical crosstalk that we conclude originates in the commercial photodetector arrays and the associated custom breakout cards. We detail our calibration efforts, beginning with calibrations for the electronics, based on the IRS3D application-specific integrated circuits, and their associated timing resolutions, ranging from 3090ps. With electronics calibrations applied, energy and position calibrations were performed for a set of edge bars using 22 Na and 90 Sr, respectively, reporting an average resolution of 12.07±0.03mm for energy depositions between 900keVee and 1000keVee. We further demonstrate a position calibration method for the internal bars of the matrix using cosmic-ray muons as an alternative to emission sources that cannot easily access these bars, with an average measured resolution of 14.86+-0.29mm for depositions between 900keVee and 1000keVee. The coincident time resolution reported between pairs of bars measured up to 400ps from muon acquisitions. Energy and position calibration values measured with muons are consistent with those obtained using particle emission sources.

47 OTHER INSTRUMENTATION↗

3 He +𝛼 resonances in 7 Be

Resonances in 7 Be which decay into the 3 He+α exit channel have been measured with improved precision using preexisting data sets. The energy and width of the J π =7/2 - state have been extracted from an invariant-mass study of projectile-breakup products originating from interactions of an E/A=10.7-MeV 10 C beam on Be and C targets. The excitation energy of this state (from the pole of the S-matrix) is determined to be E*=4.545(6)~MeV, a factor of 8 improvement in precision as compared to the ENSDF value. This improvement is enabled by fine tuning the detector calibrations using calibration resonances in 6 Li, 7 Li, 6 Be, 9 B, and 12 C whose decay energies are known to high precision. The J π =7/2- resonance in 7 Be can now itself be used as a calibration resonance in invariant-mass experiments. This utility is particularly helpful for 3 He energy calibrations of CsI(Tl) detectors which are often used in detector arrays employed for measurements with fast beams. This utility is demonstrated with a data set associated with E/A=70 MeV 7 Be beams which are inelastically excited to the 7/2 - and 5/2 - 1 resonances. Again using the pole of the S-matrix as the definition of the resonance parameters, the fitted excitation energy of the 5/2 - 1 resonance is 6.376(17) MeV, approximately 300 keV lower than the ENSDF value. Finally, its width of 565(4) keV is roughly half of the ENSDF value.

energy levels↗

Early Signal of Emerging Nuclear Collectivity in Neutron-Rich 129Sb

Radioactive 129Sb, which can be treated as a proton plus semimagic 128Sn core within the particle-core coupling scheme, was studied by Coulomb excitation. Reduced electric quadrupole transition probabilities, B(E2), for the 2+Ⓧπg7/2 multiplet members and candidate πd5/2 state were measured. The results indicate that the total electric quadrupole strength of 129Sb is a factor of 1.39(11) larger than the 128Sn core, which is in stark contrast to the expectations of the empirically successful particle-core coupling scheme. Shell-model calculations performed with two different sets of nucleon-nucleon interactions suggest that this enhanced collectivity is due to constructive quadrupole coherence in the wave functions stemming from the proton-neutron residual interactions, where adding one nucleon to a core near a double-shell closure can have a pronounced effect. The enhanced electric quadrupole strength is an early signal of the emerging nuclear collectivity that becomes dominant away from the shell closure.

Gray, Tim↗

Thermal Conductivity Measurements on Irradiated TRISO Fuel at IMCL

INL is leading the development and testing of accident tolerant fuels: fuels that resist melting down and that contain radioactive byproducts, preventing their release into their environment. One such fuel, called TRi-structural ISOtropic particle fuel (TRISO) See Fig 1. Understanding how heat propagates through a fuel is essential to fuel development and qualification. When irradiated in a reactor the properties that affect heat transport change. Our objective is to quantify the change in thermal properties of TRISO after irradiation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

TinyTPC: A Test Stand for LAr Doping

TinyTPC is a small scale liquid-argon time projection chamber (LArTPC) featuring a pixelated readout system (LArPix) designed to improve the detection of charged particles. To enhance energy measurements at MeV scales, TinyTPC will study the impact of isobutylene, a photosensitive dopant that converts light to charge, and xenon, a wavelength shifter. This presentation will detail TinyTPC's commissioning, operation, data collection methodologies, noise levels, and upcoming tests involving isobutylene, xenon, and radioactive sources.

43 PARTICLE ACCELERATORS↗

Investigating radioactive negative ion production via double electron capture

The relative cross sections for radioactive negative ion production via double electron capture have been measured for collisions between a 40 keV projectile beam of uranium-238 and potassium vapor. This was performed at the collinear resonance ionization spectroscopy (CRIS) experiment at CERN-ISOLDE and is a step towards measuring the electron affinities (EAs) of elements that cannot be efficiently produced in negative ion sources at radioactive ion beam (RIB) facilities. This includes short-lived radioactive isotopes that have low production quantities and heavy and superheavy elements that systematically have smaller EAs than work functions of available ion source materials. Negative ions are particularly sensitive to electron–electron correlation effects, which make such studies ideal for benchmarking atomic structure models that go beyond the independent particle model. While the EAs of most light elements have been measured, experimental investigations on heavier elements, namely the actinides, remain scarce due to their radioactive nature and production difficulty. By developing negative ion production by charge exchange, we aim to make these studies feasible at RIB facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Subject-specific modeling framework for particle deposition using computational fluid dynamics

Quantifying particle deposition and dose in the respiratory tract requires a physiologically realistic representation and reproducible computational workflows. However, existing modeling frameworks, such as the International Commission on Radiological Protection (ICRP) compartmental models and the Multiple Path Particle Dosimetry (MPPD) tool, lack detailed deposition profiles and subject-specific capabilities. The combination of advances in computer vision algorithms applied to the respiratory tract and Computational Fluid and Particle Dynamics (CFPD) allows high-fidelity simulations of particle behavior in anatomically accurate geometries derived from individual CT scans. The segmentation, preprocessing, and file preparation task for a CFPD simulation was often time-consuming, and no prior studies to-date have yet presented a fully automated framework. This work presents a fully automated workflow to obtain individualized particle deposition profiles in the human respiratory tract. The pipeline starts with segmenting upper and lower airway geometries using morphological and deep learning-based methods, generating three-dimensional (3D) models from CT imaging data. Next, a series of algorithms are presented to quality check and prepare the 3D geometry for a CFD or CFPD simulation. The preprocessing step includes correcting geometric artifacts, enforcing a physically consistent mesh, and automatically identifying and capping multiple outlets, which is required for CFD/CFPD simulations. These processed models are then input into open-source (OpenFOAM) or commercial (StarCCM+) CFD solvers, where flow and transient particle transport equations — including turbulence and particle–wall interactions are solved under realistic breathing conditions. Finally, the resulting particle deposition profiles can be integrated with Monte Carlo radiation transport codes and state-of-the-art computational phantoms to assess organ-specific absorbed doses in scenarios of radioactive aerosol inhalation. The presented work streamlines respiratory tract segmentation, preprocessing for CFD/CFPD simulations, and integration with dose assessment workflows, reducing manual intervention and improving access to high-fidelity, subject-specific modeling. The high precision in predicted particle deposition and dose distributions can improve personalized treatment strategies in respiratory medicine and refine dose estimates for radiation protection.

AI↗

A microfluidic electrochemical cell for studying the corrosion of uranium dioxide (UO 2 )

We have developed a specialized microfluidic electrochemical cell that enables in situ investigation of the electrochemical corrosion of microgram quantities of redox active solids. The advantage of downscaling is the reduction of hazards, waste, expense, and greatly expanding data collection for hazardous materials, including radioactive samples. Cyclic voltammetry was used to monitor the oxidation–reduction cycle of minute quantities of micron-size uraninite (UO 2 ) particles, from the formation of hexavalent uranium (U(VI)), U 3 O 7 and reduction to UO 2+x . Reaction progress was also studied in situ with scanning electron microscopy. The electrochemical measurements matched those obtained at the bulk-scale and were consistent with ex situ characterization of the run products by X-ray photoelectron spectroscopy, scanning transmission electron microscopy, and atomic force microscopy; thus, demonstrating the utility of the microfluidic approach for studying radioactive materials.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Amphiphilic Block Copolymers for Flocculation and Hydrophobization of Legacy Waste Suspensions in Flotation Driven Dewatering Operations - 20162

Flotation has been effectively demonstrated as a low footprint, high efficiency separation process when utilising simple anionic surface modifying agents such as sodium dodecyl sulphate (SDS). These agents increase hydrophobicity to remove suspended cationic surface charged particulates such as Mg(OH){sub 2} from waste suspensions similar to those at British nuclear fuel management sites- where corrosion processes have degraded fuel cladding. The technology is advantageous as it could effectively be retrofitted into existing waste management facilities at nuclear waste management sites such Sellafield and Hanford as the simplicity (no moving parts) and size of this technology coupled with low cost of construction could be rapidly deployed to aid in risk and hazard reduction decommissioning operations with minimum impact to secondary waste generation. Previously, sodium dodecyl sulphate has been deployed as a collector agent to increase the hydrophobicity of Mg(OH){sub 2} suspended particles, achieving a maximum particulate extraction percentage of 93%. To achieve further particulate extraction, flotation performance has been determined to be a function of the hydrodynamic limitations extracting fine material (>20 μm). Fine particulates have been shown in the minerals industry to have an inability to overcome slipstreams created from rising bubbles in flotation cells, likely due to the low mass and thus momentum of the colloidal material, preventing interaction between the hydrophobized particles and air-water interfaces (bubbles). To combat this mass transfer resistance poly(acrylic acid)-block-poly(n-butyl acrylate) amphiphilic diblock copolymers were synthesised via reversible addition-fragmentation chain-transfer (RAFT) polymerisation. The anticipated mode of action of these polymers involves the hydrophilic poly(acrylic acid) block polymer acting as a flocculation agent to increase the mass of the aggregates, and the hydrophobic poly(n-butyl acrylate) modifies the hydrophobicity of the resulting flocs. The concentration of this polymer (termed a macro-collector) was varied and the change in particle size distribution of the particulate suspension was analysed using static light scattering. The flotation performance was then characterised by several methods including percentage particulate recovery, volume reduction factor and residual bulk particulate concentration. This was then benchmarked against the traditional surfactant collector agent SDS. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Charged particle track reconstruction with SπRIT Time Projection Chamber

In this work, we present a software framework, SπRITROOT, which is capable of track reconstruction and analysis of heavy-ion collision events recorded with the SRIT time projection chamber. The track-fitting toolkit GENFIT and the vertex reconstruction toolkit RAVE are applied to a box-type detector system. A pattern recognition algorithm which performs helix track finding and handles overlapping pulses is described. The performance of the software is investigated using experimental data obtained at the Radioactive Isotope Beam Facility (RIBF) at RIKEN. This work focuses on data from 132 Sn + 124 Sn collision events with beam energy of 270 AMeV. Particle identification is established using < dE/dx >and magnetic rigidity, with pions, hydrogen isotopes, and helium isotopes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High temperature and high beam current compatible targets and methods thereof for generating noble gas/radiohalogen generators for medical isotopes

A method of providing alpha particle emitters and materials suitable for use in generating the alpha particles for medical treatment is disclosed. Metal oxide targets, preferentially Bi 2 O 3 pellets and Bi 2 O 3 coatings on metallic or metal oxide substrates are formed. The targets placed in a heated vacuum chamber subjecting to irradiation using a 6 Li beam at an elevated temperature below the melting point of the target generate a radioactive gas, such as 211 Rn, the radioactive gas is carried by an inert gas which is delivered a carrier for, such as a carbon column or oil for delivery to a treatment facility. The radioactive gas such as 211 Rn generates 211 At, which has a useable half-life of at least about 14 hours, in turn releases alpha particles which are effective for use in medical procedures.

Sampathkumaran, Uma↗

Tritium targets for use in solenoidal spectrometers

Nucleon adding and removing reactions are an ideal probe to study the single-particle foundations of nuclear structure. For experiments far away from the valley of stability, one needs to use radioactive beams in inverse kinematics. To maintain excellent resolution, solenoidal spectrometers like HELIOS at Argonne National Laboratory (ANL), ISS at CERN or SOLARIS at the Facility for Rare Isotope Beams (FRIB) are used. Typically, deuterated plastic foils are the targets of choice. Depending on the energy deposited, these targets might degrade quickly in beam. The potential of using tritium-implanted targets in conjunction with the solenoidal spectrometers was realized for access to even more exotic nuclei with outstanding resolving power. While no tritiated polyethylene is commercially available at the moment, tritium-containing titanium targets have been produced in the past. Unfortunately the loading fraction of tritium for the latter was often very low and not reproducible. The progress in the production of tritium-containing targets is presented, including the characterization of the foils.

Müller-Gatermann, Claus↗

Gallium oxide semiconductor-based large volume ultrafast radiation hard spectroscopic scintillators

We report on the development of the first-ever inorganic radiation-hard moisture-insensitive large volume spectroscopic semiconductor-based scintillator with less than 2 ns decay time and light yields as high as 8000 ph/MeV. Despite extensive research into scintillator materials, the quest for an ideal scintillator combining ultrafast decay times (akin to BaF 2 and Yb-doped scintillators such as Lu 2 O 3 :Yb), high light yields (exceeding 2000 photons per MeV), spectroscopic capabilities, and exceptional radiation hardness remain unfulfilled. In this study, we demonstrate and report for the first time the viability of large-volume (up to 20 mm thickness) gallium oxide (β-Ga 2 O 3 ) semiconductor-based scintillators for applications requiring these properties. These β-Ga 2 O 3 scintillators were grown using the fast turnaround (~2 days) crucible-free optical float zone (FZ) technique. The high light yield and ultrafast decay time of these high-purity n-type semiconductors with free carrier concentration of 6 × 10 17 cm –3 are attributed to native defects, specifically oxygen vacancies (V O ) and gallium–oxygen vacancy pairs (V Ga –V O ), generated during optimized FZ growth. The ultrafast decay, along with high light yield, enables excellent timing resolution and high count rate detection for applications like time-of-flight positron emission tomography, physics experiments, and nuclear safety. The radiation hardness of these devices has been documented in a separate publication.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effective field theory interactions for liquid argon target in DarkSide-50 experiment

We reanalize data collected with the DarkSide-50 experiment and recently used to set limits on the spin-independent interaction rate of weakly interacting massive particles (WIMPs) on argon nuclei with an effective field theory framework. The dataset corresponds to a total (16660 ± 270) kg d exposure using a target of low-radioactivity argon extracted from underground sources. We obtain upper limits on the effective couplings of the 12 leading operators in the nonrelativistic systematic expansion. For each effective coupling we set constraints on WIMP-nucleon cross sections, setting upper limits between 2.4×10-45 cm2 and 2.3×10-42 cm2 (8.9 ×10-45 cm2 and 6.0 ×10-42 cm2) for WIMPs of mass of 100 GeV/c2 (1000 GeV/c2) at 90% confidence level.

Agnes, P↗

Boson Fermion Nucleus Explanation for Violation of Parity in the Radioactive Decay of Cobalt-60: Monograph #12

In 1957, Chien-Shuing Wu subjected cobalt-60 to supercooled temperatures and a strong magnetic field while measuring radioactive decay. This experiment showed violation of parity— a long-held, fundamental precept in physics stating that nuclear radioactive-decay emission flux will not vary in the solid angle about the nucleus. During Wu’s experiment, beta particles (electrons) exhibited asymmetry, preferentially exiting the cobalt-60 nuclei in the polar region opposite the applied magnetic field. Gamma-ray emissions were anisotropic, preferring to exit the nucleus around the equatorial region. The boson fermion nucleus (BFN) explains the origins of these observed phenomena, where the nuclear structure is pinned in the strong magnetic field with minimal motion in supercooled conditions, while beta particles and gamma rays are emitted from specific locations within the nuclear structure.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Surrogate isotope-containing materials for emergency response training and Methods of formation and dispersal

Surrogate materials are in the form of solid particles that include surrogate isotopes, namely, short-lived isotopes selected and formed to serve as surrogates for the radioactive materials of a nuclear fallout without including isotopes that are, or that decay to, biologically or environmentally deleterious and persistent isotopes. The surrogate material may be formed using high-purity reactant material and irradiation and separation techniques that enable tailoring of the isotopes and ratios thereof included in the surrogate material, and the surrogate material may be dispersed, e.g., in a training environment, in solid form.

Carney, Kevin P.↗

Morphological Characterization of Uranyl Fluoride Particles via Atomic Force Microscopy

Uranium hexafluoride (UF 6 ) undergoes a rapid hydrolysis reaction when exposed to atmospheric water. In addition to producing hazardous HF gas, the hydrolysis reaction produces uranyl fluoride (UO 2 F 2 ), a radioactive solid phase particulate material. Because of the technological utility of UF 6 in the nuclear fuel cycle, understanding the transport properties of UO 2 F 2 aerosol produced via UF 6 hydrolysis is important for accident scenarios. Moreover, the fundamental chemical and physical properties of the UF 6 hydrolysis reaction are not completely understood. Recently, several experiments on the aerosol phase properties of UO 2 F 2 produced in this way have shown that under most relevant conditions, the particle size distribution (PSD) of UO 2 F 2 can be extremely small, approximately 3 to 5 nm, which is well below the threshold that can be routinely observed via scanning electron microscopy (SEM). Although readily observable in the aerosol phase, observation of nanometer-sized particles in the condensed phase (i.e. deposited on surfaces) remains a challenge. Here, in this study, we have used atomic force microscopy (AFM) to study the PSD and morphological characteristics of UO 2 F 2 deposited at low and high concentrations under different humidity conditions, a primary variable in the hydrolysis reaction. Here, we find strong agreement between PSD measured in the aerosol phase via scanning mobility particle sizing and PSD measured via AFM, with particle sizes peaked below 4 nm for low-humidity conditions. At higher humidity, the distribution is centered around 5 to 10 nm but extends up to 20 nm. These results are in stark contrast to previous measurements using SEM that show PSD on the order of 300- to 1000-nm particle sizes; moreover, these are the first direct measurements of individual particles of UO 2 F 2 having been produced via UF 6 hydrolysis deposited on surfaces. These measurements, therefore, open a new avenue for collecting and detecting UO 2 F 2 in the condensed phase and further refine the PSD, which is critical for environmental transport determinations.

Uranium hexafluoride↗

Efficient Mesofluidic Separation of Large Particles in nuclear slurries - 20408

Efficient and effective particle separation is essential to cleanup of many nuclear wastes. For example, particle separation may be used to accelerate settle-decant bottlenecks that limit the throughput necessary to achieve the U.S. Department of Energy waste cleanup mission in a timely manner. Particle separation may be used to protect downstream processing equipment from pulses of solids that may be encountered near (within a few feet of) liquid-solid interfaces during waste transfer operations, thereby preventing work stoppages. Effective particle separation may permit efficient sludge washing. These are only a few of the ways in which particle separation is important. Yet, efficient and effective particle separation in nuclear processing environments remains challenging. For example, settle-decant operations permit larger and heavier particles to settle, leaving smaller, lighter particles suspended. However, settle-decant operations are slow, convection currents may resuspend solids, hindered settling of multicomponent slurries remains incompletely understood, and predictive models for settling in graduated cylinders fail to match limited observations of settling in large waste tanks. Additionally, pumping operations can cause turbulent resuspension of particles when the pump intake is close to the settled solids layer. Filtration techniques that use membranes or partially permeable barriers retain larger particles, permitting smaller particles to permeate. However, filters, including dead-end filtration, are prone to clogging and caking, operate at elevated pressures due to minimal void volume, and increase in pressure during operations, which require more control systems. Therefore, the need for high throughput particle separation techniques that operate with modest pressure drops persists. A novel mesofluidic separator presents the opportunity to effectively and efficiently accelerate the waste cleanup mission. The separator separates large particles from process streams across a broad range of particle sizes and has no moving parts or media to replace, regenerate, or clean. This separator design has an unusually large void volume, permitting operation at much higher flow rates (and lower pressures) than traditional filtration (e.g., dead-end filtration). Industrial-scale flow rates have been demonstrated. In performance testing, mesofluidic separators operate at might flow rates (>90 gpm (0.0006 m{sup 3}/s) in piping 3 inches (0.08 m) in diameter; Re>10{sup 5}), with modest pressure drop (∼25 psi (170 KPa) in testing). In complex, aggregating waste simulants, the separator loses <25% of flow projected over months without back pulsing or chemical cleaning. Mesofluidic separation presents infrastructure advantages, reduces risk, and provides mission impact. Infrastructure advantages include implementation within existing transfer systems, plug and play without facility modifications to safety systems, and operation at low pressures. The separator is flexible in location, may be positioned within or outside of waste tanks, and may replace or augment dead-end and cross-flow filters. Mesofluidic separation reduces risk by minimizing waste (no media to replace or regenerate and no cleaning chemicals to handle and dispose) and by minimizing filter change-out consistent with as low as reasonably achievable (ALARA) exposure to workers. The potential mission impact of these separators is substantial. The separator has potential to support, simplify, and accelerate in-farm transfers and waste feed delivery. Furthermore, the separator can free up settling and holding tanks in the Direct Feed Low-Activity Waste (DFLAW) mission by reducing or eliminating post-transfer settling and wait times with the potential to free up 1 Mgal (4000 m{sup 3}) of double-shell tank space. This paper quantitatively compares mesofluidic separation to dead-end filtration, discusses scale-up results, and considers the separator's potential to efficiently and effectively reduce the long-term environmental ability of particulate-rich nuclear wastes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗