Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIOACTIVE SOURCES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Study of Plastic Scintillator Properties for Radioactive Sources Dosimetry - Paper 108

Plastic scintillator is a simple material which has the density close to that of human soft tissue (1.06 g/cm{sup 3}). Its energy response is close to that of human soft tissue and it is relatively energy independent. This prospect provide a desired characteristics in measuring dose by plastic scintillator either for radiation monitoring or personal dosimeter. Generally the energy calibration of organic scintillator will be done by using gamma ray sources. The positions of Compton edge in pulse height spectra, which have known energy values will be identified. However the Compton edge normally is very broad and difficult to determine the point corresponding to that particular Compton electron energies. Many researchers used several fitting functions and Monte Carlo simulations to determine the position of Compton edge. For example, Proctor and Wellman (2012) used a straight line fit to the linear part of Compton edge and extrapolated to zero count. While L. Swiderski et al. used a method based on a back-scattered coincidence measurement to measure in a wide energy range the position of Compton edge in organic scintillators. For a simple and quick approach of calibration, we used a Gauss-error function to fit the Compton edge region of interest by assumed that the location of maximum energy of Compton electrons is half-height of the Compton maximum (CM). The reasons is because the CM position could be determined easily from the spectra throughout wide energy range. Interpreting gamma dose rates from accumulated plastic scintillation detector spectra is often a complex task because the probability of a full energy deposition event in the detector is often negligible. Despite no full energy peaks in plastic scintillator spectra, several attempts have been made by the other researchers to obtain the dose from the energy distribution spectra of gamma radiation. For example, Proctor and Wellman used the modified spectrum dose index (SDI) to calculate the exposure rates by multiplying the energy corresponding to its channel and all products are summed before multiply by a calibration constant to yield an exposure rate. While Lobdell and Hertel calculated dose using a response matrix based on spectral unfolding technique. From these points of view, we have made an attempt to correlate the counts obtained in scintillator with absorbed dose or ambient dose equivalent. We aimed to calibrate the plastic scintillator energy deposition for dose, by correlate the counts obtained with a particular value of dose. By designed the scintillator to measure at 1 cm tissue depth might be helpful to be used as radiation monitoring or personal dosimeter since the energy response of plastic scintillator is relatively energy independent compared to that of inorganic scintillators. The energy calibration proposed from simple fitting approach had been verified with calculated spectra. This might be considered as a practical approach for technician or radiation workers with sufficient accuracy. The linear behavior of counts per absorbed dose give promising to calibrate scintillator energy deposition to read dose (equivalent dose or absorbed dose) for photons. Thus the scintillator could provide both the energy and dose response simultaneously, which may important in some radiation field of measurements. Currently the scintillator is able to give dose rate value for gamma sources of Cs-137 and Mn-54. The number of counts per unit absorbed dose would likely to vary somewhat with photon energy, although the plastic scintillator should have a tissue dose response that is relatively energy independent. Further analysis will be done on conversion factor parameters so that it could be used in such situations where the radiation field is complex or unknown. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Response of the REWARD detection system to the presence of a Radiological Dispersal Device

In recent years an increased international concern has emerged about the radiological and nuclear (RN) threats associated with the illicit trafficking of nuclear and radioactive materials that could be potentially used for terrorist attacks. The objective of the REWARD (Real Time Wide Area Radiation Surveillance System) project, co-funded by the European Union 7. Framework Programme Security, consisted in building a mobile system for real time, wide area radiation surveillance, using a CdZnTe detector for gamma radiation and a neutron detector based on novel silicon technologies. The sensing unit includes a GPS system and a wireless communication interface to send the data remotely to a monitoring base station, where it will be analyzed in real time and correlated with historical data from the tag location, in order to generate an alarm when an abnormal situation is detected. Due to its portability and accuracy, the system will be extremely useful in many different scenarios such as nuclear terrorism, lost radioactive sources, radioactive contamination or nuclear accidents. This paper shortly introduces the REWARD detection system, depicts some terrorist threat scenarios involving radioactive sources and special nuclear materials and summarizes the simulation work undertaken during the past three years in the framework of the REWARD project. The main objective consisted in making predictions regarding the behavior of the REWARD system in the presence of a Radiological Dispersion Device (RDD), one of the reference scenarios foreseen for REWARD, using the Monte Carlo simulation program MCNP6. The reference scenario is characterized in detail, from the i) radiological protection, ii) radiation detection requirements and iii) communications points of view. Experimental tests were performed at the Fire Brigades Facilities in Rome and at the Naples Fire Brigades, and the results, which validate the simulation work, are presented and analyzed. The response of the REWARD detection system to the presence of an RDD is predicted and discussed. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Safe and Secure Management of Disused Radioactive Sealed Sources in Egypt - 19063

Radioactive sources offer many benefits in medicine, industry and education but the lack of appropriate long-term management when they eventually become disused has led to accidents, in some cases with serious consequences, and increased their vulnerability for use in a malicious act. This lack is evident in the absence of clearly defined policy and strategy, responsibilities and resources to meet those responsibilities for safe, secure and sustainable management of disused sources. The strengthening of national legislative and regulatory infrastructures globally has led to major improvements in the protection and control of radioactive sources. Nevertheless, in many countries, radioactive sources were in use before such infrastructures had been developed or adequately strengthened and were therefore not under regulatory control. The paper presents some aspects from Egyptian experience related to safe and secure measures for management of Cs-137, Ra-226 and Co-60 sealed sources. Data relating to the disused radioactive sealed sources, DSRS inventory as well as the arrangements made in order to prepare for conditioning of sources is presented. The efforts made by technical staff and radiation protection team for all arrangements and details such as conditioning set-up, working area, leakage test, certified stainless capsules, radiation protection measures and sources characterization in addition to all security measures for stored DSRS are also presented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radiological Risk From Disused Radioactive Sealed Sources in Egypt - 19083

Sealed sources are radioactive nuclear substances encased in a sealed capsule or in a cover to which the substance is bonded, and are used for a variety of activities, such as medical, industrial, academic and research, as well as commercial applications. While most sources are of relatively low activity, there are many of medium or very high activity. In use radioactive sealed sources after time become disused sources according to several reasons like, if the source activity became less than the desired activity (unfit for the intended application), if the model of the instrument became old fashion and no longer uses, if the source had been damaged, and if the user company was shut down and no longer in business. In developing countries, thousands of radium needles, teletherapy sources, oil well logging neutron sources, and miscellaneous industrial radioactive gauges are annually collected as waste and stored in centralized waste facilities. Although these sources become disused, it still dangerous and the mismanagement of high activity sources is responsible for most of the radiological accidents that result in loss of life or disabling injuries. On the other hand, these sources may be a target for criminal acts in countries where final disposal options are unavailable. Egyptian Atomic Energy Authority (EAEA) represented in Hot Labs and Waste Management Center (HLWMC) is responsible by the national nuclear law (law No. 7 /2010) for management of all kinds of radioactive waste including disused radioactive sealed sources from all Egyptian territories. Categorization of disused sources is necessary to ensure that the controls and security measures that are applied to the sources are adequate with its radiological risk. The aim of this work is to use the international Atomic Energy Agency (IAEA) categorization system to provide a simple, logical system for grading disused radioactive sealed sources in Egypt as well as to update the inventory of such sources which already collected as waste in Egypt. The categorizations of radioactive sealed sources are based on their potential to cause harm to human health. This study revealed that nearly 980 sources have been defined in Egypt as disused sources with a total activity of 46100 Ci according to available data in July 2018. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Global threat reduction initiative efforts to address transportation challenges associated with the recovery of disused radioactive sealed sources - 10460

Proper disposition of disused radioactive sources is essential for their safe and secure management and necessary to preclude their use in malicious activities. Without affordable, timely transportation options, disused sealed sources remain in storage at hundreds of sites throughout the country and around the world. While secure storage is a temporary measure, the longer sources remain disused or unwanted the chances increase that they will become unsecured or abandoned. The Global Threat Reduction Initiative's Off-Site Source Recovery Project (GTRIlOSRP), recovers thousands of disused and unwanted sealed sources annually as part of GTRl's larger mission to reduce and protect high risk nuclear and radiological materials located at civilian sites worldwide. Faced with decreasing availability of certified transportation containers to support movement of disused and unwanted neutron- and beta/gamma-emitting radioactive sealed sources, GTRIlOSRP has initiated actions to ensure the continued success of the project in timely recovery and management of sealed radioactive sources. Efforts described in this paper to enhance transportation capabilities include: {sm_bullet} Addition of authorized content to existing and planned Type B containers to support the movement of non-special form and other Type B-quantity sealed sources; {sm_bullet} Procurement of vendor services for the design, development, testing and certification of a new Type B container to support transportation of irradiators, teletherapy heads or sources removed from these devices using remote handling capabilities such as the IAEA portable hot cell facility; {sm_bullet} Expansion of shielded Type A container inventory for transportation of gamma-emitting sources in activity ranges requiring use of shielding for conformity with transportation requirements; {sm_bullet} Approval of the S300 Type A fissile container for transport of Pu-239 sealed sources internationally; {sm_bullet} Technology transfer of field-sealable (non-welded) special form capsules for commercial use.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RCT: Module 2.08, Radiological Source Control, Course 8774

radioactive source is material used for its emitted radiation. Sources are sealed or unsealed and are classified as accountable or exempt. Radioactive sources are used for response checks, functional checks, and the calibration of instruments and monitors to traceable standards. To ensure the safety and welfare of all personnel, it is important to maintain control of radioactive sources to minimize the potential for the spread of contamination, unnecessary exposure to personnel, loss or theft, and improper disposal. This course will prepare the student with the skills necessary for RCT qualification by passing quizzes, tests, and the RCT Comprehensive Phase 1, Unit 2 Examination (TEST 27566) and will provide in-the-field skills.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Dynamic radioactive particle source

A method and apparatus for providing a timed, synchronized dynamic alpha or beta particle source for testing the response of continuous air monitors (CAMs) for airborne alpha or beta emitters is provided. The method includes providing a radioactive source; placing the radioactive source inside the detection volume of a CAM; and introducing an alpha or beta-emitting isotope while the CAM is in a normal functioning mode.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A gas-jet transport and catcher technique for on-line production of radioactive ion beams using an electron cyclotron resonance ion-source

Radioactive ion beams (RIB) have been produced on-line, using a gas-jet recoil transport coupled Electron Cyclotron Resonance (ECR) ion-source at the VECC-RIB facility. Radioactive atoms/molecules carried through the gas-jet were stopped in a catcher placed inside the ECR plasma chamber. A skimmer has been used to remove bulk of the carrier gas at the ECR entrance. The diffusion of atoms/molecules through the catcher has been verified off-line using stable isotopes and on-line through transmission of radioactive reaction products. Beams of {sup 14}O (71 s), {sup 42}K (12.4 h), {sup 43}K (22.2 h), and {sup 41}Ar (1.8 h) have been produced by bombarding nitrogen and argon gas targets with proton and alpha particle beams from the K130 cyclotron at VECC. Typical measured intensity of RIB at the separator focal plane is found to be a few times 10{sup 3} particles per second (pps). About 3.2 Multiplication-Sign 10{sup 3} pps of 1.4 MeV {sup 14}O RIB has been measured after acceleration through a radiofrequency quadrupole linac. The details of the gas-jet coupled ECR ion-source and RIB production experiments are presented along with the plans for the future.

43 PARTICLE ACCELERATORS↗

Extraction simulations and emittance measurements of a Holifield Radioactive Ion Beam Facility electron beam plasma source for radioactive ion beams

The Holifield Radioactive Ion Beam Facility (HRIBF) at Oak Ridge National Laboratory has a variety of ion sources used to produce radioactive ion beams (RIBs). Of these, the workhorse is an electron beam plasma (EBP) ion source. The recent addition of a second RIB injector, the Injector for Radioactive Ion Species 2 (IRIS2), for the HRIBF tandem accelerator prompted new studies of the optics of the beam extraction from the EBP source. The source was modeled using SIMION V8.0, and results will be presented, including comparison of the emittances as predicted by simulation and as measured at the HRIBF offline ion source test facilities. Also presented will be the impact on phase space shape resulting from extraction optics modifications implemented at IRIS2.

43 PARTICLE ACCELERATORS↗

Extraction simulations and emittance measurements of a Holifield Radioactive Ion Beam Facility electron beam plasma source for radioactive ion beams

The Holifield Radioactive Ion Beam Facility HRIBF at Oak Ridge National Laboratory has a variety of ion sources used to produce radioactive ion beams RIBs. Of these, the workhorse is an electron beam plasma EBP ion source. The recent addition of a second RIB injector, the Injector for Radioactive Ion Species 2 IRIS2, for the HRIBF tandem accelerator prompted new studies of the optics of the beam extraction from the EBP source. The source was modeled using SIMION V8.0, and results will be presented, including comparison of the emittances as predicted by simulation and as measured at the HRIBF offline ion source test facilities. Also presented will be the impact on phase space shape resulting from extraction optics modifications implemented at IRIS2.

43 PARTICLE ACCELERATORS↗

Extraction Simulations and Emittance Measurements of a Holifield Radioactive Ion Beam Facility Electron Beam Plasma Source for Radioactive Ion Beams

The Holifield Radioactive Ion Beam Facility (HRIBF) at Oak Ridge National Laboratory has a variety of ion sources used to produce radioactive ion beams (RIBs). Of these, the workhorse is an electron beam plasma (EBP) ion source. The recent addition of a second RIB injector, the Injector for Radioactive Ion Species 2 (IRIS2), for the HRIBF tandem accelerator prompted new studies of the optics of the beam extraction from the EBP source. The source was modeled using SIMION V8.0, and results will be presented, including comparison of the emittances as predicted by simulation and as measured at the HRIBF offline ion source test facilities. Also presented will be the impact on phase space shape resulting from extraction optics modifications implemented at IRIS2.

Liu, Yuan↗

Hydrogen Transport in a Model 9979 Shipping Package with Inner Convenience Cans

Radiolytic hydrogen production and accumulation inside containment packages is a concern at any facility responsible for their packaging, storage, transportation, and/or disposal. When hydrogen gas accumulates to concentrations above the Lower Flammability Limit (LFL) which is 4% or 40,000 ppm in air, the possibility of a deflagration or explosion increases. This concern persists over the course of the package lifetime which is unlimited when disposed of by burial or in permanent repositories. Here, we report on a numerical model used to predict the concentration of hydrogen within each layer of a Model 9979 package containing a convenience can assembly. Simulations show the hydrogen concentration to always be highest in the inner convenience can containing the radioactive source. When the radioactive source is within the Los Alamos National Laboratory (LANL) Packaging Limits, the hydrogen concentration is shown to remain well below the LFL at all times including packaging, storage, transportation, and disposal. A hydrogen transport model is presented for a Model 9979 package system containing a nested arrangement of convenience cans, which are tin oxide coated steel cans of various sizes with a slip-lid assembly. The inner convenience can contains the radioactive source material along with an unknown quantity of incidental water acquired from humid air or processing. While visible organic materials such as paper and plastics were purposely excluded from the inner can, it is not possible to claim the wastes are entirely organic free. The inner convenience can is tape sealed and placed into a plastic bag which is horsetail closed (i.e., twisted and taped). The bagged can is placed into an outer convenience can that is also tape sealed. The can assembly is then placed into the 30 gallon drum and subsequently placed inside the 55 gallon drum in the 9979 package. Here we assume hydrogen gas is produced in the inner convenience can from alpha radiolysis of water at a rate dependent on the quantity of uranium isotopes and water present. The hydrogen transport model was used to calculate hydrogen accumulations within the package’s five layers at different times and conditions. These simulations serve two purposes; (i) to build confidence in the model by comparing predicted values to measured values, and (ii) to check the steady state hydrogen concentrations that are approached at long times in the package’s lifetime. Model simulations were compared to gas samples taken from the 30 gallon drum after storage at LANL’s Chemistry and Metallurgy Research (CMR) building for around 500 days. Hydrogen concentration calculations over much longer periods (i.e., more than 270 years) included extreme storage durations, transportation at extreme cold temperatures, and disposal of packages assuming different average temperatures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of Anodized and Electroplated Radioactive Check Sources for Radiological Monitoring Instruments

Radioactive check sources are often used for source checking calibrated instruments to confirm accurate readings are obtained from radiological monitoring instruments. Because of the importance of check sources and their application, PNNL conducted a study to evaluate the effectiveness and accuracy of active sources produced using different construction methods. Eleven, randomly selected check sources of both anodized (five) and electroplated (six) construction were evaluated, along with their calculated decay curves, to determine how well they withstand consistent, multi-year use in the field. Results show that the anodized and electroplated check sources evaluated hold up well enough to continue their use, regardless of wear and tear sustained over years of use. This report provides the source information, empirical data for the 11 anodized and electroplated check sources and their representative decay curves, and it documents the conclusion that anodized and electroplated check sources are reliable for routine use in the field over multiple years.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast pulsed operation of a small non-radioactive electron source with continuous emission current control

Non-radioactive electron sources are of great interest in any application requiring the emission of electrons at atmospheric pressure, as they offer better control over emission parameters than radioactive electron sources and are not subject to legal restrictions. Recently, we published a simple electron source consisting only of a vacuum housing, a filament, and a single control grid. In this paper, we present improved control electronics that utilize this control grid in order to focus and defocus the electron beam, thus pulsing the electron emission at atmospheric pressure. This allows short emission pulses and excellent stability of the emitted electron current due to continuous control, both during pulsed and continuous operations. As an application example, this electron source is coupled to an ion mobility spectrometer. Here, the pulsed electron source allows experiments on gas phase ion chemistry (e.g., ion generation and recombination kinetics) and can even remove the need for a traditional ion shutter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser ion sources for radioactive beams (invited)

Resonant ionisation laser ion sources are nowadays extensively used, when available, at many leading on-line facilities. Moreover, new laser ion sources are now under development in most of the recent on-line facility projects under construction worldwide. This success is mainly due to the reliability, the ionization efficiency and the high purity that this type of source can achieve for the production of radioactive species and for a large range of chemical elements. Laser ion sources for radioactive beams gather many different systems such as dye laser or all-solid state titanium:sapphire laser systems, high or low repetition rates, hot cavities or gas cells, additional selectivity by using chemical techniques, or the LIST technique (laser ion source trap). In this paper, the physics of laser ion sources will be described with the current limitations and challenges for the future. An overview of the laser ion source facilities will be given, with an emphasis on the ongoing developments and perspectives on LIS.

43 PARTICLE ACCELERATORS↗