Search NASA⌕ Search

SEARCH · Search NASA

Results for “READOUT SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Detecting Axion Dark Matter with Superconducting Qubits

Axion dark matter haloscopes aim to detect dark matter axions converting to single photons in resonant cavities bathed in a uniform magnetic field. A qubit (two level system) operating as a single microwave photon detector is a viable readout system for such detectors and may offer advantages over the quantum limited amplifiers currently used. When weakly coupled to the detection cavity, the qubit transition frequency is shifted by an amount proportional to the cavity photon number. Through spectroscopy of the qubit, the frequency shift is measured and the cavity occupation number is extracted. At low enough temperatures, this would allow sensitivities exceeding that of the standard quantum limit.

Dixit, Akash↗

The development and test of ultra-large-format multi-anode microchannel array detector systems

The specific tasks that were accomplished with each of the key elements of the multi-anode microchannel array detector system are described. The modes of operation of position-sensitive electronic readout systems for use with high-gain microchannel plates are described and their performance characteristics compared and contrasted. Multi-anode microchannel array detector systems with formats as large as 256 x 1024 pixels are currently under evaluation. Preliminary performance data for sealed ultraviolet and visible-light detector tubes show that the detector systems have unique characteristics which make them complementary to photoconductive array detectors, such as CCDs, and superior to alternative pulse-counting detector systems employing high-gain MCPs.

Timothy, J. G.↗

A Flexible Field Mapping System for Accelerator Magnets

Magnetic field mapping is a fundamental magnetic measurement method that typically uses Hall and NMR sensors. In magnet measurement facilities, such systems are likely used in various configurations suitable for a specific task at hand. To address this diversity, the authors developed a flexible field mapping system capable of being configured and tailored to each particular measurement case. Further, the system needs to address the variability introduced by differences in sensors and their readout systems, probe positioning systems, power supply systems, and required mapping geometry (mapping space and grid, measurement steps and sequences). Although the discussed field mapping systems range from a self-propelled multi-sensor mapper of a large detector magnet to a single 3D Hall sensor system to scan a small permanent magnet, they were all built with the same core mapping system. The variability present in field mapping systems, the measurement system architecture addressing this variability, as well as examples of several field mapping systems built in this architecture are presented.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Flexible Field Mapping System for Accelerator Magnets

Magnetic field mapping is a fundamental magnetic measurement method that typically uses Hall and NMR sensors. In magnet measurement facilities, such systems are likely used in various configurations suitable for a specific task at hand. To address this diversity, the authors developed a flexible field mapping system capable of being configured and tailored to each particular measurement case. The system needs to address the variability introduced by differences in sensors and their readout systems, probe positioning systems, power supply systems and in required mapping geometry (mapping space and grid, measurement steps and sequences). Although the discussed field mapping systems range from a self-propelled, multi-sensor mapper of a large detector magnet to a single 3D Hall sensor system to scan a small permanent magnet, they were all built with the same core mapping system. The variability present in field mapping systems and the measurement system architecture addressing this variability, as well as examples of several field mapping systems built in this architecture are presented.

43 PARTICLE ACCELERATORS↗

Toward Large Field-of-view X-ray Spectrometers with Magnetic Microcalorimeters

A future X-ray telescope mission like Lynx, a X-ray flagship mission concept, requires a large field of view, high energy resolution, and high spatial resolution. The Magnetic Microcalorimeter (MMC) detectors we are developing for such a mission feature a 5-arcminute field of view, approximately 100,000 pixels, each spanning 0.5–1 arcsecond. These detectors require the readout of 8,000 sensors. Three different array types have been designed to meet scientific goals, two of which utilize thermal multiplexing to reduce the number of readout channels in a scheme called “Hydra.” We are currently fabricating detectors on a recently completed buried wiring wafer with connections to every sensor. The sensors are read out using a microwave multiplexer (μMUX) with flux ramp modulation. A single μMUX can read out approximately 1,000 sensors with only two feed lines. We will report on the test of the first two-dimensional μMUX chip, consisting of 78 resonators. μMUX chips that pass screening will be directly bonded to MMC array chips using indium bump bonding. In parallel, we have tested a kinetic inductance traveling wave parametric amplifier (KI-TWPA) to amplify signals at low temperatures. The KI-TWPA exhibits extremely low internal noise, approaching the standard quantum limit. Since the energy resolution of an MMC is primarily limited by the readout system, the KI-TWPA is an ideal amplifier for MMCs with μMUX readout. We recently measured the readout noise of a μMUX with a KI-TWPA, demonstrating its capability for reading out MMC arrays. We present the design and fabrication of the latest MMC detectors, along with its readout performance.

Magntic Microcalorimeters↗

The Beam Dynamics and Beam Related Uncertainties in Fermilab Muon $g-2$ Experiment

The anomaly of the muon magnetic moment, $a_{\mu}\equiv (g-2)/2$, has played an important role in constraining physics beyond the Standard Model for many years. Currently, the Standard Model prediction for $a_{\mu}$ is accurate to 0.42 parts per million (ppm). The most recent muon $g-2$ experiment was done at Brookhaven National Laboratory (BNL) and determined $a_{\mu}$ to 0.54 ppm, with a central value that differs from the Standard Model prediction by 3.3-3.6 standard deviations and provides a strong hint of new physics. The Fermilab Muon $g-2$ Experiment has a goal to measure $a_{\mu}$ to unprecedented precision: 0.14 ppm, which could provide an unambiguous answer to the question whether there are new particles and forces that exist in nature. To achieve this goal, several items have been identified to lower the systematic uncertainties. In this work, we focus on the beam dynamics and beam associated uncertainties, which are important and must be better understood. We will discuss the electrostatic quadrupole system, particularly the hardware-related quad plate alignment and the quad extension and readout system. We will review the beam dynamics in the muon storage ring, present discussions on the beam related systematic errors, simulate the 3D electric fields of the electrostatic quadrupoles and examine the beam resonances. We will use a fast rotation analysis to study the muon radial momentum distribution, which provides the key input for evaluating the electric field correction to the measured $a_{\mu}$.

Wu, Wanwei↗

Development and testing of a prototype mosaic wedge-and-strip anode detector

A preliminary laboratory study of a prototype mosaic wedge-and-strip anode, a new class of readout system that will furnish large format, high resolution microchannel plate detectors with comparatively simple readout electronics is described. The goals of this study were to demonstrate the linearity of the mosaic anode algorithm, and to verify the predicted resolution performance in a realistic detector configuration. It is found that the nonlinearity introduced at the boundary between two anodes is limited to 50-100 microns. It is also shown that the spatial resolution of the detector is limited mainly by partition noise to about 35 microns (FWHM) at a gain of 2 x 10 to the 7th. A systematic investigation of the charge distribution arriving at the anode is also described. Using the relative charges arriving on the two anodes of the mosaic pattern, the detailed shape of the distribution and its dependence on MCP-anode voltage, MCP voltage, and pulse height are determined. A significant dependence of the profile on pulse height, which can introduce a pulse height dependence to the centroid calculation, particularly near the anode edges is found. Improved anode designs which will achieve the optimal performance are discussed.

Rasmussen, A.↗

Spectral contents readout of birefringent sensor

The technical objective of this research program was to develop a birefringent sensor, capable of measuring strain/stress up to 2000 F and a readout system based on Spectral Contents analysis. As a result of the research work, a data acquisition system was developed, capable of measuring strain birefringence in a sensor at 2000 F, with multi-point static and dynamic capabilities. The system uses a dedicated spectral analyzer for evaluation of stress-birefringence and a PC-based readout. Several sensor methods were evaluated. Fused silica was found most satisfactory. In the final evaluation, measurements were performed up to 2000 F and the system performance exceeded expectations.

Redner, Alex S.↗

Readout for Calorimetry at Future Colliders: A Snowmass 2021 White Paper

Calorimeters will provide critical measurements at future collider detectors. As the traditional challenge of high dynamic range, high precision, and high readout rates for signal amplitudes is compounded by increasing granularity and precision timing the readout systems will become increasingly complex. This white paper reviews the challenges and opportunities in calorimeter readout at future collider detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-cost clearance indicator for high speed turbomachinery

System consists of hermetically sealed capacitance probe, compact electronic driver, power supply, and oscilloscope and/or voltmeter for readout. System requires no mechanical connection to the rotating parts of turbomachinery, and does not disrupt rotor mainstream flow pattern. It can be effectively used in other applications to measure dynamic clearances between moving and stationary parts.

Evans, R. C.↗

Continuous bunch-by-bunch spectroscopic investigation of the microbunching instability

Electron accelerators and synchrotrons can be operated to provide short emission pulses due to longitudinally compressed or substructured electron bunches. Above a threshold current, the high charge density leads to the microbunching instability and the formation of substructures on the bunch shape. These time-varying substructures on bunches of picoseconds-long duration lead to bursts of coherent synchrotron radiation in the terahertz frequency range. Therefore, the spectral information in this range contains valuable information about the bunch length, shape and substructures. Based on the KAPTURE readout system, a 4-channel single-shot THz spectrometer capable of recording 500 million spectra per second and streaming readout is presented. First measurements of time-resolved spectra are compared to simulation results of the Inovesa Vlasov-Fokker-Planck solver. Finally, the presented results lead to a better understanding of the bursting dynamics especially above the micro-bunching instability threshold.

43 PARTICLE ACCELERATORS↗

Toward particle accelerator machine state embeddings as a modality for large language models

Understanding and diagnosing the state of a particle accelerator requires navigating high-dimensional control system data, often involving hundreds of interdependent parameters. We propose a novel multimodal embedding framework that jointly learns representations of machine states from both numerical control system readouts and natural language descriptions. This enables the translation of complex machine conditions into human-readable summaries while maintaining fidelity to the underlying physical system. The obtained embeddings are subsequently adapted to an open-weights large language model via cross-attention conditioning. We demonstrate a first implementation trained on European XFEL machine state data. This work covers the embedding model architecture, training methodology, and presents initial examples demonstrating the model's capabilities in action. Due to the general concept of machine state, the model can be easily adapted to other facilities and control system environments.

Accelerator Physics↗

Low-energy Electron-track Imaging for a Liquid Argon Time-projection-chamber Telescope Concept Using Probabilistic Deep Learning

The GammaTPC is an MeV-scale single-phase liquid argon time-projection-chamber gamma-ray telescope concept with a novel dual-scale pixel-based charge-readout system. It promises to enable a significant improvement in sensitivity to MeV-scale gamma rays over previous telescopes. The novel pixel-based charge readout allows for imaging of the tracks of electrons scattered by Compton interactions of incident gamma rays. The two primary contributors to the accuracy of a Compton telescope in reconstructing an incident gamma-ray’s original direction are its energy and position resolution. In this work, we focus on using deep learning to optimize the reconstruction of the initial position and direction of electrons scattered in Compton interactions, including using probabilistic models to estimate predictive uncertainty. We show that the deep-learning models are able to predict locations of Compton scatters of MeV-scale gamma rays from simulated 500 μm pixel-based data to better than 1 mm rms error and are sensitive to the initial direction of the scattered electron. We compare and contrast different deep-learning uncertainty estimation algorithms for reconstruction applications. Additionally, we show that event-by-event estimates of the uncertainty of the locations of the Compton scatters can be used to select those events that were reconstructed most accurately, leading to improvement in locating the origin of gamma-ray sources on the sky.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Design and Integrated Performance of SPT-3G

Abstract SPT-3G is the third survey receiver operating on the South Pole Telescope dedicated to high-resolution observations of the cosmic microwave background (CMB). Sensitive measurements of the temperature and polarization anisotropies of the CMB provide a powerful data set for constraining cosmology. Additionally, CMB surveys with arcminute-scale resolution are capable of detecting galaxy clusters, millimeter-wave bright galaxies, and a variety of transient phenomena. The SPT-3G instrument provides a significant improvement in mapping speed over its predecessors, SPT-SZ and SPTpol. The broadband optics design of the instrument achieves a 430 mm diameter image plane across observing bands of 95, 150, and 220 GHz, with 1.2′ FWHM beam response at 150 GHz. In the receiver, this image plane is populated with 2690 dual-polarization, trichroic pixels (∼16,000 detectors) read out using a 68× digital frequency-domain multiplexing readout system. In 2018, SPT-3G began a multiyear survey of 1500 deg 2 of the southern sky. We summarize the unique optical, cryogenic, detector, and readout technologies employed in SPT-3G, and we report on the integrated performance of the instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The ultrafast pixel array camera system and its applications in high energy density physics

Diagnostics in high energy density physics, shock physics, and related fields are primarily driven by a need to record rapidly time-evolving signals in single-shot events. These measurements are often limited by channel count and signal degradation issues on cable links between the detector and digitizer. Here we present the Ultrafast Pixel Array Camera (UPAC), a compact and flexible detector readout system with 32 waveform-recording channels at up to 10 Gsample/s and 1.8 GHz analog bandwidth. The compact footprint allows the UPAC to be directly embedded in the detector environment. A key enabling technology is the PSEC4A chip, an eight-channel switch-capacitor array sampling device with up to 1056 samples/channel. The UPAC system includes a high-density input connector that can plug directly into an application-specific detector board, programmable control, and serial readout, with less than 5 W of power consumption in full operation. We present the UPAC design and characterization, including a measured timing resolution of ~20 ps or better on acquisitions of sub-nanosecond pulses with minimal system calibrations. Example applications of the UPAC are also shown to demonstrate operation of a solid-state streak camera, an ultrafast imaging array, and a neutron time-of-flight spectrometer.

47 OTHER INSTRUMENTATION↗

Ultra-low magnetic field apparatus for a cryogenic gyroscope

An ultralow magnetic field apparatus for earth-based testing of a cryogenic gyroscope system designed for a satellite test of general relativity is described. The magnetic field apparatus makes use of a superconducting lead shield while also maintaining sufficient mechanical stability to obtain a gyroscope readout sensitivity of one arcsec over a limited range. A gyroscope environment of 2.3 times 10 to the minus seventh power gauss has been attained with the magnetic field shielding technique. The magnetic field apparatus is to be used with a three-axis London moment readout system.

Cabrera, B.↗

Evaluation of a positron-emission-tomography-based SiPM readout for compact segmented neutron imagers

Gamma-ray emission from special nuclear material (SNM) is relatively easy to shield from detection using modest amounts of high-Z material. In contrast, fast-neutrons are much more penetrating and can escape relatively thick high-Z shielding without losing significant energy. Furthermore, fast neutrons provide a clear and unambiguous signature of the presence of SNM with few competing natural background sources. The challenge of detecting fast neutrons is twofold. First, the neutron flux from SNM are only a fraction of the corresponding gamma-ray flux. Second, fast neutrons can be difficult to differentiate from gamma rays. The ability to discriminate gamma rays from neutrons, combined with a neutron imaging capability, can in some situations enable the localization of SNM neutron sources distinct from background. With the developments of pulse-shape-sensitive plastic scintillators that offer excellent gamma-ray/neutron discrimination, and arrays of silicon photomultipliers combined with highly scalable and fast positron-emission-tomography (PET) multi-channel readout systems, field-deployable neutron imagers suitable for SNM detection might now be within reach. In this paper, we present a characterization of the performance of a recently available commercial PET-scanner readout, including its sensitivity to pulse-shape differences between fast neutrons and gamma rays, energy and timing resolution. Here, we find that, while the pulse-shape discrimination is achievable with stilbene, further improvement of the readout is required to achieve it with the PSD-capable available plastic scintillators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and characterization of the SPT-3G receiver (Conference Presentation)

(On behalf of the SPT-3G collaboration)The SPT-3G receiver was commissioned in early 2017 on the 10-meter South Pole Telescope (SPT) to map the Cosmic Microwave Background (CMB) with arcminute resolution. The new instrument significantly improves on previous SPT camera designs, offering unprecedented sensitivity to the CMB’s temperature and polarization anisotropies while maintaining a tight control on systematic effects.A restructured optics chain features new secondary and tertiary mirrors to increase the receiver’s field of view by a factor of four in area, coupling light through a set of four cryogenic 720 mm alumina elements, which re-image the Gregorian focus inside the receiver. The broad-band (70-270 GHz) anti-reflective coated lenses are paired with a Lyot stop and cooled to 4 K using a dedicated two-stage pulse-tube cooler (PTC) to minimize in-band attenuation, internal radiative loading, and stray light on the considerably larger focal plane, which is populated with ~2,700 diffraction-limited pixels.Each independent pixel incorporates a lenslet-coupled broadband sinuous antenna, which routes signals through superconducting transmission lines and in-line band-defining filters to six transition-edge sensors, each measuring one of three bands (90, 150, and 220 GHz) and two polarizations, yielding a total of ~16,000 bolometers distributed across ten 150 mm monolithic wafers on a 430 mm image plane. A robust mechanical and thermal architecture supports and cools all detectors across this sizable focal plane to ~250 mK using a closed-cycle Helium adsorption refrigerator backed by a PTC, allowing a duty cycle greater than 90%.This order of magnitude increase in detector count relies on an improved digital frequency-domain SQUID readout system which integrates superconducting inductor-capacitor resonators wired in series with each bolometer to achieve a 68x multiplexing factor while mitigating noise and crosstalk effects.Cumulatively, SPT-3G’s new optics, detector, and readout strategies boast a potential factor of ~20 improvement in mapping speed over its predecessor, SPT-Pol, offering the potential to improve our understanding of inflationary physics, astroparticle physics, and growth of structure. We summarize the new receiver’s core design principles, outline technology characterization results, and report on plans for future upgrades.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗