Search NASA⌕ Search

SEARCH · Search NASA

Results for “RESIDUAL INTERACTIONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

To Biocide or not to Biocide? Exploring the "No Biocide" Option in Spacecraft Potable Water Systems

Residual biocide has been used to protect against microbial growth in spacecraft potable water systems since the Gemini program. Iodine, the biocide currently used on the International Space Station (ISS) has a long history of use but presents a few challenges for exploration: it must be removed using a consumable absorbent before crew consumption and is known to lose its biocidal concentration due to interactions with wetted components, especially during periods of dormancy. Biocidal silver is being considered for exploration missions as it is safe for crew consumption, but it too has challenges with proper material design to maintain sufficient disinfection residuals. An idea proposed by some in the Environmental Control and Life Support System (ECLSS) community has been that the biocide does not provide a true barrier against microbial growth, and therefore, perhaps the challenges of maintaining a residual biocide in the system could be best overcome by removing the biocide altogether. In this argument, they point to the regenerative water treatment system on the ISS which produces high purity water that theoretically meets the microbiological requirements before the iodine is added. Exploration water processing systems are expected to have similar water processing capabilities. This paper will discuss the role that residual biocide may play in controlling microbial growth and presents perspectives on the potential risks associated with removing it from exploration water systems.

biocide↗

To Biocide or not to Biocide? Exploring the "No Biocide" Option in Spacecraft Potable Water Systems

Residual biocide has been used to protect against microbial growth in spacecraft potable water systems since the Gemini program. Iodine, the biocide currently used on the International Space Station (ISS) has a long history of use but presents a few challenges for exploration: it must be removed using a consumable absorbent before crew consumption and is known to lose its biocidal concentration due to interactions with wetted components, especially during periods of dormancy. Biocidal silver is being considered for exploration missions as it is safe for crew consumption, but it too has challenges with proper material design to maintain sufficient disinfection residuals. An idea proposed by some in the Environmental Control and Life Support System (ECLSS) community has been that the biocide does not provide a true barrier against microbial growth, and therefore, perhaps the challenges of maintaining a residual biocide in the system could be best overcome by removing the biocide altogether. In this argument, they point to the regenerative water treatment system on the ISS which produces high purity water that theoretically meets the microbiological requirements before the iodine is added. Exploration water processing systems are expected to have similar water processing capabilities. This paper will discuss the role that residual biocide may play in controlling microbial growth and presents perspectives on the potential risks associated with removing it from exploration water systems.

biocide↗

To Biocide or Not to Biocide? Exploring the "No Biocide" Option in Spacecraft Potable Water Systems

Residual biocide has been used to protect against microbial growth in spacecraft potable water systems since the Gemini program. Iodine, the biocide currently used on the International Space Station (ISS) has a long history of use but presents a few challenges for exploration: it must be removed using a consumable absorbent before crew consumption and is known to lose its biocidal concentration due to interactions with wetted components, especially during periods of dormancy. Biocidal silver is being considered for exploration missions as it is safe for crew consumption, but it too has challenges with proper material design to maintain sufficient disinfection residuals. An idea proposed by some in the Environmental Control and Life Support System (ECLSS) community has been that the biocide does not provide a true barrier against microbial growth, and therefore, perhaps the challenges of maintaining a residual biocide in the system could be best overcome by removing the biocide altogether. In this argument, they point to the regenerative water treatment system on the ISS which produces high purity water that theoretically meets the microbiological requirements before the iodine is added. Exploration water processing systems are expected to have similar water processing capabilities. This paper will discuss the role that residual biocide may play in controlling microbial growth and presents perspectives on the potential risks associated with removing it from exploration water systems.

biocide↗

To Biocide or Not to Biocide? Exploring the "No Biocide" Option in Spacecraft Potable Water Systems

Residual biocide has been used to protect against microbial growth in spacecraft potable water systems since the Gemini program. Iodine, the biocide currently used on the International Space Station (ISS) has a long history of use but presents a few challenges for exploration: it must be removed using a consumable absorbent before crew consumption and is known to lose its biocidal concentration due to interactions with wetted components, especially during periods of dormancy. Biocidal silver is being considered for exploration missions as it is safe for crew consumption, but it too has challenges with proper material design to maintain sufficient disinfection residuals. An idea proposed by some in the Environmental Control and Life Support System (ECLSS) community has been that the biocide does not provide a true barrier against microbial growth, and therefore, perhaps the challenges of maintaining a residual biocide in the system could be best overcome by removing the biocide altogether. In this argument, they point to the regenerative water treatment system on the ISS which produces high purity water that theoretically meets the microbiological requirements before the iodine is added. Exploration water processing systems are expected to have similar water processing capabilities. This paper will discuss the role that residual biocide may play in controlling microbial growth and presents perspectives on the potential risks associated with removing it from exploration water systems.

biocide↗

The effect of water vapor on fatigue crack Growth in 7475-t651 aluminum alloy plate

The effects of water vapor on fatigue crack growth in 7475-T651 aluminum alloy plate at frequencies of 1 Hz and 10 Hz were investigated. Twenty-five mm thick compact specimens were subjected to constant amplitude fatigue testing at a load ratio of 0.2. Fatigue crack growth rates were calculated from effective crack lengths determined using a compliance method. Tests were conducted in hard vacuum and at water vapor partial pressures ranging from 94 Pa to 3.8 kPa. Fatigue crack growth rates were frequency insensitive under all environment conditions tested. For constant stress intensity factor ranges crack growth rate transitions occurred at low and high water vapor pressures. Crack growth rates at intermediate pressures were relatively constant and showed reasonable agreement with published data for two Al-Cu-Mg alloys. The existence of two crack growth rate transitions suggests either a change in rate controlling kinetics or a change in corrosion fatigue mechanism as a function of water vapor pressure. Reduced residual deformation and transverse cracking specimens tested in water vapor versus vacuum may be evidence of embrittlement within the plastic zone due to environmental interaction.

Dicus, D. L.↗

Effect of water vapor on fatigue crack growth in 7475-T651 aluminum alloy plate

The effects of water vapor on fatigue crack growth in 7475-T651 aluminum alloy plate at frequencies of 1 Hz and 10 Hz were investigated. Twenty-five mm thick compact specimens were subjected to constant amplitude fatigue testing at a load ratio of 0.2. Fatigue crack growth rates were calculated from effective crack lengths determined using a compliance method. Tests were conducted in hard vacuum and at water vapor partial pressures ranging from 94 Pa to 3.8 kPa. Fatigue crack growth rates were frequency insensitive under all environment conditions tested. For constant stress intensity factor ranges crack growth rate transitions occurred at low and high water vapor pressures. Crack growth rates at intermediate pressures were relatively constant and showed reasonable agreement with published data for two Al-Cu-Mg alloys. The existence of two crack growth rate transitions suggests either a change in rate controlling kinetics or a change in corrosion fatigue mechanism as a function of water vapor pressure. Reduced residual deformation and transverse cracking specimens tested in water vapor versus vacuum may be evidence of embrittlement within the plastic zone due to environmental interaction.

Dicus, D. L.↗

Matrix toughness, long-term behavior, and damage tolerance of notched graphite fiber-reinforced composite materials

The long-term behavior of notched graphite-fiber-reinforced composite laminates with brittle or tough matrix materials and different fiber architectures was investigated using damage measurements and stiffness change, residual strength, and life data. The fiber/matrix materials included T300/5208, AS4/3501-6, AS4/1808, AS4/PEEK, and C3000/PMR-15 matrices and unidirectional tape and woven cloth fiber architectures. Results of damage evaluation and of residual strength measurements during the fatigue damage development showed that the long-term behavior and damage tolerance are controlled by a number of interacting factors such as the matrix toughness, fiber architecture, loading levels, and damage types and distributions.

Bakis, C. E.↗

Mitigation of Silver Ion Loss from Solution by Polymer Coating of Metal Surfaces

Spacecraft potable water systems require a biocidal agent that effectively provides both immediate and residual disinfection over long periods of time. Ionic silver (Ag+) is a leading candidate for this application, but suffers from rapid concentration loss due interactions with the metal storage containers and tubing. In order to maintain biocidal efficacy in systems with long periods of dormancy and to reduce the required rate of Ag+ injection, it is necessary to develop alternative materials and coatings for certified metal alloys that significantly reduce the Ag+ loss. In this work, we investigate the performance of two unusual polymers, Teflon AF 2400 and parylene-AF4, as barrier coatings under immersion in 400 ppb Ag+. We show that 25 m-thick parylene-AF4 is a promising coating with Ag+ losses similar to PTFE. Key challenges with this material include maintenance of adhesion under long-term immersion and control of deposition during the internal coating of high-aspect ratio tubing. Solutions to these problems may including surface structuring of substrates for mechanical anchoring or an alternative parylene-C chemistry (with more stable adhesion), and dynamic spatio-temporal control of substrate temperature, respectively.

water↗

An experimental test of the homogeneity of the interstellar medium

Observations of nonthermal continuum radio emission at 750 MHz and hydrogen-line emission at 1420 MHz have been compared in order to test the extent to which cosmic-ray electrons, magnetic fields, and hydrogen gas coexist in the interstellar medium. If the interstellar medium is homogeneous in the sense that its constituents are mixed together and can interact, then regions of line and continuum emission should be spatially correlated. The measurements indicate that at most 28% of continuum emission in the Galaxy comes from such a homogeneous medium. The remaining nonthermal emission agrees in magnitude with the residual emission found by Berkhuijsen after subtraction of the polarized component of nonthermal emission. In addition, the data discussed here show that the major filamentary structures found in the two forms of emission rarely coincide spatially. Consequently, both the average and the exceptional structure in the medium indicate that the synchrotron-radiating magnetoplasma and the neutral hydrogen gas are not closely interacting in the present state of the medium.

Baker, P. L.↗

Topography of Small Volcanoes at the Margin of the Mars North Polar Cap

Putative volcanic craterforms have been observed in the north polar region of Mars since Mariner 9. Hodges and Moore described some of these features for the region they called the 'Borealis Volcanic Field', and suggested that several were formed as a consequence of magma-ice or magmawater interactions. Mars Orbiter Laser Altimeter (MOLA) topographic measurements confirm suggest that the features are unlikely to be of impact origin, and that there are many more of them present around the north polar cap than suspected from images alone. Analysis of one of the larger features--suggested by Hodges and Moore to represent a hydromagmatic explosion crater or maar--showed topographic characteristics more similar to a terrestrial small basaltic shield volcano, possibly of recent origins. Recent work with the MOLA topography has also suggested that the possible volcanic extent of the Borealis Field is substantially larger in both number and range than previously mapped. Since the majority of these features are within 100 km of the present edge of the northern residual polar cap, and several extend into the Chasma Boreale cap re-entrant, they are some of the best Mars candidates for possible magma-water or magma-ice interactions. However, so far, these features have not displayed the expected average slope or other characteristics predicted for martian hydrovolcanic features, or even martian explosive volcanic features. Here, we show some of the range of feature types observed in the topography, along with their characteristic topographic measurements, and compare them to terrestrial and martian volcanic features. Additional information is contained in the original extended abstract.

Sakimoto, S. E. H.↗

Recent advances in understanding stratospheric dynamics and transport processes - Application of satellite data to their interpretation

The present paper discusses the use of the transformed Eulerian (or 'residual') mean-flow formulation, the Eliassen-Palm flux, and Ertel's potential vorticity to provide an increased understanding of wave, mean-flow interactions, and constituent transport processes in the stratosphere. Temperature and ozone data retrieved from radiance profiles obtained by the LIMS instrument on the Nimbus 7 satellite are utilized in conjunction with these theoretical concepts for the interpretation of phenomena that occurred during the major and minor warmings of January-February 1979. The results illustrate the insight provided by these concepts and demonstrate that useful diagnostic quantities can be derived from global satellite temperature fields.

Grose, W. L.↗

The Martian polar cap - Radiative effects of ozone, clouds, and airborne dust

The solar and thermal flux striking the polar cap of Mars is computed for various ozone, dust, and cloud abundances and for three solar zenith angles. Ozone does not significantly affect the total energy budget of the polar cap. Hence the observed hemispherical asymmetry in ozone abundance causes only an insignificant hemispherical asymmetry in the polar caps. Vertical optical depths of dust and cloud ranging from zero to 1 cause little change in the total flux absorbed by the polar cap near its edge but increase the absorbed flux significantly as one travels poleward. Hemispherical asymmetries in dust abundance, cloud cover, and surface pressure combine to cause a significant hemispherical asymmetry in the total flux absorbed by the residual polar caps, which helps to explain the dichotomy in the residual polar caps on Mars. Other processes which affect the energy budget of the polar cap are proposed and reviewed, particularly with respect to their interaction with the radiative effects of clouds and dust.

Lindner, Bernhard Lee↗

Distribution of inorganic species in two Antarctic cryptoendolithic microbial communities

Chemical differences were noted between two Antarctic cryptoendolithic (hidden within rock) microenvironments colonized by different microbial communities. Microenvironments dominated by cyanobacteria (BPC) had a higher pH (pH 7-8) than those dominated by lichen (LTL) (pH 4.5-5.5). In order to understand the interactions between the microbiota and the inorganic environment, the inorganic environment was characterized. Water-soluble, carbonate-bound, metal-oxide, organically bound, and residual inorganic species were sequentially extracted from rock samples by chemical means. Each fraction was then quantified using inductively coupled plasma atomic emission spectrometry. BPC contained much more water-soluble and carbonate-bound Ca and Mg than LTL. Metal-oxide species of Al, Fe, and Mn were more abundant in LTL than BPC. Metal oxides appeared to be mobilized (in the order Mn > Fe > Al) from the LTL lichen zone but remained immobile in BPC sandstone. The distribution of K and P bound to metal oxide reflected the distribution of iron oxide in LTL, an indication of the importance of iron in controlling the availability of nutrients in this ecosystem. Metal oxides in turn were likely controlled or influenced by organic matter associated with the lichen community. Despite overall depletion of Fe, Al, and K in the lichen zone, SEM X-ray analysis showed that they were enriched in fungal hyphae. Water-soluble P was present despite the presence of metal oxides, which sequester phosphate. This has biological relevance since P is an essential nutrient.

NASA Program Exobiology↗

A Comparison of Two Balance Calibration Model Building Methods

Simulated strain-gage balance calibration data is used to compare the accuracy of two balance calibration model building methods for different noise environments and calibration experiment designs. The first building method obtains a math model for the analysis of balance calibration data after applying a candidate math model search algorithm to the calibration data set. The second building method uses stepwise regression analysis in order to construct a model for the analysis. Four balance calibration data sets were simulated in order to compare the accuracy of the two math model building methods. The simulated data sets were prepared using the traditional One Factor At a Time (OFAT) technique and the Modern Design of Experiments (MDOE) approach. Random and systematic errors were introduced in the simulated calibration data sets in order to study their influence on the math model building methods. Residuals of the fitted calibration responses and other statistical metrics were compared in order to evaluate the calibration models developed with different combinations of noise environment, experiment design, and model building method. Overall, predicted math models and residuals of both math model building methods show very good agreement. Significant differences in model quality were attributable to noise environment, experiment design, and their interaction. Generally, the addition of systematic error significantly degraded the quality of calibration models developed from OFAT data by either method, but MDOE experiment designs were more robust with respect to the introduction of a systematic component of the unexplained variance.

DeLoach, Richard↗

Mitigation of Silver Ion Loss from Solution by Polymer Coating of Metal Surfaces, Part II

“Spacecraft potable water systems require a biocidal agent that effectively provides both immediate and residual disinfection over long periods of time. Ionic silver (Ag+) is a leading candidate for this application, but suffers from rapid concentration loss due to interactions with the metal storage containers and tubing. In order to maintain biocidal efficacy in systems with long periods of dormancy and to reduce the required rate of Ag+ injection, it is necessary to develop alternative materials and coatings for certified metal alloys that significantly reduce the Ag+loss.”1In this work, we continue our investigation of vapor-deposited parylene (AF4, and now C) polymers as conformal barrier coatings under long-term (ca. 1-year) immersion in ca. 400 ppb Ag+. The performanceof internal coatings in tubing/two-ferrule fitting systems is characterized. We report successful “aging” and high concentration Ag+pretreatment of parylene coatings for quantitative reduction of Ag+loss rates. In addition, we observe long-term blister-free adhesion of mechanically anchored parylene-AF4 on nano-structured Ti-6Al-4V alloy and chemically bonded parylene-C on 316L stainless steel. Finally, we report preliminary experiments with mechanical and chemical anchoring of laboratory-deposited parylene-C on 316L.

Silver↗

Mitigation of Silver Ion Loss from Solution by Polymer Coating of Metal Surfaces, Part IV

“Spacecraft potable water systems require a biocidal agent that effectively provides both immediate and residual disinfection over long periods of time. Ionic silver (Ag+) is a leading candidate for this application, but suffers from rapid concentration loss due to interactions with the metallic storage containers and tubing. In order to maintain biocidal efficacy in systems with long periods of dormancy and to reduce the required rate of Ag+ injection, it is necessary to develop alternative materials and coatings for certified metal alloys that significantly reduce the Ag+ loss.” In previous reports, we have described our investigations addressing Ag+ loss mitigation and adhesion performance of parylene barrier coatings on coupons of several metal alloys and 316L tubing under static immersion. In such conditions, parylene-C and AF4 coatings have shown excellent Ag+ loss mitigation performance, and mixed long-term adhesion performance, depending on parylene species and substrate surface chemistry/structure. In Part IV of this series, we begin to address the performance of parylene-C barrier coatings under more challenging and realistic conditions, in order to evaluate potential suitability in flight systems. Using two testbeds, we characterized coating performance under dynamic mechanical operation. In the Flow/Pressure Testbed System, Ag+ solution is pumped through internally coated 316L tubing, with optional pressure cycling. In the Bellows Tank Testbed System, an internally coated edge-welded 316L bellows containing Ag+ solution is cyclically extended and compressed, analogous to the operation of bellows tanks used for potable water storage and delivery on the International Space Station. Periodic determinations of Ag+ loss with testbed cycling/time and visual observation of the parylene-C coatings were conducted. In addition, we characterized parylene-C coating resilience and Ag+ loss with 316L tubing and multiple fitting types under long-term immersion and repeated fitting dis/reassembly.

Lance Dean Delzeit↗

Thermochemical Stability of Ca2Yb8(SiO4)6O2 Apatite in Presence of Molten Calcium-Magnesium-AluminoSilicate (CMAS)

Thermochemical stability of ytterbium silicon oxyapatite Ca 2 Yb 8 (SiO 4 ) 6 O 2 (CYbS) in the presence of molten calcium-magnesium aluminosilicate (CMAS) has been investigated at elevated temperatures. CYbS apatite powder was synthesized from the constituent oxides via solid state reaction method. Hot pressed apatite substrates were exposed to molten CMAS at 1200, 1300, and 1400 °C for 1, 10, and 50 h. Development of phases in the interaction region of the heat-treated specimens was monitored using scanning electron microscopy, transmission electron microscopy, high angle annular dark field imaging, selected area electron diffraction and energy dispersive X-ray spectroscopy. Monoclinic cyclosilicate Ca 3 Yb 2 (Si 3 O 9 ) 2 formed from interaction of CYbS apatite with CaO in the CMAS melt at the apatite-CMAS reaction front and continued to nucleate and grow within the residual CMAS in diffusion couples annealed for 1-50 h at 1200 °C and those heat treated at 1300 °C for 1 h. Residual CMAS was Ca-depleted when cyclosilicate was present. Dendritic wollastonite CaSiO 3 was observed within the residual CMAS in couples annealed at 1200 and 1300 °C. Ingress of molten CMAS, because of its exponential decrease in viscosity, occurred through open pores and along the grain boundaries of the apatite substrates without any detectable chemical reaction at 1300 and 1400 °C. Results of this study indicate that Ca 2 Yb 8 (SiO 4 ) 6 O 2 apatite has the potential to mitigate the CMAS corrosion up to about 1200 °C but not at higher temperatures.

X-ray diffraction↗