Search NASA⌕ Search

SEARCH · Search NASA

Results for “ROI evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

A new background distribution-based active contour model for three-dimensional lesion segmentation in breast DCE-MRI

Purpose: To develop and evaluate a computerized semiautomatic segmentation method for accurate extraction of three-dimensional lesions from dynamic contrast-enhanced magnetic resonance images (DCE-MRIs) of the breast. Methods: The authors propose a new background distribution-based active contour model using level set (BDACMLS) to segment lesions in breast DCE-MRIs. The method starts with manual selection of a region of interest (ROI) that contains the entire lesion in a single slice where the lesion is enhanced. Then the lesion volume from the volume data of interest, which is captured automatically, is separated. The core idea of BDACMLS is a new signed pressure function which is based solely on the intensity distribution combined with pathophysiological basis. To compare the algorithm results, two experienced radiologists delineated all lesions jointly to obtain the ground truth. In addition, results generated by other different methods based on level set (LS) are also compared with the authors’ method. Finally, the performance of the proposed method is evaluated by several region-based metrics such as the overlap ratio. Results: Forty-two studies with 46 lesions that contain 29 benign and 17 malignant lesions are evaluated. The dataset includes various typical pathologies of the breast such as invasive ductal carcinoma, ductal carcinomain situ, scar carcinoma, phyllodes tumor, breast cysts, fibroadenoma, etc. The overlap ratio for BDACMLS with respect to manual segmentation is 79.55% ± 12.60% (mean ± s.d.). Conclusions: A new active contour model method has been developed and shown to successfully segment breast DCE-MRI three-dimensional lesions. The results from this model correspond more closely to manual segmentation, solve the weak-edge-passed problem, and improve the robustness in segmenting different lesions.

60 APPLIED LIFE SCIENCES↗

SU-C-202-02: A Comprehensive Evaluation of Adaptive Daily Planning for Cervical Cancer HDR Brachytherapy

Purpose: To evaluate adaptive daily planning for cervical cancer patients who underwent high-dose-rate intra-cavitary brachytherapy (HDR-ICBT). Methods: This study included 22 cervical cancer patients who underwent 5 fractions of HDR ICBT. Regions of interest (ROIs) including high-risk clinical tumor volume (HR-CTV) and organs-at-risk (OARs) were manually contoured on daily CT images. All patients were treated with adaptive daily plans, which involved ROI delineation and dose optimization at each treatment fraction. Single treatment plans were retrospectively generated by applying the first treatment fraction’s dwell times adjusted for decay and dwell positions of the applicator to subsequent treatment fractions. Various existing similarity metrics were calculated for the ROIs to quantify interfractional organ variations. A novel similarity score (JRARM) was established, which combined both volumetric overlap metrics (DSC, JSC, and RVD) and distance metrics (ASD, MSD, and RMSD). Linear regression was performed to determine a relationship between inter-fractional organ variations of various similarity metrics and D2cc variations from both plans. Wilcoxon Signed Rank Tests were used to assess adaptive daily plans and single plans by comparing EQD2 D2cc (α/β=3) for OARs. Results: For inter-fractional organ variations, the sigmoid demonstrated the greatest variations based on the JRARM and DSC similarity metrics. Comparisons between paired ROIs showed differences in JRARM scores and DSCs at each treatment fraction. RVD, MSD, and RMSD were found to be significantly correlated to D2cc variations for bladder and sigmoid. The comparison between plans found that adaptive daily planning provided lower EQD2 D2cc of OARs than single planning, specifically for the sigmoid (p=0.015). Conclusion: Substantial inter-fractional organ motion can occur during HDR-BT, which may significantly affect D2cc of OARs. Adaptive daily planning provides improved dose sparing for OARs compared to single planning.

60 APPLIED LIFE SCIENCES↗

SU-D-202-01: Functional Lung Avoidance and Response-Adaptive Escalation (FLARE) RT: Feasibility of a Precision Radiation Oncology Strategy

Purpose: NSCLC patient RT is planned without consideration of spatial heterogeneity in lung function or tumor response, which may have contributed to failed uniform dose escalation in a randomized trial. The feasibility of functional lung avoidance and response-adaptive escalation (FLARE) RT to reduce dose to [{sup 99m}Tc]MAA-SPECT/CT perfused lung while redistributing 74Gy within [{sup 18}F]FDG-PET/CT biological target volumes was assessed. Methods: Eight Stage IIB–IIIB NSCLC patients underwent FDG-PET/CT and MAA-SPECT/CT treatment planning scans. Perfused lung objectives were derived from scatter/collimator/attenuation-corrected MAA-SPECT uptake relative to ITV-subtracted lung to maintain <20Gy mean lung dose (MLD). Prescriptions included 60Gy to PTV and concomitant boost of 74Gy mean to biological target volumes (BTV=GTV+PET margin) scaled to each BTV voxel by relative FDG-PET SUV. Dose-painting-by-numbers prescriptions were integrated into commercial TPS via previously reported ROI discretization. Dose constraints for lung, heart, cord, and esophagus were defined. FLARE RT plans were optimized with VMAT, proton pencil beam scanning (PBS) with 3%-3mm robust optimization, and combination PBS (avoidance) plus VMAT (escalation). Dosimetric differences were evaluated by Friedman non-parametric paired test with multiple sampling correction. Results: PTV and normal tissue objectives were not violated in 24 FLARE RT plans. Population median of mean BTV dose was 73.7Gy (68.5–75.5Gy), mean FDG-PET peak dose was 89.7Gy (73.5–103Gy), MLD was 12.3Gy (7.5–19.6Gy), and perfused MLD was 4.8Gy (0.9–12.1Gy). VMAT achieved higher dose to the FDG-PET peak subvolume (p=0.01), while PBS delivered lower dose to lung (p<0.001). Voxelwise linear correlation between BTV dose and FDG-PET uptake was higher for VMAT (R=0.93) and PBS+VMAT (R=0.94) compared to PBS alone (R=0.89). Conclusion: FLARE RT is feasible with VMAT and PBS. A combination of PBS for functional lung avoidance and VMAT for FDG-PET dose escalation balances target/normal tissue objective tradeoffs. These results support future testing of FLARE RT safety and efficacy within a precision radiation oncology trial. This work was supported by a Research Scholar grant from the Radiological Society of North American Research & Education Foundation.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP3-02: Comparison of Magnitude and Frequency of Patient Positioning Errors in Breast Irradiation Using AlignRT 3D Optical Surface Imaging and Skin Mark Techniques

Purpose: To evaluate clinical usefulness of AlignRT (Vision RT Ltd., London, UK) in reducing patient positioning errors in breast irradiation. Methods: 60 patients undergoing whole breast irradiation were selected for this study. Patients were treated to the left or right breast lying on Qfix Access breast board (Qfix, Avondale, PA) in supine position for 28 fractions using tangential fields. 30 patients were aligned using AlignRT by aligning a breast surface region of interest (ROI) to the same area from a reference surface image extracted from planning CT. When the patient’s surface image deviated from the reference by more than 3mm on one or more translational and rotational directions, a new reference was acquired using AlignRT in-room cameras. The other 30 patients were aligned to the skin marks with room lasers. On-Board MV portal images of medial field were taken daily and matched to the DRRs. The magnitude and frequency of positioning errors were determined from measured translational shifts. Kolmogorov-Smirnov test was used to evaluate statistical differences of positional accuracy and precision between AlignRT and non-AlignRT patients. Results: The percentage of port images with no shift required was 46.5% and 27.0% in vertical, 49.8% and 25.8% in longitudinal, 47.6% and 28.5% in lateral for AlignRT and non-AlignRT patients, respectively. The percentage of port images requiring more than 3mm shifts was 18.1% and 35.1% in vertical, 28.6% and 50.8% in longitudinal, 11.3% and 24.2% in lateral for AlignRT and non-AlignRT patients, respectively. Kolmogorov-Smirnov test showed that there were significant differences between the frequency distributions of AlignRT and non-AlignRT in vertical, longitudinal, and lateral shifts. Conclusion: As confirmed by port images, AlignRT-assisted patient positioning can significantly reduce the frequency and magnitude of patient setup errors in breast irradiation compared to the use of lasers and skin marks.

60 APPLIED LIFE SCIENCES↗

TU-H-CAMPUS-IeP3-04: Evaluation of Changes in Quantitative Ultrasound Parameters During Prostate Radiotherapy

Purpose: Clarity Autoscan ultrasound monitoring system allows acquisition of raw radiofrequency (RF) ultrasound data prior and during radiotherapy. This enables the computation of 3D Quantitative Ultrasound (QUS) tissue parametric maps from. We aim to evaluate whether QUS parameters undergo changes with radiotherapy and thus potentially be used as early predictors and/or markers of treatment response in prostate cancer patients. Methods: In-vivo evaluation was performed under IRB protocol to allow data collection in prostate patients treated with VMAT whereby prostate was imaged through the acoustic window of the perineum. QUS spectroscopy analysis was carried out by computing a tissue power spectrum normalized to the power spectrum obtained from a quartz to remove system transfer function effects. A ROI was selected within the 3D image volume of the prostate. Because longitudinal registration was optimal, the same features could be used to select ROIs at roughly the same location in images acquired on different days. Parametric maps were generated within the rectangular ROIs with window sizes that were approximately 8 times the wavelength of the ultrasound. The mid-band fit (MBF), spectral slope (SS) and spectral intercept (SI) QUS parameters were computed for each window within the ROI and displayed as parametric maps. Quantitative parameters were obtained by averaging each of the spectral parameters over the whole ROI. Results: Data was acquired for over 21 treatment fractions. Preliminary results show changes in the parametric maps. MBF values decreased from −33.9 dB to −38.7 dB from pre-treatment to the last day of treatment. The spectral slope increased from −1.1 a.u. to −0.5 a.u., and spectral intercept decreased from −28.2 dB to −36.3 dB over the 21 treatment regimen. Conclusion: QUS parametric maps change over the course of treatment which warrants further investigation in their potential use for treatment planning and predicting treatment outcomes. Research was supported by Elekta.

60 APPLIED LIFE SCIENCES↗

A method to evaluate dose errors introduced by dose mapping processes for mass conserving deformations

Purpose: To present a method to evaluate the dose mapping error introduced by the dose mapping process. In addition, apply the method to evaluate the dose mapping error introduced by the 4D dose calculation process implemented in a research version of commercial treatment planning system for a patient case. Methods: The average dose accumulated in a finite volume should be unchanged when the dose delivered to one anatomic instance of that volume is mapped to a different anatomic instance--provided that the tissue deformation between the anatomic instances is mass conserving. The average dose to a finite volume on image S is defined as d{sub S}=e{sub s}/m{sub S}, where e{sub S} is the energy deposited in the mass m{sub S} contained in the volume. Since mass and energy should be conserved, when d{sub S} is mapped to an image R(d{sub S{yields}R}=d{sub R}), the mean dose mapping error is defined as {Delta}d{sub m}=|d{sub R}-d{sub S}|=|e{sub R}/m{sub R}-e{sub S}/m{sub S}|, where the e{sub R} and e{sub S} are integral doses (energy deposited), and m{sub R} and m{sub S} are the masses within the region of interest (ROI) on image R and the corresponding ROI on image S, where R and S are the two anatomic instances from the same patient. Alternatively, application of simple differential propagation yields the differential dose mapping error, {Delta}d{sub d}=|({partial_derivative}d/{partial_derivative}e)*{Delta}e+({partial_derivative}d/{partial_derivative}m)*{Delta}m|=|((e{sub S}-e{sub R})/m{sub R})-((m{sub S}-m{sub R})/m{sub R}{sup 2})*e{sub R}|={alpha}|d{sub R}-d{sub S}| with {alpha}=m{sub S}/m{sub R}. A 4D treatment plan on a ten-phase 4D-CT lung patient is used to demonstrate the dose mapping error evaluations for a patient case, in which the accumulated dose, D{sub R}={Sigma}{sub S=0}{sup 9}d{sub S{yields}R}, and associated error values ({Delta}D{sub m} and {Delta}D{sub d}) are calculated for a uniformly spaced set of ROIs. Results: For the single sample patient dose distribution, the average accumulated differential dose mapping error is 4.3%, the average absolute differential dose mapping error is 10.8%, and the average accumulated mean dose mapping error is 5.0%. Accumulated differential dose mapping errors within the gross tumor volume (GTV) and planning target volume (PTV) are lower, 0.73% and 2.33%, respectively. Conclusions: A method has been presented to evaluate the dose mapping error introduced by the dose mapping process. This method has been applied to evaluate the 4D dose calculation process implemented in a commercial treatment planning system. The method could potentially be developed as a fully-automatic QA method in image guided adaptive radiation therapy (IGART).

61 RADIATION PROTECTION AND DOSIMETRY↗

TU-AB-303-11: Predict Parotids Deformation Applying SIS Epidemiological Model in H&N Adaptive RT

Purpose: The aim is to investigate the use of epidemiological models to predict morphological variations in patients undergoing radiation therapy (RT). The susceptible-infected-susceptible (SIS) deterministic model was applied to simulate warping within a focused region of interest (ROI). Hypothesis is to consider each voxel like a single subject of the whole sample and to treat displacement vector fields like an infection. Methods: Using Raystation hybrid deformation algorithms and automatic re-contouring based on mesh grid, we post-processed 360 MVCT images of 12 H&N patients treated with Tomotherapy. Study focused on parotid glands, identified by literature and previous analysis, as ROI more susceptible to warping in H&N region. Susceptible (S) and infectious (I) cases were identified in voxels with inter-fraction movement respectively under and over a set threshold. IronPython scripting allowed to export positions and displacement data of surface voxels for every fraction. A MATLAB homemade toolbox was developed to model the SIS. Results: SIS model was validated simulating organ motion on QUASAR phantom. Applying model in patients, within a [0–1cm] range, a single voxel movement of 0.4cm was selected as displacement threshold. SIS indexes were evaluated by MATLAB simulations. Dynamic time warping algorithm was used to assess matching between model and parotids behavior days of treatments. The best fit of the model was obtained with contact rate of 7.89±0.94 and recovery rate of 2.36±0.21. Conclusion: SIS model can follow daily structures evolutions, making possible to compare warping conditions and highlighting challenges due to abnormal variation and set-up errors. By epidemiology approach, organ motion could be assessed and predicted not in terms of average of the whole ROI, but in a voxel-by-voxel deterministic trend. Identifying anatomical region subjected to variations, would be possible to focus clinic controls within a cohort of pre-selected patients eligible for adaptive RT. The research is partially co-funded by the Italian Research Grant: Dose warping methods for IGRT and Adaptive RT: dose accumulation based on organ motion and anatomical variations of the patients during radiation therapy treatments,MoH (GR-2010-2318757) and Tecnologie Avanzate S.r.l.(Italy)

60 APPLIED LIFE SCIENCES↗

Observer Evaluation of a Metal Artifact Reduction Algorithm Applied to Head and Neck Cone Beam Computed Tomographic Images

Purpose and Objectives: To quantify, through an observer study, the reduction in metal artifacts on cone beam computed tomographic (CBCT) images using a projection-interpolation algorithm, on images containing metal artifacts from dental fillings and implants in patients treated for head and neck (H&N) cancer. Methods and Materials: An interpolation-substitution algorithm was applied to H&N CBCT images containing metal artifacts from dental fillings and implants. Image quality with respect to metal artifacts was evaluated subjectively and objectively. First, 6 independent radiation oncologists were asked to rank randomly sorted blinded images (before and after metal artifact reduction) using a 5-point rating scale (1 = severe artifacts; 5 = no artifacts). Second, the standard deviation of different regions of interest (ROI) within each image was calculated and compared with the mean rating scores. Results: The interpolation-substitution technique successfully reduced metal artifacts in 70% of the cases. From a total of 60 images from 15 H&N cancer patients undergoing image guided radiation therapy, the mean rating score on the uncorrected images was 2.3 ± 1.1, versus 3.3 ± 1.0 for the corrected images. The mean difference in ranking score between uncorrected and corrected images was 1.0 (95% confidence interval: 0.9-1.2, P<.05). The standard deviation of each ROI significantly decreased after artifact reduction (P<.01). Moreover, a negative correlation between the mean rating score for each image and the standard deviation of the oral cavity and bilateral cheeks was observed. Conclusion: The interpolation-substitution algorithm is efficient and effective for reducing metal artifacts caused by dental fillings and implants on CBCT images, as demonstrated by the statistically significant increase in observer image quality ranking and by the decrease in ROI standard deviation between uncorrected and corrected images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-76: Comparing Homogeneity Between Gafchromic Film EBT2 and EBT3

Purpose: We found out that homogeneity of EBT2 was different among lot numbers in previous study. Variation in local homogeneity of EBT3 among several lot numbers has not been reported. In this study, we investigated film homogeneity of Gafcrhomic EBT3 films compared with EBT2 films. Methods: All sheets from five lots were cut into 12 pieces to investigate film homogeneity, and were irradiated at 0.5, 2, and 3 Gy. To investigate intra- and inter-sheet uniformity, five sheets from five lots were exposed to 2 Gy: intra-sheet uniformity was evaluated by the coefficient of variation of homogeneity for all pieces of a single sheet, and inter-sheet uniformity was evaluated by the coefficient of variation of homogeneity among the same piece numbers in the five sheets. To investigate the difference of ADC value in various doses, a single sheet from each of five lots was irradiated at 0.5 Gy and 3 Gy in addition to 2 Gy. A scan resolution of 72 dots per inch (dpi) and color depth of 48-bit RGB were used. Films were analyzed by the inhouse software; Average of ADC value in center ROI and profile X and Y axis were measured. Results and Conclusion: Intra-sheet uniformity of non-irradiated EBT2 films were ranged from 0.1% to 0.4%, however that of irradiated EBT2 films were ranged from 0.2% to 1.5%. On the other hand, intra-sheet uniformity of irradiated and non-irradiated EBT3 films were from 0.2% to 0.6%. Inter-sheet uniformity of all films were less than 0.5%. It was interesting point that homogeneity of EBT3 between no-irradiated and irradiated films were similar value, whereas EBT2 had dose dependence of homogeneity in ADC value evaluation. These results suggested that EBT3 homogeneity was corrected by this feature.

60 APPLIED LIFE SCIENCES↗

SU-F-R-30: Interscanner Variability of Radiomics Features in Computed Tomography (CT) Using a Standard ACR Phantom

Purpose: A simple approach to investigate Interscanner variability of Radiomics features in computed tomography (CT) using a standard ACR phantom. Methods: The standard ACR phantom was scanned on CT scanners from three different manufacturers. Scanning parameters of 120 KVp, 200 mA were used while slice thickness of 3.0 mm on two scanners and 3.27 mm on third scanner was used. Three spherical regions of interest (ROI) from water, medium density and high density inserts were contoured. Ninety four Radiomics features were extracted using an in-house program. These features include shape (11), intensity (22), GLCM (26), GLZSM (11), RLM (11), and NGTDM (5) and 8 fractal dimensions features. To evaluate the Interscanner variability across three scanners, a coefficient of variation (COV) is calculated for each feature group. Each group is further classified according to the COV- by calculating the percentage of features in each of the following categories: COV less than 2%, between 2 and 10% and greater than 10%. Results: For all feature groups, similar trend was observed for three different inserts. Shape features were the most robust for all scanners as expected. 70% of the shape features had COV <2%. For intensity feature group, 2% COV varied from 9 to 32% for three scanners. All features in four groups GLCM, GLZSM, RLM and NGTDM were found to have Interscanner variability ≥2%. The fractal dimensions dependence for medium and high density inserts were similar while it was different for water inserts. Conclusion: We concluded that even for similar scanning conditions, Interscanner variability across different scanners was significant. The texture features based on GLCM, GLZSM, RLM and NGTDM are highly scanner dependent. Since the inserts of the ACR Phantom are not heterogeneous in HU values suggests that matrix based 2nd order features are highly affected by variation in noise. Research partly funded by NIH/NCI R01CA190105-01.

60 APPLIED LIFE SCIENCES↗

Controls on the 36 Cl/Cl input ratio of paleo-groundwater in arid environments: New evidence from 81 Kr/Kr data

In this study, measurements of the long-lived 81 Kr and 36 Cl radioisotopes in groundwater from the Negev Desert (Israel) were used to assess the 36 Cl/Cl input ratios and Cl – contents for paleorecharge into the Nubian Sandstone Aquifer (NSA). The reconstructed Cl – content of the recharge flux was on the order of 300–400 mg/L. An initial 36 Cl/Cl ratio of 50 × 10 –15 was assessed for the groundwater replenishment in the Negev Desert since the late Pleistocene, in agreement with the 36 Cl/Cl ratios in recent local rainwater. This is despite possible changes in the climatic conditions and the 36 Cl production rates in the atmosphere over this timeframe. This similarity in values is explained by the major role played by the erosion and weathering of near-surface materials in the desert environment that dominate the hydrochemistry of rains, floods, and the consequent groundwater recharge. Spatial variation in the reconstructed initial 36 Cl/Cl ratio is accounted for by the differences in the mineral aerosol sources for specific recharge areas of the NSA. Accordingly, regional variations in the 36 Cl/Cl input in groundwater reservoirs surrounding the Mediterranean Sea indicate various processes that govern the 36 Cl/Cl system. Finally, the results of this study highlight the great advantage of integrating 81 Kr age information in evaluating the initial 36 Cl/Cl and Cl – input, which is essential for the calibration of 36 Cl radioisotope as an available long-term dating tool for a given basin.

54 ENVIRONMENTAL SCIENCES↗

SU-E-J-32: Dosimetric Evaluation Based On Pre-Treatment Cone Beam CT for Spine Stereotactic Body Radiotherapy: Does Region of Interest Focus Matter?

Purpose: Spine stereotactic body radiotherapy requires very conformal dose distributions and precise delivery. Prior to treatment, a KV cone-beam CT (KV-CBCT) is registered to the planning CT to provide image-guided positional corrections, which depend on selection of the region of interest (ROI) because of imperfect patient positioning and anatomical deformation. Our objective is to determine the dosimetric impact of ROI selections. Methods: Twelve patients were selected for this study with the treatment regions varied from C-spine to T-spine. For each patient, the KV-CBCT was registered to the planning CT three times using distinct ROIs: one encompassing the entire patient, a large ROI containing large bony anatomy, and a small target-focused ROI. Each registered CBCT volume, saved as an aligned dataset, was then sent to the planning system. The treated plan was applied to each dataset and dose was recalculated. The tumor dose coverage (percentage of target volume receiving prescription dose), maximum point dose to 0.03 cc of the spinal cord, and dose to 10% of the spinal cord volume (V10) for each alignment were compared to the original plan. Results: The average magnitude of tumor coverage deviation was 3.9%±5.8% with external contour, 1.5%±1.1% with large ROI, 1.3%±1.1% with small ROI. Spinal cord V10 deviation from plan was 6.6%±6.6% with external contour, 3.5%±3.1% with large ROI, and 1.2%±1.0% with small ROI. Spinal cord max point dose deviation from plan was: 12.2%±13.3% with external contour, 8.5%±8.4% with large ROI, and 3.7%±2.8% with small ROI. Conclusion: A small ROI focused on the target results in the smallest deviation from planned dose to target and cord although rotations at large distances from the targets were observed. It is recommended that image fusion during CBCT focus narrowly on the target volume to minimize dosimetric error. Improvement in patient setups may further reduce residual errors.

60 APPLIED LIFE SCIENCES↗

TU-H-CAMPUS-IeP2-01: Quantitative Evaluation of PROPELLER DWI Using QIBA Diffusion Phantom

Purpose: The purpose of this study is to determine the quantitative variability of apparent diffusion coefficient (ADC) values when varying imaging parameters in a diffusion-weighted (DW) fast spin echo (FSE) sequence with Periodically Rotated Overlapping ParallEL Lines with Enhanced Reconstruction (PROPELLER) k-space trajectory. Methods: Using a 3T MRI scanner, a NIST traceable, quantitative magnetic resonance imaging (MRI) diffusion phantom (High Precision Devices, Inc, Boulder, Colorado) consisting of 13 vials filled with various concentrations of polymer polyvinylpyrrolidone (PVP) in aqueous solution was imaged with a standard Quantitative Imaging Biomarkers Alliance (QIBA) DWI spin echo, echo planar imaging (SE EPI) acquisition. The same phantom was then imaged with a DWI PROPELLER sequence at varying echo train lengths (ETL) of 8, 20, and 32, as well as b-values of 400, 900, and 2000. QIBA DWI phantom analysis software was used to generate ADC maps and create region of interests (ROIs) for quantitative measurements of each vial. Mean and standard deviations of the ROIs were compared. Results: The SE EPI sequence generated ADC values that showed very good agreement with the known ADC values of the phantom (r2 = 0.9995, slope = 1.0061). The ADC values measured from the PROPELLER sequences were inflated, but were highly correlated with an r2 range from 0.8754 to 0.9880. The PROPELLER sequence with an ETL=20 and b-value of 0 and 2000 showed the closest agreement (r2 = 0.9034, slope = 0.9880). Conclusion: The DW PROPELLER sequence is promising for quantitative evaluation of ADC values. A drawback of the PROPELLER sequence is the longer acquisition time. The 180° refocusing pulses may also cause the observed increase in ADC values compared to the standard SE EPI DW sequence. However, the FSE sequence offers an advantage with in-plane motion and geometric distortion which will be investigated in future studies.

60 APPLIED LIFE SCIENCES↗

Evaluation of Deformable Image Coregistration in Adaptive Dose Painting by Numbers for Head-and-Neck Cancer

Purpose: To assess the accuracy of contour deformation and feasibility of dose summation applying deformable image coregistration in adaptive dose painting by numbers (DPBN) for head and neck cancer. Methods and Materials: Data of 12 head-and-neck-cancer patients treated within a Phase I trial on adaptive {sup 18}F-FDG positron emission tomography (PET)-guided DPBN were used. Each patient had two DPBN treatment plans: the initial plan was based on a pretreatment PET/CT scan; the second adapted plan was based on a PET/CT scan acquired after 8 fractions. The median prescription dose to the dose-painted volume was 30 Gy for both DPBN plans. To obtain deformed contours and dose distributions, pretreatment CT was deformed to per-treatment CT using deformable image coregistration. Deformed contours of regions of interest (ROI{sub def}) were visually inspected and, if necessary, adjusted (ROI{sub def{sub ad}}) and both compared with manually redrawn ROIs (ROI{sub m}) using Jaccard (JI) and overlap indices (OI). Dose summation was done on the ROI{sub m}, ROI{sub def{sub ad}}, or their unions with the ROI{sub def}. Results: Almost all deformed ROIs were adjusted. The largest adjustment was made in patients with substantially regressing tumors: ROI{sub def} = 11.8 {+-} 10.9 cm{sup 3} vs. ROI{sub def{sub ad}} = 5.9 {+-} 7.8 cm{sup 3} vs. ROI{sub m} = 7.7 {+-} 7.2 cm{sup 3} (p = 0.57). The swallowing structures were the most frequently adjusted ROIs with the lowest indices for the upper esophageal sphincter: JI = 0.3 (ROI{sub def}) and 0.4 (ROI{sub def{sub ad}}); OI = 0.5 (both ROIs). The mandible needed the least adjustment with the highest indices: JI = 0.8 (both ROIs), OI = 0.9 (ROI{sub def}), and 1.0 (ROI{sub def{sub ad}}). Summed doses differed non-significantly. There was a trend of higher doses in the targets and lower doses in the spinal cord when doses were summed on unions. Conclusion: Visual inspection and adjustment were necessary for most ROIs. Fast automatic ROI propagation followed by user-driven adjustment appears to be more efficient than labor-intensive de novo drawing. Dose summation using deformable image coregistration was feasible. Biological uncertainties of dose summation strategies warrant further investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-G-17A-02: Computer Simulation Studies for On-Board Functional and Molecular Imaging of the Prostate Using a Robotic Multi-Pinhole SPECT System

Purpose: To investigate prostate imaging onboard radiation therapy machines using a novel robotic, 49-pinhole Single Photon Emission Computed Tomography (SPECT) system. Methods: Computer-simulation studies were performed for region-of-interest (ROI) imaging using a 49-pinhole SPECT collimator and for broad cross-section imaging using a parallel-hole SPECT collimator. A male XCAT phantom was computersimulated in supine position with one 12mm-diameter tumor added in the prostate. A treatment couch was added to the phantom. Four-minute detector trajectories for imaging a 7cm-diameter-sphere ROI encompassing the tumor were investigated with different parameters, including pinhole focal length, pinhole diameter and trajectory starting angle. Pseudo-random Poisson noise was included in the simulated projection data, and SPECT images were reconstructed by OSEM with 4 subsets and up to 10 iterations. Images were evaluated by visual inspection, profiles, and Root-Mean- Square-Error (RMSE). Results: The tumor was well visualized above background by the 49-pinhole SPECT system with different pinhole parameters while it was not visible with parallel-hole SPECT imaging. Minimum RMSEs were 0.30 for 49-pinhole imaging and 0.41 for parallelhole imaging. For parallel-hole imaging, the detector trajectory from rightto- left yielded slightly lower RMSEs than that from posterior to anterior. For 49-pinhole imaging, near-minimum RMSEs were maintained over a broader range of OSEM iterations with a 5mm pinhole diameter and 21cm focal length versus a 2mm diameter pinhole and 18cm focal length. The detector with 21cm pinhole focal length had the shortest rotation radius averaged over the trajectory. Conclusion: On-board functional and molecular prostate imaging may be feasible in 4-minute scan times by robotic SPECT. A 49-pinhole SPECT system could improve such imaging as compared to broadcross-section parallel-hole collimated SPECT imaging. Multi-pinhole imaging can be improved by considering pinhole focal length, pinhole diameter, and trajectory starting angle. The project is supported by the NIH grant 5R21-CA156390.

60 APPLIED LIFE SCIENCES↗

Large-scale paleo water-table rise in a deep desert aquifer recorded by dissolved noble gases

Illuminating past hydrological and climatological conditions in arid regions may provide insights into future trends in groundwater availability. The main objective of this study is to explore paleorecharge processes in the deep regional Nubian Sandstone Aquifer (NSA), which stretches below the hyperarid deserts of the Sinai Peninsula (Egypt) and the Negev (Israel), using dissolved noble gas data. Extremely high amounts of dissolved excess air (Ne concentrations up to 4 × solubility equilibrium) were observed in the ancient ( 81 Kr-depleted) groundwater that was recharged during past pluvial epochs in the basin. Here, the observed unique excess air signal and the clear spatiotemporal structure of the noble gas compositions in the aquifer are hypothesized to reflect two major characteristics of the groundwater system: (a) large-scale, long-term rises in the water table that facilitate the entrapment and dissolution of air bubbles under increased hydrostatic pressure, and (b) the geological settings in the southern recharge area in Sinai, including an almost horizontal position of the layers and intercalation of low-permeability rock formations within the aquifer, which inefficiently reject air bubbles from groundwater, thereby allowing for substantial entrapment of bubbles that dissolve as the water table rises. Enhanced dissolution of entrapped air was also observed in other paleo-groundwater-containing regional sandstone aquifers across North Africa, which, together with the recent findings from the NSA, suggest that largescale water table fluctuations have likely extensively occurred during past pluvial periods over these (and possibly other) arid regions. A preliminary assessment of noble gas recharge temperatures (NGTs) indicates an apparent decoupling of surface and water table temperatures in the case of deep aquifers with a thick (hundreds of m) unsaturated zone. This observed decoupling calls for a re-evaluation of previously obtained NGT records and a need for future work to consider the modification of NGTs due to soil air fractionation and geothermal heating of the underlying deep unsaturated zones.

54 ENVIRONMENTAL SCIENCES↗

Proton dose calculation on scatter-corrected CBCT image: Feasibility study for adaptive proton therapy

Purpose: To demonstrate the feasibility of proton dose calculation on scatter-corrected cone-beam computed tomographic (CBCT) images for the purpose of adaptive proton therapy. Methods: CBCT projection images were acquired from anthropomorphic phantoms and a prostate patient using an on-board imaging system of an Elekta infinity linear accelerator. Two previously introduced techniques were used to correct the scattered x-rays in the raw projection images: uniform scatter correction (CBCT{sub us}) and a priori CT-based scatter correction (CBCT{sub ap}). CBCT images were reconstructed using a standard FDK algorithm and GPU-based reconstruction toolkit. Soft tissue ROI-based HU shifting was used to improve HU accuracy of the uncorrected CBCT images and CBCT{sub us}, while no HU change was applied to the CBCT{sub ap}. The degree of equivalence of the corrected CBCT images with respect to the reference CT image (CT{sub ref}) was evaluated by using angular profiles of water equivalent path length (WEPL) and passively scattered proton treatment plans. The CBCT{sub ap} was further evaluated in more realistic scenarios such as rectal filling and weight loss to assess the effect of mismatched prior information on the corrected images. Results: The uncorrected CBCT and CBCT{sub us} images demonstrated substantial WEPL discrepancies (7.3 ± 5.3 mm and 11.1 ± 6.6 mm, respectively) with respect to the CT{sub ref}, while the CBCT{sub ap} images showed substantially reduced WEPL errors (2.4 ± 2.0 mm). Similarly, the CBCT{sub ap}-based treatment plans demonstrated a high pass rate (96.0% ± 2.5% in 2 mm/2% criteria) in a 3D gamma analysis. Conclusions: A priori CT-based scatter correction technique was shown to be promising for adaptive proton therapy, as it achieved equivalent proton dose distributions and water equivalent path lengths compared to those of a reference CT in a selection of anthropomorphic phantoms.

60 APPLIED LIFE SCIENCES↗

Poster — Thur Eve — 09: Evaluation of electrical impedance and computed tomography fusion algorithms using an anthropomorphic phantom

Integration of biological conductivity information provided by Electrical Impedance Tomography (EIT) with anatomical information provided by Computed Tomography (CT) imaging could improve the ability to characterize tissues in clinical applications. In this paper, we report results of our study which compared the fusion of EIT with CT using three different image fusion algorithms, namely: weighted averaging, wavelet fusion, and ROI indexing. The ROI indexing method of fusion involves segmenting the regions of interest from the CT image and replacing the pixels with the pixels of the EIT image. The three algorithms were applied to a CT and EIT image of an anthropomorphic phantom, constructed out of five acrylic contrast targets with varying diameter embedded in a base of gelatin bolus. The imaging performance was assessed using Detectability and Structural Similarity Index Measure (SSIM). Wavelet fusion and ROI-indexing resulted in lower Detectability (by 35% and 47%, respectively) yet higher SSIM (by 66% and 73%, respectively) than weighted averaging. Our results suggest that wavelet fusion and ROI-indexing yielded more consistent and optimal fusion performance than weighted averaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗