At least 127 records · Page 7

RCT: Module 2.06, Airborne Sampling Program/Methods [Slides]

The inhalation of radioactive particles is the largest cause of internal dose in workplace incidents. Airborne radioactivity measurements are necessary to ensure that the control measures are, and continue to be, effective. Typically, airborne radioactivity levels are maintained well below allowable levels to keep the total effective dose equivalent small.

61 RADIATION PROTECTION AND DOSIMETRY↗

QUIC-DEPDOSE: Software tools to prepare for and respond to nuclear emergencies

QUIC-DEPDOSE is a software application that calculates radiation doses from inhalation of radionuclides downstream from an atmospheric radiological release. Unlike other radiological modeling software, QUIC-DEPDOSE can provide accurate dose information in as little as an hour running on a regular laptop, allowing for use by emergency responders after an accident.

61 RADIATION PROTECTION AND DOSIMETRY↗

Adaptable Technology Integration for Enhanced Worker Safety and Efficiency within the SPD Gloveboxes [Slides]

Surplus Plutonium Disposition (SPD) Overview: (1) Application Background – Location: Savannah River Site, Aiken, South Carolina – High backlog of plutonium material to process – Parallel lines of gloveboxes – Highly manual operations requiring full PPE and reader/worker steps; (2) Development Scope – Development of automated processes and opportunities to provide robust engineering design alternatives for baseline design that would meet process improvement goals.

61 RADIATION PROTECTION AND DOSIMETRY↗

Model Validation and Uncertainty Quantification on the KRUSTY Microreactor Design Using GRIFFIN Neutron Transport Code [Poster]

Argonne National Laboratory (ANL) and INL have developed a GRIFFIN steady state neutronics model for the multiphysics simulations of the Kilopower Reactor Using Sterling TechnologY (KRUSTY) microreactor in the Multiphysics Object Oriented Simulation Environment (MOOSE). The reliability of such deterministic neutronics models can be validated by comparing with computations from Monte Carlo codes (e.g. MCNP, SERPENT, OpenMC, Shift, etc). Furthermore, potential modeling/design improvements can be identified by incorporating uncertainty quantification (UQ), which can be performed by MOOSE’s Stochastic Tools Module (STM). KRUSTY is a prototype for a 5-kW thermal nuclear-powered space reactor. Its primary components consist of nuclear fuel, heat pipes, a control rod, a reflector, and the shielding. The fuel consists of 3 stacked U-7.65Mo cylinders with a hole in the center for the control rod. 8 liquid sodium heat pipes transfer fission energy from the solid fuel block to the Sterling power conversion system where the energy is extracted, and the cooled sodium flows back to the core via capillary action . The movable Boron Carbide control rod regulates the neutron population during startup or when a reactor temperature boost is needed . The beryllium oxide reflector is in 3 places in the reactor; it surrounds the core axially, it lies beneath the core on a platen, and it is present in the shim. The axial and lower reflectors rest on an adjustable stainless-steel platen that moves upward to cover the fuel and help the reactor reach criticality. Lastly, radial stainless steel surrounds the core offering protection from radiation exposure .

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

X-ray Security Imaging on Personal Dosimetry [Slides]

Federal regulations mandate that personal dosimetry devices — like optically stimulated luminescence (OSLs) — must be worn by all US Department of Energy (DOE) and associated radiation workers to track their occupational dose. Unfortunately, the inadvertent passage of OSLs through x-ray security scanners can compromise their validity. With the advent of high energy, advanced resolution security technology used in airports, this once insignificant issue now requires that Radiological Control (RadCon) be able to accurately discern non-occupational dose to effected OSLs. This presentation will discuss the principles, methods, and, rather surprising, models for establishing the corrective dose estimates at the Idaho National Laboratory (INL), and its implication across the DOE.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparison of Projections for a Short-Term Release, CAP88 vs NARAC

The purpose of this study was to compare the projected dose using different plume models, evaluating a short duration release of tritium to the 16 compliance sectors and 4 additional points of interest using local meteorology. This report is written as guidance to the decision makers when reviewing this specific Gaussian plume model intended for radiological dose assessment and regulatory compliance, called CAP88 1 , as compared to a more-complex model designed for emergency response. The emergency response model, NARAC 2 , can be used to supplement the CAP88 compliance model evaluations, since NARAC is intended for use in situations where releases are shorter in duration and have increased complexity in terrain and meteorology.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of the Radioactive Material Release in the Harborview Research and Training Building and Implications for Emergency Response

On May 2, 2019, during the 137 Cs source recovery operation, a source capsule in a research irradiator containing approximately 77.1 TBq was breached. Based on a geometric reconstruction analysis of the damage to the capsule, approximately 46.3 GBq (0.04%) was impacted by the chop saw (grinder) inside a Mobile Hot Cell (MHC) on the loading dock at the University of Washington Harborview Research and Training (HRT) Building. A very small fraction of the material impacted, less than 1%) was released from the Mobile Hot Cell and then to the rest of the HRT Building. The objectives of this project were to assess the accidental release of 137 CsCl and its implications related to emergency response methods and the ramifications of 137 CsCl transport. The phenomenology of this event was also compared with past alkali halide dispersal events. The vast number of measurements and samples collected by the remediation contractors, the Department of Energy's Nuclear Emergency Support Team, and the small number of retrospective samples collected by the authors informed the analysis. The techniques included (1) autoradiography and electron microscopy of samples collected from the HRT Building and the irradiator, (2) 3D visualization of deposition on surfaces and within the ventilation system, and (3) a study of the damage to the source capsule to evaluate the Cs particle size and particle composition due to the grinding accident. Subsequently, the cesium contaminant transport through the numerous pathways in the building was reconstructed to assess the deposition on surfaces as a function of particle size. The implications for emergency response are relevant to data quality and management. A Data Quality Objective (DQO) guides data collection methods so that they have appropriate accuracy and precision for the intended application. Recommendations were made with respect to the sample collection protocols and sample archival.

61 RADIATION PROTECTION AND DOSIMETRY↗

Initial Results of the Nuclear Accident Dosimetry Intercomparison at the Armed Forces Radiobiology Research Institute's TRIGA Reactor

This report presents the initial results for IER-602, the international nuclear accident dosimetry intercomparison performed at the Armed Forces Radiobiology Research Institute (AFRRI). Ten groups participated (six DOE laboratories, three international groups, and one DOD group) in a week-long exercise in late June 2024. Two additional groups observed the exercise (one DOE laboratory, one university). Three days of irradiations were performed, and participants reported results within 24 hours of the irradiations. Results were compared to the reference values and performance criteria established by IER-484 AFRRI ER1 Dosimetry Characterization and ANSI/HPS N13.3-2013, respectively. Passing performance varied from 17% to 100%, with an average of 67%.

61 RADIATION PROTECTION AND DOSIMETRY↗

Quartz Ampoule Loading, Sealing, and Inspection

This procedure applies to the loading of materials into quartz ampoules and flame sealing these ampoules. Flame sealed quartz ampoules are commonly used as a sealed containment for neutron irradiation. Due to the importance of maintaining containment for this application, this procedure involves a double encapsulation design wherein a sealed inner ampoule is sealed is in turn sealed within a larger diameter outer ampoule. General guidance for inspection of ampoules by destructive, non-destructive, qualitative (e.g., visual) and other methods are given. Materials to be placed inside the ampoules may consist of stable element materials or radioactive materials in either solid or liquid form. Liquids shall be dried prior to sealing the ampoule.

36 MATERIALS SCIENCE↗

Au-198 and TLD-600 results from IER-593 Godiva irradiations

This report summarizes the results from dosimetry packets deployed during a nominally 250 ◦C temperature rise Godiva IV burst. Dosimetry packets including Bare Au foils, Cd covered Au foils, and Thermoluminescent Dosimeters (TLDs) were deployed at five positions around Godiva at a height corresponding to the center height of the HEU fuel.

61 RADIATION PROTECTION AND DOSIMETRY↗

Full Submersion Water Testing of SAVY-4000 Nuclear Material Storage Containers

SAVY-4000 (SAVY) containers are the primary container used at Technical Area (TA) TA-55 plutonium facility for the prevention of water ingress to mitigate against a criticality event. The basis for water resistance of these containers has long been attributed to the Polytetrafluoroethylene (PTFE) membrane that is assembled on the outermost surface of the filter assembly. On August 22nd a test of a container used inside of a glovebox was performed that brought into question this long-standing-basis. This test was performed by inverting a SAVY-lid onto a specialized piece of equipment for evaluating the integrity of the PTFE membrane. During the test water was observed passing through the filter indicating that the filter membrane was no longer preventing the ingress of water through the filter. The assumption after making this observation was that alpha-particles were rapidly degrading the membrane creating a leak path through the underlying aluminosilicate media (Fiberfrax®). The apparatus used was designed to only test the lid rather than the entire SAVY assembly. A test plan, PA-PLAN-01921, was developed to investigate whether a fully assembled container with a fully degraded PTFE membrane would be capable of meeting the criteria defined in PA-RD-1009 of not allowing more than 200 ml of water to enter the container with a water column of 6-inches applied over a 2-hour period. This report provides the results of the testing performed against PA-PLAN-01921.

36 MATERIALS SCIENCE↗

Measuring the Aerosol Collection Efficiency and Detector Face Deposition of the Bladewerx KatanaGBM™ (Glove Box Monitor) Continuous Air Monitor

To assist Bladewerx LLC (the Requestor) in testing their new CAM (continuous air monitor) sampler model Bladewerx™ KatanaGBM™ (Glove Box Monitor), the Laboratory (LANL, i.e. Los Alamos National Laboratory) measured the aerosol particle collection efficiency and detector face deposition for several experimental test conditions. Bladewerx LLC provided a prototype KatanaGBM with a set of requested tests. According to these parameters, LANL designed and performed a series of experiments to (A.) Measure the aerosol particle collection efficiency and detector face deposition of the KatanaGBM at three air flow rates of 5, 42, and 70 ALPM (ambient liters per minute), (B.) Measure the collection efficiency and detector face deposition using two sizes of oil droplet particles: 3±1 and 10±1 µm (micron) AED (aerodynamic equivalent diameter), and (C.) Test the KatanaGBM for aerosol collection efficiency and detector face deposition with the wind tunnel’s air flow at three different angles 0°, 45° and 90° (compared to the KatanaGBM’s filter face).

61 RADIATION PROTECTION AND DOSIMETRY↗

Testing a Hazmatpac Can with Locking Ring as a Secondary Shipping Container for Radium-224/Lead-212 Generators

A Hazmatpac can, paint can style shipping container with locking ring, was tested for use as an alternative shipping configuration for shipment of radium- 224 /lead- 212 generators. 224 Ra ( t 1/2 = 3.63 d) decays by alpha emission to radon-220 ( t 1/2 = 55.6 s). The potential for the radioactive radon gas to escape the generator column and the shipping container is of particular concern for the safe delivery of 224 Ra/ 212 Pb generators to customers. The purpose of this study was to evaluate whether the Hazmatpac can is a suitable shipping configuration, capable of containing the radon gas that may escape the generator column during transit. A 17.3 mCi 224 Ra/ 212 Pb generator was built and packaged into a Hazmatpac can. The can was smeared by a Radiological Control Technician (RCT) every day for seven days to analyze for radioactive contamination on the outside of the can. Over the course of the study, no radioactive contamination was found on the outside of the can. Therefore, the Hazmatpac can was approved as an alternative shipping configuration for shipment of 224 Ra/ 212 Pb generators.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dose Exceedance Distance Sensitivity Based on Parametric Uncertainty

Sandia National Laboratories (SNL) collaborated with the US Nuclear Regulatory Commission's (NRC) Office of Nuclear Security and Incident Response (NSIR) and Office of Nuclear Regulatory Research (RES) to investigate the reasonable variability in the estimation of dose exceedance distances. SNL performed calculations using the MACCS code to elucidate the sensitivity of dose exceedance distances to variations in user input parameters.

61 RADIATION PROTECTION AND DOSIMETRY↗