Guidelines for effective radiation transport for cable SGEMP modeling

This report describes experiences gained in performing radiation transport computations with the SCEPTRE radiation transport code for System Generated ElectroMagnetic Pulse (SGEMP) applications. SCEPTRE is a complex code requiring a fairly sophisticated user to run the code effectively, so this report provides guidance for analysts interested in performing these types of calculations. One challenge in modeling coupled photon/electron transport for SGEMP is to provide a spatial mesh that is sufficiently resolved to accurately model surface charge emission and charge deposition near material interfaces. The method that has been most commonly used to date to compute cable SGEMP typically requires a sub-micron mesh size near material interfaces, which may be difficult for meshing software to provide for complex geometries. We present here an alternative method for computing cable SGEMP that appears to substantially relax this requirement. The report also investigates the effect of refining the energy mesh and increasing the order of the angular approximation to provide some guidance on determining reasonable parameters for the energy/angular approximation needed for x-ray environments. Conclusions for γ-ray environments may be quite different and will be treated in a subsequent report. In the course of the energy-mesh refinement studies, a bug in the cross-section generation software was discovered that may cause underprediction of the result by as much as an order of magnitude for the test problem studied here, when the electron energy group widths are much smaller than those for the photons. Results will be presented and compared using cross sections generated before and after the fix. We also describe adjoint modeling, which provides sensitivity of the total charge drive to the source energy and angle of incidence, which is quite useful for comparing the effect of changing the source environment and for determining most stressing angle of incidence and source energy. This report focusses on cable SGEMP applications, but many of the conclusions will be directly applicable for box Internal ElectroMagnetic Pulse (IEMP) modeling as well.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Advanced Mesh-Enabled Monte Carlo Capability for Multi-Physics Reactor Analysis

This project will accumulate high-precision fluxes throughout reactor geometry on a non-orthogonal grid of cells to support multi-physics coupling, in order to more accurately calculate parameters such as reactivity coefficients and to generate multi-group cross sections. This work will be based upon recent developments to incorporate advanced geometry and mesh capability in a modular Monte Carlo toolkit with computational science technology that is in use in related reactor simulation software development. Coupling this capability with production-scale Monte Carlo radiation transport codes can provide advanced and extensible test-beds for these developments. Continuous energy Monte Carlo methods are generally considered to be the most accurate computational tool for simulating radiation transport in complex geometries, particularly neutron transport in reactors. Nevertheless, there are several limitations for their use in reactor analysis. Most significantly, there is a trade-off between the fidelity of results in phase space, statistical accuracy, and the amount of computer time required for simulation. Consequently, to achieve an acceptable level of statistical convergence in high-fidelity results required for modern coupled multi-physics analysis, the required computer time makes Monte Carlo methods prohibitive for design iterations and detailed whole-core analysis. More subtly, the statistical uncertainty is typically not uniform throughout the domain, and the simulation quality is limited by the regions with the largest statistical uncertainty. In addition, the formulation of neutron scattering laws in continuous energy Monte Carlo methods makes it difficult to calculate adjoint neutron fluxes required to properly determine important reactivity parameters. Finally, most Monte Carlo codes available for reactor analysis have relied on orthogonal hexahedral grids for tallies that do not conform to the geometric boundaries and are thus generally not well-suited to coupling with the unstructured meshes that are used in other physics simulations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

MCNP Version 6.2 Release Notes

Monte Carlo N-Particle or MCNP ® is a general-purpose Monte Carlo radiation-transport code designed to track many particle types over broad ranges of energies. This MCNP Version 6.2 follows the MCNP6.1.1 beta version and has been released in order to provide the radiation transport community with the latest feature developments and bug fixes for MCNP. Since the last release of MCNP major work has been conducted to improve the code base, add features, and provide tools to facilitate ease of use of MCNP version 6.2 as well as the analysis of results. These release notes serve as a general guide for the new/improved physics, source, data, tallies, unstructured mesh, code enhancements and tools. For more detailed information on each of the topics, please refer to the appropriate references or the user manual which can be found at http://mcnp.lanl.gov. This release of MCNP version 6.2 contains 39 new features in addition to 172 bug fixes and code enhancements. There are still some 33 known issues the user should familiarize themselves with (see Appendix).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A METHODOLOGY FOR DETERMINING THE DOSE RATE FOR BOUNDING MASS LIMITS IN A 9977 PACKAGING

The Small Gram Quantity (SGQ) concept is based on the understanding that the hazards associated with the shipment of a radioactive material are directly proportional to its mass. This study describes a methodology that estimates the acceptable masses for several neutron and gamma emitting isotopes that can be shipped in a 9977 Package compliant with the Title 10 of the Code of Federal Regulations, Part 71 (10CFR71) external radiation level limits. 10CFR71.33 states that a shipping application identifies the radioactive and fissile materials at their maximum quantity and provides an evaluation demonstrating compliance with the external radiation standards. Since rather small amounts of some isotopes emit sufficiently strong radiation to produce a large external dose rate, quantifying of the dose rate for a proposed content is a challenging issue for the SGQ approach. It is essential to quantify external radiation levels from several common gamma and neutron sources that can be safely placed in a specific packaging, to ensure compliance with federal regulations. A methodology was established for determining the dose rate for bounding mass limits for a set of isotopes in the Model 9977 Shipping Package. Calculations were performed to estimate external radiation levels using the MCNP radiation transport code to develop a set of response multipliers (Green's functions) for 'dose per source particle' for each neutron and photon spectral group. The source spectrum from one gram of each isotope was folded with the response multipliers to generate the dose rate per gram of each isotope in the 9977 shipping package and its associated shielded containers. The maximum amount of a single isotope that could be shipped within the regulatory limits for dose rate at the surface was determined. For a package containing a mixture of isotopes, the acceptability for shipment can be determined by a sum of fractions approach. Furthermore, the results of this analysis can be easily extended to additional radioisotopes by simply evaluating the neutron and/or photon spectra of those isotopes and folding the spectral data with the Green's functions provided.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The MCNP ® 6 code: A decade of progress

After several years of effort involved in merging the Los Alamos National Laboratory MCNP5 and MCNPX codes, in 2013 the first production release of version 6 of the Monte Carlo N-Particle ® , or MCNP ® , code MCNP6.1 was distributed publicly. Since then, three significant releases have been issued: MCNP6.1.1beta in 2014, MCNP6.2 in 2018, and MCNP6.3 in 2023. While each release always contains new features, code enhancements, and bug fixes, each version has had a different primary focus, ranging from improved calculational efficiency to new powerful utilities and tools, to software modernization of the code base. With all that has been learned over the first decade of the MCNP6 code, continuous progress is being made toward a modernized, general-purpose Monte Carlo radiation transport code that remains a trusted resource for the global community of practitioners. This paper describes these first 10+ years of the MCNP6 code and its continually improving data libraries, and gives some insight into how the next decade is expected to unfold.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of CSG-based radiation shielding module for ARCHER: preliminary results for photons - Paper 126

ARCHER is a parallel Monte Carlo radiation transport code being developed for various hardware platforms including multi-core CPUs, the emerging Nvidia graphics processing units (GPUs) and Intel Xeon Phi coprocessors. Previous studies have demonstrated the accuracy and speed for CT imaging and radiotherapy dosimetry applications. Radiation shielding applications, however, require ARCHER to be more flexible in defining and handling geometries, in addition to the voxel phantom geometries that are commonly used in medical physics calculations. In this paper, we present the development of a general geometry module used for radiation protection and shielding problems in ARCHER. The methods of geometry design and particle transport for the GPUs are introduced. Preliminary results comparing against the MCNP code for cases involving Cs-137 0.662 MeV gammas are reported. The radiation shielding design module of ARCHER has been developed, which supports general geometry setups in the CSG format. The code was implemented using CUDA on Nvidia GPUs, and the performance was benchmarked against the MCNP code for a simple radiation shielding problem. Results showed that ARCHER worked properly and achieved impressive speedup due to highly parallel computing nature of the Nvidia GPUs compared to the MCNP code running on multi-core CPUs. Further optimization of the geometry module will be carried out using advanced geometry structures and variance reduction techniques to improve the precision and performance of ARCHER. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Jet signatures in the spectra of accreting black holes

Jets are observed as radio emission in active galactic nuclei and during the low/hard state in X-ray binaries (XRBs), but their contribution at higher frequencies has been uncertain. We study the dynamics of jets in XRBs using the general-relativistic magnetohydrodynamic code HARM. We calculate the high-energy spectra and variability properties using a general-relativistic radiative transport code based on grmonty. We find the following signatures of jet emission: (i) a significant γ-ray peak above ∼10{sup 22} Hz, (ii) a break in the optical/UV spectrum, with a change from νL{sub ν}∼ν{sup 0} to νL{sub ν}∼ν, followed by another break at higher frequencies where the spectrum roughly returns to νL{sub ν}∼ν{sup 0}, and (iii) a pronounced synchrotron peak near or below ∼10{sup 14} Hz indicates that a significant fraction of any observed X-ray emission originates in the jet. We investigate the variability during a large-scale magnetic field inversion in which the Blandford–Znajek (BZ) jet is quenched and a new transient hot reconnecting plasmoid is launched by the reconnecting field. The ratio of the γ-rays to X-rays changes from L{sub γ}/L{sub X}>1 in the BZ jet to L{sub γ}/L{sub X}<1 during the launching of the transient plasmoid.

79 ASTRONOMY AND ASTROPHYSICS↗

The CINDER'90 transmutation code package for use in accelerator applications in combination with MCNPX

CINDER'90, a nuclear inventory code originated at the Bettis Atomic Power Laboratory for reactor irradiation calculations and extended for use of in accelerator dr iven systems and high-energy applications at Los Alamos National Laboratory, has been released as a code package for distribution through the Radiation Safety Information Computational Center (RSICC). The code package and its updated data libraries come with several scripts that allow calculations of multi-cell problems in combination with the radiation transport code MCNPX. A script was developed that manages all the pre-processing steps extracting the necessary information from MCNPX output or from one input file, and that runs the CINDER’90 code for a requested list of MCNPX cells and for a requested time history. A second script was developed that extracts the decay photon sources from CINDER’90 output for a requested list of cells and for a requested irradiation or decay time step and builds source deck for subsequent MCNPX calculations. Since the package release, improvements to CINDER’90 are underway in algorithms, libraries, and interfaces to transport codes.

43 PARTICLE ACCELERATORS↗

Note: Neutron shutter for Kolkata superconducting cyclotron

In particle accelerator facilities, experimental areas are isolated from active accelerator area with thick concrete walls. A neutron shutter is used to isolate the experimental areas from the active accelerator area in the beam line. These shutters are provided primarily to reduce the secondary radiations like neutrons in the experimental areas to permissible limit when the primary beam is blocked in the accelerator area. The reduced radiation level in the experimental areas makes the experimental areas accessible. The shutters should allow the primary beam to pass to the experimental caves when they retracted from the beam line. A new neutron shutter has been designed and fabricated. This shutter incorporates compact features with considerable reduction in length, surface area and volume. The attenuation of secondary radiations is evaluated using Monte-Carlo radiation transport code FLUKA. It is found that the features of the shutter are sufficiently good enough to reduce the diffused secondary radiations well within the permissible levels.

43 PARTICLE ACCELERATORS↗

Modeling The Nucleosynthetic Imprint of Stellar Merger Phenomena - Final Technical Report

This DOE CAREER project developed a comprehensive, multi-physics framework for modeling stellar mergers and their observable consequences. The work successfully integrated analytical models, three-dimensional hydrodynamic simulations, stellar evolution calculations, nucleosynthesis, and radiation transport into a unified pipeline. Key scientific advances include demonstrating stellar mergers as a unifying explanation for systems such as Betelgeuse and R Coronae Borealis stars, quantifying merger-driven chemical signatures, and establishing the connection between merger physics and circumstellar environments. A major outcome of the project is the development of SuperLite, an open-source Monte Carlo radiation transport code that enables the generation of synthetic spectra for astrophysical transients. This work bridges dynamical, thermal, and radiative timescales and provides a powerful, DOE-relevant computational framework for interpreting observations of supernovae and related transient phenomena, while also contributing to workforce development through the training of postdoctoral researchers and graduate students.

Chatzopoulos, Emmanouil [Louisiana State Universit↗

Benchmark study of TRIPOLI-4 through experiment and MCNP codes

Reliability on simulation results is essential in nuclear physics. Although MCNP5 and MCNPX are the world widely used 3D Monte Carlo radiation transport codes, alternative Monte Carlo simulation tools exist to simulate neutral and charged particles' interactions with matter. Therefore, benchmark are required in order to validate these simulation codes. For instance, TRIPOLI-4.7, developed at the French Alternative Energies and Atomic Energy Commission for neutron and photon transport, now also provides the user with a full feature electron-photon electromagnetic shower. Whereas the reliability of TRIPOLI-4.7 for neutron and photon transport has been validated yet, the new development regarding electron-photon matter interaction needs additional validation benchmarks. We will thus demonstrate how accurately TRIPOLI-4's 'deposited spectrum' tally can simulate gamma spectrometry problems, compared to MCNP's 'F8' tally. The experimental setup is based on an HPGe detector measuring the decay spectrum of an {sup 152}Eu source. These results are then compared with those given by MCNPX 2.6d and TRIPOLI-4 codes. This paper deals with both the experimental aspect and simulation. We will demonstrate that TRIPOLI-4 is a potential alternative to both MCNPX and MCNP5 for gamma-electron interaction simulation. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CEPXS

CEPXS is a multigroup-Legendre cross-section generating code. The cross sections produced by CEPXS enable coupled electron-photon transport calculations to be performed with multigroup radiation transport codes, e.g. MITS and SCEPTRE. CEPXS generates multigroup-Legendre cross sections for photons, electrons and positrons over the energy range from 100 MeV to 1.0 keV. The continuous slowing-down approximation is used for those electron interactions that result in small-energy losses. The extended transport correction is applied to the forward-peaked elastic scattering cross section for electrons. A standard multigroup-Legendre treatment is used for the other coupled electron-photon cross sections. CEPXS extracts electron cross-section information from the DATAPAC data set and photon cross-section information from Biggs-Lighthill data. The model that is used for ionization/relaxation in CEPXS is essentially the same as that employed in ITS.

Source record↗

EMPHASIS/Nevada CABANA user Guide. Version 2.0.

The CABle ANAlysis (CABANA) portion of the EMPHASIS{trademark} suite is designed specifically for the simulation of cable system-generated electromagnetic pulse (SGEMP). The code can be used to evaluate the response of a specific cable design to threat or to compare and minimize the relative response of difference designs. This document provides user-specific information to facilitate the application of the code to cables of interest. It solves the electrical portion of a cable SGEMP simulation. It takes specific results from the deterministic radiation-transport code CEPTRE as sources and computes the resulting electrical response to an arbitrary cable load. The cable geometry itself is also arbitrary and is limited only by the patience of the user in meshing and by the available computing resources for the solution. The CABANA simulation involves solution of the quasi-static Maxwell equations using finite-element method (FEM) techniques.

99 GENERAL AND MISCELLANEOUS↗

SU-E-I-42: Normalized Embryo/fetus Doses for Fluoroscopically Guided Pacemaker Implantation Procedures Calculated Using a Monte Carlo Technique

Purpose: It is well known that pacemaker implantation is sometimes needed in pregnant patients with symptomatic bradycardia. To our knowledge, there is no reported experience regarding radiation doses to the unborn child resulting from fluoroscopy during pacemaker implantation. The purpose of the current study was to develop a method for estimating embryo/fetus dose from fluoroscopically guided pacemaker implantation procedures performed on pregnant patients during all trimesters of gestation. Methods: The Monte Carlo N-Particle (MCNP) radiation transport code was employed in this study. Three mathematical anthropomorphic phantoms representing the average pregnant patient at the first, second and third trimesters of gestation were generated using Bodybuilder software (White Rock science, White Rock, NM). The normalized embryo/fetus dose from the posteroanterior (PA), the 30° left-anterior oblique (LAO) and the 30° right-anterior oblique (RAO) projections were calculated for a wide range of kVp (50–120 kVp) and total filtration values (2.5–9.0 mm Al). Results: The results consist of radiation doses normalized to a) entrance skin dose (ESD) and b) dose area product (DAP) so that the dose to the unborn child from any fluoroscopic technique and x-ray device used can be calculated. ESD normalized doses ranged from 0.008 (PA, first trimester) to 2.519 μGy/mGy (RAO, third trimester). DAP normalized doses ranged from 0.051 (PA, first trimester) to 12.852 μGy/Gycm2 (RAO, third trimester). Conclusion: Embryo/fetus doses from fluoroscopically guided pacemaker implantation procedures performed on pregnant patients during all stages of gestation can be estimated using the method developed in this study. This study was supported by the Greek Ministry of Education and Religious Affairs, General Secretariat for Research and Technology, Operational Program ‘Education and Lifelong Learning’, ARISTIA (Research project: CONCERT)

60 APPLIED LIFE SCIENCES↗

ENDF/B-VIII.1 Validation (Preliminary Release 2 + New 239 Pu)

This document should serve as a reference for validation testing of nuclear data files included in the second preliminary release of ENDF/B-VIII.1 and the newly evaluated 239 Pu nuclear data file to be included in the third preliminary release of ENDF/B-VIII.1. Experiment names listed in this report are based on International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook designations. Additional information on ICSBEP handbook designations can be found at https://www.oecd-nea.org/jcms/pl_20291/icsbep-handbook. The validation metrics used in this report include the effective neutron multiplication factor, k eff , and tritium production. All validation metrics were calculated using the radiation transport code Monte Carlo N-Particle (MCNP).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

NUMERICAL MODELING OF MULTI-WAVELENGTH SPECTRA OF M87 CORE EMISSION

Spectral fits to M87 core data from radio to hard X-ray are generated via a specially selected software suite, comprised of the High-Accuracy Relativistic Magnetohydrodynamics GRMHD accretion disk model and a two-dimensional Monte Carlo radiation transport code. By determining appropriate parameter changes necessary to fit X-ray-quiescent and flaring behavior of M87's core, we assess the reasonableness of various flaring mechanisms. This shows that an accretion disk model of M87's core out to 28 GM/c{sup 2} can describe the inner emissions. High spin rates show GRMHD-driven polar outflow generation, without citing an external jet model. Our results favor accretion rate changes as the dominant mechanism of X-ray flux and index changes, with variations in density of approximately 20% necessary to scale between the average X-ray spectrum and flaring or quiescent spectra. The best-fit parameters are black hole spin a/M > 0.8 and maximum accretion flow density n {<=} 3 Multiplication-Sign 10{sup 7} cm{sup -3}, equivalent to horizon accretion rates between m-dot = M-dot / M-dot{sub Edd}{approx}2 Multiplication-Sign 10{sup -6} and 1 Multiplication-Sign 10{sup -5} (with M-dot{sub Edd} defined assuming a radiative efficiency {eta} = 0.1). These results demonstrate that the immediate surroundings of M87's core are appropriate to explain observed X-ray variability.

79 ASTRONOMY AND ASTROPHYSICS↗

Assessment of Nuclear Resonance Fluorescence for Spent Nuclear Fuel Assay

In nuclear resonance fluorescence (NRF) measurements, resonances are excited by an external photon beam leading to the emission of gamma rays with specific energies that are characteristic of the emitting isotope. NRF promises the unique capability of directly quantifying a specific isotope without the need for unfolding the combined responses of several fissile isotopes as is required in other measurement techniques. We have analyzed the potential of NRF as a non-destructive analysis technique for quantitative measurements of Pu isotopes in spent nuclear fuel (SNF). Given the low concentrations of 239Pu in SNF and its small integrated NRF cross sections, the main challenge in achieving precise and accurate measurements lies in accruing sufficient counting statistics in a reasonable measurement time. Using analytical modeling, and simulations with the radiation transport code MCNPX that has been experimentally tested recently, the backscatter and transmission methods were quantitatively studied for differing photon sources and radiation detector types. Resonant photon count rates and measurement times were estimated for a range of photon source and detection parameters, which were used to determine photon source and gamma-ray detector requirements. The results indicate that systems based on a bremsstrahlung source and present detector technology are not practical for high-precision measurements of 239Pu in SNF. Measurements that achieve the desired uncertainties within hour-long measurements will either require stronger resonances, which may be expressed by other Pu isotopes, or require quasi-monoenergetic photon sources with intensities that are approximately two orders of magnitude higher than those currently being designed or proposed.This work is part of a larger effort sponsored by the Next Generation Safeguards Initiative to develop an integrated instrument, comprised of individual NDA techniques with complementary features, that is fully capable of determining Pu mass in spent fuel assemblies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Exnihilo User's Manuals Release 5.3 (Dev)

Exnihilo is a modern radiation transport framework that implements a variety of advanced solvers and solution method- ologies, enabling it to solve a wide variety of nuclear engineering and applications problems with the scalability to run on both desktop machines and leadership-class supercomputers. It supports "stand-alone" execution using its internal front ends, but its components (such as the the Denovo S N solver) are also integrated into other radiation transport codes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗