Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radio Frequency Identification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Jefferson Laboratory C100 Superconducting Radio-Frequency Cavity Fault Data, 2020

The dataset was created to train machine learning models for the task of identifying the (1) cavity and (2) fault type from C100-type cryomodules at the Thomas Jefferson National Accelerator Facility (Jefferson Lab), thereby replacing the time-consuming efforts of a subject matter expert. Superconducting radio-frequency (SRF) cavity trips represent a significant source of accelerator downtime. Real-time – rather than post-mortem – identification of the offending cavity and classification of the fault type would give control room operators valuable feedback for corrective action planning. The anticipated benefit is increased beam-on-target time for users and provides performance metrics that can be used to improve future cavity designs. A series of 17 RF signals are recorded for each of the 8 cavities in a C100 cryomodule every time a cavity trips. These time-series signals are written to file using a specially designed data acquisition system. The dataset represents fault events recorded during Continuous Electron Beam Accelerator Facility (CEBAF) beam operations between January 18, 2019 and March 9, 2020. The following filtering steps were applied to collected data; (1) only 4 of the 17 signals per cavity are retained (GMES, GASK, CRFP, DETA2) (2) only events with data from each of the eight cavities in the cryomodule are kept, (3) only events that were sampled at 5 kHz were kept, (4) events from cryomodule 0L04 were neglected, (5) events occurring between February 4, 3PM and February 5, 12PM were neglected. As a result of preprocessing, the dataset is comprised of 2,375 unique events. The full dataset is comprised of three files: features.csv, cavity_labels.csv, fault_labels.csv. Each instance in faults.csv includes a timestamp (“date_time”), a label for the cryomodule which experienced the trip (“zone_label”), and 192 features (“feature_1”, “feature_2”... “feature_192”). The features correspond to 6 autoregressive features for each of 4 signals per cavity for each of the 8 cavities (6 × 4 signals/cavity × 8 cavities/cryomodule = 192). To deal with the large variation of signal amplitudes, time-series standardization via the z-score (standard score) function was applied prior to computing the features. For each instance, there is an associated label for the (1) cavity which faulted first (cavity_labels.csv) and (2) the type of fault that caused the trip (fault_labels.csv). The cavity identification can take values of [0, 1, 2, 3, 4, 5, 6, 7, 8] and the fault type can take values of [‘Microphonics’, ‘Quench_100ms’, ‘Controls_Fault’, ‘E_Quench’, ‘Quench_3ms’, ‘Single_Cav_Turn_Off’ , ‘Heat_Riser_Choke’, ‘Multi_Cav_Turn_Off’].

43 PARTICLE ACCELERATORS↗

A spectral study of a radio-frequency plasma-generated flux of atomic oxygen

The active environment of a radio-frequency (RF) plasma generator, with and without low-pressure oxygen, has been characterized through the identification of emission lines in the spectral region from 250 to 900 nm. The environment is shown to be dependent on the partial pressure of oxygen and the power applied to the RF generator. Atomic oxygen has been found in significant amounts as well as atomic hydrogen and the molecular oxygen species O2((sup 1)Sigma). The only charged species observed was the singly charged molecular ion O2(+). With a polymer specimen in the plasma chamber, carbon monoxide was also observed. The significance of these observations with respect to previous studies using this type of generator to stimulate material degradation in space is discussed. The possibility of using these generators as atomic oxygen sources in the development of oxygen atom fluorescence sensors is explored.

Batten, Carmen E.↗

Method and Apparatus for Measuring Fluid Flow

The invention is a method and apparatus for monitoring the presence, concentration, and the movement of fluids. It is based on utilizing electromagnetic measurements of the complex permittivity of the fluids for detecting and monitoring the fluid. More particularly the apparatus uses one or more microwave probes which are placed at the locations where the measurements are to be made. A radio frequency signal is transmitted to the probe and the reflected signal is phase and amplitude detected at a rapid rate for the purpose of identifying the fluids, based on their dielectric constant at the probe. The apparatus can be used for multiple purposes including measures of flow rates, turbulence, dispersion, fluid identification, and changes in flow conditions of multiple fluids or multiple states of a single fluid in a flowline or a holding container. The apparatus includes a probe consisting of two electrical conductors separated by an insulator. A radio frequency signal is communicated to the probe and is reflected back from the portion of the probe exposed to the fluid. The radio frequency signal also provides a reference signal. An oscillator generates a second signal which combined with each of the reference signal and the reflected signal to produce signals of lower frequencies to facilitate filtering and amplifying those signals. The two signals are then mixed in a detector to produce an output signal that is representative of the phase and amplitude change caused by the reflection of the signal at the probe exposed to the fluid. The detector may be a dual phase detector that provides two such output signals that are in phase quadrature. A phase shifter may be provided for selectively changing the phase of the reference signal to improve the sensitivity of at least one of the output signals for more accurate readings and/or for calibration purposes. The two outputs that are in quadrature with respect to each other may be simultaneously monitored to account for drift errors. The output signals are digitized and provided to a computer at a sample rate which may be very high. The computer is operable to identify the fluid based on its complex permittivity as may be useful for identifying the flow rates, determining the fluid mixture ratio, detecting impurities in the fluid, and so forth. Novelty is believed to reside in the use of the real part of complex permittivity to measure small difference in permittivity of the fluid.

Arndt, G. Dickey↗

Radio frequency sensing and its innovative applications in diverse sectors: A comprehensive study

Recent advancements in radio frequency (RF) sensing technology can be attributed to the development of the Internet of Things (IoT), healthcare, RF-identification, and communication applications. RF sensing is a multidisciplinary research field that requires expertise in computing, electronics, and electromagnetics to cover all system features, including protocol development, antenna design, sensor integration, algorithm formulation, interconnection, data, and analytics. The overarching aim of this work is to present detailed information about RF technologies and their innovations and application diversity from the novel work carried out at CSI Lab1, together in one platform with an extensive survey. This study presents state-of-the art applications and RF sensing that include W-Fi, radar, and SDR and RFID-based sensing. A comprehensive survey and study of the advantages and limitations of each non-contact technology is discussed. Additionally, open research gaps have been identified as well. Decades of knowledge and experience have been put to use to meet new challenges and demands. The development and study of RF systems, IoT, RFID sensing, and research and deployment activities, are briefly discussed. The emerging research projects with industry, institutional research centers, and academic studies are also addressed. Finally, an outline of identified potential future research areas is provided, emphasizing opportunities and challenges.

47 OTHER INSTRUMENTATION↗

Laboratory millimeter and submillimeter spectra of HNO and DNO

The identification of interstellar molecular species via the detection of one spectral line has recently become subject to close scrutiny. The radical HNO falls into the class of interstellar molecules identified in this manner. To corroborate this identification, observation of additional spectral lines is necessary. In this paper, laboratory millimeter and submillimeter wave spectra of both HNO and DNO are reported in the frequency region 150-500 GHz. Based on these spectral line measurements, models for HNO and DNO have been constructed to yield accurate frequencies for all rotational transitions of these species below 500 GHz involving J values smaller than 10. The spectral lines can be utilized by radio astronomers to confirm the identification of interstellar HNO and to search for interstellar DNO.

Sastry, K. V. L. N.↗

Addressee Errors in ATC Communications: The Call Sign Problem

Communication errors involving aircraft call signs were portrayed in reports of 462 hazardous incidents voluntarily submitted to the ASRS during an approximate four-year period. These errors resulted in confusion, disorder, and uncoordinated traffic conditions and produced the following types of operational anomalies: altitude deviations, wrong-way headings, aborted takeoffs, go arounds, runway incursions, missed crossing altitude restrictions, descents toward high terrain, and traffic conflicts in flight and on the ground. Analysis of the report set resulted in identification of five categories of errors involving call signs: (1) faulty radio usage techniques, (2) call sign loss or smearing due to frequency congestion, (3) confusion resulting from similar sounding call signs, (4) airmen misses of call signs leading to failures to acknowledge or readback, and (5) controller failures regarding confirmation of acknowledgements or readbacks. These error categories are described in detail and several associated hazard mitigating measures that might be aken are considered.

Monan, W. P.↗

A Case Study in RFI at L-band Detected by SMAP

Even when radio frequency interference (RFI) is detected, very little is known about the sources of the interference. More information about the sources would facilitate the design of systems to deal with the interference. Reporting of interference by the RFI teams for SMAP and SMOS through international channels has resulted in a decrease in RFI and identification of several sources. Two such cases that have been identified in the USA and are reported here.

Radiometry↗

Investigating Low Loss Substrates for Improved Qubit Coherence Times

Superconducting qubits are sensitive to dielectric losses from substrates, making the identification, optimization, and preparation of low-loss materials essential for enhancing qubit coherence times. In this work, we utilize Nb superconducting radio-frequency (SRF) cavities as a high-precision measurement tool to study the dielectric loss tangent of substrates with parts-per-billion sensitivity. This technique enables temperature- and field-resolved measurements, providing deep insights into the behavior of candidate materials such as sapphire and silicon. We explore the impact of substrate preparation techniques, examining how surface treatments and cleaning protocols influence dielectric loss. These studies highlight both the microscopic origins of loss in these substrates and the critical role of preparation methods, helping to identify key materials and processes that minimize dielectric loss, crucial for improving qubit performance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search and identification of transient and variable radio sources using MeerKAT observations: a case study on the MAXI J1820+070 field

ABSTRACT Many transient and variable sources detected at multiple wavelengths are also observed to vary at radio frequencies. However, these samples are typically biased towards sources that are initially detected in wide-field optical, X-ray, or gamma-ray surveys. Many sources that are insufficiently bright at higher frequencies are therefore missed, leading to potential gaps in our knowledge of these sources and missing populations that are not detectable in optical, X-rays, or gamma-rays. Taking advantage of new state-of-the-art radio facilities that provide high-quality wide-field images with fast survey speeds, we can now conduct unbiased surveys for transient and variable sources at radio frequencies. In this paper, we present an unbiased survey using observations obtained by MeerKAT, a mid-frequency (∼GHz) radio array in South Africa’s Karoo Desert. The observations used were obtained as part of a weekly monitoring campaign for X-ray binaries (XRBs) and we focus on the field of MAXI J1820+070. We develop methods to efficiently filter transient and variable candidates that can be directly applied to other data sets. In addition to MAXI J1820+070, we identify four likely active galactic nuclei, one source that could be a Galactic source (pulsar or quiescent XRB) or an AGN, and one variable pulsar. No transient sources, defined as being undetected in deep images, were identified leading to a transient surface density of <3.7 × 10−2 deg−2 at a sensitivity of 1 mJy on time-scales of 1 week at 1.4 GHz.

Rowlinson, A. (ORCID:0000000211957022)↗

SRF cavity instability detection with machine learning at CEBAF

During the operation of the Continuous Electron Beam Accelerator Facility (CEBAF), one or more unstable superconducting radio-frequency (SRF) cavities often cause beam loss trips while the unstable cavities themselves do not necessarily trip off. The present RF controls for the legacy cavities report at only 1 Hz, which is too slow to detectfast transient instabilities during these trip events. These challenges make the identification of an unstable cavity out of the hundreds installed at CEBAF a difficult and time-consuming task. To tackle these issues, a fast data acquisition system (DAQ) for the legacy SRF cavities has been developed, which records the sample at 5 kHz. An unsupervised learning framework has been developed to identify anomalous SRF cavity behavior. We will discuss the present status of the DAQ system and our framework, along with recent successes in detecting anomalous cavity behavior. Overall, our method offers a practical solution for identifying unstable SRF cavities, contributing to increased beam availability and machine reliability.

Accelerator Physics↗

An X-ray and radio study of steep-spectrum radio sources. II - Four fields from a 22 MHz polar cap survey

Four fields containing radio sources with spectral indices greater than unity at low frequencies have been observed over a wide range of radio wavelengths and at X-ray wavelengths. For most of the steep-spectrum sources no optical identifications have been found to the detection limit of the Palomar Schmidt prints, even with the positional precision of about 1 arcsec from VLA maps. This implies that the associated galaxies or clusters lie at a great distance. X-ray emission was not detected from any of the steep-spectrum radio sources. In one case, an extended source appears to be a radio halo in an uncataloged cluster of galaxies at a redshift of 0.125, and it is suggested that this object is a promising candidate for the detection of inverse Compton X-rays, since it is not a high-luminosity source of thermal X-rays.

Dewdney, P. E.↗

Radio spectrum surveillance station

The paper presents a general and functional description of a low-cost surveillance station designed as the first phase of NASA's program to develop a radio spectrum surveillance capability for deep space stations for identifying radio frequency interference sources. The station described has identified several particular interferences and is yielding spectral signature data which, after cataloging, will serve as a library for rapid identification of frequently observed interference. Findings from the use of the station are discussed.

Hersey, D. R.↗

Distress Transmitter and Receiver

Identifying distress signals sent and received automatically. Radio transmitter and receiver designed to be used together for location and identification of persons, aircraft, or ships in distress. Modulation of transmitted signal characterized by unique combination of frequencies, repetition rates, and duty cycles, so type or identity of vehicle or person in distress ascertained from signal. Receiver operates manually and monitored aurally in conventional manner: also includes automatic tuning and monitoring features to assist operator in measuring modulation characteristics and in detecting weak signals. Transmitter generates signal characterized by timed sequence of modulating pulses. Receiver automatically locks onto signal and identifies it according to modulation characteristics.

Wren, Paul E.↗

Radio observations in the fields of COS-B gamma ray sources. IV - First quadrant sources

The field of five COS-B gamma-ray sources in the first galactic quadrant have been mapped using the Effelsberg radio telescope at several frequencies. Candidate objects as potential radio counterparts of gamma-ray sources are discussed in the light of current observations; however, mostly being due to the crowded nature of the radio fields, no clear identification has been possible.

Ozel, M. E.↗

A mysterious plasma wave emission and the determination of plasma densities in Neptune's inner magnetosphere

One of the strongest plasma wave signals observed during the Voyager 2 encounter with Neptune is a narrowband emission between 3.0 and 4.3 kHz that was detected over a period of roughly 2 hours around closest approach. The emission occurs below the electron cyclotron frequency and the low-frequency cutoff of the radio continuum radiation. Of the naturally occurring signals in the earth's auroral zone and in Jupiter's magnetosphere this emission most resembles trapped Z mode waves found near the left-hand cutoff frequency. Using this identification, a plasma density profile is obtained that is independent of the plasma temperature. These densities greatly exceed those measured by the plasma science instrument on Voyager but are lower than estimates based on other models of Neptunian plasma wave phenomenology. If this wave mode is not a natural emission, it might arise from an unusual interaction of the spacecraft with the cold, dense ambient plasma.

Moses, S. L.↗

Ultraviolet spectra of planetary nebulae. X - Physical conditions in the compact planetary nebula Sw St 1

Photoelectric visual and ultraviolet observations of the compact planetary nebula Sw St 1 are analyzed. The electron density, determined from the C III 1907/1909 A line ratio, is N(e) = (1.1 + or - 0.1) x 10 to the 5th/cu cm, consistent with the high emission measure and high critical frequency determined from observations of the thermal radio emission. The C/O abundance ratio in the nebula is found to be N(C)/N(O) = 0.72 + or - 0.1, i.e. the envelope is oxygen-rich, as suggested by the identification of the silicate feature in the 8-13 micron infrared spectrum. Difficulties remain in accurately determining the reddening constant to the nebula and its electron temperature.

Flower, D. R.↗

Low-frequency radio navigation system

A method of continuous wave navigation using four transmitters operating at sufficiently low frequencies to assure essentially pure groundwave operation is described. The transmitters are keyed to transmit constant bursts (1/4 sec) in a time-multiplexed pattern with phase modulation of at least one transmitter for identification of the transmitters and with the ability to identify the absolute phase of the modulated transmitter and the ability to modulate low rate data for transmission. The transmitters are optimally positioned to provide groundwave coverage over a service region of about 50 by 50 km for the frequencies selected in the range of 200 to 500 kHz, but their locations are not critical because of the beneficial effect of overdetermination of position of a receiver made possible by the fourth transmitter. Four frequencies are used, at least two of which are selected to provide optimal resolution. All transmitters are synchronized to an average phase as received by a monitor receiver.

Wallis, D. E.↗

Identification of radio emission from the Io flux tube

The identification of a specific Jovian decametric emission with the particular flux tube near the orbit of Io giving rise to it would substantially improve theoretical understandings of the relation of the Io flux tubes with the arc-like structures seen on time vs. frequency plots of decametric emissions observed by the Voyager spacecraft. The present paper shows how the instantaneous Io flux tube may be identified with particular emission features. It is demonstrated that the emissions designated Io caused emission (ICE) may be interpreted as representing sections of arc structures emitted by the interaction of Io with successive flux tubes. The model is capable of accounting for the change of displacement angle of the ICE structures as the sub-observed Jovian longitude changes. The identification permits the mapping of emissions onto the causative flux tubes for Jovian longitudes from 240 to 360 deg.

Riddle, A. C.↗