Search NASA⌕ Search

SEARCH · Search NASA

Results for “Raman data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Raman spectra of gaseous and solid N2F4

The Raman spectrum of gaseous N2F4 at a pressure of 760 Torr was recorded with a spectral slit width of 3 kaysers. Ten of the expected eleven fundamentals of the symmetric motions of both the gauche and trans isomers give rise to strongly polarized Raman lines. These new data require a reassignment of some of the fundamentals for both the C2 and C2h conformers. The Raman of the solid at 18 K was also recorded. Both conformers were found in the solid even after annealing the sample for 9 hr at a temperature of 101.6 K and 3 hr at a temperature of 106.8 K. Bands attributable to the gauche isomer became more intense relative to those for the trans isomer after several hours of annealing.

Durig, J. R.↗

Platform for Post-Processing Waveform-Based NDE

Signal- and image-processing methods are commonly needed to extract information from the waves, improve resolution of, and highlight defects in an image. Since some similarity exists for all waveform-based nondestructive evaluation (NDE) methods, it would seem that a common software platform containing multiple signal- and image-processing techniques to process the waveforms and images makes sense where multiple techniques, scientists, engineers, and organizations are involved. NDE Wave & Image Processor Version 2.0 software provides a single, integrated signal- and image-processing and analysis environment for total NDE data processing and analysis. It brings some of the most useful algorithms developed for NDE over the past 20 years into a commercial-grade product. The software can import signal/spectroscopic data, image data, and image series data. This software offers the user hundreds of basic and advanced signal- and image-processing capabilities including esoteric 1D and 2D wavelet-based de-noising, de-trending, and filtering. Batch processing is included for signal- and image-processing capability so that an optimized sequence of processing operations can be applied to entire folders of signals, spectra, and images. Additionally, an extensive interactive model-based curve-fitting facility has been included to allow fitting of spectroscopy data such as from Raman spectroscopy. An extensive joint-time frequency module is included for analysis of non-stationary or transient data such as that from acoustic emission, vibration, or earthquake data.

Roth, Don J.↗

Decoding the shift-invariant data: applications for band-excitation scanning probe microscopy *

A shift-invariant variational autoencoder (shift-VAE) is developed as an unsupervised method for the analysis of spectral data in the presence of shifts along the parameter axis, disentangling the physically-relevant shifts from other latent variables. Using synthetic data sets, we show that the shift-VAE latent variables closely match the ground truth parameters. The shift VAE is extended towards the analysis of band-excitation piezoresponse force microscopy data, disentangling the resonance frequency shifts from the peak shape parameters in a model-free unsupervised manner. The extensions of this approach towards denoising of data and model-free dimensionality reduction in imaging and spectroscopic data are further demonstrated. This approach is universal and can also be extended to analysis of x-ray diffraction, photoluminescence, Raman spectra, and other data sets.

36 MATERIALS SCIENCE↗

Leveraging Multiple Raman Excitation Wavelength Systems for Process Monitoring of Nuclear Waste Streams

Processing nuclear waste from sites such as Hanford is a significant environmental cleanup need while being a significant logistical challenge. Integration of process monitoring tools, that can provide in situ and real-time feedback about the process, can significantly alleviate needs to collect grab samples for process control and product characterization. Raman spectroscopy paired with chemometric analysis is one process monitoring tool that can provide chemical composition information on a large number of chemical targets in nuclear waste streams. However, methods to improve limits of detection as well as drop uncertainty in quantification are needed. Optimizing instrument specifications can achieve this, here this is demonstrated by comparing limits of detection for key analytes when using Raman systems with 671 nm, 532 nm, and 405 nm excitation wavelengths. Generally, limits of detection decease (allowing the measurement of lower salt concentrations) with decreasing wavelength. Similarly, data collection times and averaging were optimized. Finally, multiple chemometric modeling approaches were leveraged, including multiblock methods that combined data from all three Raman systems to simultaneously quantify targets with improved sensitivity.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Raman-Augmented Stratospheric-Ozone Lidar

Differential-absorption lidar (DIAL) system measures concentration of ozone in stratosphere augmented with subsystem measuring Raman scattering from nitrogen. One of number of DIAL systems used in long-term monitoring of stratospheric ozone. Raman scattering from nitrogen provides data to correct for effects of aerosols. Channels at wavelengths of 332 and 385 nm added to DIAL receiver to measure Raman backscattering from nitrogen molecules in stratosphere. Data-acquisition electronics sample photon counts at a rate of 250 MHz.

Mcdermid, I. Stuart↗

Third-order nonlinearities in molecular hydrogen - Two-photon resonance enhanced third-harmonic generation and Raman scattering

Effects of quantum mechanical interferences on third-order susceptibilities in molecules are studied. First principle calculations for molecular hydrogen are presented and shown to agree with results derived from experimental stimulated Raman gain and spontaneous Raman cross-section data. 10 percent third-harmonic conversion efficiency in H2 at 1 atm without phase matching should require a 150 MW per sq cm at 4.81 microns. As little as 5.9-MW power is sufficient when the beam is properly focused. Resonance Raman scattering (RRS) is proposed for experimentally investigating the interference effects, which tend to reduce the strength of third-order nonlinear susceptibilities.

Pan, C.-L.↗

Carbon fiber classification using raman spectroscopy

Carbon fiber characterization processes are described that include multi-condition Raman spectroscopy-based examination combined with multivariate data analyses. Methods are a nondestructive material characterization approach that can provide predictions as to carbon fiber bulk physical properties, as well as identification of unknown carbon fiber materials for quality control purposes. The framework of the multivariate analysis methods includes a principal component-based identification protocol including comparison of Raman spectral data from an unknown carbon fiber with a data library of multiple principal component spaces.

Houk, Amanda L.↗

The Use of Spontaneous Raman Scattering for Hydrogen Leak Detection

A fiber optic probe has been built and demonstrated that utilizes back scattered spontaneous Raman spectroscopy to detect and identify gaseous species. The small probe, coupled to the laser and data acquisition equipment with optical fibers, has applications in gaseous leak detection and process monitoring. The probe design and data acquisition system are described. Raman scattering theory has been reviewed and the results of intensity calculations of hydrogen and nitrogen Raman scattering are given. Because the device is in its developmental stage, only preliminary experimental results are presented here. Intensity scans across the rotational-vibrational Raman lines of nitrogen and hydrogen are presented. Nitrogen at a partial pressure of 0.077 MPa was detected. Hydrogen at a partial pressure of 2 kPa approached the lower limit of detectability with the present apparatus. Potential instrument improvements that would allow more sensitive and rapid hydrogen detection are identified.

Degroot, Wim A.↗

Design and Study of a LOX/GH2 Throttleable Swirl Injector for Rocket Applications

A LOX/GH2 swirl injector was designed for a 10:1 propellant throttling range. To accomplish this, a dual LOX (liquid oxygen) manifold was used feeding a single common vortex chamber of the swirl element. Hot-fire experiments were conducting for rocket chamber pressures from 80 to 800 psia at a mixture ratio of nominally 6.0 using steady flow, single-point-per-firing cases as well as dynamic throttling conditions. Low frequency (mean) and high frequency (fluctuating) pressure transducer data, flow meter measurements, and Raman spectroscopy images for mixing information were obtained. The injector design, experimental setup, low frequency pressure data, and injector performance analysis will be presented. C efficiency was very high (approximately 100%) at the middle of the throttle-able range with somewhat lower performance at the high and low ends. From the analysis of discreet steady state operating conditions, injector pressure drop was slightly higher than predicted with an inviscid analysis, but otherwise agreed well across the design throttling range. Analysis of the dynamic throttling data indicates that the injector may experience transient conditions that effect pressure drop and performance when compared to steady state results.

Greene, Christopher↗

Design and Study of a LOX/GH2 Throttleable Swirl Injector for Rocket Applications

A LOX/GH2 swirl injector was designed for a 10:1 propellant throttling range. To accomplish this, a dual LOX manifold was used feeding a single common vortex chamber of the swirl element. Hot-fire experiments were conducted for rocket chamber pressures from 80 to 800 psia at a mixture ratio of nominally 6.0 using steady flow, single-point-per-firing cases as well as dynamic throttling conditions. Low frequency (mean) and high frequency (fluctuating) pressure transducer data, flow meter measurements, and Raman spectroscopy images for mixing information were obtained. The injector design, experimental setup, low frequency pressure data, and injector performance analysis are presented. C* efficiency was very high (approx. 100%) at the middle of the throttleable range with somewhat lower performance at the high and low ends. From the analysis of discreet steady state operating conditions, injector pressure drop was slightly higher than predicted with an inviscid analysis, but otherwise agreed well across the design throttling range. Dynamic throttling of this injector was attempted with marginal success due to the immaturity of the throttling control system. Although the targeted mixture ratio of 6.0 was not maintained throughout the dynamic throttling profile, the injector behaved well over the wide range of conditions.

Greene, Christopher↗

Experimental/Analytical Characterization of the RBCC Rocket-Ejector Mode

The experimental/analytical research work described here addresses the rocket-ejector mode (Mach 0-2 operational range) of the RBCC engine. The experimental phase of the program includes studying the mixing and combustion characteristics of the rocket-ejector system utilizing state-of-the-art diagnostic techniques. A two-dimensional variable geometry rocket-ejector system with enhanced optical access was utilized as the experimental platform. The goals of the experimental phase of the research being conducted at Penn State are to: (a) systematically increase the range of rocket-ejector understanding over a wide range of flow/geometry parameters and (b) provide a comprehensive data base for evaluating and anchoring CFD codes. Concurrent with the experimental activities, a CFD code benchmarking effort at Marshall Space Flight Center is also being used to further investigate the RBCC rocket-ejector mode. Experiments involving the single rocket based optically-accessible rocket-ejector system have been conducted for Diffusion and Afterburning (DAB) as well as Simultaneous Mixing and Combustion configurations. For the DAB configuration, air is introduced (direct-connect) or ejected (sea-level static) into a constant area mixer section with a centrally located gaseous oxygen (GO2)/gaseous hydrogen (GH2) rocket combustor. The downstream flowpath for this configuration includes a diffuser, an afterburner and a final converging nozzle. For the SMC configuration, the rocket is centrally located in a slightly divergent duct. For all tested configurations, global measurements of the axial pressure and heat transfer profiles as well as the overall engine thrust were made. Detailed measurements include major species concentration (H2 O2 N2 and H2O) profiles at various mixer locations made using Raman spectroscopy. Complementary CFD calculations of the flowfield at the experimental conditions also provide additional information on the physics of the problem. These calculations are being conducted at Marshall Space Flight Center to benchmark the FDNS code for RBCC engine operations for such configurations. The primary fluid physics of interests are the mixing and interaction of the rocket plume and secondary flow, subsequent combustion of the fuel rich rocket exhaust with the secondary flow and combustion of the injected afterburner flow. The CFD results are compared to static pressure along the RBCC duct walls, Raman Spectroscopy specie distribution data at several axial locations, net engine thrust and entrained air for the SLS cases. The CFD results compare reasonably well with the experimental results.

Ruf, J. H.↗

Understanding the Hydronium Cation in the Solid State: A Study in Synthetic Hydronium Uranyl Phosphate and Arsenate Mineral Systems and Their Irradiation Stability

Here, we present neutron diffraction, electronic structure calculations, and optical vibrational spectroscopic characterization of hydronium uranyl phosphate (HUP), the synthetic analog of chernikovite ((H 3 O)(UO 2 )(PO 4 )·3H 2 O) to gain insight into structural features of the hydronium cation in the solid state. HUP crystallizes in P2 1 /c instead of previously reported P4/ncc 1 at room temperature and Pccn below 302 K. Lower symmetry was required due to hydronium and interstitial water positions within the structure. Crystallographic positions of hydronium cations determined from powder neutron diffraction data are bolstered by Raman and attenuated total reflectance infrared spectroscopic measurements and are further informed by density functional theory with phonon eigenvector analysis for spectral assignments. Finally, HUP and its arsenate analog (trogerite, (H 3 O)(UO 2 )(AsO 4 )·3H 2 O), (HUAs) were studied using He 2+ irradiation as an analog for α radiolysis to investigate the irradiation stability of these phases and the stability of hydronium cations in the solid state. Dose studies were employed wherein each sample was irradiated to 5, 10, 15, 25, and 50 MGy. Structural insight regarding irradiated materials is gained using optical vibrational spectroscopy and powder X-ray diffraction. Surprising irradiation stability of HUAs was found up to 50 MGy of dose, which may have important implications for understanding and modeling the geologic stability of legacy U.

actinides↗

Observation of momentum-dependent charge density wave gap in a layered antiferromagnet ${\textrm{Gd}}{\textrm{Te}}_{3}$

Charge density wave (CDW) ordering has been an important topic of study for a long time owing to its connection with other exotic phases such as superconductivity and magnetism. The RTe 3 (R = rare-earth elements) family of materials provides a fertile ground to study the dynamics of CDW in van der Waals layered materials, and the presence of magnetism in these materials allows to explore the interplay among CDW and long range magnetic ordering. Here, we have carried out a high-resolution angle-resolved photoemission spectroscopy (ARPES) study of a CDW material GdTe 3 , which is antiferromagnetic below ~ 12 K, along with thermodynamic, electrical transport, magnetic, and Raman measurements. Our ARPES data show a two-fold symmetric Fermi surface with both gapped and ungapped regions indicative of the partial nesting. The gap is momentum dependent, maximum along $\overline{Γ}$ - $\overline{Z}$ and gradually decreases going towards $\overline{Γ}$ - $\overline{Z}$. Our study provides a platform to study the dynamics of CDW and its interaction with other physical orders in two- and three dimensions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improved isotope-shift-based bounds on bosons beyond the Standard Model through measurements of the $^2$D$_{3/2} - ^2$D$_{5/2}$ interval in Ca$^+$

We perform high-resolution spectroscopy of the $3$d$~^2$D$_{3/2} - 3$d$~^2$D$_{5/2}$ interval in all stable even isotopes of $^A$Ca$^+$ (A = 40, 42, 44, 46 and 48) with an accuracy of $\sim$ 20 Hz using direct frequency-comb Raman spectroscopy. Combining these data with isotope shift measurements of the 4s$~^2$S$_{1/2} \leftrightarrow 3$d$~^2$D$_{5/2}$ transition, we carry out a King plot analysis with unprecedented sensitivity to coupling between electrons and neutrons by bosons beyond the Standard Model. Furthermore, we estimate the sensitivity to such bosons from equivalent spectroscopy in Ba$^+$ and Yb$^+$. Finally, the data yield isotope shifts of the 4s$~^2$S$_{1/2} \leftrightarrow 3$d$~^2$D$_{3/2}$ transition at 10 part-per-billion through combination with recent data of Knollmann et al (2019).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spatially Resolved Raman Spectroscopic Investigation of Uranyl Fluoride: A Case Study in the Importance of Instrument Optimization

Raman spectroscopy is an emerging technique for rapid and nondestructive analysis of nuclear materials for forensic and nonproliferation applications as it is a powerful tool for distinguishing multiple chemical forms of materials with similar stoichiometries. Recent developments in spectroscopic software have enabled rapid data collection with high-speed Raman spectroscopic mapping capabilities. However, some uranium-rich materials are susceptible to degradation in humid air and/or laser-induced phase transformations. To mitigate environmental or measurement-related sample degradation of potential samples of interest, we have taken a systematic approach to define optimized data collection parameters for high-throughput measurements of uranyl fluoride (UO 2 F 2 ), which is an important intermediate material in the nuclear fuel cycle. First, we systematically describe the influence of optical magnification (5× to 100×), laser power, and exposure time on obtained signal for identical particles of UO 2 F 2 and find that at low laser power and exposure times, comparable signal is obtained regardless of optical magnification. Second, we ensure sample integrity during data collection, and third, collect spectroscopic maps that employ optimized parameters to reduce the time required to obtain spatially resolved spectroscopic information. Reductions of 90% and 99% in measurement times are discussed as they relate to differences in resolving spectroscopic features of particles in identical mapping areas. Finally, during this work, we found that additional data processing options were needed and thus developed a customized Python script for importing, processing, analyzing, and visualizing Raman spectroscopic map data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Spectroscopic Study of Mars-analog Materials with Amorphous Sulfate and Chloride Phases: Implications for Detecting Amorphous Materials on the Martian Surface

The Chemistry and Mineralogy X-ray diffraction (XRD) instrument aboard the Curiosity rover consistently identifies amorphous material at Gale Crater, which is compositionally variable, but often includes elevated sulfur and iron, suggesting that amorphous ferric sulfate (AFS) may be present. Understanding how desiccating ferric sulfate brines affect the spectra of Martian material analogs is necessary for interpreting complex/realistic reaction assemblages. Visible and near-infrared reflectance (VNIR), mid-infrared attenuated total reflectance (MIR, FTIR-ATR), and Raman spectra, along with XRD data are presented for basaltic glass, hematite, gypsum, nontronite, and magnesite, each at three grain sizes (<25, 25–63, and 63–180 μm), mixed with ferric sulfate (+/–NaCl), deliquesced, then rapidly desiccated in 11% relative humidity or via vacuum. All desiccated products are partially or completely XRD amorphous; crystalline phases include starting materials and trace precipitates, leaving the bulk of the ferric sulfate in the amorphous fraction. Due to considerable spectral masking, AFS detectability is highly dependent on spectroscopic technique and minerals present. This has strong implications for remote and in situ observations of Martian samples that include an amorphous component. AFS is only identifiable in VNIR spectra for magnesite, nontronite, and gypsum samples; hematite and basaltic glass samples appear similar to pure materials. Sulfate features dominate Raman spectra for nontronite and basaltic glass samples; the analog material dominates Raman spectra of hematite and gypsum samples. MIR data are least affected by masking, but basaltic glass is almost undetectable in MIR spectra of those mixtures. NaCl produces similar FTIR-ATR and Raman features, regardless of analog material.

58 GEOSCIENCES↗

Direct Observation and Analysis of Low-Energy Magnons with Raman Spectroscopy in Atomically Thin NiPS 3

van der Waals (vdW) magnets have rapidly emerged as a fertile playground for fundamental physics and exciting applications. Despite the impressive developments over the past few years, technical limitations pose a severe challenge to many other potential breakthroughs. High on the list is the lack of suitable experimental tools for studying spin dynamics on atomically thin samples. Here, Raman scattering techniques are employed to directly observe the low-lying magnon (~1 meV) even in bilayer NiPS 3 . Further, the advantage is that it offers excellent energy resolutions far better on low-energy sides than most inelastic neutron spectrometers can offer. More importantly, with appropriate theoretical analysis, the polarization dependence of the Raman scattering by those low-lying magnons also provides otherwise hidden information on the dominant spin-exchange scattering paths for different magnons. By comparing with high-resolution inelastic neutron scattering data, these low-energy Raman modes are confirmed to be indeed of magnon origin. Because of the different scattering mechanisms involved in inelastic neutron and Raman scattering, this information is fundamental in pinning down the final spin Hamiltonian. This work demonstrates the capability of Raman spectroscopy to probe the genuine two-dimensional spin dynamics in atomically thin vdW magnets, which can provide insights that are obscured in bulk spin dynamics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Raman lidar measurements of Pinatubo aerosols over southeastern Kansas during November-December 1991

Raman lidar measurements over southeastern Kansas of stratospheric aerosols produced by the June 1991 eruptions of Mt. Pinatubo were made on 10 nights during November and December 1991. Both aerosol backscattering and extinction profiles were derived simultaneously from the lidar data since this system detects Raman scattering from nitrogen and oxygen as well as the backscattered light from aerosols and molecules. Aerosols scattering ratios greater than 3(at 351 nm) were measured on several nights. Peak aerosol concentrations were located between 19-22 km and varied significantly from night to night. Aerosol extinction/backscatter ratios computed from the lidar data and averaged over the altitude region of enhanced aerosol scattering between 15-25 km varied between 18-28 sr. Mie computations show these values to be consistent with scattering by aerosol particles with mode radii between 0.3 to 0.5 micron and that the ratios would increase to 40-65 sr at 694 nm. Aerosol optical thicknesses derived from the lidar extinction measurements at 351 nm varied between 0.04 and 0.06.

Ferrare, R. A.↗