Search NASA⌕ Search

SEARCH · Search NASA

Results for “Raman data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Real-Time Automated pH Control within Batch Processes Relying on Raman pH Measurement

Nuclear fission is an energy source that can provide consistent power with very low associated carbon emissions. However, management of the used nuclear fuel is an important aspect of the application of nuclear power. Recycling of useful components from used fuel is an attractive option, but this involves chemical processing of the fuel. Possible chemical separation technologies that might be used in this regard are sensitive to solution pH. Raman spectroscopy is a promising technique for monitoring the pH of solutions in real time. Classical pH probes are too fragile to be used in the harsh environments encountered in nuclear fuel processing. Raman probes are robust and can withstand these harsh environments to track pH. Coupled with chemometric analysis, the demonstration of the use of Raman spectroscopy to track and predict the pH in carboxylate-buffered systems is made possible. Utilizing this spectroscopy in conjunction with Programmable Logic Controllers mimics industrial control systems used in many modern industrial settings. This showcases a pragmatic approach toward leveraging Raman spectroscopy and chemometric model outputs as inputs for a real-time control system. The model to predict pH created by chemometrics proved to be successful in tracking pH. The optimal pH for TALSPEAK extraction of lanthanides and actinides from aqueous solution is known to proceed in a narrow pH range of around pH = 2.8 ± 0.1. This study uses Raman optical monitoring and automated control to return and maintain solution pH within this range after acid or base perturbations move the solution pH well outside this region. Root-mean-square errors show that pH changes measured using Raman spectroscopy on the batch process solution are reliably measured and used to automatically correct and maintain solution pH. Measurement of solution pH tracks favorably with electrochemical pH probe comparison measurements. As a result, the ability to showcase Raman spectroscopy paired with chemometrics analysis acts as a durable, better alternative data source compared to traditional pH probes to optimize the separation efficiency in the used nuclear fuel processing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

0BGRaman: Graph Network based Simulator for Forecasting Molecular Polarizability

This report presents the work performed under the GRaman project, sponsored by the PCSD LDRD Seed program. The project aimed at accelerating ab initio molecular dynamics simulation using Graph Networks. The Graph Network framework is a ML framework that has been successfully employed to simulate the dynamics of several physical systems: including water splashing in a container and flags moving with the wind. In this effort, we performed a data collection campaign for 3 different molecules of interest. We have built tools for preprocessing the trajectories obtained by simulating Raman Spectroscopy with NWChem and translating them into a suitable format for training. We have developed a training algorithm to train the Graph Network based simulators based on our data and developed a simulator that produces trajectories in the same NWChem format. While the tool has improved with each iteration of development and subsequent experiments, the current state of the tool does not allow to directly incorporate the technology within the NWChem framework because the trajectories produced by the tool are not yet accurate enough. However, the technology has proved to have good potential and it is certainly worth further research and development.

97 MATHEMATICS AND COMPUTING↗

Probing the decelerating trajectory of a Raman soliton using temporal reflection

Temporal reflection is a process where an optical pulse reflects off a moving boundary with different refractive indices across it. In a dispersive medium, this process creates a reflected pulse with a frequency shift that changes its speed. Such frequency shifts depend on the speed of the moving boundary. In this work, we propose and experimentally show that it is possible to probe the trajectory of the boundary by measuring the frequency shifts while changing the initial delay between the incident pulse and the boundary. We demonstrate this effect by reflecting a probe pulse off a short soliton, acting as a moving boundary that decelerates inside a photonic crystal fiber because of intrapulse Raman scattering. We deduce trajectory of the soliton from the measured spectral data for the reflected pulse.

47 OTHER INSTRUMENTATION↗

The SuperCam Instrument Suite on the NASA Mars 2020 Rover: Body Unit and Combined System Tests

The SuperCam instrument suite provides the Mars 2020 rover, Perseverance, with a number of versatile remote-sensing techniques that can be used at long distance as well as within the robotic-arm workspace. These include laser-induced breakdown spectroscopy (LIBS), remote time-resolved Raman and luminescence spectroscopies, and visible and infrared (VISIR; separately referred to as VIS and IR) reflectance spectroscopy. A remote micro-imager (RMI) provides high-resolution color context imaging, and a microphone can be used as a stand-alone tool for environmental studies or to determine physical properties of rocks and soils from shock waves of laser-produced plasmas. SuperCam is built in three parts: The mast unit (MU), consisting of the laser, telescope, RMI, IR spectrometer, and associated electronics, is described in a companion paper. The on-board calibration targets are described in another companion paper. Here we describe SuperCam’s body unit (BU) and testing of the integrated instrument. The BU, mounted inside the rover body, receives light from the MU via a 5.8 m optical fiber. The light is split into three wavelength bands by a demultiplexer, and is routed via fiber bundles to three optical spectrometers, two of which (UV and violet; 245–340 and 385–465 nm) are crossed Czerny-Turner reflection spectrometers, nearly identical to their counterparts on ChemCam. The third is a high-efficiency transmission spectrometer containing an optical intensifier capable of gating exposures to 100 ns or longer, with variable delay times relative to the laser pulse. This spectrometer covers 535–853 nm ( $105\text{--}7070~\text{cm}^{-1}$ Raman shift relative to the 532 nm green laser beam) with $12~\text{cm}^{-1}$ full-width at half-maximum peak resolution in the Raman fingerprint region. The BU electronics boards interface with the rover and control the instrument, returning data to the rover. Thermal systems maintain a warm temperature during cruise to Mars to avoid contamination on the optics, and cool the detectors during operations on Mars.Results obtained with the integrated instrument demonstrate its capabilities for LIBS, for which a library of 332 standards was developed. Examples of Raman and VISIR spectroscopy are shown, demonstrating clear mineral identification with both techniques. Luminescence spectra demonstrate the utility of having both spectral and temporal dimensions. Finally, RMI and microphone tests on the rover demonstrate the capabilities of these subsystems as well.

47 OTHER INSTRUMENTATION↗

Lattice structure and dynamics of sparse molecular crystals: OsO4 and RuO4

This dataset contains input and output files from DFT simulations used to reproduce the electronic and phonon calculations of bulk and molecular OsO₄ and RuO₄. The files include data from initial electronic structure and phonon calculations performed using different functionals: PBE, PBEsol, and vdW-DF-optB86b. The computed phonon frequencies are compared with Raman crystal and gas-phase frequencies from existing literature, while the calculated phonon density of states (PhDOS) is compared with experimental PhDOS data.

36 MATERIALS SCIENCE↗

Iraq/Afghanistan war lung injury reflects burn pits exposure

This descriptive case series retrospectively reviewed medical records from thirty-one previously healthy, war-fighting veterans who self-reported exposure to airborne hazards while serving in Iraq and Afghanistan between 2003 and the present. They all noted new-onset dyspnea, which began during deployment or as a military contractor. Twenty-one subjects underwent non-invasive pulmonary diagnostic testing, including maximum expiratory pressure (MEP) and impulse oscillometry (IOS). In addition, five soldiers received a lung biopsy; tissue results were compared to a previously published sample from a soldier in our Iraq Afghanistan War Lung Injury database and others in our database with similar exposures, including burn pits. We also reviewed civilian control samples (5) from the Stony Brook University database. Military personnel were referred to our International Center of Excellence in Deployment Health and Medical Geosciences, Donald and Barbara Zucker School of Medicine at Hofstra/Northwell under the auspices of Northwell IRB: 17-0140-FIMR Feinstein Institution for Medical Research “Clinicopathologic characteristics of Iraq Afghanistan War Lung Injury.” We retrospectively examined medical records, including exposure data, radiologic imaging, and non-invasive pulmonary function testing (MGC Diagnostic Platinum Elite Plethysmograph) using the American Thoracic Society (ATS) standard interpretation based on Morgan et al., and for a limited cohort, biopsy data. Lung tissue, when available, was examined for carbonaceous particles, polycyclic aromatic hydrocarbons (Raman spectroscopy), metals, titanium connected to iron (Brookhaven National Laboratory, National Synchrotron Light Source II, Beamline 5-ID), oxidized metals, combustion temperature, inflammatory cell accumulation and fibrosis, neutrophil extracellular traps, Sirius red, Prussian Blue, as well as polarizable crystals/particulate matter/dust. Among twenty-one previously healthy, deployable soldiers with non-invasive pulmonary diagnostic tests, post-deployment, all had severely decreased MEP values, averaging 42% predicted. These same patients concurrently demonstrated abnormal airways reactance (X5Hz) and peripheral/distal airways resistance (D5–D20%) via IOS, averaging – 1369% and 23% predicted, respectively. These tests support the concept of airways hyperresponsiveness and distal airways narrowing, respectively. Among the five soldiers biopsied, all had constrictive bronchiolitis. We detected the presence of polycyclic aromatic hydrocarbons (PAH)—which are products of incomplete combustion—in the lung tissue of all five warfighters. All also had detectable titanium and iron in the lungs. Metals were all oxidized, supporting the concept of inhaling burned metals. Combustion temperature was consistent with that of burned petrol rather than higher temperatures noted with cigarettes. All were nonsmokers. Neutrophil extracellular traps were reported in two biopsies. Compared to our prior biopsies in our Middle East deployment database, these histopathologic results are similar, since all database biopsies have constrictive bronchiolitis, one has lung fibrosis with titanium bound to iron in fixed mathematical ratios of 1:7 and demonstrated polarizable crystals. These results, particularly constrictive bronchiolitis and polarizable crystals, support the prior data of King et al. (N. Engl. J. Med. 365:222–230, 2011) Soldiers in this cohort deployed to Iraq and Afghanistan since 2003, with exposure to airborne hazards, including sandstorms, burn pits, and improvised explosive devices, are at high risk for developing chronic clinical respiratory problems, including: (1) reduction in respiratory muscle strength; (2) airways hyperresponsiveness; and (3) distal airway narrowing, which may be associated with histopathologic evidence of lung damage, reflecting inhalation of burned particles from burn pits along with particulate matter/dust. Non-invasive pulmonary diagnostic tests are a predictor of burn pit-induced lung injury

36 MATERIALS SCIENCE↗

Bubble Mass Transport Measurement in the Large-Scale Test Loops at Oak Ridge National Laboratory

Molten salts are complex fluids that incorporate multi-phase behavior depending on the chemistry and the physical properties of the entrained components. These components include the carrier salt, the actinide fuel, and fission, activation, and corrosion products, the concentrations of which depends on the burnup history of the salt. Radionuclide transport from the salt into the cover gas / off-gas system depends on volatility as predicted by thermochemistry, but data from the Molten Salt Reactor Experiment (MSRE) conducted in the late 1960s suggest that bubble formation and transport are also important. Anomalously high fractions of noble metals were found in the off-gas system and were attributed to transportation with parent salt aerosols and their association with rising noble gas bubbles. The prediction of such phenomena requires coupled neutronic, thermal hydraulic, and chemical equilibrium calculations, the framework of which is being developed within the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program supported by the US Department of Energy (DOE) Office of Nuclear Energy (NE). However, separate effects tests and models of experiments using tools such as SAM and Thermochimica can guide model developers through important processes. Conversely, model development guides the choice of experiments and systems to provide data that are relevant for validation. This report describes several experiments that tracked gas transport in molten salts, ranging from small-scale systems to large-scale loops. Gas transportation in a molten salt, LiCl-KCl, has been studied using the shadowgraph technique. Sensors such as residual gas analysis, Raman spectroscopy, and laser-induced breakdown spectroscopy have been tested for off-gas measurements. These data were used to interpret how the gases move through the upstream salt / cover gas and the interface between them. Differential pressure measurements were able to detect individual gas bubbles as they popped at the liquid–gas interface. Salt aerosols were collected on a cascade impactor. Their formation was also observed directly via the shadowgraph method, and most of these aerosols were launched ballistically into the cover gas. Fine mists could also be observed. Convection currents through the salt were visualized and can be used to calculate the thermophysical properties of the salt itself. The apparatuses described in this report and in a previous work (McFarlane et al. 2023) have been commissioned and are available for use in making further measurements of salt/surrogate fission product behavior. Novel approaches using neutron imaging are planned for the study of fluoride salts, which cannot be contained in quartz, so shadowgraph visualization is not available. Bubble transport in convective flow and in a slow-moving salt column are planned. The mobile laser-induced breakdown spectroscopy (LIBS) system is available for several applications, including iodine capture in a molten hydroxide scrubber, H2 transport though molten salts to complement Raman analysis, and online tracking of salt aerosol generation, transport, and deposition. This report summarizes the findings from FY24 and the plans for FY25. The work completes milestone M2AT-24OR0702013 of the DOE-NE Advanced Reactor Technology, Molten Salt Reactor Campaign, DOE-NE-5.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Classification and computation of extreme events in turbulent combustion

In the design of practical combustion systems, ensuring safety and reliability is an important requirement. For instance, reliably avoiding lean blowout, flame flashback or inlet unstart is critical for ensuring safe operation. Currently, the science of predicting such events is based on prior experience, limited modeling or diagnostic tools and purely statistical approaches. Even though computational and experimental tools for studying combustion devices have vastly advanced in the last three decades, the analysis of such failure events has not been pursued widely. While the use of data for model development and calibration is being widely accepted, the extension to failure events introduces numerous challenges. In particular, the focus here is on so-called data-poor problems, where the cost of generating data is extremely high and is not easily amenable to existing computational and experimental approaches. Data-poor problems are particularly relevant when related to extreme events (also called anomalous events) that can lead to catastrophic failure of the system. It is argued that transient events that describe such failure can have different causal mechanisms. To develop the scientific inference process, a classification of such problems is used to determine specific modeling paths as well as computational tools needed. Research opportunities in the emerging field of extreme event prediction are highlighted in order to identify critical and immediate needs.

97 MATHEMATICS AND COMPUTING↗

Graphite Intercalation Compounds Derived by Green Chemistry as Oxygen Reduction Reaction Catalysts

Precious group metal (PGM) catalysts such as Pt supported on carbon supports are expensive catalysts utilized for the oxygen reduction reaction (ORR) due to their unmatched catalytic activity and durability. As an alternative, PGM-free ORR electrocatalysts that offer respectable catalytic activity are being pursued. Most of the notable PGM-free catalysts are obtained either from a bottom-up approach synthesis utilizing nitrogen-rich polymers as building blocks, or from a top down approach, where nitrogen and metal moieties are incorporated to carbonaceous matrixes. The systematic understanding of the origin of catalytic activity for either case is speculative and currently employed synthesis techniques typically generate large amounts of hazardous waste such as acids, oxidizing agents, and solvents. Herein, for the first time, we investigate the catalytic activity of graphite-based materials obtained via intercalation strategies that minimally perturb the graphitic backbone. Here, our outlined approaches demonstrate initial efforts to not only elucidate the role of each element but also significantly reduce the use of hazardous chemicals, which remains a pressing challenge. Graphite intercalation compounds (GIC) were obtained using fewer steps and solvent-free processes. X-ray diffraction and Raman results confirm the successful intercalation of FeCl 3 between graphite layers. Electrochemical data shows that the ORR performance of FeCl 3 -intercalated GIC displays slight improvement where the onset potential reaches 0.77 V vs RHE in alkaline environments. However, expansion of the graphite and solvent-free incorporation of iron and nitrogen moieties resulted in a significant increase in ORR activity with onset potential to 0.89 V vs RHE, a maximum half-wave of 0.72 V vs RHE, and a limiting current of about 2.5 mA cm –2 . We anticipate that the use of near solvent-free processes that result in a high yield of catalysts along with the fundamental insight into the origin of electrochemical activity will tremendously impact the methodologies for developing next-generation ORR catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stability of the peroxide group in BaO 2 under high pressure

Alkaline earth metal peroxides are typical examples of ionic compounds containing polyanions. We herein report a stable BaO 2 phase at high pressure up to 130 GPa found via a first-principles computational structure searches and high-pressure experimental investigations. The identified monoclinic structure (space group C2/m) can be derived by sublattice distortions of Ba atoms and peroxide groups associated with the phonon mode softening of the lower-pressure Cmmm structure. Contrary to the previous expectation of polymerization of the peroxide group at elevated pressure, the new phase retains the peroxide group and interestingly exhibits an insulating behavior demonstrating an increase of the band gap under compression. Our synchrotron XRD measurements could not distinguish between Cmmm and C2/m BaO 2 definitively because the difference in XRD patterns is very subtle. However, our data do not show any sign of polymerization transition up to 120 GPa. Raman spectra of the O-O peroxide vibration show a small anomaly in frequency at 110 GPa, which is qualitatively similar to that predicted theoretically due to the Cmmm to C2/m phase transition thus supporting the predicted transformation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evaluating Optical Techniques to Characterize Solid State Samples for the Pu-238 Supply Program

This report documents steps that have been taken to establish advanced characterization capabilities for solid-state samples to support the 238 Pu Supply Program. The program has already invested significantly in spectroscopy and online monitoring development for liquid processes. Many of the data, analytical methods, and equipment could also be leveraged for the analysis of Np/Pu oxides and Np pellets to help classify material properties and link them to operations. The techniques described in this work include diffuse reflectance spectroscopy (DRS), Raman spectroscopy, and laser-induced breakdown spectroscopy (LIBS). Each technique is sensitive to various chemical and/or elemental species and can provide complimentary information to more standard methods such as powder x-ray diffraction and scanning electron microscopy. These options are remotely deployable via fiber-optic cables. DRS and Raman spectroscopy are already approved for glove box and hot cell work, but LIBS requires US Department of Energy approval for incorporation. Raman spectroscopy does require laser shielding, which means that DRS is the easiest method to implement. However, each technique provides complimentary data, and the most robust sample characterization could be achieved when all three, among other methods, are harnessed together. This report documents some of the progress made testing these capabilities, some of the challenges, and next steps to optimize the technology and integration strategies.

07 ISOTOPE AND RADIATION SOURCES↗

Quantification of Hydrogen Isotopes Utilizing Raman Spectroscopy Paired with Chemometric Analysis for Application across Multiple Systems

On-line and real-time analysis of a chemical process is a major analytical challenge that can drastically change the way the chemical industry or chemical research operates. With in situ analyses, new and powerful understanding of chemistry can be gained; however, building robust tools for long-term monitoring faces many challenges that include compensating for instrument drift, instrument replacement, and sensor or probe replacement. Accounting for these changes by recollecting calibration data and rebuilding quantification models can be costly and time consuming. Here, in this study, methods to overcome these challenges are demonstrated with an application of Raman spectroscopy to monitoring hydrogen isotopes with varied speciation within dynamic gas streams. Specifically, chemical data science tools such as chemometric modeling are leveraged along with several examples of calibration transfer approaches. Furthermore, the optimization of instrument and sensors cell parameters for targeted gas phase analyses is discussed. While the particular focus on hydrogen is highly beneficial within the nuclear energy sector, mechanisms built and demonstrated here are widely applicable to optical spectroscopy monitoring in numerous other chemical systems that can be leveraged in other hazardous processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Probing the thermal decomposition of plutonium (III) oxalate with IR and Raman spectroscopy, X-ray diffraction, and electron microscopy

The thermal decomposition of Pu(III) oxalate was analyzed by Raman microspectroscopy, infrared spectroscopy, scanning electron microscopy, and powder X-ray diffraction. These data show that crystalline Pu 2 (C 2 O 4 ) 3 •9H 2 O progressively loses water and oxalate ligands as it is heated, which leads to a decrease in long-range lattice ordering, though minimal changes are observed in gross crystalline morphology. The onset of PuO 2 formation was observed between 200 - 250 °C. Thermal decomposition of oxalate ligands leads to the formation of CO 2 and plutonium oxalate-carbonate moieties, which had not been observed in previously published thermogravimetric measurements of Pu(III) oxalate. Formation of plutonium oxalate-carbonate moieties is believed to be associated with a change in the plutonium oxidation state from 3+ to 4+, which occurs prior to PuO 2 formation. The data provided herein demonstrate the rich spectroscopic nature of a rather underexplored, and technologically relevant, plutonium system. Ideally these results will further future investigations into the Pu(III) oxalate system both experimentally and computationally.

36 MATERIALS SCIENCE↗

Assessment of Extinction‐, Satellite‐, and Model‐Based Vertical Cloud Condensation Nuclei (CCN) Retrieval Methods Using Airborne CCN Measurements Over the Southern Great Plains

Abstract Accurate estimates of the vertical profile of cloud condensation nuclei (CCN) concentration are crucial to better quantify aerosol‐cloud interactions. We assessed the correlation between the vertical CCN concentrations obtained from extinction‐, satellite‐, and model‐based retrieval methods and airborne CCN concentrations collected at 0.24% supersaturation within the 3, 9, 27, and 81 km regions centered over the U.S. Department of Energy's Atmospheric Radiation Measurement User Facility Southern Great Plains (SGP) site during the spring and summer of 2016. The extinction profiles at a wavelength 355 nm were provided by the ground‐based Raman lidar. Our analysis showed moderate correlation between dry‐corrected extinction and airborne CCN data. We found the retrieved number concentration of CCN (RNCCN) method showed regression best‐fit slopes close to unity and consistent prediction errors for the majority of the data. The Lenhardt et al. (2023, https://doi.org/10.5194/amt‐16‐2037‐2023 ) method showed similar conclusions but only during spring, whereas the Mamouri and Ansmann (2016, https://doi.org/10.5194/acp‐16‐5905‐2016 ) method showed poor correlation. The Shinozuka et al. (2015, https://doi.org/10.5194/acp‐15‐7585‐2015 ) satellite‐based method exhibited reasonable agreement during summer but poor correlation during periods where both high (∼1,400 #/cm 3 ) and low (∼50 #/cm 3 ) airborne CCN concentrations were observed. The Copernicus Atmosphere Monitoring Service reanalysis modeled 3‐D CCN data set showed a moderate to weak positive correlation but performed poorly at high airborne CCN concentrations. Our analysis suggests the extinction‐based RNCCN method performed better than other methods across most observation periods under the diverse meteorological conditions observed at the SGP site.

54 ENVIRONMENTAL SCIENCES↗

Application of On-Line Monitoring and Real-Time Characterization of Low Level Waste Samples from Hanford Tanks

Waste and treatment stream characterization is an essential part of safe, efficient, and cost-effective processing of Hanford materials. The demand for materials characterization, including chemical, radionuclide, and physical attributes during waste management, transfer, and staging operations in the Hanford tank farms, is expected to significantly increase as the U.S. Department of Energy Office of River Protection (ORP) progresses toward Hanford waste treatment and immobilization. The application of on-line monitoring can greatly improve operation timeframes and reduce costs by providing real-time data and supporting the reduction of necessary grab sample collection. Recently, our team applied Raman online monitoring and chemometric modeling to the supernate of Hanford tank 241-AP-105, and demonstrated the quantitative measurement of nine analytes within this waste. Application of this method has been expanded to additional Hanford tank wastes, AW-102 and AP-107. The performance of the process monitoring instruments and the accuracy of the chemometric models will be assessed. On-line monitoring results will be compared to anion results determined from the current standard, ion-chromatographic and inductively coupled plasma mass spectrometry methods. Comparisons of both determined values and uncertainties of results will be presented. Results will be shared with personnel working on flowsheet interfaces for the Direct-Feed Low Activity Waste mission at Hanford.

Lines, Amanda M.↗

Application of On-Line Monitoring and Real-Time Characterization of Low Level Waste Samples from Hanford Tanks - 20380

Waste and treatment stream characterization is an essential part of safe, efficient, and cost-effective processing of Hanford materials. The demand for materials characterization, including chemical, radionuclide, and physical attributes during waste management, transfer, and staging operations in the Hanford tank farms, is expected to significantly increase as the U.S. Department of Energy Office of River Protection (ORP) progresses toward Hanford waste treatment and immobilization. The application of on-line monitoring can greatly improve operation time frames and reduce costs by providing real-time data and supporting the reduction of necessary grab sample collection. Recently, our team applied Raman online monitoring and chemometric modeling to the supernate of Hanford tank 241-AP-105, and demonstrated the quantitative measurement of nine analytes within this waste. Application of this method has been expanded to additional Hanford tank wastes, AW-102 and AP-107. The performance of the process monitoring instruments and the accuracy of the chemometric models will be assessed. On-line monitoring results will be compared to anion results determined from the current standard, ion-chromatographic and inductively coupled plasma mass spectrometry methods. Comparisons of both determined values and uncertainties of results will be presented. Results will be shared with personnel working on flowsheet interfaces for the Direct-Feed Low Activity Waste mission at Hanford. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Morphologically-Directed Raman Spectroscopy as an Analytical Method for Subvisible Particle Characterization in Therapeutic Protein Product Quality

Abstract Subvisible particles (SVPs) are a critical quality attribute of injectable therapeutic proteins (TPs) that needs to be controlled due to potential risks associated with drug product quality. The current compendial methods routinely used to analyze SVPs for lot release provide information on particle size and count. However, chemical identification of individual particles is also important to address root-cause analysis. Herein, we introduce Morphologically-Directed Raman Spectroscopy (MDRS) for SVP characterization of TPs. The following particles were used for method development: (1) polystyrene microspheres, a traditional standard used in industry; (2) photolithographic (SU-8); and (3) ethylene tetrafluoroethylene (ETFE) particles, candidate reference materials developed by NIST. In our study, MDRS rendered high-resolution images for the ETFE particles (> 90%) ranging from 19 to 100 μm in size, covering most of SVP range, and generated comparable morphology data to flow imaging microscopy. Our method was applied to characterize particles formed in stressed TPs and was able to chemically identify individual particles using Raman spectroscopy. MDRS was able to compare morphology and transparency properties of proteinaceous particles with reference materials. The data suggests MDRS may complement the current TPs SVP analysis system and product quality characterization workflow throughout development and commercial lifecycle.

Science & Technology - Other Topics↗

Advances in imaging, scattering, spectroscopy, and machine learning-aided approaches for multiscale characterization of cementitious systems

Recent progress in methods used in the multiscale characterization of cementitious systems is reviewed, focusing on advances in imaging, scattering, and spectroscopy. The review includes relevant applications and developments in machine learning and other data analytics approaches to enhance characterization. Developments in imaging using light and electron microscopy as well as x-ray (i.e., from synchrotron) methods are summarized. Updates include scanning electron microscopy (SEM), transmission electron microscopy (TEM), tomography, and holography. A critical overview of spectroscopy (e.g., MAS NMR, Raman) and scattering (e.g., neutron, x-ray, synchrotron x-ray) methods is provided, and the intersection of these with imaging is developed (e.g., Raman imaging). Additionally, the paper summarizes recent developments in and implementations of state-of-the-art machine-learning algorithms and data analytics methods for automated, systematic, and/or quantitative analyses of image data sets. The review considers but is not limited to the application of these methods for investigating the hydration and microstructure development of cement phases, low-carbon-footprint cements (e.g., limestone calcined clay cements, LC3), environmental interactions (e.g., ASR) and model systems. Finally, the present work provides a critical presentation of advances in characterization methods that link together the composition and multiscale structure of cementitious materials.

42 ENGINEERING↗