Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Corrigendum to “Cool Rooms for Indoor Heat Resilience: Evaluating Affordable Cooling Strategies in Heat-Stressed California Homes” [Building and Environment 287 (2026) 113877]

The authors regret an error in the acknowledgments section regarding the U.S. Department of Energy Solar Energy Technologies Office award number. The previously listed grant number, 2597–1625, was incorrect. The corrected acknowledgment should read: “This work was supported by the Assistant Secretary for Energy Efficiency and Renewable Energy, Office of Building Technologies of the United States Department of Energy (DOE), under Contract No. DE-AC02–05CH11231. This material is based upon work supported by the U.S. Department of Energy's Office of Energy Efficiency and Renewable Energy (EERE) under the Solar Energy Technologies Office Award Number DE-EE00040384. Any opinions, findings, and conclusions or recommendations expressed in this material are those of the author(s) and do not necessarily reflect the views of the Department of Energy.” The authors would like to apologise for any inconvenience caused.

Malik, Jeetika↗

Non-intrusive temperature measurements in the vicinity of a thermocouple using synchrotron x-ray fluorescence

A highly spatially resolved synchrotron x-ray fluorescence (XRF) thermometry technique has been used to map temperature fields around a 125 mu m type R thermocouple immersed in a stoichiometric premixed methane flame. The high spatial resolution of the XRF technique allowed temperatures to be measured close to the thermocouple and the impact of the thermocouple on the flame to be assessed. This paper discusses some of the nontrivial challenges of these measurements including the recovery of spectral features from the krypton fluorescent agent that are overlapped by those from the thermocouple metals at locations near the bead surface. The calculated temperatures from 1D premixed flame simulations are in excellent agreement with measurements along the centerline. The results show that the 125 mu m thermocouple induces minimal disturbances to the gas flow and any catalytic effects originating from the bare wires are also inconsequential. Here, the methodology has advanced to a stage where it enables comparisons between the gas temperature in the vicinity of the thermocouple and the actual thermocouple reading.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microbial spies and bloggers: programming cells to convert environmental information into discernible signals

Microbes regulate their dynamic behaviors using the chemical and physical characteristics of their environment. The ability of microbes to continuously convert this physicochemical information into biochemical information and to use organic matter in the environment as a power source makes these organisms attractive as chassis for building sensors. However, most biosensors have severe limitations when considering applications in hard-to-image settings like soils, sediments, and wastewater. Emerging technologies at the interface of biomolecular design, microbiome engineering, and synthetic biology offer new tools to program cells and communities as biosensors for these settings. Here, in this review, we describe innovations in biosensor outputs that are enabling new applications in complex environments, including reporters that are read out using electrochemical, gas chromatography, hyperspectral imaging, and next-generation sequencing methods. We also discuss computational advances that are accelerating the diversification of sensing components by mining metagenomics data for new transcriptional regulators and by designing allosteric protein switches that directly regulate reporter outputs using analytes. We highlight emerging opportunities for programming undomesticated microbes in communities to function as distributed sensors in the environment. Finally, we discuss the need for responsible biosensor development and to modernize regulatory frameworks to support evidence-based assessment of environmental biosensors.

analyte↗

Discovery of additional ancient genome duplications in yeasts

Whole-genome duplication (WGD) has had profound macroevolutionary impacts on diverse lineages, preceding adaptive radiations in vertebrates, teleost fish, and angiosperms. In contrast to the many known ancient WGDs in animals, and especially plants, we are aware of evidence for only four WGDs in fungi. The oldest of these occurred ∼100 million years ago (mya) and is shared by ∼60 extant Saccharomycetales species, including the baker’s yeast Saccharomyces cerevisiae. Notably, this is the only known ancient WGD event in the yeast subphylum Saccharomycotina. The dearth of ancient WGD events in fungi remains a mystery. Some studies have suggested that fungal lineages that experience chromosome and genome duplication quickly go extinct, leaving no trace in the genomic record, while others contend that the lack of known WGDs is due to an absence of data. Under the second hypothesis, additional sampling and deeper sequencing of fungal genomes should lead to the discovery of more WGD events. Coupling hundreds of recently published genomes from nearly every described Saccharomycotina species, with three additional long-read assemblies, we discovered three novel WGD events. Although the functions of retained duplicate genes originating from these events are broad, they bear similarities to the well-known WGD that occurred in the Saccharomycetales. In conclusion, our results suggest that WGD may be a more common evolutionary force in fungi than previously believed.

convergent evolution↗

Monitoring pipeline integrity of underground gas storage facilities using membrane-based electrochemical sensors

Effective monitoring of internal corrosion risk is crucial to ensuring the safety and longevity of natural gas pipeline infrastructure. While electrochemical sensors are commonly used to assess corrosion rates and corrosion indicators in aqueous fluids, they are rarely used in gas pipelines as these fluids lack the ionic conductivity needed for electrochemical measurements. The inclusion of ion-conductive membranes into electrochemical sensors can extend their functionality into humidified gas streams, providing critical information about emerging corrosion events that are common during withdrawal season in pipeline systems downstream from underground storage facilities. In parallel, new protective films, like those obtained through cold spray coating, are being developed to protect oil and gas pipelines and recover losses in structural integrity due to corrosion damage. Herein, we demonstrate how membrane-based electrochemical sensors (MBES) can be used to monitor fluid corrosivity by examining their response to changes in water content for a wide range of fluid compositions. It was found that MBES readings were highly sensitive to water content changes with membrane conductivity measurements varying from 10 –6 to 10 –1 S cm -1 , and corrosion rate measurements which varied from 10 –7 to 1 mm y -1 . Electron microscopy confirmed that the self-healing characteristics of metal coating films were still active despite their inclusion into an MBES probe. In conclusion, these findings indicate that membrane-based corrosion monitoring can be expanded to monitor coated-pipeline materials and provide early detection of emerging corrosion upsets relevant to underground gas storage facilities.

Electrochemical sensor↗

Regen: An object layout regenerator on large-scale production HPC systems

This article proposes an object layout regenerator called Regen which regenerates and removes the object layout dynamically to improve the read performance of applications. Regen first detects frequent access patterns from the I/O requests of the applications. Second, Regen reorganizes the objects and regenerates or preallocates new object layouts according to the identified access patterns. Finally, Regen removes or reuses the obsolete or regenerated object layouts as necessary. As a result, Regen accelerates access to objects by providing a flexible object layout. We implement Regen as a framework on top of Proactive Data Container (PDC) and evaluate it on Cori supercomputer, a production-scale HPC system, by using realistic HPC I/O benchmarks. The experimental results show that Regen improves the I/O performance by up to 16.92 × compared with an existing system.

Distributed file system↗

A split luciferase system for studying coronavirus Mpro dimerization in vitro and in living cells

The main protease enzyme (Mpro) of coronaviruses cleaves the viral polyprotein into functional units essential for virus replication. Prior work has demonstrated that Mpro functions as a homodimer. However, studies on the mechanism of dimerization have been challenging because the purified protease is mostly dimeric, dimerization-defective mutants lack proteolytic activity, and robust cell-based assays have yet to be reported. To enable work on Mpro dimerization, we have developed a quantitative luciferase-based SARS-CoV-2 (SARS2) Mpro biosensor that accurately reports protein dimerization in living cells and, upon purification, also in vitro. Co-transfection of cells with a construct expressing Mpro fused to the 18 kDa LargeBiT of luciferase (LgBiT) and a second construct with Mpro fused to the 1 kDa SmallBiT of luciferase (SmBiT) results in a reconstitution of luciferase activity in a dose-dependent manner that requires conserved residues within the dimerization interface. Proteolytic activity is dispensable for dimerization and, uniquely, a C145A catalytically inactive mutant exhibits enhanced dimerization signal likely due to lower cytotoxicity. Mpro enzymes from multiple different coronaviruses also dimerize in this system, indicating mechanistic conservation. Interestingly, this dimerization biosensor also provides a quantitative read-out of inhibitor-facilitated dimerization. Covalent SARS2 Mpro inhibitors such as nirmatrelvir cause a 3- to 5-fold increase in luciferase activity. Together with corroborating structural, biophysical, and molecular dynamics experiments, our studies support a model in which covalent Mpro inhibitors such as nirmatrelvir simultaneously block catalytic activity and induce allosteric stabilization of the dimeric complex.

SARS-CoV-2 main protease (Mpro/3CLpro)↗

Unsupervised multimodal fusion of in-process sensor data for advanced manufacturing process monitoring

Effective monitoring of manufacturing processes is crucial for maintaining product quality and operational efficiency. Modern manufacturing environments often generate vast amounts of complementary multimodal data, including visual imagery from various perspectives and resolutions, hyperspectral data, and machine health monitoring information such as actuator positions, accelerometer readings, and temperature measurements. However, fusing and interpreting this complex, high-dimensional data presents significant challenges, particularly when labeled datasets are unavailable or impractical to obtain. This paper presents a novel approach to multimodal sensor data fusion in manufacturing processes, inspired by the Contrastive Language-Image Pre-training (CLIP) model. We leverage contrastive learning techniques to correlate different data modalities without the need for labeled data, overcoming limitations of traditional supervised machine learning methods in manufacturing contexts. Our proposed method demonstrates the ability to handle and learn encoders for five distinct modalities: visual imagery, audio signals, laser position (x and y coordinates), and laser power measurements. By compressing these high-dimensional datasets into low-dimensional representational spaces, our approach facilitates downstream tasks such as process control, anomaly detection, and quality assurance. The unsupervised nature of our method makes it broadly applicable across various manufacturing domains, where large volumes of unlabeled sensor data are common. We evaluate the effectiveness of our approach through a series of experiments, demonstrating its potential to enhance process monitoring capabilities in advanced manufacturing systems. This research contributes to the field of smart manufacturing by providing a flexible, scalable framework for multimodal data fusion that can adapt to diverse manufacturing environments and sensor configurations. The proposed method paves the way for more robust, data-driven decision-making in complex manufacturing processes.

Contrastive Learning↗

Material-dependent photon ionizing radiation effects in Si and GaAs PIN diodes: A numerical investigation

We present a finite-element drift-diffusion-Poisson model in the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework to compare the radiation response of silicon (Si) and gallium arsenide (GaAs) PIN diodes under high-energy photon irradiation. The model solves coupled carrier continuity and Poisson’s equations with Shockley-Read-Hall recombination, and is verified against standard analytical J-V behavior. Using a simplified 1D geometry with ideal Ohmic contacts, we quantify device response under forward and reverse bias with a 100 MeV photon flux. Under forward bias, Si exhibits markedly greater radiation sensitivity than GaAs, including larger increases in current density, stronger local field and carrier-product perturbations, and higher recombination. Under reverse bias, GaAs shows larger radiation-induced photocurrent and broader current-density peaks near junctions, indicating an advantage for photodetection. Integrated steady-state recombination is consistently higher in Si across voltages. Under periodic photon pulses, GaAs produces higher-amplitude photoresponse and settles more rapidly than Si. These results highlight material-dependent trade-offs for radiation-tolerant, high-speed optoelectronics and provide guidance for selecting PIN architectures in aerospace, nuclear, and high-energy physics environments.

36 MATERIALS SCIENCE↗

Time-resolved synchrotron light source X-ray detection with Low-Gain Avalanche Diodes

Low Gain Avalanche Diodes (LGADs) represent the state-of-the-art in timing measurements and will instrument future timing detectors at the High Luminosity Large Hadron Collider (HL-LHC) experiments. While conceived as a sensor for charged particles, the intrinsic gain of LGADs makes it possible to detect low energy X-rays with good energy resolution and excellent timing (tens of picoseconds). Here, using the Stanford Synchrotron Radiation Lightsource (SSRL) at SLAC, several LGADs designs were characterized with energies from 5 to 35 keV. The SSRL provides 10 ps pulsed X-ray bunches separated by 2.1 ns intervals, and with an energy dispersion (ΔE/E) of 1 X 10 -4 . LGADs fabricated by Hamamatsu Photonics (HPK) and Brookhaven National Laboratory (BNL) with different thicknesses ranging from 20 µm to 50 µm and different gain layer designs were read out a two stage fast amplification circuit and digitized with a high bandwidth, high sampling rate oscilloscope. PIN devices from HPK were characterized as well. A systematic and detailed characterization of the devices’ energy linearity, resolution and timing resolution as a function of X-ray energy was performed for different biasing voltages at room temperature

Charge multiplication↗

Spectroscopic performance of Low-Gain Avalanche Diodes for different types of radiation

LGADs (Low-Gain Avalanche Diodes or Detectors) are a type of silicon Avalanche Photo-Diodes originally developed for the fast detection of minimum ionizing particles in high-energy physics experiments. Thanks to their fast timing performance, the LGAD paradigm enables detectors to accurately measure minimum ionizing particles with a timing resolution of a few tens of picoseconds. Such a performance is due to a thin substrate and the presence of a moderate signal gain. This internal gain of a few tens is enough to compensate for the reduced charge deposition in the thinner substrate and the noise of fast read-out systems. While LGADs are optimized for the detection of minimum ionizing particles for high-energy particle detectors, it is critical to study their performance for the detection of different types of particle, such as X-rays, gamma-rays, or alphas. In this paper, we evaluate the gain of three types of LGADs: two devices with different geometries and doping profiles fabricated by Brookhaven National Laboratory, and one fabricated by Hamamatsu Photonics with a different process. Since the gain in LGADs depends on the bias voltage applied to the sensor, pulse-height spectra have been acquired for bias voltages spanning from the depletion voltage up to the breakdown voltage. Finally, the signal-to-noise ratio of the generated signals and the shape of their spectra allow us to probe the underlying physics of the multiplication process.

47 OTHER INSTRUMENTATION↗

Characterization of a radiation detector based on opaque water-based liquid scintillator

Here, we present the characterization of a novel radiation detector based on an opaque water-based liquid scintillator. Opaque scintillators, also known as LiquidO, are made to be highly scattering, such that the scintillation light is effectively confined, and read out through wavelength-shifting fibers. The 1-liter, 32-channel prototype demonstrates the capability for both spectroscopy and topological reconstruction of point-like events. The design, construction, and evaluation of the detector are described, including modeling of the scintillation liquid optical properties and the detector’s response to gamma rays of several energies. A mean position reconstruction error of 4.4 mm for 1.6 MeV-equivalent events and 7.4 mm for 0.8 MeV-equivalent events is demonstrated using a simple reconstruction approach analogous to center-of-mass.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A flexible data acquisition system architecture for the Nab experiment

Here, the Nab experiment will measure the electron–neutrino correlation and Fierz interference term in free neutron beta decay to test the Standard Model and probe Beyond the Standard Model physics. Using National Instrument’s PXIe-5171 Reconfigurable Oscilloscope module, we have developed a data acquisition system that is not only capable of meeting Nab’s specifications, but flexible enough to be adapted in situ as the experimental environment dictates. The L1 and L2 trigger logic can be reconfigured to optimize the system for coincidence event detection at runtime through configuration files and LabVIEW controls. This system is capable of identifying L1 triggers at a rate of at least 1 MHz, while reading out a peak signal rate of approximately 2 GB/s. During the commissioning phase of the experiment, the system ran at a sustained readout rate of 400 MB/s of detector signal data originating from roughly 6 kHz L2 triggers, well within the peak performance of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The STAR Forward Silicon Tracker

The Forward Silicon Tracker (FST) is a pivotal component of the forward upgrade of the Solenoidal Tracker at RHIC (STAR), designed to discern hadron charge signs with a momentum resolution better than 30% for 0.2 < p T < 2GeV/c in the 2.5 < η < 4 pseudorapidity range. Its compact design features three disks along the beam direction, minimized material budget, and scattering effects. The FST uses Hamamatsu’s p-in-n silicon strip sensors with a double metal layer that enables efficient signal routing to the readout electronics, enhancing overall detector performance. The flexible hybrid boards, essential for the readout system, are constructed with Kapton and copper layers to optimize signal handling and power distribution. These boards connect silicon strips to analogue pipeline ASIC APV25-S1 chips, which read up to 128 channels each. A cooling system with nonconducting, volatile NOVEC 7200 coolant at 22.2 °C mitigates ASIC-generated heat. Furthermore, the FST enhances forward tracking performance at STAR as an integral part of the forward upgrade.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design and construction of the CMS Outer Tracker for the phase-2 upgrade

The High-Luminosity LHC (HL-LHC) is expected to deliver an integrated luminosity of 3000–4000 fb −1 over 10 years of operation with the peak instantaneous luminosity reaching about 5–7.5 × 1 0 34 cm −2 s −1 . During Long Shutdown 3, several components of the CMS detector will undergo major improvements, called Phase-2 upgrades, to be able to operate in the challenging environment of the HL-LHC. The current CMS tracker will be replaced. The Phase-2 Outer Tracker (OT) will have increased radiation tolerance, higher granularity, and the capability to handle higher data rates. Moreover, the OT will provide tracking information to the Level-1 trigger for the first time at a hadron collider, allowing trigger rates to be kept at a sustainable level without sacrificing physics potential. For this, the OT will be made of modules with two closely-spaced silicon sensors read out by front-end ASICs that can correlate hits in the two sensors to create short track segments, used in the Level-1 track finder. The modules come in two flavors: strip-strip and pixel-strip, containing different sensor configurations and multiple ASICs. This contribution presents the Phase-2 OT, the finalization of the OT module design, and the quality assurance and control procedures used to ensure that the modules fulfill both the specifications from the assembly steps as well as the proper communication among the ASICs.

Zoi, Irene [Fermilab] (ORCID:0000000257389446)↗

Characterization of the optical model of the T2K 3D segmented plastic scintillator detector unit cube

The magnetized near detector (ND280) of the T2K long-baseline neutrino oscillation experiment has been recently upgraded aiming to satisfy the requirement of reducing the systematic uncertainty from measuring the neutrino–nucleus interaction cross section, which is the largest systematic uncertainty in the search for leptonic charge-parity symmetry violation. A key component of the upgrade is SuperFGD, a 3D segmented plastic scintillator detector made of approximately 2,000,000 optically-isolated 1 cm 3 cubes. The SuperFGD cube unit shows promising optical performance, including a high light yield of about 40 photoelectrons (p.e.) per channel, a low cube-to-cube crosstalk rate below 3%, and a sub-nanosecond time resolution of 0.96 ns. By combining tracking and stopping power measurements of final state particles, this novel detector enables precise 3D-imaging of GeV neutrino interactions with reduced systematic uncertainties. A detailed Geant4 based optical simulation of the SuperFGD building block, i.e. a plastic scintillating cube read out by three wavelength shifting fibers, has been developed and validated with the different datasets collected in various beam tests. In this manuscript the description of the optical model as well as the comparison with data are reported.

Neutrino oscillations↗

Temperature-dependent calibration procedures for the silicon photomultiplier readout of the cosmic ray veto detector for the Mu2e experiment

The cosmic ray veto detector for the Mu2e experiment consists of scintillation bars embedded with wavelength-shifting fibers and read out by silicon photomultipliers (SiPMs). Here, in this manuscript, the calibration procedures of the SiPMs are described including corrections for the temperature dependence of their light yield. These corrections are needed as the SiPMs are not kept at a constant temperature due to the complexity and cost of implementing a cooling system on such a large detector. Rather, it was decided to monitor the temperature to allow the appropriate corrections to be made. The SiPM temperature dependence has been measured in a dedicated experiment and the calibration procedures were validated with data from production detectors awaiting installation at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A virtual Frisch-grid geometry-based CZT gamma detector for in-field radioisotope identification

Here, we present a Virtual Frisch-Grid geometry-based CZT gamma detector developed for identifying different radioisotopes over an energy range from a few keV up to 2 MeV, and useful for efficient characterization of CZT crystals. The detector is built with a 3 x 3 matrix of CZT crystals, each measuring approximately 6 mm x 6 mm x 15 mm. The charge generated within the sensor’s active volume is read out via an anode connected directly to the AVG3_Dev integrated circuit. A current signal induced by charge drift is collected on side pads of the crystals, enabling reconstruction of a 3D interaction position. This paper discusses the design, development, and performance of the standalone, mobile detector system, which integrates the AVG3_Dev readout IC developed at Brookhaven National Laboratory, a high-speed FPGA-based with per-channel digital signal processing, and embedded system capabilities. The device is compact, battery-powered, and supports wireless data streaming, making it suitable for field operations for radioisotope identification.

47 OTHER INSTRUMENTATION↗