Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reflection Efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Integrated patch and slot array antenna for terahertz quantum cascade lasers at 4.7 THz

Our work presents a slot and a patch array antenna at the front facet of a 4.7 THz quantum cascade laser as extractor, decreasing the facet reflectivity down to 2.6%. The resulting output power increases by a factor 2 and the slope efficiency by a factor 4. The simulated and the measured far-fields are in good agreement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Antireflective Multi‐Dielectric Metasurfaces Operating in the Visible

Abstract As increasingly more demanding photonics applications are brought on‐chip, more complex design solutions are employed to deliver enhanced performance: e.g., meta‐molecules, inverse‐designed freeform structures, and multilayer metasurfaces. Instead, this study introduces anti‐reflective metasurfaces fabricated in a single nanolithography step that follows deposition of multiple dielectrics onto a substrate. Anti‐reflective metasurfaces offer fundamentally better transmission efficiencies compared to conventional equivalents. Conventional and anti‐reflective metalenses, both fabricated in the Ta 2 O 5 /SiO 2 material platform for 461 nm operation, show an improvement in focusing efficiencies from ≈ 55% to ≈ 90% at low numerical apertures and from ≈ 35% to ≈ 65% at high numerical apertures. Simulations of ideal and imperfect metalenses indicate that anti‐reflective metasurfaces not only improve transmission at the design library level, but also reduce spurious diffraction and protect against higher‐order scattering.

Optics↗

Design of Thermophotovoltaic Cells for Optimal System Efficiency, Accounting for Photon Reuse from Front and Back Contacts

We develop a model showing how reflection from both the front and back contacts of thermophotovoltaic (TPV) cells affects the system efficiency. From this foundation we determine the design rules for front grids for TPV cells, and assess the consequences of those rules on cell design and system performance. We show that these design rules are different and more complex than the corresponding design rules for solar photovoltaic (PV) cells, and can lead to substantially different grid design and system performance than if the simpler solar PV design rules were used.

14 SOLAR ENERGY↗

Exploring the Saturation Levels of Stimulated Raman Scattering in the Absolute Regime

This Letter reports new experimental results that evidence the transition between the absolute and convective growth of stimulated Raman scattering (SRS). Significant reflectivities were observed only when the instability grows in the absolute regime. In this case, saturation processes efficiently limit the SRS reflectivity that is shown to scale linearly with the laser intensity, and the electron density and temperature. Such a scaling agrees with the one established by T. Kolber et al.[Phys. Fluids B 5, 138 (1993)] and B Bezzerides et al.[Phys. Rev. Lett. 70, 2569 (1993)], from numerical simulations where the Raman saturation is due to the coupling of electron plasma waves with ion waves dynamics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An X-band parabolic antenna based on gradient metasurface

We present a novel parabolic antenna by employing reflection gradient metasurface which is composed of a series of circle patches on a grounded dielectric substrate. Similar to the traditional parabolic antenna, the proposed antenna take the metasurface as a “parabolic reflector” and a patch antenna was placed at the focal point of the metasurface as a feed source, then the quasi-spherical wave emitted by the source is reflected and transformed to plane wave with high efficiency. Due to the focus effect of reflection, the beam width of the antenna has been decreased from 85.9° to 13° and the gain has been increased from 6.5 dB to 20.8 dB. Simulation and measurement results of both near and far-field plots demonstrate good focusing properties of the proposed parabolic antenna.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Projection screen having reduced ambient light scattering

An apparatus and method for improving the contrast between incident projected light and ambient light reflected from a projection screen are described. The efficiency of the projection screen for reflection of the projected light remains high, while permitting the projection screen to be utilized in a brightly lighted room. Light power requirements from the projection system utilized may be reduced.

47 OTHER INSTRUMENTATION↗

2D surface temperature measurement of plasma facing components with modulated active pyrometry

In nuclear fusion devices, such as Tore Supra, the plasma facing components (PFC) are in carbon. Such components are exposed to very high heat flux and the surface temperature measurement is mandatory for the safety of the device and also for efficient plasma scenario development. Besides this measurement is essential to evaluate these heat fluxes for a better knowledge of the physics of plasma-wall interaction, it is also required to monitor the fatigue of PFCs. Infrared system (IR) is used to manage to measure surface temperature in real time. For carbon PFCs, the emissivity is high and known (ε ~ 0.8), therefore the contribution of the reflected flux from environment and collected by the IR cameras can be neglected. However, the future tokamaks such as WEST and ITER will be equipped with PFCs in metal (W and Be/W, respectively) with low and variable emissivities (ε ~ 0.1–0.4). Consequently, the reflected flux will contribute significantly in the collected flux by IR camera. The modulated active pyrometry, using a bicolor camera, proposed in this paper allows a 2D surface temperature measurement independently of the reflected fluxes and the emissivity. Experimental results with Tungsten sample are reported and compared with simultaneous measurement performed with classical pyrometry (monochromatic and bichromatic) with and without reflective flux demonstrating the efficiency of this method for surface temperature measurement independently of the reflected flux and the emissivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and microwave test of an ultrawideband input/output structure for sheet beam travelling wave tubes

Broadband operation is of great importance for the applications of travelling wave tubes such as high-data communication and wideband radar. An input/output (I/O) structure operating with broadband property plays a significant role to achieve these applications. In this paper, a Y-type branch waveguide (YTBW) coupler and its improvements are proposed and utilized to construct an extremely wideband I/O structure to ensure the broadband operation for sheet beam travelling wave tubes (SB-TWTs). Cascaded reflection resonators are utilized to improve the isolation characteristic and transmission efficiency. Furthermore, to minimize the reflectivity of the port connected with the RF circuit, wave-absorbing material (WAM) is loaded in the resonator. Simulation results for the YTBW loaded with WAM predict an excellent performance with a 50.2% relative bandwidth for port reflectivity under −15 dB, transmission up to −1.5 dB, and meanwhile isolation under −20 dB. In addition, the coupler has a relatively compact configuration and the beam tunnel can be widened, which is beneficial for the propagation of the electrons. A Q-band YTBW loaded with two reflection resonators is fabricated and microwave tested. Vector network analyzer (VNA) measured results have an excellent agreement with our simulation, which verify our theoretical analysis and simulation calculation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prospective Evaluation of the Energy and CO 2 Emissions Impact of China’s 2010 – 2013 Efficiency Standards for Products

Since China introduced its first mandatory minimum energy performance standards (MEPS) for eight major household products in 1989, its MEPS program has expanded significantly to cover nearly 60 residential, industrial and commercial products. In June of 2012, the pace of standards development for new and revised standards was further accelerated with the launch of the national “100 Energy Efficiency Standards.” Initiatives. An unprecedented 21 MEPS were adopted by China from 2012 to 2013, compared to only 7 MEPS adopted from 2010 to 2011. The Chinese MEPS program now covers 15 products in the residential sector, 15 types of commercial and office equipment, 14 types of industrial equipment and 13 lighting products, making it one of the most comprehensive MEPS program in the world. This study provides an updated prospective evaluation of the potential energy and CO 2 impact of 23 of the 28 MEPS adopted by China from 2010 to 2013. This study updates a previous analysis (Zhou et al. 2011) by quantifying the additional potential energy and CO 2 reductions from the newest standards that have been adopted since 2010. The most recent actual and projected sales, usage, and efficiency data were collected for 14 product categories covered under 23 MEPS adopted between 2010 and 2013. Three scenarios are then used to quantify the energy and CO 2 reduction potential of the one-time implementation of these 23 MEPS, including a baseline counterfactual scenario, the actual MEPS scenario and a best available technologies efficiency scenario. The setting of the baseline efficiency is crucial to determining the savings potential of the new and revised MEPS and international best available technology efficiency levels, as it reflects the market average in the absence of MEPS. For this study, the average baseline is based on either the reported 2010 market-average efficiency if sales-weighted efficiency data is available for new product MEPS and selected products with revised MEPS, or the minimum efficiency requirement of the previous MEPS for products with revised MEPS from 2010 to 2013 that do not have sales-weighted efficiency data. Using sales-weighted efficiency data for the baseline help capture market transformation that has already occurred prior to the implementation of the MEPS, and can better differentiate the savings that are attributable to MEPS. The efficiency levels of best available technologies are taken from recent reviews of international commercially available best available technologies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A comparison of digital radiography systems in terms of effective detective quantum efficiency

Purpose: The purpose of this study is to compare digital radiography systems using the metric effective detective quantum efficiency (eDQE), which better reflects digital radiography imaging system performance under clinical operating conditions, in comparison with conventional metrics such as modulation transfer function (MTF), normalized noise power spectra (NNPS), and detective quantum efficiency (DQE). Methods: The eDQE was computed by the calculation of the MTF, the NNPS, the phantom attenuation and scatter, and estimation of x-ray flux. The physical characterization of the systems was obtained with the standard beam conditions RQA5 and RQA9, using the PA Chest phantom proposed by AAPM Report no. 31 simulating the attenuation and scatter characteristics of the adult human thorax. The MTF (eMTF) was measured by using an edge test placed at the frontal surface of the phantom, the NNPS (eNNPS) was calculated from images of the phantom acquired at three different exposure levels covering the operating range of the system (E{sub 0}, which is the exposure at which a system is normally operated, 1/3 E{sub 0}, and 3 E0), and scatter measurements were assessed by using a beam-stop technique. The integral of DQE (IDQE) and eDQE (IeDQE) was calculated over the whole spatial frequency range. Results: The eMTF results demonstrate degradation due to magnification and the presence of scattered radiation. The eNNPS was influenced by the grid presence, and in some systems, it contained structured noise. At typical clinical exposure levels, the magnitude of eDQE(0) with respect to DQE(0) at RQA9 beam conditions was 13%, 17%, 16%, 36%, and 24%, respectively, for Carestream DRX-1, Carestream DRX-1C, Carestream Direct View CR975, Philips Digital Diagnost VM, and GE Revolution XR/d. These results were confirmed by the ratio of IeDQE and IDQE in the same conditions. Conclusions: The authors confirm the robustness and reproducibility of the eDQE method. As expected, the DR systems performed better than the CR systems due to their superior signal-to-noise transfer characteristics. The results of this study suggest the eDQE method may provide an opportunity to more accurately assess the clinical performance of digital radiographic imaging systems by accounting for factors such as the presence of scatter, use of an antiscatter grid, and magnification and focal spot blurring effects, which are not reflected in conventional DQE measures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative analysis of optical and recombination losses in Cu(In,Ga)Se{sub 2} thin-film solar cells

Optical and recombination losses in a Cu(In,Ga)Se{sub 2} thin-film solar cell with a band gap of 1.36–1.38 eV are theoretically analyzed. The optical transmittance of the ZnO and CdS layers through which the radiation penetrates into the absorbing layer is determined. Using optical constants, the optical loss caused by reflection at the interfaces (7.5%) and absorption in the ZnO and CdS layers (10.2%) are found. To calculate the recombination loss, the spectral distribution of the quantum efficiency of CdS/CuIn{sub 1–x}Ga{sub x}Se{sub 2} is investigated. It is demonstrated that, taking the drift and diffusion components of recombination at the front and rear surfaces of the absorber into account, the quantum efficiency spectra of the investigated solar cell can be analytically described in detail. The real parameters of the solar cell are determined by comparing the calculated results and experimental data. In addition, the losses caused by the recombination of photogenerated carriers at the front and rear surfaces of the absorbing layer (1.8% and <0.1%, respectively), at its neutral part (7.6%), and in the space-charge region of the p–n heterojunction (1.0%) are determined. A correction to the parameters of Cu(In,Ga)Se{sub 2} is proposed, which enhances the charge-accumulation efficiency.

36 MATERIALS SCIENCE↗

Time-Varying Value of Energy Efficiency in Michigan

Quantifying the time-varying value of energy efficiency is necessary to properly account for all of its benefits and costs and to identify and implement efficiency resources that contribute to a low-cost, reliable electric system. Historically, most quantification of the benefits of efficiency has focused largely on the economic value of annual energy reduction. Due to the lack of statistically representative metered end-use load shape data in Michigan (i.e., the hourly or seasonal timing of electricity savings), the ability to confidently characterize the time-varying value of energy efficiency savings in the state, especially for weather-sensitive measures such as central air conditioning, is limited. Still, electric utilities in Michigan can take advantage of opportunities to incorporate the time-varying value of efficiency into their planning. For example, end-use load research and hourly valuation of efficiency savings can be used for a variety of electricity planning functions, including load forecasting, demand-side management and evaluation, capacity planning, long-term resource planning, renewable energy integration, assessing potential grid modernization investments, establishing rates and pricing, and customer service (KEMA 2012). In addition, accurately calculating the time-varying value of efficiency may help energy efficiency program administrators prioritize existing offerings, set incentive or rebate levels that reflect the full value of efficiency, and design new programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental study of Markstein number effects on laminar flamelet velocity in turbulent premixed flames

Effects of turbulent flame stretch on mean local laminar burning velocity of flamelets, u{sub n}, were investigated experimentally in an explosion vessel at normal temperature and pressure. In this context, the wrinkling, A{sub t}/A{sub l}, and the burning velocity, u{sub t}, of turbulent flames were measured simultaneously. With the flamelet assumption the mean local laminar burning velocity of flamelets, u{sub n}=u{sub t} x (A{sub t}/A{sub l}){sup -1}, was calculated for different turbulence intensities. The results were compared to the influence of stretch on spherically expanding laminar flames. For spherically expanding laminar flames the stretched laminar burning velocity, u{sub n}, varied linearly with the Karlovitz stretch factor, yielding Markstein numbers that depend on the mixture composition. Six different mixtures with positive and negative Markstein numbers were investigated. The measurements of the mean local laminar burning velocity of turbulent flamelets were used to derive an efficiency parameter, I, which reflects the impact of the Markstein number and turbulent flame stretch - expressed by the turbulent Karlovitz stretch factor - on the local laminar burning velocity of flamelets. The results showed that the efficiency is reduced with increasing turbulence intensity and the reduction can be correlated to unsteady effects. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated Spatial, Spectral, & Temporal Optical Reflectance System for Precision Occupancy & Location Sensing to Improve Building Energy Efficiency

Buildings consume approximately 35% of the electricity used in the U.S. and building owners can significantly reduce this energy use by providing services like heating, electrical power and lighting only when people are present. The ARPAe funded program titled “INTEGRATED SPATIAL, SPECTRAL, & TEMPORAL OPTICAL REFLECTANCE SYSTEM FOR PRECISION OCCUPANCY & LOCATION SENSING TO IMPROVE BUILDING ENERGY EFFICIENCY” demonstrates how a low cost sensor technology developed for measuring distances can be used to count and locate occupants with a high degree of precision with a very low error rates. This platform tells a building control system where occupants are located (but not who they are) so that energy consuming services can be provided only when the services are needed by building occupants. The original proof of concept involved using low cost, commercially available time-of-flight (TOF) sensors that measure distance, but the performance of these existing sensors was lacking, as they could not operate properly in the presence of sunlight, which blinded the simple TOF sensors and limited their utility in buildings. This project proposed a powerful new class of TOF sensors that used state-of-the-art integrated circuit (IC) fabrication processes that combined advanced photonics with conventional silicon chip circuitry for improved sensor performance. An equally important part of this project was to find ways to maximize occupant count and location accuracy while using the fewest number of sensors possible, in order to keep costs low. By using building blueprints to create digital twins of commercial building spaces, the team developed new algorithms to maximize occupant count and tracking accuracy by properly locating the minimum number of sensors at just the right spots in the building. This capability not only minimizes system costs but also simplified sensor installation and system commissioning. Our simulations of our sensor networks for a range of commercial floorplan designs demonstrated that our installed cost target of $0.08/sqft was attainable, though not fully demonstrated during the project. Finally, we noted that the TOF sensor concept could provide a valuable role in health and eldercare by tracking patients without the need for worn sensors and would be useful for fall detection and other patient safety metrics, including tracking healthcare/patient interactions. We feel that, when fully developed, this new class of sophisticated TOF sensors and support software will be a powerful new approach to improving building energy efficiency based on occupant centric control platforms and will also open new levels of patient safety in healthcare operations. To realize this potential, the team formed the Troy Sensor Company LLC to oversee licensing of the programs patents and continue to seek commercialization of this program’s activity sensing technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reflected Neutron Effects in Multiplicity Measurements of Bare HEU Assemblies

In a passive multiplicity characterization of highly enriched uranium (HEU) assemblies, fission chains are initiated by the characteristically fast neutrons from spontaneous fission of 238 U and 235 U as well as cosmic-ray spallation neutrons. Active interrogation of HEU uses other physical mechanisms for starting chains by inducing fission from high-energy neutrons, high-energy gamma-rays, delayed neutrons, or thermal neutrons. In all cases a contribution to the initiation of fission chains is the reflection of neutrons that initially escape the assembly and re-enter it after undergoing some scattering. The reflected neutron flux is geometry dependent and a combination of fast and thermal energies. The reflected thermal neutron contribution occurs hundreds of microseconds after the beginning of the fission chain and can be distinguished from the cosmic-ray spallation neutrons unrelated to fission chains, resulting in an HEU detection signature with high signal-to-noise. However, the reflected thermal neutron flux can be eliminated with an efficient thermal neutron absorber to investigate reflected neutron effects. In this paper, active and passive multiplicity measurements with HEU oxide assemblies of up to 16 kg of fuel pins and HEU metal assemblies of up to five 18 kg storage castings are reported. Each case demonstrates the differences in HEU signature when a borated thermal neutron absorber is present and shows the various detectable signatures with 3He proportional counters, the standard detector for differential die-way and neutron multiplicity measurements, and liquid scintillators, a detector capable of operating on the timescale of fission chains.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Optical and quantum efficiency analysis of (Ag,Cu)(In,Ga)Se2 absorber layers

(Ag,Cu)(In,Ga)Se2 thin films have been deposited by elemental co-evaporation over a wide range of compositions and their optical properties characterized by transmission and reflection measurements and by relative shift analysis of quantum efficiency device measurements. The optical bandgaps were determined by performing linear fits of (αhν)2 vs. hν, and the quantum efficiency bandgaps were determined by relative shift analysis of device curves with fixed Ga/(In+Ga) composition, but varying Ag/(Cu+Ag) composition. The determined experimental optical bandgap ranges of the Ga/(In+Ga) = 0.31, 0.52, and 0.82 groups, with Ag/(Cu+Ag) ranging from 0 to 1, were 1.19-1.45 eV, 1.32-1.56 eV, and 1.52-1.76 eV, respectively. The optical bowing parameter of the different Ga/(In+Ga) groups was also determined.

(Ag,Cu)(In,Ga)Se2↗

Steam Pressure-Reducing Station Safety and Energy Efficiency Improvement Project

The Facilities and Operations (F&O) Directorate is sponsoring a continuous process improvement (CPI) program. Its purpose is to stimulate, promote, and sustain a culture of improvement throughout all levels of the organization. The CPI program ensures that a scientific and repeatable process exists for improving the delivery of F&O products and services in support of Oak Ridge National Laboratory (ORNL) Management Systems. Strategic objectives of the CPI program include achieving excellence in laboratory operations in the areas of safety, health, and the environment. Identifying and promoting opportunities for achieving the following critical outcomes are important business goals of the CPI program: improved safety performance; process focused on consumer needs; modern and secure campus; flexibility to respond to changing laboratory needs; bench strength for the future; and elimination of legacy issues. The Steam Pressure-Reducing Station (SPRS) Safety and Energy Efficiency Improvement Project, which is under the CPI program, focuses on maintaining and upgrading SPRSs that are part of the ORNL steam distribution network. This steam pipe network transports steam produced at the ORNL steam plant to many buildings in the main campus site. The SPRS Safety and Energy Efficiency Improvement Project promotes excellence in laboratory operations by (1) improving personnel safety, (2) decreasing fuel consumption through improved steam system energy efficiency, and (3) achieving compliance with applicable worker health and safety requirements. The SPRS Safety and Energy Efficiency Improvement Project being performed by F&O is helping ORNL improve both energy efficiency and worker safety by modifying, maintaining, and repairing SPRSs. Since work began in 2006, numerous energy-wasting steam leaks have been eliminated, heat losses from uninsulated steam pipe surfaces have been reduced, and deficient pressure retaining components have been replaced. These improvements helped ORNL reduce its overall utility costs by decreasing the amount of fuel used to generate steam. Reduced fuel consumption also decreased air emissions. These improvements also helped lower the risk of burn injuries to workers and helped prevent shrapnel injuries resulting from missiles produced by pressurized component failures. In most cases, the economic benefit and cost effectiveness of the SPRS Safety and Energy Efficiency Improvement Project is reflected in payback periods of 1 year or less.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗