Search NASA⌕ Search

SEARCH · Search NASA

Results for “Rejection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Adaptive narrow-band interference rejection in a DS spread-spectrum intercept receiver using transform domain signal processing techniques

An intercept receiver which uses a transform-domain-processing filter is described. This receiver detects direct-sequence BPSK spread-spectrum signals in the presence of narrowband interference by employing adaptive narrowband interference rejection techniques. The improvement in the system performance over that of conventional detection techniques is shown by presenting the results of experimental measurements of probability of detection versus false alarm for an enhanced total power detector. Also presented are certain results corresponding to detection of the spectral lines generated at twice the carrier frequency, wherein the goal is often not just signal detection, but also carrier frequency estimation. The receiver uses one of two transform-domain-processing techniques for adaptive narrowband interference rejection. In the first technique, the narrowband interference is detected and excised in the transform domain by using an adaptive notch filter. In the second technique, the interference is suppressed using soft-limiting in the transform domain.

Gevargiz, John↗

A nonlinear optimization approach for disturbance rejection in flexible space structures

In this paper the design of an active control law for the rejection of persistent disturbances in large space structures is presented. The control system design approach is based on a deterministic model of the disturbances, with a model-based-compensator (MBC) structure, optimizing the magnitude of the disturbance that the structure can tolerate without violating certain predetermined constraints. In addition to closed-loop stability, the explicit treatment of state, control and control rate constraints, such as structural displacement, control actuator effort, and compensator time guarantees that the final design will exhibit desired performance characteristics. The technique is applied for the vibration damping of a simple two bay truss structure which is subjected to persistent disturbances, such as shuttle docking. Preliminary results indicate that the proposed control system can reject considerable persistent disturbances by utilizing most of the available control, while limiting the structural displacements to within desired tolerances. Further work, however, for incorporating additional design criteria, such as compensator robustness to be traded-off against performance specifications, is warranted.

Parlos, Alexander G.↗

Active disturbance rejection in large flexible space structures

The design of an active control law for the rejection of persistent disturbances, in large space structures is presented. The control system design approach is based on a deterministic model of the disturbances and it optimizes the magnitude of the disturbance that the structure can tolerate without violating certain predetermined constraints. In addition to closed-loop stability, the explicit treatment of state, control, and control rate constraints, such as structural displacement and control actuator effort, guarantees that the final design will exhibit desired performance characteristics. The technique is applied to a simple two-bay truss structure, and its response is compared with that obtained using a linear-quadratic-Gaussian/loop-transfer-recovery (LQG/LTR) compensator. Preliminary results indicate that the proposed control system can reject persistent disturbances of greater magnitude by utilizing most of the available control, while limiting the structural displacements to within desired tolerances.

Parlos, Alexander G.↗

Designing clutter rejection filters with complex coefficients for airborne pulsed Doppler weather radar

Ground clutter interference is a major problem for airborne pulse Doppler radar operating at low altitudes in a look-down mode. With Doppler zero set at the aircraft ground speed, ground clutter rejection filtering is typically accomplished using a high-pass filter with real valued coefficients and a stopband notch centered at zero Doppler. Clutter spectra from the NASA Wind Shear Flight Experiments of l991-1992 show that the dominant clutter mode can be located away from zero Doppler, particularly at short ranges dominated by sidelobe returns. Use of digital notch filters with complex valued coefficients so that the stopband notch can be located at any Doppler frequency is investigated. Several clutter mode tracking algorithms are considered to estimate the Doppler frequency location of the dominant clutter mode. From the examination of night data, when a dominant clutter mode away from zero Doppler is present, complex filtering is able to significantly increase clutter rejection over use of a notch filter centered at zero Doppler.

Jamora, Dennis A.↗

Development of advanced high temperature in-cylinder components and tribological systems for low heat rejection diesel engines, phase 1

Analysis and concept design work completed in Phase 1 have identified a low heat rejection engine configuration with the potential to meet the Heavy Duty Transport Technology program specific fuel consumption goal of 152 g/kW-hr. The proposed engine configuration incorporates low heat rejection, in-cylinder components designed for operation at 24 MPa peak cylinder pressure. Water cooling is eliminated by selective oil cooling of the components. A high temperature lubricant will be required due to increased in-cylinder operating temperatures. A two-stage turbocharger air system with intercooling and aftercooling was selected to meet engine boost and BMEP requirements. A turbocompound turbine stage is incorporated for exhaust energy recovery. The concept engine cost was estimated to be 43 percent higher compared to a Caterpillar 3176 engine. The higher initial engine cost is predicted to be offset by reduced operating costs due the lower fuel consumption.

Kroeger, C. A.↗

Heat Rejection Concepts for Brayton Power Conversion Systems

This paper describes potential heat rejection design concepts for closed Brayton cycle (CBC) power conversion systems. Brayton conversion systems are currently under study by NASA for Nuclear Electric Propulsion (NEP) applications. The Heat Rejection Subsystem (HRS) must dissipate waste heat generated by the power conversion system due to inefficiencies in the thermal-to-electric conversion process. Space Brayton conversion system designs tend to optimize at efficiencies of about 20 to 25 percent with radiator temperatures in the 400 to 600 K range. A notional HRS was developed for a 100 kWe-class Brayton power system that uses a pumped sodium-potassium (NaK) heat transport loop coupled to a water heat pipe radiator. The radiator panels employ a sandwich construction consisting of regularly-spaced circular heat pipes contained within two composite facesheets. Heat transfer from the NaK fluid to the heat pipes is accomplished by inserting the evaporator sections into the NaK duct channel. The paper evaluates various design parameters including heat pipe diameter, heat pipe spacing, and facesheet thickness. Parameters were varied to compare design options on the basis of NaK pump pressure rise and required power, heat pipe unit power and radial flux, radiator panel areal mass, and overall HRS mass.

Siamidis, John↗

Heat Rejection Concepts for Lunar Fission Surface Power Applications

This paper describes potential heat rejection design concepts for lunar surface Brayton power conversion systems. Brayton conversion systems are currently under study by NASA for surface power applications. Surface reactors may be used for the moon to power human outposts enabling extended stays and closed loop life support. The Brayton Heat Rejection System (HRS) must dissipate waste heat generated by the power conversion system due to inefficiencies in the thermal-to-electric conversion process. Space Brayton conversion system designs tend to optimize at efficiencies of about 20 to 25 percent with radiator temperatures in the 400 K to 600 K range. A notional HRS was developed for a 100 kWe-class Brayton power system that uses a pumped water heat transport loop coupled to a water heat pipe radiator. The radiator panels employ a tube and fin construction consisting of regularly-spaced circular heat pipes contained within two composite facesheets. The water heat pipes interface to the coolant through curved sections partially contained within the cooling loop. The paper evaluates various design parameters including radiator panel orientation, coolant flow path, and facesheet thickness. Parameters were varied to compare design options on the basis of H2O pump pressure rise and required power, heat pipe unit power and radial flux, radiator area, radiator panel areal mass, and overall HRS mass.

Siamidis, John↗

Pumped Fluid Loop Heat Rejection and Recovery Systems for Thermal Control of the Mars Science Laboratory

This viewgraph presentation reviews the heat rejection and heat recovery system for thermal control of the Mars Science Laboratory (MSL). The MSL mission will use mechanically pumped fluid loop based architecture for thermal control of the spacecraft and rover. The architecture is designed to harness waste heat from an Multi Mission Radioisotope Thermo-electric Generator (MMRTG) during Mars surface operations for thermal control during cold conditions and also reject heat during the cruise aspect of the mission. There are several test that are being conducted that will insure the safety of this concept. This architecture can be used during any future interplanetary missions utilizing radioisotope power systems for power generation.

mechanical pump fluid loop↗

Recent Advances in Power Conversion and Heat Rejection Technology for Fission Surface Power

Under the Exploration Technology Development Program, the National Aeronautics and Space Administration (NASA) and the Department of Energy (DOE) are jointly developing Fission Surface Power (FSP) technology for possible use in human missions to the Moon and Mars. A preliminary reference concept was generated to guide FSP technology development. The concept consists of a liquid-metal-cooled reactor, Stirling power conversion, and water heat rejection, with Brayton power conversion as a backup option. The FSP project has begun risk reduction activities on some key components with the eventual goal of conducting an end-to-end, non-nuclear, integrated system test. Several power conversion and heat rejection hardware prototypes have been built and tested. These include multi-kilowatt Stirling and Brayton power conversion units, titanium-water heat pipes, and composite radiator panels.

Mason, Lee↗

Heat Pipes and Heat Rejection Component Testing at NASA Glenn Research Center

Titanium-water heat pipes are being evaluated for use in the heat rejection system for space fission power systems. The heat rejection syst em currently comprises heat pipes with a graphite saddle and a composite fin. The heat input is a pumped water loop from the cooling of the power conversion system. The National Aeronautics and Space Administration has been life testing titanium-water heat pipes as well as eval uating several heat pipe radiator designs. The testing includes thermal modeling and verification of model, material compatibility, frozen startup of heat pipe radiators, and simulating low-gravity environments. Future thermal testing of titanium-water heat pipes includes low-g ravity testing of thermosyphons, radiation testing of heat pipes and fin materials, water pump performance testing, as well as Small Busine ss Innovation Research funded deliverable prototype radiator panels.

Sanzi, James L.↗

Optical Navigation Attitude Estimation and Calibration Performance Improvement using Outlier Rejection

Spacecraft optical navigation (OpNav) systems process a sequence of images of celestial bodies against a starfield background to estimate the position and velocity of the vehicle. While attitude is sometimes available from an onboard star tracker, it is often desirable to recognize the background stars in the OpNav images to better align the image. While many image processing algorithms exist for finding stars, efficiency and reliability remain key issues in the presence of extended bodies(e.g. the Moon, Earth), especially when attempting to solve the full lost-in-space problem. Some star outliers(stars identified with high residuals)could appear in the camera field of view, however using them in the attitude estimation or camera calibration would lead to less accurate results. Therefore, we require new and robust approaches to remove these outliers before any further processing. The emphasis of the work is on developing a simple and robust iterative technique to detect and reject the outliers which could be found in any frame during the lost in space attitude determination or during the camera calibration. These outliers are determined based on the residuals of the centroids of the detected stars and the corresponding location using the star catalog. If the residuals exceed a predetermined threshold value, the object will be detected as an outlier and will be removed before another attitude determination and calibration iteration is performed. The performance for both attitude determination and on-orbit camera calibration are improved by an almost two-fold increase in accuracy when applying this outlier rejection technique.

OpNav↗

The Effect of Transfer Line Length and Heat Rejection Temperature Distribution on the Thales Linear Pulse Tube (LPT) Cryocoolers

Four Thales LPT9310 and four Thales LPT9510 commercial off-the-shelf (COTS) cryocoolers were parametrically performance tested. The LPT9310 coolers had transfer lines of various lengths while the LPT9510 coolers all had the same transfer line geometry. The LPT9510 test results revealed unit-tounit thermodynamic performance variation, quantified the effect of compressor temperature on thermodynamic performance and quantified the heat flow distribution between the compressor and expander as a function of their temperature distribution. The LPT9310 test results revealed the optimal drive frequency as a function of transfer line length, quantified the effect of heat rejection temperature distribution on thermodynamic performance and enabled the development and verification of a thermodynamic performance prediction tool that accounted for cold tip temperature, heat lift, heat rejection temperature and transfer line length.

Rodriguez, J.I.↗

Production and Characterization of Additively Manufactured Radiator Panels with Integral Branching Heat Pipes for High-Temperature Heat Rejection

Emerging concepts for fission surface power and nuclear electric propulsion necessitate lightweight, mechanically robust, and thermally efficient heat rejection radiators. State-of-the-art intermediate-temperature (~400 K) composite radiator assemblies have been developed based on titanium-water heat pipes bonded to metal, graphite, and carbon-fiber-based panels. NASA has identified a need for new radiator concepts that can operate at even higher temperatures (500 – 600 K), minimize thermal resistances and thermal stress failures at bond interfaces, and approach areal densities of 2 – 3 kg m -2 . To meet these needs, our team is developing additively manufactured (AM) radiator panels with integral branching wicking heat pipe networks. Water is selected as the working fluid for this temperature range. Based on simulations and thermal vacuum experiments, these branching embedded heat pipe networks can efficiently distribute heat over panels for finned surface efficiencies of η f >70% at T H = 500 K input heat. This paper first presents laser powder-bed fusion AM strategies to produce embedded porous structures for wicking heat pipes in Inconel 718 and titanium alloys (commercially pure and Ti-6Al-4V alloys). Post-build chemical and thermal treatments are described that yield hydrophilic wicking surfaces for operation with water. Transient rate-of-rise experiments with water and acetone are reported that yield estimates for AM wick porosity (ϵ), permeability (K), and effective pore radius (r pore ). Based on the wick characterization results, small prototype radiator panels (75 × 125 mm) with integrated heat pipe networks were manufactured. Heat rejection performance data are presented from cold thermal vacuum testing, with heat input temperatures up to ~510 K. Future efforts will focus on improving heat pipe performance, optimizing radiator mass, and evaluating larger panels to assess scalability.

thermal management↗

Production and Characterization of Additively Manufactured Radiator Panels With Integral Branching Heat Pipes for High-Temperature Heat Rejection

Emerging concepts for fission surface power and nuclear electric propulsion necessitate lightweight, mechanically robust, and thermally efficient heat rejection radiators. State-of-the-art intermediate-temperature (~400 K) composite radiator assemblies have been developed based on titanium-water heat pipes bonded to metal, graphite, and carbon-fiber-based panels. NASA has identified a need for new radiator concepts that can operate at even higher temperatures (500 – 600 K), minimize thermal resistances and thermal stress failures at bond interfaces, and approach areal densities of 2 – 3 kg m -2 . To meet these needs, our team is developing additively manufactured (AM) radiator panels with integral branching wicking heat pipe networks. Water is selected as the working fluid for this temperature range. Based on simulations and thermal vacuum experiments, these branching embedded heat pipe networks can efficiently distribute heat over panels for finned surface efficiencies of η f >70% at T H = 500 K input heat. This paper first presents laser powder-bed fusion AM strategies to produce embedded porous structures for wicking heat pipes in Inconel 718 and titanium alloys (commercially pure and Ti-6Al-4V alloys). Post-build chemical and thermal treatments are described that yield hydrophilic wicking surfaces for operation with water. Transient rate-of-rise experiments with water and acetone are reported that yield estimates for AM wick porosity (ϵ), permeability (K), and effective pore radius ( r pore ). Based on the wick characterization results, small prototype radiator panels (75 × 125 mm) with integrated heat pipe networks were manufactured. Heat rejection performance data are presented from cold thermal vacuum testing, with heat input temperatures up to ~510 K. Future efforts will focus on improving heat pipe performance, optimizing radiator mass, and evaluating larger panels to assess scalability.

nuclear electric propulsion↗

Method and apparatus for analog pulse pile-up rejection

A method and apparatus for pulse pile-up rejection are disclosed. The apparatus comprises a delay value application constituent configured to receive a threshold-crossing time value, and provide an adjustable value according to a delay value and the threshold-crossing time value; and a comparison constituent configured to receive a peak-occurrence time value and the adjustable value, compare the peak-occurrence time value with the adjustable value, indicate pulse acceptance if the peak-occurrence time value is less than or equal to the adjustable value, and indicate pulse rejection if the peak-occurrence time value is greater than the adjustable value.

47 OTHER INSTRUMENTATION↗

Method and apparatus for analog pulse pile-up rejection

A method and apparatus for pulse pile-up rejection are disclosed. The apparatus comprises a delay value application constituent configured to receive a threshold-crossing time value, and provide an adjustable value according to a delay value and the threshold-crossing time value; and a comparison constituent configured to receive a peak-occurrence time value and the adjustable value, compare the peak-occurrence time value with the adjustable value, indicate pulse acceptance if the peak-occurrence time value is less than or equal to the adjustable value, and indicate pulse rejection if the peak-occurrence time value is greater than the adjustable value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rejection Sampling with Autodifferentiation -- Case study: Fitting a Hadronization Model

We present an autodifferentiable rejection sampling algorithm termed Rejection Sampling with Autodifferentiation (RSA). In conjunction with reweighting, we show that RSA can be used for efficient parameter estimation and model exploration. Additionally, this approach facilitates the use of unbinned machine-learning-based observables, allowing for more precise, data-driven fits. To showcase these capabilities, we apply an RSA-based parameter fit to a simplified hadronization model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

On-Detector Machine Learning for Beam-Induced Background Rejection at a 10 TeV Muon Collider

A 10 TeV Muon Collider is a compelling candidate for a future energy-frontier facility, offering unprecedented opportunities to explore the fundamental laws of particle physics. Muon decays in the collider ring produce intense beam-induced background (BIB) that can overwhelm detector occupancy and exceed readout bandwidth constraints. We investigate the potential of on-detector Machine Learning for BIB rejection in the vertex detector, exploiting pixel cluster shapes to distinguish background from collision products. We study three classes of lightweight neural-network architectures, and evaluate their implementation feasibility using high-level synthesis. Selected architectures achieve 88 to 90% data reduction at 99% signal efficiency, while requiring hardware resources compatible with potential ASIC implementation. These results demonstrate the potential of performing substantial BIB rejection directly in the pixel readout, providing a strategy for meeting the tracker readout requirements at a future Muon Collider.

Abadjiev, Daniel [Chicago U.]↗