Search NASA⌕ Search

SEARCH · Search NASA

Results for “Relative humidity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Delayed darkening of radiation-exposed radiochromic dye dosimeters

Experiments have verified the existence of considerable delayed darkening in FWT-60 dosimetry films that may, depending on relative humidity, last for several hours. The amount of delayed darkening depends very strongly on the relative humidity at which the films are equilibrated before irradiation. It is pointed out that the delayed darkening effect must be taken into account before any meaningful dosimetric measurements may be made using these nylon-based thin dosimetry films. The particular radiation-sensitive compound used in the FWT-60 films is the hexahydrosyethyl pararosanaline cyanide with the Dupont nylon resin, Elvamide 8061, which forms the host matrix of a solid-state solution.

Danchenko, V.↗

Mixed Layers and Satellite Retrievals

As part of the process to determine whether it is possible to retrieve boundary layer structure with the current sounding techniques, temperature retievals were performed for radiosonde profiles that showed temperature inversions. It was found that when temperature inversions exceed 8 to 10 C a retrieval will indeed show a temperature increase with height over a limited vertical distance. For weaker inversions retrieved temperatures are generally smoothly decreasing with height. It is, however, impossible to determine the actual mixed layer height from the retrievals. Whether the water vapor channels could be used in observing mixed layer structure was investigated. Temperature inversions are accompanied by significant drops in relative humidity. While this effect is very pronounced in parts of the trade wind regimes with relative humidity drops of up to 60%, it is widespread in other areas of the ocean as well. A simulation experiment was performed in which brightness temperatures were computed for smooth temperature and humidity profiles and compared with those computed from inversion profiles.

Boers, R.↗

Parameterizations of Depositional Growth of Cloud Ice in a Bulk Microphysical Scheme

Two aspects of the cloud ice parameterization in the Goddard Cumulus Ensemble Model cloud physics parameterization are examined: the conversion of cloud ice to snow by depositional growth, designated PSFI, and the saturation adjustment scheme. The original formulation of PSFI is shown to produce excessive conversion of cloud ice to snow because of an implicit assumption that the relative humidity is 100% with respect to water even though the air may actually be quite less humid. Two possible corrections to this problem are proposed, the first involving application of a relative humidity dependent correction factor to the original formulation of PSFI, and the second involving a new formulation of PSFI based on the equation for depositional growth of cloud ice. The sensitivity of these formulations of PSFI to the assumed masses of the ice particles is examined. Possible problems associated with using a saturation adjustment scheme for cloud ice are discussed and simulations of a squall line with and without application of the adjustment scheme for ice are compared.

Braun, Scott A.↗

Parameterizations of Depositional Growth of Cloud Ice in a Bulk Microphysical Scheme

The conversion of cloud ice to snow by depositional growth, designated P(sub SFI), in the Goddard Cumulus Ensemble Model cloud physics parameterization is examined. The original formulation of P(sub SFI) is shown to produce excessive conversion of cloud ice to snow because of an implicit assumption that the relative humidity is 100% with respect to water even though the air may actually be quite less humid. Two possible corrections to this problem are proposed, the first involving application of a relative humidity dependent correction factor to the original formulation of P(sub SFI), and the second involving a new formulation of P(sub SFI) based on the equation for depositional growth of cloud ice.

Braun, Scott A.↗

Space flight printed wiring board measling investigation

A flight printed wiring board (PWB) for a satellite project was observed to have a high incidence of measling. Other PWB's produced for the program by the same manufacturer did not exhibit the degree of measling as did the 'measle-prone' board. Measling susceptibility during hand soldering and measling effects on PWB insulation resistance were investigated for three production PWB's. Measling resistance was significantly different between the three boards: the 'worst' exhibited five times the number of measles as the 'best' board. 'Severe' measling (that which is likely to affect board reliability) did not exist on the 'best' board, even under extreme soldering conditions (399 degrees C for 12-15 sec.), whereas the 'worst' board showed an average of one 'severe' measle for every two pads under more normal soldering conditions (288-343 degrees C for 2-5 sec.). Both soldering time and temperature affected measling, with time having a slightly greater influence (2 percent versus 12 percent). Measling effects on PWB insulation resistance were inconclusive. These were evaluated by in situ resistance measurements on the same three boards at elevated temperature and humidity. The measured resistance for all three boards decreased for exposures greater than 50 degrees C and 50 percent relative humidity. The 'measle-prone' board showed a resistance decrease at only 25 degrees C and 50 percent relative humidity. However, no definitive difference was detected between measled and not-measled (control) samples. The boards evaluated were production boards, so the effect of interlayer traces connecting the plated-through holes was not controlled. It is likely the resistance measurements were over different volumes of PWB laminate, which would account for the widely varying resistances measured. Thermomechanical measurements on board laminate materials did not reveal any differences attributed to measling. Differences in glass transition temperature were significantly different when measured by DTA, but not by SDT. Laminate thermal expansion differences were significant for the 35 degrees C evaluations, but not for any higher temperatures.

Thomas, Walter B., III↗

Trajectory Simulations of Upper Tropospheric Humidity

We present comparisons of simulations of upper tropospheric humidity at 215 and 146 hPa with satellite measurements. Our model uses diabatic trajectories to advect water vapor from an initial condition of 100% relative humidity to the final state. The model does not allow parcels' relative humidity to exceed 100%, and in this way crudely incorporates condensation. We find that this simple model does a good job of simulating the observations. Sensitivity studies suggest that one must have realistic wind velocities in order to accurately simulate the humidity distribution; microphysical parameterizations seem to be less important. Comparisions between simulations using UKMO and NCEP horizontal winds will be discussed.

Dessler, A. E.↗

Anomalous swelling behavior of FM 5055 carbon phenolic composite

The swelling response of a typical carbon phenolic composite was measured in the three primary material directions. The data obtained sugrest that at low and high relative humidities the incremental increase in moisture absorption can be attributed primarily to the resin. At intermediate relative humidities, the water is moving largely into the carbonized fibers.

Stokes, E. H.↗

Measuring Moisture Levels in Graphite Epoxy Composite Sandwich Structures

Graphite epoxy composite (GEC) materials are used in the construction of rocket fairings, nose cones, interstage adapters, and heat shields due to their high strength and light weight. However, they absorb moisture depending on the environmental conditions they are exposed to prior to launch. Too much moisture absorption can become a problem when temperature and pressure changes experienced during launch cause the water to vaporize. The rapid state change of the water can result in structural failure of the material. In addition, heat and moisture combine to weaken GEC structures. Diffusion models that predict the total accumulated moisture content based on the environmental conditions are one accepted method of determining if the material strength has been reduced to an unacceptable level. However, there currently doesn t exist any field measurement technique to estimate the actual moisture content of a composite structure. A multi-layer diffusion model was constructed with Mathematica to predict moisture absorption and desorption from the GEC sandwich structure. This model is used in conjunction with relative humidity/temperature sensors both on the inside and outside of the material to determine the moisture levels in the structure. Because the core materials have much higher diffusivity than the face sheets, a single relative humidity measurement will accurately reflect the moisture levels in the core. When combined with an external relative humidity measurement, the model can be used to determine the moisture levels in the face sheets. Since diffusion is temperaturedependent, the temperature measurements are used to determine the diffusivity of the face sheets for the model computations.

Nurge, Mark↗

Occurrence of Ice Supersaturations, Ice Clouds, and Ternary Aerosols in the Arctic Lowermost Stratosphere

Relative humidity, aerosol concentration, and ice crystals all have important impacts on chemistry and radiative transfer in the lowermost stratosphere. In this study, we have combined SOLVE measurements with meteorological analyses to investigate the statistics of humidity, aerosols, and clouds in the arctic lower stratosphere. First, we will present a statistical analysis of relative humidity with respect to ice in the lowermost stratosphere, used on the DC-8 in situ measurements. We will show examples of ice supersaturation well within the stratosphere. Generally, these cases were associated with extremely low temperatures near the tropopause. Next, we will discuss the climatological occurrence frequency of tropopause temperatures low enough for ice saturation even with typically low stratospheric water vapor mixing ratios. Really, we will examine case studies of ice clouds observed in the lowermost stratosphere during SOLVE. We will discuss the possible origin of these clouds (i.e., precipitation from higher type II PSCs, injection of tropospheric air into the lower stratosphere, etc.).

Jensen, Eric↗

Emissions of an AVCO Lycoming 0-320-DIAD air cooled light aircraft engine as a function of fuel-air ratio, timing, and air temperature and humidity

A carbureted aircraft engine was operated over a range of test conditions to establish the exhaust levels over the EPA seven-mode emissions cycle. Baseline (full rich production limit) exhaust emissions at an induction air temperature of 59 F and near zero relative humidity were 90 percent of the EPA standard for HC, 35 percent for NOx, and 161 percent for CO. Changes in ignition timing around the standard 25 deg BTDC from 30 deg BTDC to 20 deg BTDC had little effect on the exhaust emissions. Retarding the timing to 15 deg BTDC increased both the HC and CO emissions and decreased NOx emissions. HC and CO emissions decreased as the carburetor was leaned out, while NOx emissions increased. The EPA emission standards were marginally achieved at two leanout conditions. Variations in the quantity of cooling air flow over the engine had no effect on exhaust emissions. Temperature-humidity effects at the higher values of air temperature and relative humidity tested indicated that the HC and CO emissions increased significantly, while the NOx emissions decreased.

Meng, P. R.↗

Sensible and latent heat flux estimates in Antarctica

The assumption has been made that the net annual contribution of water by the processes of deposition and sublimation to the Antarctic Ice Sheet is zero. The U.S. Antarctic Program started installing reliable automatic weather stations on the Antarctic Continent in 1980. The initial units were equipped to measure wind speed, wind direction, air pressure, and air temperature. During the 1983-1984 field season in Antarctica, three units were installed that measured a vertical air temperature difference between the nominal heights of 0.5 m and 3.0 m and relative humidity at a nominal height of 3 m. The measurements of the vertical air temperature difference and the relative humidity are the minimum required to estimate the sensible and latent heat fluxes to the air, while not exceeding the available energy requirements for the weather stations. The estimates of the net annual sublimation and deposition on the Ross Ice Shelf amount to 20 to 80 percent of the annual accumulation. We conclude that the assumption that annual sublimation and deposition are zero is not valid under Antarctic conditions.

Stearns, Charles R.↗

Evaluation of moisture barrier coatings on carbon-phenolic SRM nozzle materials

The carbon-phenolic composite ablative material used on the Solid Rocket Motor (SRM) nozzle is known to absorb moisture from the atmosphere. This could cause problems such as pocketing during firing. Several moisture barrier coatings were tested on the SRM nozzle material. Data are presented for six of the 12 coatings to be tested. The data were obtained from immersion of coated samples in an environmental chamber at 100 F and 100% relative humidity and by using a modified TGA (thermal gravimetric analysis) technique. The TGA technique involved allowing wet nitrogen (25 C, 80% relative humidity) to flow across a small sample at about 65 cu cm per minute while continually monitoring the weight increase. These preliminary results show Kel-F-800, a material supplied by 3M Corporation to be the better moisture barrier. A second task was to collect data on the relative absorption of water and kerosene into the carbon-phenolic SRM nozzle material. These data indicate that water absorbs into the nozzle material to a much greater extent than kerosene. Thus kerosene is the more likely solvent in which to make specific gravity measurements on the SRM nozzle material.

Mcnutt, Ronald C.↗

The time dependent growth of H2O-H2SO4 aerosols by heteromolecular condensation

A theory for the time-dependent growth of solution droplets by heteromolecular condensation is presented. The theory is applied to the growth of H2O-H2SO4 aerosols for relative humidities less than 100 per cent. Growth curves (droplet radius as a function of time) for different values of relative humidity are evaluated.

Hamill, P.↗

Water in the Martian regolith

The state of water in the Martian regolith is addressed. The water-ice phase composition, adsorption-desorption and evaporation phenomena, and brine compositions of six antarctic soils that are considered to be good terrestrial analogues of the Martian surface materials are examined. Experiments have shown that, for temperatures below freezing and relative humidities less than 100 percent, absorbed water and vapor are the only stable phases in the regolith. When the relative humidity reaches 100 percent, ice may form and coexist with the absorbed liquid phase. The absorbed water content declines with decreasing temperature; however, the presence of dissolved solutes can result in appreciable adsorbed liquid phase at temperatures as low as 210 K. Such properties may have a profound influence on martial geomorphology, physical and chemical weathering, and the exchange of water between the atmosphere and regolith.

Anderson, Duwayne M.↗

Hygrometer for Detecting Water in Partially Enclosed Volumes

A portable hygrometer has been devised to implement a pre-existing technique for detecting water trapped in partially enclosed volumes that may be difficult to reach and cannot be examined directly. The technique is based on the fact that eventually the air in such a volume becomes saturated or nearly so. The technique is straightforward: One measures the relative humidity and temperature of both the ambient air and a sample of air from the enclosed volume. If the relative humidity of the sample is significantly greater than that of the ambient air and/or if the sample is at or close to the dew point, then it can be concluded that water is trapped in the volume. Of course, the success of this technique depends on the existence of an access hole through which one can withdraw some air from the enclosed volume.

Youngquist, Robert C.↗

In-Situ and Remotely-Sensed Observations of Biomass Burning Aerosols at Doi Ang Khang, Thailand During 7-SEAS BASELInE 2015

The spring 2015 deployment of a suite of instrumentation at Doi Ang Khang (DAK) in northwestern Thailand enabled the characterization of air masses containing smoke aerosols from burning predominantly in Myanmar. Aerosol Robotic Network (AERONET) Sun photometer data were used to validate Moderate Resolution Imaging Spectroradiometer (MODIS) Collection 6 "Deep Blue" aerosol optical depth (AOD) retrievals; MODIS Terra and Aqua provided results of similar quality, with correlation coefficients of 0.93-0.94 and similar agreement within expected uncertainties to global-average performance. Scattering and absorption measurements were used to compare surface and total column aerosol single scatter albedo (SSA); while the two were well-correlated, and showed consistent positive relationships with moisture (increasing SSA through the season as surface relative humidity and total columnar water vapor increased), in situ surface-level SSA was nevertheless significantly lower by 0.12-0.17. This could be related to vertical heterogeneity and/or instrumental issues. DAK is at approximately 1,500 meters above sea level in heterogeneous terrain, and the resulting strong diurnal variability in planetary boundary layer depth above the site leads to high temporal variability in both surface and column measurements, and acts as a controlling factor to the ratio between surface particulate matter (PM) levels and column AOD. In contrast, while some hygroscopic effects were observed relating to aerosol particle size and Angstrom exponent, relative humidity variations appear to be less important for this ratio here. As part of the Seven South-East Asian Studies (7-SEAS) project, the Biomass-burning Aerosols & Stratocumulus Environment: Lifecycles and Interactions Experiment (BASELInE) was intended to probe physicochemical processes, interactions, and feedbacks related to biomass burning aerosols and clouds during the spring burning season (February-April) in southeast Asia (SEA).

biomass burning↗

Radiation Dry Bias of the Vaisala RS92 Humidity Sensor

The comparison of simultaneous humidity measurements by the Vaisala RS92 radiosonde and by the Cryogenic Frostpoint Hygrometer (CFH) launched at Alajuela, Cosla Rica, during July 2005 reveals a large solar radiation dry bias of the Vaisala RS92 humidity sensor and a minor temperature-dependent calibration error. For soundings launched at solar zenith angles between 10" and 30 , the average dry bias is on the order of 9% at the surface and increases to 50% at 15 km. A simple pressure- and temperature-dependent correction based on the comparison with the CFH can reduce this error to less than 7% at all altitudes up to 15.2 km, which is 700 m below the tropical tropopause. The correction does not depend on relative humidity, but is able to reproduce the relative humidity distribution observed by the CFH.

Vomel, H.↗

Indicator Devices for Detection of Trace Gaseous Hydrazines

The relatively recent decrease in the acceptable time-weighted-average for hydrazines from 100 parts-per-billion (ppb) to 10 ppb rendered many trace hydrazine detectors either insensitive or inaccurate. Development of a rapid detection method for hydrazines at the new 10-ppb concentration was necessary so that test area personnel could reliably assess airborne hydrazines concentrations of a potentially contaminated area prior to entry. The reduction of Au(III) to Au(0) by hydrazines is a well characterized reaction and application of the corresponding yellow to purple color change was selected as a potentially useful means for detection of trace hydrazines in air. Tests with small quantities of KAuCl4 deposited on a variety of substrates were conducted using verified sources of 1,1-dimethylhydrazine, methylhydrazine, and hydrazine at approximately 10 ppb in air. Substrates tested were glass fiber filter paper, glass beads, anion exchange resin (AuCl4- form), and diatomaceous earth. The most successful of these substrates were glass fiber filter paper and diatomaceous earth. The KAuC14 impregnated glass fiber filter paper appeared to be somewhat light sensitive so further tests were conducted using the diatomaceous earth substrate. KAuCl4 concentration, substrate particle size, and sampler configuration were evaluated. Based on these tests, the device selected for further evaluation was a 5mm OD by 50mm glass tube containing 0.02-0.03g of 45/60 mesh diatomaceous earth coated with 2 percent KAuCl4. When connected to a sampling pump, response of the device to changes in relative humidity, ambient light, and high levels of other fluids, which might also be found in a propellant test area, was evaluated. False positive responses were not detected for exposures to relative humidity changes from 10 to 80 percent, sunlight for greater than 10 minutes, or percent levels of ammonia, isopropyl alcohol, nitrogen dioxide, and hydrogen. In addition, body emissions did not produce a false positive response in view of potential application for use inside protective clothing. The device was shown to reliably detect less than 10 ppb of the hydrazines tested using a 10 to 20L sample followed by a 2 to 5 minute color development time. Some field tests were conducted in parallel with conventional acidic firebrick sorbent tubes. There was generally very good agreement between the devices and firebrick sorbent tubes when greater than 10 ppb of a hydrazine was present.

Dee, Lou A.↗