Search NASA⌕ Search

SEARCH · Search NASA

Results for “Residential Building”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

High-performance windows improve thermal survivability of occupants during cold snaps

Exposure to low indoor air temperature is a major contributor to temperature-related mortality during extreme cold events, especially when power outages disrupt operation of space heating systems. This study explores the impact of high-performance windows on the thermal resilience of residential buildings during extreme cold weather and grid power outages, as well as their long-term benefits through energy efficiency and reduced risk of property damage. Building performance simulations were conducted for reference residential buildings in three construction vintages and two major U.S. cities located in cold climate zones, considering two types of extreme cold events: short and severe, and long and milder. Our research found that even houses compliant with current energy codes struggle to maintain safe indoor temperatures for more than a few hours during power outages, necessitating rapid evacuations. High-performance windows can extend the thermal survivability time by up to 3.8 days within a 7-day cold snap and significantly reduce risk of bursting frozen water pipes, depending on the building’s insulation and infiltration level, cold event severity, and occupant vulnerability. This extended thermal safety time is crucial in scenarios where reduced mobility complicates emergency responses in senior housing. In addition to boosting thermal resilience, upgrading older homes with high-performance windows can reduce heating energy consumption by over 18% and cooling energy by 15%. Our findings highlight the need to incorporate thermal resilience assessments into new designs or major retrofits, including the use of typical and extreme weather scenarios and advanced technologies like high-performance windows.

Krelling, Amanda F↗

Terra-Populus v0.1: A Python Library for LandScan High-Definition Population Analysis and Modeling

The terra-populus library is designed for use by the LandScan HD technical team, offering a streamlined set of tools for generating and updating LandScan HD datasets from foundational building-level data, referred to as 'molecules,' provided by the building-level attribution team. This document serves as the primary technical documentation for terra-populus. Version 0.1 of the library includes the core modeling components necessary for LandScan HD production. It enables the generation of the LandScan HD Baseline dataset as well as corresponding confidence measures for the occupancy rates used. Parameters have been included for incorporating damaged building indicators and changes in population, to faciliate the creation of rapid updates for LandScan HD. Future iterations of terra-populus will introduce tools for creating a confidence index, and quantifying and propagating uncertainty, facilitating the creation of probabilistic LandScan HD outputs. This report provides an overview of the tools available in the library and the corresponding code implementations. One of the key advancements implemented in terra-populus is a redefinition of the atomic modeling unit for LandScan HD. Traditionally, the LandScan HD vector analytical framework has generated population estimates at the building sub-component (molecule) level. However, terra-populus adopts a building-level modeling approach. This shift is an operational decision aimed at aligning LandScan HD outputs with confidence measures, which are computed and validated at the building level (confidence measures are not included in this version of terra-populus, aside from those associated with the occupancy rates). Additional advancements to the LandScan HD modeling, as implemented by terra-populus, include a minimum population value parameter and an auto assignment of building floor counts. The population minimum value was implemented to prevent buildings and subsequent LandScan HD pixels that contained small values that may not rasterize in production. An 'auto' value has been included as a method for dealing with buildings lacking floor count information, where it is the average floor count of all other buildings with a residential building use type tag. The logic behind this is to remain consistent with the current logic employed for dealing with building use type null instances, where a null use type is defaulted to residential since it is the most common building type. The auto logic is intended to apply the most common building floor count of the most common type of buildings. The tools provided in terra-populus represent a significant step forward in improving the efficiency, reproducibility, and transparency of the LandScan HD modeling process. As the library evolves, it will continue to serve as a foundational resource for high-resolution population modeling.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Guide to Determining Climate Zone by County: Building America and IECC 2021 Updates

This report describes the climate zone designations used by the U.S. Department of Energy (DOE) Building America Program. The report aims to help residential building stakeholders identify the appropriate climate zone designation for each county in the United States, including Hawaii and Alaska. Identifying the correct climate zone is important for many activities including residential construction projects, code compliance, energy analysis and modeling, and other analytical activities where climate zones impact the energy and moisture performance of residential buildings. This report supersedes the previous Building America publication: Guide to Determining Climate Regions by County, published in 2010. This report reflects climate designations used by the International Code Council (ICC) in the 2021 versions of the International Energy Conservation Code (IECC), the International Residential Code (IRC), and other codes produced by ICC. The information provided here and associated data should be used for the most up-to-date information regarding climate zone designations in the United States.

2021 IECC↗

North Birmingham Housing Energy Baseline and Upgrade Strategies [Slides]

The community of North Birmingham, Alabama, participated in the Communities LEAP pilot program. As part of this technical assistance pilot, residential buildings, energy efficiency, and electrification were analyzed. This slide deck details the baseline analysis of residential buildings in the community and potential upgrade strategies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Technical Reference Documentation (V.3.3.0)

ResStock™ is the best-in-class building stock energy model for simulating and publishing energy use, utility bills, and greenhouse gas emissions from the residential sector of the U.S. ResStock answers two primary questions: (1) How is energy used in the U.S. residential building stock? and (2) What is the timeseries aggregate impact of energy technologies? Specifically, ResStock quantifies energy use across geographical locations, demographic groups, building types, fuels, end uses, and time of day. Additionally, it details the impact of efficiency or electrification measures: total changes in the amount of energy used by measure; where or in what use cases efficiency or electrification upgrade measures save energy; when or at what times of day savings occur; and which building stock or demographic segments have the biggest savings potential. This model, and the datasets it produces, are foundational to identifying pathways to affordable and equitable decarbonization of the U.S. residential buildings sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Validation of Air-Source Heat Pumps for Cold Climates

Heating energy is the largest end-use for U.S. residential buildings accounting for approximately one-third of residential building energy consumption (EIA 2021). Historically, air-source heat pumps have been limited to temperate climates because of subpar performance at extremely cold outdoor air temperatures. However, recent advances to cold-climate air-source heat pump technology, which typically rely on inverter-driven, variable-speed compressors and variable-speed fans, have significantly improved low-temperature heat pump performance enabling the technology to save energy for many homes in cold climates. The primary objective of this project was to measure in-field performance of centrally ducted, variable-capacity air-source heat pumps in cold climates to validate performance and develop field-based performance maps. The project focused on quantifying heat pump performance at cold temperatures. The sites identified for the study were primarily located in the Northwest United States since homes in the region tend to have all-electric space heating systems and high-efficiency heat pumps have been incentivized in the region for several years. NREL partnered with Ecotope, Inc., a small energy consulting firm located in Seattle, WA, for site recruitment, monitoring equipment installation, data quality management. All the sites included in the study had previously installed a high-efficiency, central heat pump system. One site was in a Denver, CO suburb, which was the only dual fuel heat pump in the study. We used airside and power measurements, collected at 5-second intervals, to quantify heat pump capacity, coefficient of performance (COP), and auxiliary heater energy consumption. We developed algorithms to automatically determine the heat pump operating mode including defrost and auxiliary heating operation. A whole-house thermal and duct audit was completed during the initial site visit to estimate winter heating loads and assess heat pump sizing. Whole-home heating design loads were calculated at ASHRAE 99% design temperatures and compared to manufacturer-reported maximum capacities to assess the heat pump sizing at each site.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Achieving 50% Energy Savings in Chicago Homes: A Case Study for Advancing Equity and Climate Goals

Since 2019, the National Renewable Energy Laboratory (NREL) and Elevate have collaborated to identify pathways to deep energy retrofits in Chicago's housing stock, document equity implications and co-benefits of this transition, and validate the findings by implementing retrofits in real Chicago homes. This document summarizes our analysis process to model advanced retrofit packages that lead to greater than 50% energy savings in Chicago homes. Based on these findings, we have also developed a roadmap with the City to guide implementation, and are deploying the recommended retrofit packages in real Chicago homes to realize these energy savings. This work was developed in collaboration with two key stakeholders - the City of Chicago and Commonwealth Edison (ComEd) - and funded by the U.S. Department of Energy (DOE). NREL's Residential Buildings team maintains the best-in-class ResStock™ energy model of the U.S. residential building stock. For this work, we calibrated ResStock to Chicago's unique local housing stock to accurately simulate energy use in Chicago homes both for current conditions and with various retrofit scenarios. We simulated a wide range of potential building retrofits covering all aspects of residential energy use and then grouped these into packages based on energy and utility bill savings. ResStock can model diverse building types and housing characteristics, so we're able to observe the range of outcomes that might occur when these upgrades are deployed across the entire housing stock. We can then estimate potential energy savings from an advanced retrofit program on Chicago's housing stock by comparing the modeled energy use before versus after a retrofit. This novel version of ResStock, calibrated to Chicago with data from Elevate, can help City officials, ComEd, and other partners plan for community-scale decarbonization via residential retrofits. Specifically, this work contributes the following project goals: Develop a building retrofit prioritization strategy for Chicago single-family and 2- to 4-unit buildings; Identify neighborhoods and home types that have the highest potential for savings from electrification; and Assess the impact of advanced building retrofits on energy use, utility bills, and CO2 emissions at the city and building level. Although this study is specific to Chicago, its methods and learnings are applicable across the United States. These findings are especially notable for heat pumps and electrification retrofits in cold climates.

building energy modeling↗

The role of building characteristics, demographics, and urban heat islands in shaping residential energy use

This study assesses the effects of residential building structure, socio-demographics, and ambient temperature conditions of a neighborhood to overall energy expenditures of a household. Using annual utility billing data, existing tax-lot records, temperature data, and U.S. Census demographic data, we ask two research questions: (1) What role do differences in neighborhood ambient heat, structural conditions and behavior play in helping to explain residential energy use? And (2) In what ways do energy expenditures spatially cluster in relation to urban heat islands? Using linear regression, spatial regression, and spatial clustering techniques, we evaluated the role of physical location of these households in relation to ambient temperatures. Significant positive relationships among energy expenditures and building size, average household size, White population, and population over 65 were observed; Significant negative relationships among energy expenditures and building density, renter population and population with a bachelor’s degree or higher were also observed. Negative relationships among morning and afternoon measures of heat, suggest that some areas spend less on energy use as a result of the neighborhood scale thermal environment. Spatial analysis of ambient temperature and energy expenditures show that energy use throughout the city is spatially clustered, with more affluent areas using more energy, regardless of whether heat islands are present. The results help to frame the role that increasing ambient temperatures in cities play in the spatial disparity in energy demand.

Residential Buildings, Energy Expenditure, Socio-d↗

Future grid mix impacts on whole-building life cycle assessment

Building construction and operation are a significant contribution to global greenhouse gas emissions, so understanding and mitigating emissions is crucial for reliable and realistic emissions accounting. Whole-building Life Cycle Assessment (WBLCA) is an emissions accounting method that considers lifetime environmental impacts of a building during its construction, operation, and eventual end-of-life. When performing WBLCAs, emission calculations from the building's operation over the entire building lifespan are typically based on today's energy grid mixes. This method does not consider changes or advancements in the clean energy proportion within the grid mix and can over or under-inflate results, skewing the ratio of embodied vs. operational environmental impacts. While a variety of prediction tools estimate what future grid emissions might be, predictions can vary widely. To predict the clean energy ratio within future grid mixes and the potential impact these changes might have on WBLCA, annual data from several existing U.S. grid models was averaged and probabilistic modeling was used to extend the usable projections of shorter forecasts. Results show that clean energy sources will likely continue to increase over time, although the rate of growth varies by model. On average, by 2085, the clean energy penetration of the grid is projected to reach ~81% and renewable energy is projected to reach ~71%, although no widespread consensus is reached. To understand how the future grid mix impacts lifetime building emissions within a WBLCA context, the team analyzed two 2021 IECC-compliant all-electric residential buildings: one built from traditional materials and construction processes and the other built with carbon sequestering materials and modular assembly, with a portion of energy generated on site. The results indicate that a moderate estimate of future electricity grid mixes shows a reduction of yearly operational emissions for traditional residential buildings of 55% between 2025 and 2085, and a corresponding reduction of 48% of total emissions over a 60 year building lifespan. This study offers a nuanced approach to account for the variability of future grid mix models and provides an average trend-line based on a robust collection of scenarios.

Life Cycle Assessment (LCA)↗

Energy savings and life cycle cost analysis of advanced double skin facade system applied to old apartments in South Korea

South Korea is one of the most densely populated countries in the world, and the population density in urban areas is much higher among others. Apartments are the most common form of residential buildings due to their high population density. More than 60% of domestic residential buildings are apartments, with more than 10 million households. The high population density is a problem that has long plagued South Korea because more than 45% of apartments are old apartments that are more than 20 years old. Old apartment buildings have low thermal performance that results in lots of energy consumption. Balconies, which worked as a thermal buffer, are also being removed by residents to expand indoor space. According to the green remodeling project supported by the Korean government, the typical retrofitting method is replacing external windows with the high-efficiency window in old apartments in South Korea. Here, this paper proposes a retrofitting method using an extended double-skin façade (DSF) system that replaces exterior windows and acts as a thermal buffer. The simulation model is developed with the EnergyPlus simulation program to conduct energy performance analyses. The simulation model has been calibrated using actual experimental data collected between October 1, 2019, and January 15, 2020. Results show that the cooling, heating, and lighting energy can be reduced up to 44.1% by fully utilizing electric energy generated by solar PV panels integrated with the DSF system. The payback period is about 15 years based on the energy price provided by the utility company. Although the payback period is long, it has great potential of energy savings and CO 2 emission reductions. The DSF system should be considered as a way of renovation, considering other factors such as increased real estate values and energy cost increases in the future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

National Cost-Effectiveness of ANSI/ASHRAE/IES Standard 90.1–2019

The purpose of this analysis is to examine the cost-effectiveness of the 2019 edition of ANSI/ASHRAE/IES Standard 90.1, which is developed by the ASHRAE Standard Standing Project Committee (SSPC) 90.1, and is the model energy standard for all commercial buildings and multifamily residential buildings over three floors. PNNL analyzed the cost-effectiveness of changes in Standard 90.1-2019, compared to the previous 90.1-2016 edition, as applied in commercial buildings across the United States. In reviewing proposed changes to Standard 90.1, the SSPC considers the cost-effectiveness of individual changes (addenda). Due to the continuous nature of the development process, however, ASHRAE does not evaluate the entire package of addenda from one edition of the standard to the next, which is of particular interest to adopting state and local governments. Providing states with an analysis of cost-effectiveness facilitates a more comprehensive understanding of the impacts associated with updated model energy codes, informs the state decision-making process and its authorities, and ultimately encourages greater adoption of updated of energy codes. This information also informs the development of future editions of Standard 90.1.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

National Cost-Effectiveness of ANSI/ASHRAE/IES Standard 90.1-2022

The purpose of this analysis is to examine the cost-effectiveness of the 2022 edition of ANSI/ASHRAE/IES Standard 90.1, which is developed by the ASHRAE Standard Standing Project Committee (SSPC) 90.1 and is the model energy standard for all commercial buildings and multifamily residential buildings over three floors. PNNL analyzed the cost-effectiveness of changes in Standard 90.1-2022, compared to the previous 90.1-2019 edition, as applied in commercial buildings across the United States. In reviewing proposed changes to Standard 90.1, the SSPC considers the cost-effectiveness of individual changes (addenda). Due to the continuous nature of the development process, however, ASHRAE does not evaluate the entire package of addenda from one edition of the standard to the next, which is of particular interest to adopting state and local governments. Providing states with an analysis of cost-effectiveness facilitates a more comprehensive understanding of the impacts associated with updated model energy codes, informs the state decision-making process and its authorities, and ultimately encourages greater adoption of updated energy codes. This information also informs the development of future editions of Standard 90.1.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Techno-Economic Assessment of Residential Heat Pump Integrated with Thermal Energy Storage

Phase change material (PCM)-based thermal energy storage (TES) can provide energy and cost savings and peak demand reduction benefits for grid-interactive residential buildings. Researchers established that these benefits vary greatly depending on the PCM phase change temperature (PCT), total TES storage capacity, system configuration and location and climate of the building. In this study, preliminary techno-economic performance is reported for a novel heat pump (HP)-integrated TES system using an idealized approach. A simplified HP-TES was modeled for 1 year of space heating and cooling loads for a residential building in three different climates in the United States. The vapor compression system of the HP was modified to integrate with TES, and all heat transfer to and from the TES was mediated by the HP. A single PCM was used for heating and cooling, and the PCT and TES capacity were varied to observe their effects on the building’s energy consumption, peak load shifting and cost savings. The maximum reduction in electric consumption, utility cost and peak electric demand were achieved at a PCT of 30 °C for New York City and 20 °C for Houston and Birmingham. Peak energy consumption in Houston, New York City, and Birmingham was reduced by 47%, 53%, and 70%, respectively, by shifting peak load using a time-of-use utility schedule. TES with 170 MJ storage capacity allowed for maximum demand shift from on-peak to off-peak hours, with diminishing returns once the TES capacity equaled the daily building thermal loads experienced during the most extreme ambient conditions.

25 ENERGY STORAGE↗

Hierarchical Model-Free Transactive Control of Building Loads to Support Grid Services

Residential buildings consume 4.4 quads of electricity annually, approximately 37% of the total electricity consumption in the United States. This represents a vast resource that can be used for demand management and other ancillary services. This project aims to develop a robust, scalable hierarchical transactional control mechanism incorporating elements of model-free control (MFC) and game theory to harness buildings to provide ancillary services to the grid. This approach is being taken to address the challenges of incorporating traditional transactional control schemes into existing buildings. The challenges include small individual building sizes requiring aggregation of many buildings, unpredictable energy usage that makes model identification difficult, and satisfying the sensitive occupant comfort constraints. In the proposed approach, by separating the control mechanism into two layers above and below the load aggregator, MFC can be used below the aggregator to modulate flexible building loads in response to pricing signals with guaranteed performance. This allows the burden of identifying an accurate model of the system to be shifted to the above-aggregator layer, where fluctuations in individual building usage have less impact on predicted building system behavior. Game theory concepts can then be used to determine pricing curves and control signals among regional aggregators. Managing this control in a game-theoretic approach will allow us to build in financial incentives that increase customer engagement. Additionally, the usage of MFC necessitates less burdensome computational and communication requirements, thus, it is easily deployable on small, embedded devices. In a broader sense, developing a strategy capable of effectively incorporating residential and small commercial buildings will allow greater throughput of existing and emerging grid services in addition to future transactive energy grid management methods. Using MFC within a hierarchical control architecture will allow the shifting of existing forecasting challenges to an aggregate level, where dynamics are slower and more predictable. This will enable a smooth interface between the grid services requests of utilities and the reliable control required by participating buildings. MFC, which supports distributed control architecture, permits a scalable solution that can be deployed to neighborhood-size systems as well as individual buildings. This project focuses on three objectives: (1) developing the mathematical framework, algorithm toolkit, and software toolset of the two-layer transactive control testbed; (2) developing a scalable solution for application over many residential and small-size commercial buildings with sparse distributed communication; and (3) field testing and implementation on hardware of the control strategies developed in the previous two objectives. The research and development activities are focused and designed to be impactful within the relevant 2025 targets timeframe. An open-source control framework for exploiting variability and dispatchability of building loads will be delivered as the outcome of the project. This capability enables greater participation of loads in electricity markets and ancillary services that are both useful for the utility and financially beneficial for building owners.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

COVID-19 impacts on residential occupancy schedules and activities in U.S. Homes in 2020 using ATUS

Many aspects of the daily lives of those living in the United States were substantially impacted by the COVID-19 pandemic in the year 2020. A broad diversity of measures was implemented to curb the spread of the virus, many of which included adjustments to where and how people worked, went to school, and otherwise conducted their daily lives compared to pre-pandemic times. This has impacted how residential buildings are used, how much time people spend in their homes, and as a result, how much energy these buildings consume. The main objective of this study is to analyze, at a national scale, the differences in the occupancy schedules and activities conducted in homes in the U.S., as compared to pre-pandemic. 15 years of American Time Use Survey and Current Population Survey data, from 2006 to 2020, was used in this study to analyze the occupancy schedules for both pandemic (2020) and pre-pandemic (2006–2019) times. These impacts were also analyzed with respect to variables including, weekday/weekend, month of the year, age of the occupants, household income, and household size. The impact of the pandemic on occupant schedules were most substantial in the initial months, whereas as the months progressed, these occupancy profiles slowly changed. Across 2020, people spent, on average, 8 % more time (1.9 h) in their home on weekdays, and 3–6 % (1.2 h) on weekend days. The percentage of time spent for different activities and locations within homes were also studied. For 1-member households, their time spent at home decreased whereas for 2-, 3-, and 4- member households, they spent more time at home. Overall, people spent around 45% more time doing office- and work-related activities at home compared to pre-pandemic, which is likely due to increased remote working and schooling. This research helps to improve the understanding of the occupancy presence and absence profiles in U.S. residential buildings due to the pandemic and provides new insights as to modified profiles for researchers, building designers, and policy makers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Savings in Action: Lessons Learned from a Vermont Community with Solar Plus Storage

As the U.S. works to meet emissions reduction goals and modernize power sector operations, residential buildings - which account for 21% of the total U.S. electricity consumption - will play a key role. Residential buildings with energy efficiency and distributed energy resources are able to provide value to multiple stakeholders, including the occupant, utility, and society at large. To account for this, multiple metrics that capture the value each stakeholder gets are required. This report contains analysis of a unique solar plus storage community in Vermont, including the calculation of multiple metrics and a unique "score card" that succinctly captures all of the value in a single figure.

14 SOLAR ENERGY↗

Demographic Information Incorporated Household Energy Consumption Analysis

The high energy consumption from residential buildings provides them large potential to participate in demand response programs. To design appropriate demand response programs for residential buildings, it is important for electric utilities to know the energy consumption characteristics for different types of households so that utilities can send requests to the groups with a higher possibility to successfully respond. In this paper, we develop a load model to generate synthetic load profiles for different types of households incorporating demographical information including Current Population Survey data set and American Time Use Survey data set. The details of each data set and the details of the load models are presented. The synthetic household load profiles are generated by the load model and clustered into different groups based on state, age, number of occupants, income level, and city of the household. The average energy consumption characteristics for different groups of households are analyzed and compared, which will help electric utilities issue demand response signals to appropriate households.

building loads↗

OCHRE™ Gymnasium (ochre_gym) [SWR-23-47]

OCHRE™ Gymnasium is a Python framework for conducting reinforcement learning research on residential building energy management problems. It is a lightweight wrapper around OCHRE, a Python-based thermal-electric residential building simulator developed in-house at NREL. OCHRE Gymnasium adheres to the standard OpenAI Gym API for a reinforcement learning environment. Detailed Sphinx documentation will be auto-generated and accompany this codebase. This documentation will detail the API, provide examples of how to use the code, etc.

Emami, Patrick↗