Search NASA⌕ Search

SEARCH · Search NASA

Results for “SANDWICH PLATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Construction and Design of a full size sTGC prototype for the ATLAS New Small Wheel upgrade

For the forthcoming Phase-I upgrade to the LHC (2018/19), the first station of the ATLAS muon end-cap system, Small Wheel, will need to be replaced. The New Small Wheel (NSW) will have to operate in a high background radiation region while reconstructing muon tracks with high precision as well as furnishing information for the Level-1 trigger. In particular, the precision reconstruction of tracks requires a spatial resolution of about 100 μm, and the Level-1 trigger track segments have to be reconstructed with an angular resolution of approximately 1 mrad. The NSW will have two chamber technologies, one primarily devoted to the Level-1 trigger function the small-strip Thin Gap Chambers (sTGC) and one dedicated to precision tracking, Micromegas detectors, (MM). The single sTGC planes of a quadruplet consists of an anode layer of 50 μm gold plated tungsten wire sandwiched between two resistive cathode layers. Behind one of the resistive cathode layers, a PCB with precise machined strips (thus the name sTGC's) spaced every 3.2 mm allows to achieve the position resolution that ranges from 70 to 150 μm, depending on the incident particle angle. Behind the second cathode, a PCB that contains an arrangement of pads, allows for a fast coincidence between successive sTGC layers to tag the passage of a track and reads only the corresponding strips for triggering. To be able to profit from the high accuracy of each of the sTGC planes for trigger purposes, their relative geometrical position between planes has to be controlled to within a precision of about 40 μm in their parallelism, as well (due to the various incident angles), to within a precision of 80 μm in the relative distance between the planes to achieve the overall angular resolution of 1 mrad. The needed accuracy in the position and parallelism of the strips is achieved by machining brass inserts together when machining the strip patterns into the cathode boards in a single step. The inserts can then be used as external references on a granite table. Precision methods are used to maintain high accuracy when combining four single detector gaps first into two doublets and then into a quadruplet. We will present results on the ongoing construction of full size (∼1 x 1 m) sTGC quadruplet prototypes before full construction starts in 2015. (authors)

43 PARTICLE ACCELERATORS↗

Powder diffraction from solids in the terapascal regime

A method of obtaining powder diffraction data on dynamically compressed solids has been implemented at the Jupiter and OMEGA laser facilities. Thin powdered samples are sandwiched between diamond plates and ramp compressed in the solid phase using a gradual increase in the drive-laser intensity. The pressure history in the sample is determined by back-propagation of the measured diamond free-surface velocity. A pulse of x rays is produced at the time of peak pressure by laser illumination of a thin Cu or Fe foil and collimated at the sample plane by a pinhole cut in a Ta substrate. The diffracted signal is recorded on x-ray sensitive material, with a typical d-spacing uncertainty of {approx}0.01 A. This diagnostic has been used up to 0.9 TPa (9 Mbar) to verify the solidity, measure the density, constrain the crystal structure, and evaluate the strain-induced texturing of a variety of compressed samples spanning atomic numbers from 6 (carbon) to 82 (lead). Further refinement of the technique will soon enable diffraction measurements in solid samples at pressures exceeding 1 TPa.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tuning Organic Semiconductor Packing and Morphology through Non-equilibrium Solution Processing (Final Report)

Organic semiconductors (OSCs) are a promising candidate to produce low-cost, large area, and flexible electronics. There has previously been successful development of organic field effect transistors (OFETs), photovoltaics (OPV), and bioelectronics using OSCs. Solution processing of these materials allows for the fabrication of large-area devices in the kinetic crystallization regime. The charge transport capabilities have been shown to depend on the morphology and molecular packing of the OSC within thin films. Our hypothesis is that solution processing conditions may significantly impact OSC morphology and as a result the charge transport. Therefore, this work has focused on obtaining a fundamental understanding of the morphology and molecular packing of OSCs for optimal device performance. Through our work, we have gained a better understanding of how these structural conditions were influenced by the solution processing conditions. Our studies have led to a more systematic understanding of the various parameters that impact OSC morphology. Solution processing leads to non-equilibrium films, thus allowing for the formation of diverse morphologies that are inaccessible by other fabrication methods. Previously, our group has focused on tuning the morphology of small-molecular OSCs [53, 55-57]. However, little work had been devoted to polymer OSCs. There was a lack of detailed studies characterizing the solution-state of polymer OSCs in terms of their conformation, degree of entanglement, polymer aggregation, and chain relaxation dynamics. The solution state properties are also likely to be influenced by the rigidity and molecular weight of the polymer OSCs investigated. Thus, we have focused our attention on gaining a better insight of polymer OSC films and solution processing methods. Through this proposal, our approach is to investigate the correlation between solution-state properties and the morphology of the resulting polymer OSC films. We worked three specific aims: investigate the effects of 1) polymer OSC solution-state properties on final film morphology; 2) molecular additives on the solution-state and final film properties; 3) controlled pre-aggregation in the solution-state in the final film morphology. More rigid and planar polymer backbones should promote interchain charge transport and more efficient interchain hopping between polymer chains. Through tailoring the polymer backbone, polymer sidechains, and molecular weight, we expected the altered solution-state properties to affect the final film morphology. In addition, reducing the entanglements and promoting chain alignment will likely prevent charge carrier trapping through conformation disorders. We thus studied different mechanisms, such as molecular additives, to reduce entanglements in solution. Devices fabricated from these solutions were expected to have improved charge transport abilities. In addition to tailoring the solution-state characteristics of the polymer OSCs, we investigated the effect of solution processing methods on the molecular packing and morphology of polymer OSC films. Two main solution processing techniques, e.g., spin-coating and solution shearing, were employed to fabricate OFETs. Spin coating was employed to prepare OSC films, which produce isotropic films. This technique creates several parameters to tune such as spin coating speed, acceleration, and time. Additionally, our research group developed the solution shearing method, which consists of the solution initially sandwiched between two plates. By sliding the top plate, the solution front is exposed and drying begins. This technique allows for the creation of aligned large crystalline domains. Solution shearing consists of different processing parameters which can affect the final morphology, such as shearing speed, substrate temperature and temperature gradient, distance between both plates, and the tilt angle of the top plate. Due to the complexity of the polymer systems investigated, numerous techniques were employed to characterize the polymer OSC solution state and films. All the materials were characterized using the DOE supported synchrotron X-ray scattering facilities at the Stanford Synchrotron Radiation Lightsource (SSRL). Using grazing incidence X-ray scattering (GIXS) and Near Edge X-ray Absorption Fine Structure (NEXAFS) techniques, the crystalline structure and molecular orientations of the thin films were measured. Optical absorption (UV-Vis) spectroscopy was employed to determine the aggregation state in solution and films of the polymer systems. Polarized UV-Vis also allowed for the determination of the relative degree of polymer chain alignment for solution sheared films. Additionally, various other techniques were used to investigate other properties within the film, such as atomic force microscopy (AFM) and solution rheology. Finally, the device performance is quantified through the fabrication and characterization of OFETs, which will highlight the effects of morphology on charge transport.

36 MATERIALS SCIENCE↗

Graphite-epoxy panel compression strength reduction due to local impact

A review of results from on-going research to investigate the effects of low-velocity impact on the compressive strength of graphite-epoxy structures is presented. Extensive tests have been conducted on sandwich beams, laminated plates and stiffened panels. Conditions for failures were investigated by impact tests on statically loaded test specimens. The effects of compression load intensity were such that lightly loaded graphite structures (such as aircraft secondary structure) were insensitive to impact damage. In more heavily loaded structures, (such as wing panels), however, appreciable reductions in compressive strength occurred. The implications of the tests for structural design are discussed by comparing panel masses for designs where ultimate strains have been reduced due to impact considerations with the masses of designs with higher ultimate strains. Finally, preliminary test data is presented to show the possibility of improvements in damage tolerance achievable by using an alternate matrix material.

Card, M. P.↗

Graphite-epoxy panel compression strength reduction due to local impact

The effects of low velocity impact on the compressive strength of graphite/epoxy structures are reviewed. Extensive tests were conducted on sandwich beams, laminated plates and stiffened panels. Conditions for failures were investigated by impact tests on statically loaded test specimens. Lightly loaded graphite structures (such as aircraft secondary structure) were insensitive to impact damage. In more heavily loaded structures, (such as wing panels), appreciable reductions in compressive strength occurred. The implications of the tests for structural design are discussed by comparing panel masses for designs where ultimate strains were reduced due to impact considerations with the masses of designs with higher ultimate strains. Preliminary test data are presented to show the possibility of improvements in damage to tolerance achievable by using an alternate matrix material.

Card, M. F.↗

Optimized bolted joint

A method is disclosed for joining segments of the skin of an aircraft. The ends of the skin are positioned in close proximity or abutt each other. The skin is of constant thickness throughout the joint and is sandwiched between splice plates, which taper in thickness from the last to the first bolt rows in order to reduce the stiffness of the splice plate and thereby reduce the load transfer at the location where bypass loads are the highest.

Hart-Smith, L. J.↗

Overall contact conductance of a prototype Parallel Fin Thermal Interface

The Parallel Fin Thermal Interface has been developed and tested as an orbital replaceable interface. The interface consists of two identical plates with pairs of opposing parallel straight fins. Each pair of fins is sandwiched between two insert plates pressed against the fins with enough force for good heat transfer through the interface. Two prototype parallel fin interfaces were built (Model 140 and 380) with different fin and insert plate dimensions. Samples of the interfacing surfaces were found to have roughness values ranging from 22 to 35 microinches. Overall interface conductance (Hc) values of 46.7 to 74.2 Btu/hr sq ft-F were obtained for the 140 model in vacuum with an interface pressure from 18.8 to 37.5 psi, respectively. The Model 380 exhibited Hc values from 31.2 to 46.8 Btu/hr sq ft-F in vacuum, with respective interface pressures of 14.2 and 22.0 psi. Several correlations were found to agree with test data to within 20 percent.

Stobb, C. A.↗

Electrostatic Stabilization Of Growing Protein Crystals

Proposed technique produces large crystals in compact, economical apparatus. Report presents concept for supporting protein crystals during growth in microgravity. Yields crystals larger and more-nearly perfect than those grown on Earth. Combines best features of sandwich-drop and electrostatic-levitation methods of support. Drop of protein solution inserted between pair of glass or plastic plates, as in sandwich-drop-support method. Electrostatically charged ring confines drop laterally and shapes it, as in electrostatic technique. Apparatus also made to accommodate several drops simultaneously between same pair of supporting plates. Drops can be inserted and crystals removed through ducts in plates.

Shlichta, Paul J.↗

Remotely operable peristaltic pump

A peristaltic pump is disclosed which includes a roller assembly on which is mounted a series of pump rollers. As the roller assembly is rotated by a drive gear the pump rollers are driven in reverse rotation by means of a stationary ring gear and pump roller gears. An upper pressure shoe plate and a lower pressure shoe plate are positioned above sets of flexible tubing. The tubing is sandwiched between the pressure shoe plates and the pump rollers. A highly compact pump is provided having twice as many fluid channel lines as is conventional. The peristaltic pump device may be remotely operated by means of a rotary actuator which rotates a driving hub to move the shoe plates by means of eccentrically mounted links. The pressure shoe plates may be moved by the rotary actuator to a loaded position in which the fluid lines are pinched by the pump rollers and fluid is pumped to an unloaded position in which the fluid lines are maintained in an undeformed, uncrimped configuration so that no creases or crimps are set into the fluid lines during periods of prolonged nonuse.

Belew, R. R.↗

Lightweight Stacks of Direct Methanol Fuel Cells

An improved design concept for direct methanol fuel cells makes it possible to construct fuel-cell stacks that can weigh as little as one-third as much as do conventional bipolar fuel-cell stacks of equal power. The structural-support components of the improved cells and stacks can be made of relatively inexpensive plastics. Moreover, in comparison with conventional bipolar fuel-cell stacks, the improved fuel-cell stacks can be assembled, disassembled, and diagnosed for malfunctions more easily. These improvements are expected to bring portable direct methanol fuel cells and stacks closer to commercialization. In a conventional bipolar fuel-cell stack, the cells are interspersed with bipolar plates (also called biplates), which are structural components that serve to interconnect the cells and distribute the reactants (methanol and air). The cells and biplates are sandwiched between metal end plates. Usually, the stack is held together under pressure by tie rods that clamp the end plates. The bipolar stack configuration offers the advantage of very low internal electrical resistance. However, when the power output of a stack is only a few watts, the very low internal resistance of a bipolar stack is not absolutely necessary for keeping the internal power loss acceptably low.

Narayanan, Sekharipuram↗

Compressive Strength of Stainless-Steel Sandwiches at Elevated Temperatures

Experimental results are presented from crippling tests of stainless-steel sandwich specimens in the temperature range from 80 F to 1,200 F. The specimens included resistance-welded 17-7 PH stainless-steel sandwiches with single-corrugated cores, type 301 stainless-steel sandwiches with double-corrugated cores, and brazed 17-7 PH stainless-steel sandwiches with honeycomb cores. The experimental strengths are compared with predicted buckling and crippling strengths. The crippling strengths were predicted from the calculated maximum strength of the individual plate elements of the sandwiches and from a correlation procedure which gives the elevated-temperature crippling strength when the experimental room-temperature crippling strengths are known. Photographs of some of the tested specimens are included to show the modes of failure.

Mathauser, Eldon E.↗

A swirl flow evaporative cold plate

A forced flow evaporative cold plate is under development for future application to the thermal bus concept being pursued by NASA for Space Station Thermal Control. The vaporizer is a swirl-flow device employing a spiral tube coil geometry sandwiched between conductive metal plates upon which electric components could be mounted. This concept is based on the inherent phase separation that occurs in a two phase stream in curvilinear flow. This is a zero 'g' design with one 'g' all-attitude capability and is capable of high heat transfer coefficients, good isothermality, and the ability to function at heat fluxes approaching 5w/sq cm on the cold plates (10w/sq cm on the tube wall) with Freon 114. The advantages of this design over other two phase evaporator approaches are high heat flux capability, simplified control requirements, insensitivity to micro-gravity oscillations, and inexpensive manufacturability. The program included design, fabrication, and test of such a cold plate utilizing an existing test stand developed for two-phase thermal management system (TPTMS) testing. Test results analysis and conclusions are included.

Niggemann, R. E.↗

Device for measuring hole elongation in a bolted joint

A device to determine the operable failure mode of mechanically fastened lightweight composite joints by measuring the hole elongation of a bolted joint is disclosed. The double-lap joint test apparatus comprises a stud, a test specimen having a hole, two load transfer plates, and linear displacement measuring instruments. The test specimen is sandwiched between the two load transfer plates and clamped together with the stud. Spacer washers are placed between the test specimen and each load transfer plate to provide a known, controllable area for the determination of clamping forces around the hole of the specimen attributable to bolt torque. The spacer washers also provide a gap for the mounting of reference angles on each side of the test specimen. Under tensile loading, elongation of the hole of the test specimen causes the stud to move away from the reference angles. This displacement is measured by the voltage output of two linear displacement measuring instruments that are attached to the stud and remain in contact with the reference angles throughout the tensile loading. The present invention obviates previous problems in obtaining specimen deformation measurements by monitoring the reference angles to the test specimen and the linear displacement measuring instruments to the stud.

Wichorek, Gregory R.↗

A spatial light modulator that uses scattering in a cholesteric liquid crystal

When a cholesteric liquid crystal (helical pitch: 5 μm) was sandwiched between two glass plates with no alignment coating (gap: 20 μm), a random-domain texture appeared and a strong light scattering took place. This translucent texture turned to a transparent homeotropic phase when an electric voltage of 20 V was applied to the liquid crystal layer. This phase transition was used for constructing a spatial light modulator that needed no polarizers. Indium-tin-oxide electrodes (0.8 mm square) were arranged on a glass substrate to create a 20 × 20 pixel array (20 mm square). The liquid crystal was injected into a gap (20 μm thickness) between this substrate and another glass plate with a uniform electrode (ground). The transmittance of the pixels was originally below 10% and decreased to 0% by 7 V application because of increase in the scattering loss. As the voltage was raised, the transmittance increased gradually in the 7–17 V range and then rapidly in the 17–20 V range, attaining 40% at 27 V. Various transmittance distributions or gray-scale images were attainable by applying a suitable voltage (7–27 V) to each pixel. The transmission range of this spatial light modulator extended from ultraviolet (350 nm) to infrared wavelengths (>800 nm). Owing to this wide transmission range as well as capability of the polarizer-free operation, this spatial light modulator is useful to control a lamp spectrum in spectroscopic measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal protective visor for entering high temperature areas

Chamber observer suit visor protects the eyes and ears of the wearer while he is performing rescue operations during a fire. The visor is a simple curved sandwich of selected glass plates, gold coated polyester plastic film, and a dead air space, all mounted in an aluminum frame.

Burgett, F. A.↗

Methods for improved resolution of flow electrophoresis cells

First method involves remote adjusting of zeta potential. Second approach sandwiches two conducting metal plates between opposite cell walls and thin insulating layer. Third method forces buffer to flow in direction opposite particle streams.

Mccreight, L. R.↗

Flexible thermal apparatus for mounting of thermoelectric cooler

A flexible heat transfer apparatus used to flexibly connect and thermally couple a thermoelectric cooler to an object to be cooled is disclosed. The flexible heat transfer apparatus consists of a pair of flexible corrugated sheets made from high thermal conductivity materials such as copper, aluminum, gold, or silver. The ridges of the corrugated sheets are oriented perpendicular to one another and bonded sandwich-fashion between three plates to define an upper section and a lower section. The upper section provides X flexure, the lower section provides Y flexure, and both sections together provide Z flexure.

Jones, Jack A.↗