Search NASA⌕ Search

SEARCH · Search NASA

Results for “SCINTILLATION COUNTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Evaluate Scintillation Response Over a Continuous Energy Region

A recently developed fast analysis technique utilizing a time of flight (TOF) telescope is demonstrated to obtain relevant quantitative data on material scintillation response to energetic He particles. With superior energy resolution and fast response of the TOF telescope, energy of individual particle before impinging on a scintillating crystal can be determined with a high counting rate, which allows quantitative study of material performance over a continuous energy range in a relatively short time. Scintillation performances in terms of light output, nonlinearity and energy resolution in bismuth germinate (BGO) and europium-doped calcium fluoride (CaF2:Eu) Crystals are demonstrated, and the corresponding energy resolution is compared with gamma-ray tests on the same crystals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ANALYTICAL LABORATORY AT IDAHO NATIONAL LABORATORY COUNTING EQUIPMENT STANDARDIZATION AND QUALITY CONTROL IMPROVEMENT

The Analytical Laboratory at Idaho National Laboratory (INL) is a growing program with an emphasis on providing high quality results to customers, and an increasing focus on independent research. The Analytical Laboratory Counting Group has a number of capabilities: six gamma-ray counters, one gamma-ray sample changer, four gas flow proportional counter drawers, an auto-changing gas flow proportional counter, two liquid scintillation counters, and an alpha spectroscopy system. Other capabilities within the Analytical Laboratory include quadrupole inductively coupled plasma mass spectrometry (ICP-MS), high resolution ICP-MS, multi-collector ICP-MS, ICP atomic emission spectrometry (ICP-AES), gas mass spectrometry, thermal ionization mass spectrometry (TIMS), several glove boxes and fume hoods for sample preparation, and six interconnected hot cells for sample receipt and dissolution. In order to position the Analytical Laboratory as a world-class research institution, the Counting Group has recently begun making improvements to its analytical techniques, calibrations, standardization, and quality control procedures. A large part of this effort is to increase the level of documentation of instrument work. One project is to re-calibrate all of the gamma systems with newly purchased standards. One of the changes made in the purchase of the new standards was to lower the total activity so that the dead time of the calibration would more closely match the dead time of typical samples. Similarly, another planned project is to use new standards to re-calibration the gas flow proportional counters. Additional work has focused on testing and improving alpha spectroscopy sample preparation techniques. Plutonium separations have been tested to improve tracer recovery and to verify the separation technique in the presence of typical sample matrices. A final planned area of improvements has focused on liquid scintillation counting. One difficulty the Counting Group has encountered in liquid scintillation counting is an inflated gross alpha count relative to other analysis methods in the presence of high gross beta activity. Ideas include investigating the impact of choice of scintillation cocktail, as well as the effects of sample dilution.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A 2.8 K cryogen-free cryostat with compact optical geometry for multiple photon counting

Interest in solid scintillators down to liquid helium temperature and below has grown recently, fuelled by searches for exotic processes in particle physics. We describe a closed-cycle optical cryostat with a 2.8 K base temperature and a compact optical geometry for multiple photon counting. The large numerical aperture achieved, of the order of 0.79 from the optical center to each of the two windows and amounting to 40% of the total solid angle, allows a significant gain in the efficiency of photon collection. This and the relatively big sample size that can be used facilitate the study of scintillators under {gamma} irradiation. These features should be an asset for multiple photon counting techniques at low temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Delayed gamma-ray spectroscopy with lanthanum bromide detector for non-destructive assay of nuclear material

High-energy delayed γ-ray spectroscopy is a potential technique for directly assaying spent fuel assemblies and achieving the safeguards goal of quantifying nuclear material inventories for spent fuel handling, interim storage, reprocessing facilities, repository sites, and final disposal. Requirements for the γ-ray detection system, up to ~6 MeV, can be summarized as follows: high efficiency at high γ-ray energies, high energy resolution, good linearity between γ-ray energy and output signal amplitude, ability to operate at very high count rates, and ease of use in industrial environments such as nuclear facilities. High Purity Germanium Detectors (HPGe) are the state of the art and provide excellent energy resolution but are limited in their count rate capability. Lanthanum Bromide (LaBr 3 ) scintillation detectors offer significantly higher count rate capabilities at lower energy resolution. Thus, LaBr 3 detectors may be an effective alternative for nuclear spent-fuel applications, where count-rate capability is a requirement. This paper documents the measured performance of a 2” (length) × 2” (diameter) of LaBr3 scintillation detector system, coupled to a negatively biased PMT and a tapered active high voltage divider, with count-rates up to ~3 Mcps. An experimental methodology was developed that uses the average current from the PMT’s anode and a dual source method to characterize the detector system at specific very high count rate values. Delayed γ-ray spectra were acquired with the LaBr 3 detector system at the Idaho Accelerator Center, Idaho State University, where samples of ~3g of 235 U were irradiated with moderated neutrons from a photo-neutron source. Results of the spectroscopy characterization and analysis of the delayed γ-ray spectra acquired indicate the possible use of LaBr3 scintillation detectors when high count rate capability may outweigh the lower energy resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging performance comparison between a LaBr{sub 3}:Ce scintillator based and a CdTe semiconductor based photon counting compact gamma camera

The authors report on the performance of two small field of view, compact gamma cameras working in single photon counting in planar imaging tests at 122 and 140 keV. The first camera is based on a LaBr{sub 3}:Ce scintillator continuous crystal (49x49x5 mm{sup 3}) assembled with a flat panel multianode photomultiplier tube with parallel readout. The second one belongs to the class of semiconductor hybrid pixel detectors, specifically, a CdTe pixel detector (14x14x1 mm{sup 3}) with 256x256 square pixels and a pitch of 55 {mu}m, read out by a CMOS single photon counting integrated circuit of the Medipix2 series. The scintillation camera was operated with selectable energy window while the CdTe camera was operated with a single low-energy detection threshold of about 20 keV, i.e., without energy discrimination. The detectors were coupled to pinhole or parallel-hole high-resolution collimators. The evaluation of their overall performance in basic imaging tasks is presented through measurements of their detection efficiency, intrinsic spatial resolution, noise, image SNR, and contrast recovery. The scintillation and CdTe cameras showed, respectively, detection efficiencies at 122 keV of 83% and 45%, intrinsic spatial resolutions of 0.9 mm and 75 {mu}m, and total background noises of 40.5 and 1.6 cps. Imaging tests with high-resolution parallel-hole and pinhole collimators are also reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absolute light yield of the EJ-204 plastic scintillator

The absolute light yield of a scintillator, defined as the number of scintillation photons produced per unit energy deposited, is a useful quantity for scintillator development, research, and applications. Yet, literature data on the absolute light yield of organic scintillators are limited. The goal of this work is to assess the suitability of the EJ-204 plastic scintillator from Eljen Technology to serve as a reference standard for measurements of the absolute light yield of organic scintillators. Four EJ-204 samples were examined: two manufactured approximately four months prior and stored in high-purity nitrogen, and two aged approximately eleven years and stored in ambient air. The scintillator response was measured using a large-area avalanche photodiode calibrated using low energy $γ$-ray and X-ray sources. The product of the quantum efficiency of the photodetector and light collection efficiency of the housing was characterized using an experimentally-benchmarked optical photon simulation. The average absolute light yield of the fresh samples, 9100 ± 400 photons per MeV, is lower than the manufacturer-reported value of 10400 photons per MeV. Moreover, the aged samples demonstrated significantly lower light yields, deviating from the manufacturer specification by as much as 26%. These results are consistent with recent work showcasing environmental aging in plastic scintillators and suggest that experimenters should use caution when deploying plastic scintillators in photon counting applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Instrument for precision long-term β-decay rate measurements

We describe an experimental setup for making precision measurements of relative β-decay rates of {sup 22}Na, {sup 36}Cl, {sup 54}Mn, {sup 60}Co, {sup 90}Sr, {sup 133}Ba, {sup 137}Cs, {sup 152}Eu, and {sup 154}Eu. The radioactive samples are mounted in two automated sample changers that sequentially position the samples with high spatial precision in front of sets of detectors. The set of detectors for one sample changer consists of four Geiger-Müller (GM) tubes and the other set of detectors consists of two NaI scintillators. The statistical uncertainty in the count rate is few times 0.01% per day for the GM detectors and about 0.01% per hour on the NaI detectors. The sample changers, detectors, and associated electronics are housed in a sealed chamber held at constant absolute pressure, humidity, and temperature to isolate the experiment from environmental variations. The apparatus is designed to accumulate statistics over many years in a regulated environment to test recent claims of small annual variations in the decay rates. We demonstrate that absent this environmental regulation, uncontrolled natural atmospheric pressure variations at our location would imprint an annual signal of 0.1% on the Geiger-Müller count rate. However, neither natural pressure variations nor plausible indoor room temperature variations cause a discernible influence on our NaI scintillator detector count rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Distinguishing Pu Metal from Pu Oxide and Determining α-ratio using Fast Neutron Counting

We describe a new method for determining the ratio of the rate of (α, n) source neutrons to the rate of spontaneous fission neutrons, the so called α-ratio. This method is made possible by fast neutron counting with liquid scintillator detectors, which can determine the shape of the fast neutron spectrum. The method utilizes the spectral difference between fission spectrum neutrons from Pu metal and the spectrum of (α, n) neutrons from PuO 2 . Our method is a generalization of the Cifarelli-Hage method for determining k eff for fissile assemblies, and also simultaneously determines k eff along with the α-ratio.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Observational work on cosmic gamma rays

Cosmic gamma rays observation by balloon flight and satellite with scintillation detector, tabulating counting rates in pulse height channels relative to Crab Nebula

Clark, G. W.↗

AUTOMATED PROCESS MONITORING: APPLYING PROVEN AUTOMATION TECHNIQUES TO INTERNATIONAL SAFEGUARDS NEEDS

Identification and quantification of specific alpha- and beta-emitting radionuclides in complex liquid matrices is highly challenging, and is typically accomplished through laborious wet chemical sample preparation and separations followed by analysis using a variety of detection methodologies (e.g., liquid scintillation, gas proportional counting, alpha energy analysis, mass spectrometry). Analytical results may take days or weeks to report. Chains of custody and sample security measures may also complicate or slow the analytical process. When an industrial process-scale plant requires the monitoring of specific radionuclides as an indication of the composition of its feed stream or of plant performance, radiochemical measurements must be fast, accurate, and reliable. Scientists at Pacific Northwest National Laboratory have assembled a fully automated prototype Process Monitor instrument capable of a variety of tasks: automated sampling directly from a feed stream, sample digestion / analyte redox adjustment, chemical separations, radiochemical detection and data analysis / reporting. The system is compact, its components are fluidically inter-linked, and analytical results could be immediately transmitted to on- or off-site locations. The development of a rapid radiochemical Process Monitor for 99Tc in Hanford tank waste processing streams, capable of performing several measurements per hour, will be discussed in detail. More recently, the automated platform was modified to perform measurements of 90Sr in Hanford tank waste stimulant. The system exemplifies how automation could be integrated into reprocessing facilities to support international nuclear safeguards needs.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A matrix-inversion method for gamma-source mapping from gamma-count data

In a previous paper it was proposed that a simple matrix inversion method could be used to extract source distributions from gamma-count maps, using simple models to calculate the response matrix. The method was tested using numerically generated count maps. In the present work a 100 kBq Co{sup 60} source has been placed on a gridded surface and the count rate measured using a NaI scintillation detector. The resulting map of gamma counts was used as input to the matrix inversion procedure and the source position recovered. A multi-source array was simulated by superposition of several single-source count maps and the source distribution was again recovered using matrix inversion. The measurements were performed for several detector heights. The effects of uncertainties in source-detector distances on the matrix inversion method are also examined. The results from this work give confidence in the application of the method to practical applications, such as the segregation of highly active objects amongst fuel-element debris. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Real-time online monitoring of radwaste storage: A proof-of-principle test prototype

A prototype array of modular sensors for online monitoring of radioactive waste was developed at INFN-LNS. We implemented a new kind of gamma mini-sensor, based on Silicon Photomultipliers and scintillating fibers, that behaves like a cheap scintillating Geiger-Muller counter. It can be placed in shape of a fine grid around each single waste drum in a repository. After simulating the counting response of thin scintillating fibers to gamma radiation, we verified our simulation results with measurements using radioactive sources. Front-end electronics and an FPGA-based counting system were developed to handle the field data, also implementing data transmission, a graphical user interface and a data storage system. A test of four sensors in a real radwaste storage site was performed with promising results. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fast multiplicity counter featuring stilbene detectors for special nuclear material assay

The Treaty on the Nonproliferation of Nuclear Weapons demands for new instruments to prevent diversion of fissile material and safeguard controls. We present a fast neutron multiplicity counting system based on organic scintillators, i.e. liquid EJ-309 and stilbene. The system is able to detect fission correlated counts and photon and neutron multiplets, needed to quantify fissile mass, without the need of complex electronic circuitry and unfolding procedures, required in moderated systems. Moderated system, typically based on helium-3 detectors, feature a gate time of hundreds of microseconds. Conversely, the use of organic scintillators allows an exceptionally short gate time of hundreds of nanoseconds. This results in a reduction of accidental neutron coincidence. In our system, the superior gamma-neutron discrimination capabilities of stilbene scintillators allow to measure high-order multiplicities (> 3) and the inspection of complex source terms. This counter is thus also suitable for the assay of newer fuels containing plutonium and other fissionable actinides. A prototypal version of the well-counter was assembled and tested at the University of Michigan, using a spontaneous fission and an (a,n) neutron source, i.e. 252Cf and PuBe respectively. Presented measured results show excellent agreement with simulations. The viability of the system to discriminate time-correlated fission neutrons from random, uncorrelated neutrons was proved. An experimental campaign will be carried out at Idaho National Laboratory in August 2015 to characterize weapon grade plutonium samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Counting neutrons from the spontaneous fission of {sup 238}U using scintillation detectors and mixed field analysers

It is well documented that {sup 238}U decays by spontaneous fission, and that it is the main component of most nuclear fuels. As nuclear fuels are largely classed as Special Nuclear Material (SNM), they have to be fully accounted for by owners and processing facilities. One possible method for verifying declared amounts of SNM is to count the spontaneous neutrons produced from {sup 238}U. Using four EJ-309 liquid scintillation detectors and a mixed field analyser, spontaneous neutrons from 16.4 g of depleted uranium (0.3% enrichment) have been assayed. The assay method shows promising results and this proof of principle will be researched further in order for it to be applied in an industrial setting. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Long-length Scintillating Fibers for Nuclear Waste Repositories (Conference Record)

This paper describes the fabrication, testing, and characterization of long-length, up to 50 m, scintillating fibers for the purpose of radiation monitoring in inaccessible radiological and nuclear waste repositories. The fabrication aspect was focused on ruggedizing the 1-mm diameter fiber and limiting external light interference for fibers. Testing and characterization were performed in a laboratory setting with radiation sources, a photosensor module and a multi-channel analyzer. Light attenuation was studied as a function of distance by analyzing both the spectrum and count rate. Additionally, the scintillating fibers were coupled to optical communication fibers (100 m) to extend the reach of the system. This paper also includes the optical spectrometry results from the sensitivity and response of the signal attenuation. Lastly, the paper covers the field testing of the scintillating fibers in a relevant environment.

47 - OTHER INSTRUMENTATION↗

Single proton counting at the RIKEN cell irradiation facility

We present newly developed tapered capillaries with a scintillator window, which enable us to count single protons at the RIKEN cell irradiation setup. Their potential for performing single proton irradiation experiments at our beamline setup is demonstrated with CR39 samples, showing a single proton detection fidelity of 98%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Muon counting using silicon photomultipliers in the AMIGA detector of the Pierre Auger observatory

Here, AMIGA (Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory designed to extend its energy range of detection and to directly measure the muon content of the cosmic ray primary particle showers. The array will be formed by an infill of surface water-Cherenkov detectors associated with buried scintillation counters employed for muon counting. Each counter is composed of three scintillation modules, with a 10 m 2 detection area per module. In this paper, a new generation of detectors, replacing the current multi-pixel photomultiplier tube (PMT) with silicon photo sensors (aka. SiPMs), is proposed. The selection of the new device and its front-end electronics is explained. A method to calibrate the counting system that ensures the performance of the detector is detailed. This method has the advantage of being able to be carried out in a remote place such as the one where the detectors are deployed. High efficiency results, i.e. 98% efficiency for the highest tested overvoltage, combined with a low probability of accidental counting (~2%), show a promising performance for this new system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantification of Technetium-99 in Complex Groundwater Matrixes using a Radiometric Preconcentrating Minicolumn Sensor in an Equilibration-based Sensing Approach

A preconcentrating minicolumn sensor for pertechnetate detection in water consists of a packed bed containing a mixture of anion exchange resin and scintillating plastic beads. The column materials are contained in a transparent plastic flow cell placed between two photomultiplier tubes for radiometric detection. Upon retention of pertechnetate anions, the radioactive decay of Tc-99 results in detectable scintillation pulses that are counted in coincidence. In equilibration-based sensing mode, the sample is pumped through the packed bed until complete chromatographic equilibrium is achieved between the activity concentration in the water sample and the concentration on the anion exchange resin. The analytical signal is the observed steady state count rate at equilibrium. The sensitivity is related to a measurement efficiency parameter that is the product of the retention volume and the absolute radiometric detection efficiency. This sensor can readily detect pertechnetate to levels ten times below the drinking water standard of 0.033 Bq/mL. The potential for other anions in natural groundwater and contaminated groundwater plumes to interfere with pertechnetate detection and quantification have been examined in detail, with reference to the groundwater chemistry at the Hanford Site in Washington State. Individual anions such as nitrate, carbonate, chloride and iodide, at natural or elevated concentrations, do not interfere significantly with pertechnetate uptake on the anion exchange resin. Elevated chromate or sulfate anion concentrations can interfere with pertechnetate uptake by the resin, but only at levels substantially higher than typical concentrations in groundwater or contamination plumes. Nevertheless, elevated anion concentrations may reduce pertechnetate uptake and sensitivity of the sensor when present in combination. Chromate is retained on the anion exchange resin from water at ppb levels, leading to an orange stain that interferes with pertechnetate detection by the absorption of scintillation light pulses (color quench). Radioactivity from radioiodine, tritium, and uranium are not expected to create a significant positive bias in groundwater analyses. A method of automated fluidic standard addition is demonstrated that corrects for matrix interferences leading to accurate analyses over a wide range of groundwater compositions.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗