Search NASA⌕ Search

SEARCH · Search NASA

Results for “SCINTILLATION COUNTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Real-time online monitoring of radwaste storage: A proof-of-principle test prototype

A prototype array of modular sensors for online monitoring of radioactive waste was developed at INFN-LNS. We implemented a new kind of gamma mini-sensor, based on Silicon Photomultipliers and scintillating fibers, that behaves like a cheap scintillating Geiger-Muller counter. It can be placed in shape of a fine grid around each single waste drum in a repository. After simulating the counting response of thin scintillating fibers to gamma radiation, we verified our simulation results with measurements using radioactive sources. Front-end electronics and an FPGA-based counting system were developed to handle the field data, also implementing data transmission, a graphical user interface and a data storage system. A test of four sensors in a real radwaste storage site was performed with promising results. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fast multiplicity counter featuring stilbene detectors for special nuclear material assay

The Treaty on the Nonproliferation of Nuclear Weapons demands for new instruments to prevent diversion of fissile material and safeguard controls. We present a fast neutron multiplicity counting system based on organic scintillators, i.e. liquid EJ-309 and stilbene. The system is able to detect fission correlated counts and photon and neutron multiplets, needed to quantify fissile mass, without the need of complex electronic circuitry and unfolding procedures, required in moderated systems. Moderated system, typically based on helium-3 detectors, feature a gate time of hundreds of microseconds. Conversely, the use of organic scintillators allows an exceptionally short gate time of hundreds of nanoseconds. This results in a reduction of accidental neutron coincidence. In our system, the superior gamma-neutron discrimination capabilities of stilbene scintillators allow to measure high-order multiplicities (> 3) and the inspection of complex source terms. This counter is thus also suitable for the assay of newer fuels containing plutonium and other fissionable actinides. A prototypal version of the well-counter was assembled and tested at the University of Michigan, using a spontaneous fission and an (a,n) neutron source, i.e. 252Cf and PuBe respectively. Presented measured results show excellent agreement with simulations. The viability of the system to discriminate time-correlated fission neutrons from random, uncorrelated neutrons was proved. An experimental campaign will be carried out at Idaho National Laboratory in August 2015 to characterize weapon grade plutonium samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Counting neutrons from the spontaneous fission of {sup 238}U using scintillation detectors and mixed field analysers

It is well documented that {sup 238}U decays by spontaneous fission, and that it is the main component of most nuclear fuels. As nuclear fuels are largely classed as Special Nuclear Material (SNM), they have to be fully accounted for by owners and processing facilities. One possible method for verifying declared amounts of SNM is to count the spontaneous neutrons produced from {sup 238}U. Using four EJ-309 liquid scintillation detectors and a mixed field analyser, spontaneous neutrons from 16.4 g of depleted uranium (0.3% enrichment) have been assayed. The assay method shows promising results and this proof of principle will be researched further in order for it to be applied in an industrial setting. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Long-length Scintillating Fibers for Nuclear Waste Repositories (Conference Record)

This paper describes the fabrication, testing, and characterization of long-length, up to 50 m, scintillating fibers for the purpose of radiation monitoring in inaccessible radiological and nuclear waste repositories. The fabrication aspect was focused on ruggedizing the 1-mm diameter fiber and limiting external light interference for fibers. Testing and characterization were performed in a laboratory setting with radiation sources, a photosensor module and a multi-channel analyzer. Light attenuation was studied as a function of distance by analyzing both the spectrum and count rate. Additionally, the scintillating fibers were coupled to optical communication fibers (100 m) to extend the reach of the system. This paper also includes the optical spectrometry results from the sensitivity and response of the signal attenuation. Lastly, the paper covers the field testing of the scintillating fibers in a relevant environment.

47 - OTHER INSTRUMENTATION↗

Single proton counting at the RIKEN cell irradiation facility

We present newly developed tapered capillaries with a scintillator window, which enable us to count single protons at the RIKEN cell irradiation setup. Their potential for performing single proton irradiation experiments at our beamline setup is demonstrated with CR39 samples, showing a single proton detection fidelity of 98%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Muon counting using silicon photomultipliers in the AMIGA detector of the Pierre Auger observatory

Here, AMIGA (Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory designed to extend its energy range of detection and to directly measure the muon content of the cosmic ray primary particle showers. The array will be formed by an infill of surface water-Cherenkov detectors associated with buried scintillation counters employed for muon counting. Each counter is composed of three scintillation modules, with a 10 m 2 detection area per module. In this paper, a new generation of detectors, replacing the current multi-pixel photomultiplier tube (PMT) with silicon photo sensors (aka. SiPMs), is proposed. The selection of the new device and its front-end electronics is explained. A method to calibrate the counting system that ensures the performance of the detector is detailed. This method has the advantage of being able to be carried out in a remote place such as the one where the detectors are deployed. High efficiency results, i.e. 98% efficiency for the highest tested overvoltage, combined with a low probability of accidental counting (~2%), show a promising performance for this new system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantification of Technetium-99 in Complex Groundwater Matrixes using a Radiometric Preconcentrating Minicolumn Sensor in an Equilibration-based Sensing Approach

A preconcentrating minicolumn sensor for pertechnetate detection in water consists of a packed bed containing a mixture of anion exchange resin and scintillating plastic beads. The column materials are contained in a transparent plastic flow cell placed between two photomultiplier tubes for radiometric detection. Upon retention of pertechnetate anions, the radioactive decay of Tc-99 results in detectable scintillation pulses that are counted in coincidence. In equilibration-based sensing mode, the sample is pumped through the packed bed until complete chromatographic equilibrium is achieved between the activity concentration in the water sample and the concentration on the anion exchange resin. The analytical signal is the observed steady state count rate at equilibrium. The sensitivity is related to a measurement efficiency parameter that is the product of the retention volume and the absolute radiometric detection efficiency. This sensor can readily detect pertechnetate to levels ten times below the drinking water standard of 0.033 Bq/mL. The potential for other anions in natural groundwater and contaminated groundwater plumes to interfere with pertechnetate detection and quantification have been examined in detail, with reference to the groundwater chemistry at the Hanford Site in Washington State. Individual anions such as nitrate, carbonate, chloride and iodide, at natural or elevated concentrations, do not interfere significantly with pertechnetate uptake on the anion exchange resin. Elevated chromate or sulfate anion concentrations can interfere with pertechnetate uptake by the resin, but only at levels substantially higher than typical concentrations in groundwater or contamination plumes. Nevertheless, elevated anion concentrations may reduce pertechnetate uptake and sensitivity of the sensor when present in combination. Chromate is retained on the anion exchange resin from water at ppb levels, leading to an orange stain that interferes with pertechnetate detection by the absorption of scintillation light pulses (color quench). Radioactivity from radioiodine, tritium, and uranium are not expected to create a significant positive bias in groundwater analyses. A method of automated fluidic standard addition is demonstrated that corrects for matrix interferences leading to accurate analyses over a wide range of groundwater compositions.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Detection of Isotopes in Urban Source Search Gamma Spectra Using Hopfield Neural Network

Source search campaigns involve the measurement of consecutive background gamma-ray spectra obtained with a mobile detector-spectrometer, such as tellurium-doped sodium iodide NaI(Tl) scintillator detector-spectrometer. Counts are measured with NaI(Tl) detector in short acquisition intervals, such as one second. Detection of isotopes in search data is challenging because of the low signal-to-noise ratio (S/N) of the spectral lines and highly varying background due to naturally occurring radioactive material (NORM). In this work, we investigate the performance of the detection of orphan Cs-137, Am-241, and I-131 isotopes in a gamma ray data set obtained in a search survey. Isotopic detection is performed with a Hopfield Neural Network (HNN), which implements an auto-associative memory by matching incoming measurements to the closest one of its memory-stored signature patterns. HNN is trained on examples of spectra of calibrated isotopic sources with well-resolved spectral lines. During testing, HNN processes spectra with partially complete or distorted isotopic lines. The performance of the HNN detection algorithm is benchmarked with Precision, Recall, and F1 scores. Test results demonstrate the potential of HNN to detect the isotope of interest with high accuracy (F1 > 90%) for all isotopes in this study.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillator-based Timepix3 detector for neutron spin-echo techniques using intensity modulation

A scintillator-based Timepix3 (TPX3) detector was developed to resolve the high-frequency modulation of a neutron beam in both spatial and temporal domains, as required for neutron spin-echo experiments. In this system, light from a scintillator is manipulated with an optical lens and is intensified using an image intensifier, making it detectable with the TPX3 chip. Two different scintillators, namely, 6 LiF:ZnS(Ag) and 6 LiI:Eu, were investigated to achieve the high resolution needed for spin-echo modulated small-angle neutron scattering (SEMSANS) and modulation of intensity with zero effort (MIEZE). The methodology for conducting event-mode analysis is described, including the optimization of clustering parameters for both scintillators. The detector with both scintillators was characterized with respect to detection efficiency, spatial resolution, count rate, uniformity, and γ-sensitivity. The 6 LiF:ZnS(Ag) scintillator-based detector achieved a spatial resolution of 200 μm and a count rate capability of 1.1 × 10 5 cps, while the 6 LiI:Eu scintillator-based detector demonstrated a spatial resolution of 250 μm and a count rate capability exceeding 2.9 × 10 5 cps. Furthermore, high-frequency intensity modulations in both spatial and temporal domains were successfully observed, confirming the suitability of this detector for SEMSANS and MIEZE techniques, respectively.

47 OTHER INSTRUMENTATION↗

The Use of Energy Information in Plastic Scintillator Material

Plastic scintillator material is often used for gamma-ray detection in many applications due to its relatively good sensitivity and cost-effectiveness compared to other detection materials. However, due to the dominant Compton scattering interaction mechanism, full energy peaks are not observed in plastic scintillator spectra and isotopic identification is impossible. Typically plastic scintillator detectors are solely gross count detectors. In some safeguards and security applications, such as radiation portal monitors for vehicle screening, naturally-occurring radioactive material (NORM) often triggers radiation alarms and results in innocent or nuisance alarms. The limited energy information from plastic scintillator material can be used to discriminate the NORM from targeted materials and reduce the nuisance alarm rate. An overview of the utilization of the energy information from plastic scintillator material will be presented, with emphasis on the detection capabilities and potential limitations for safeguards and security applications. (PIET-43741-TM-490)

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Prototype muon detectors for the AMIGA component of the Pierre Auger Observatory

AMIGA (Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory to extend its range of detection and to directly measure the muon content of the particle showers. It consists of an infill of surface water-Cherenkov detectors accompanied by buried scintillator detectors used for muon counting. The main objectives of the AMIGA engineering array, referred to as the Unitary Cell, are to identify and resolve all engineering issues as well as to understand the muon-number counting uncertainties related to the design of the detector. The mechanical design, fabrication and deployment processes of the muon counters of the Unitary Cell are described in this document. These muon counters modules comprise sealed PVC casings containing plastic scintillation bars, wavelength-shifter optical fibers, 64 pixel photomultiplier tubes, and acquisition electronics. The modules are buried approximately 2.25 m below ground level in order to minimize contamination from electromagnetic shower particles. The mechanical setup, which allows access to the electronics for maintenance, is also described in addition to tests of the modules' response and integrity. As a result, the completed Unitary Cell has measured a number of air showers of which a first analysis of a sample event is included here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deployment of ADTimePix3 areaDetector Driver at Neutron and X-ray User Facilities

TimePix3 is a 65k hybrid pixel readout chip with simultaneous Time-of-Arrival (ToA) and Time-over-Threshold (ToT) recording in each pixel*. The chip operates without a trigger signal with a sparse readout where only pixels containing events are read out. The flexible architecture allows 40 MHits/s/cm² readout throughput, using simultaneous readout and acquisition by sharing readout logic with transport logic of superpixel matrix formed using 2x4 structure. The chip ToA records 1.5625 ns time resolution. The X-ray and charged particle events are counted directly. However, indirect neutron counts use 6Li fission in a scintillator matrix, such as ZnS(Ag). The fission space-charge region is limited to 5-9 um. A photon from scintillator material excites a photocathode electron, which is further multiplied in dual-stack MCP. The neutron count event is a cluster of electron events at the chip. We report on the EPICS areaDetector** ADTimePix3 driver that controls Serval*** using json commands. The driver directs data to storage and to a real-time processing pipeline and configures the chip. The time-stamped data are stored in raw .tpx3 file format and passed through a socket where the clustering software identifies individual neutron events. The conventional 2D images are available as images for each exposure frame, and a preview is useful for sample alignment. The areaDetector driver allows integration of time-enhanced capabilities of this detector into SNS beamlines controls and unprecedented time resolution.

Gofron, Kaz↗

Development of Labview based data acquisition and multichannel analyzer software for radioactive particle tracking system

A DAQ (data acquisition) software called RPTv2.0 has been developed for Radioactive Particle Tracking System in Malaysian Nuclear Agency. RPTv2.0 that features scanning control GUI, data acquisition from 12-channel counter via RS-232 interface, and multichannel analyzer (MCA). This software is fully developed on National Instruments Labview 8.6 platform. Ludlum Model 4612 Counter is used to count the signals from the scintillation detectors while a host computer is used to send control parameters, acquire and display data, and compute results. Each detector channel consists of independent high voltage control, threshold or sensitivity value and window settings. The counter is configured with a host board and twelve slave boards. The host board collects the counts from each slave board and communicates with the computer via RS-232 data interface.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radiochemical Separation and Quantification of Tritium in Metallic Radwastes Generated from CANDU Type NPP - 13279

As a destructive quantification method of {sup 3}H in low and intermediate level radwastes, bomb oxidation, sample oxidation, and wet oxidation methods have been introduced. These methods have some merits and demerits in the radiochemical separation of {sup 3}H radionuclides. That is, since the bomb oxidation and sample oxidation methods are techniques using heating at high temperature, the separation methods of the radionuclides are relatively simple. However, since {sup 3}H radionuclide has a property of being diffused deeply into the inside of metals, {sup 3}H which is distributed on the surface of the metals can only be extracted if the methods are applied. As an another separation method, the wet oxidation method makes {sup 3}H oxidized with an acidic solution, and extracted completely to an oxidized HTO compound. However, incomplete oxidized {sup 3}H compounds, which are produced by reactions of acidic solutions and metallic radwastes, can be released into the air. Thus, in this study, a wet oxidation method to extract and quantify the {sup 3}H radionuclide from metallic radwastes was established. In particular, a complete extraction method and complete oxidation method of incomplete chemical compounds of {sup 3}H using a Pt catalyst were studied. The radioactivity of {sup 3}H in metallic radwastes is extracted and measured using a wet oxidation method and liquid scintillation counter. Considering the surface dose rate of the sample, the appropriate size of the sample was determined and weighed, and a mixture of oxidants was added to a 200 ml round flask with 3 tubes. The flask was quickly connected to the distilling apparatus. 20 mL of 16 wt% H{sub 2}SO{sub 4} was given into the 200-ml round flask through a dropping funnel while under stirring and refluxing. After dropping, the temperature of the mixture was raised to 96 deg. C and the sample was leached and oxidized by refluxing for 3 hours. At that time, the incomplete oxidized {sup 3}H compounds were completely oxidized using the Pt catalysts and produced a stable HTO compound. After that, about a 20 ml solution was distilled in the separation apparatus, and the distillate was mixed with an ultimagold LLT as a cocktail solution. The solution in the vial was left standing for at least 24 hours. The radioactivity of {sup 3}H was counted directly using a liquid scintillation analyzer (Packard, 2500 TR/AB, Alpha and Beta Liquid Scintillation Analyzer). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measurements of temporally- and spatially-resolved neutron production in a sheared-flow stabilized Z-pinch

A novel approach using multiple scintillator detectors is applied to measure temporally- and spatially-resolved neutron production in the Fusion Z-pinch Experiment (FuZE) device, a Sheared-Flow Stabilized (SFS) Z-pinch. Diagnosing neutron production from FuZE is important for determining if fusion is thermonuclear and whether the FuZE device can be scaled toward reactor conditions. Absolute yields of up to 2 × 10 5 neutrons per discharge are measured with calibrated plastic scintillator detectors operating in pulse-counting mode. Neutron emission durations of up to ~8 μs are inferred by recording the time difference between the first and last pulses for each discharge. Multiple scintillator detectors located at different positions with respect to the fusing plasma are used to demonstrate that the axial extent of the neutron producing region is comparable to the device volume. Scintillator detectors are well-suited as neutron diagnostics for FuZE and other plasma devices with similar yields and emission durations. Increasing the neutron yield, duration, and volume of the neutron emitting region within the plasma column are significant experimental objectives for FuZE.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Identification of background limitations to ultra-sensitive $\mathrm{LSC}$ counting through $\mathrm{ICP}$-$\mathrm{MS}$ assay of $\mathrm{LSC}$ cocktails

We report the performance of LSC cocktails in ultra-sensitive applications was evaluated. Backgrounds from radioactive contaminations in commercially available and in-house developed liquid scintillation cocktails were measured and compared to the predicted background levels of the ultra-low background liquid scintillation counter. Through the ICP-MS assay of the cocktails and their constituents, potassium impurities in the surfactant component were identified as a significant source of background, potentially limiting the use of LSC counting in ultra-sensitive applications. This work lays the groundwork for future research towards ultrapure LSC cocktails for ultrasensitive LSC counting

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A CZT-based radioxenon detection system in support of the Comprehensive Nuclear-Test-Ban Treaty

Here in this work, a prototype radioxenon detection system was designed, developed and tested at Oregon State University to study the response of CdZnTe (CZT) detectors to xenon radioisotopes for monitoring nuclear explosions. The detector utilizes two coplanar CZT detectors and measures xenon radioisotopes through beta-gamma coincidence detection between the two detection elements. The CZT-based detection system offers excellent energy resolution and background count rate compared with scintillator-based beta-gamma coincidence detectors currently in operation at the IMS stations. In this paper, we briefly discuss the detector design and report our recent measurement results with 131mXe, 133mXe, and 133Xe produced in the TRIGA reactor at OSU.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗