Search NASA⌕ Search

SEARCH · Search NASA

Results for “SILICON RADIATION DETECTORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

SiC Charged Particle Telescope GRC Independent Research and Development (IRAD) Program End of Project Final Report

In an advancement over the state-of-the art, NASA Glenn Research Center (GRC) has developed a large area silicon carbide (SiC)-based charged particle telescope through an Independent Research and Development (IRAD) project. The telescope has been demonstrated to have improved noise characteristics and resolution than previous SiC detectors. This improvement will meet the challenges of compact multidirectional robust radiation detector systems to study a wide range of elementary particle mass and energies. In order to provide a complete understanding of how energetic processes internal and external to the solar system shape magnetospheres, atmospheres, and surfaces, in situ particle observations should include measurements of Solar Energetic Particles (SEP) and Galactic Cosmic Rays (GCR), along with solar wind and plasma. The potential temperature stability, tolerance to high radiation environments, and low noise characteristics expected in SiC-based detectors can have advantages over the state-of-the-art silicon detectors. These advantages will allow the detectors to be deployed in small compact systems on a variety of platforms, enabling compact structures for small satellite platforms with improved data quality.

Field and particle detectors↗

Extracting the electronic structure of light elements in bulk materials through a Compton scattering method in the readily accessible hard x-ray regime

Here, our Compton profile measurements of Ti and TiH 2 using readily available hard X-ray radiation at 27.5 keV, detected by both a Hitachi Vortex silicon-drift detector and a high-resolution superconducting transition-edge sensor array, are found to be in excellent accord with state-of-the-art density functional theory based calculations. The spherically averaged difference between the Compton profiles of TiH 2 and Ti is well described by an inverted parabola, supporting an itinerant behavior of the electron gas screening the protons in the Ti matrix. Our experimental approach, validated by two different detectors, extends the applicability of Compton scattering technique to the readily accessible hard x-ray regime (below 30 keV). Our study suggests possibilities for experiments at low-flux bending magnet synchrotron beamlines and paves the way for the development of tabletop Compton experiments with x-ray tubes.

36 MATERIALS SCIENCE↗

Compact radiation detector

Apparatus for detecting radiation includes a sensor medium disposed within a cavity in a silicon-based substrate. An electrode arrangement is provided for collecting charge generated within the sensor medium by interactions with impinging radiation and drifted through the sensor medium. The electrode arrangement is constituted, in part, by a silicon portion of the substrate that is doped to increase its electrical conductivity and that defines part of the cavity wall.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of LET distribution and dose equivalent onboard the Space Shuttle IML-2 (STS-65) and S/MM#4 (STS-79)

Space radiation dosimetry measurements have been made onboard the Space Shuttle STS-65 in the Second International Microgravity Laboratory (IML-2: 28.5 degrees x 300 km: 14.68 days) and the STS-79 in the 4th Shuttle MIR mission (S/MM#4: 51.6 degrees x 300-400km: 10.2 days). In these measurements, three kinds of detectors were used; one is a newly developed active detector telescope called "Real-time Radiation Monitoring Device (RRMD-I for IML-2 and RRMD-II with improved triggering system for S/MM#4)" utilizing silicon semi-conductor detectors and the other detectors are conventional passive detectors of thermoluminescence dosimeters (TLDs) and CR-39 plastic track detectors. The main contribution to dose equivalent for particles with LET > 5.0 keV/micrometer (IML-2) and LET > 3.5 keV/micrometer (S/MM#4) is seen to be due to galactic cosmic rays (GCRs) and the contribution of the South Atlantic Anomaly (SAA) is less than 5% (IML-2: 28.5 degrees x 300 km) and 15% (S/MM#4: 51.6 degrees x 400 km) in the above RRMD LET detection conditions. For the whole LET range (> 0.2 kev/micrometer) obtained by TLDs and CR-39 in these two typical orbits (a small inclination x low altitude and a large inclination x high altitude), absorbed dose rates range from 94 to 114 microGy/day, dose equivalent rates from 186 to 207 microSv/day and average quality factors from 1.82 to 2.00 depending on the locations and directions of detectors inside the Spacelab at the highly protected IML-2 orbit (28.5 degrees x 300 km), and also, absorbed dose rates range from 290 to 367 microGy/day, dose equivalent rates from 582 to 651 microSv/day and average quality factors from 1.78 to 2.01 depending on the dosimeter packages around the RRMD-II "Detector Unit" at the S/MM#4 orbit (5l.6 degrees x 400km). In general, it is seen that absorbed doses depend on the orbit altitude (SAA trapped particles contribution dominant) and dose equivalents on the orbit inclination (GCR contribution dominant). The LET distributions obtained by two different types of active and passive detectors, RRMDs and CR-39, are in good agreement for LET of 15 - 200 kev/micrometer and difference of these distributions in the regions of LET < 15 kev/micrometer and LET > 200 kev/micrometer can be explained by considering characteristics of CR-39 etched track formation especially for the low LET tracks and chemical etching conditions.

manned↗

Application of real-time radiation dosimetry using a new silicon LET sensor

A new type of real-time radiation monitoring device, RRMD-III, consisting of three double-sided silicon strip detectors (DSSDs), has been developed and tested on-board the Space Shuttle mission STS-84. The test succeeded in measuring the linear energy transfer (LET) distribution over the range of 0.2 keV/micrometer to 600 keV/micrometer for 178 h. The Shuttle cruised at an altitude of 300 to 400 km and an inclination angle of 51.6 degrees for 221.3 h, which is equivalent to the International Space Station orbit. The LET distribution obtained for particles was investigated by separating it into galactic cosmic ray (GCR) particles and trapped particles in the South Atlantic Anomaly (SAA) region. The result shows that the contribution in dose-equivalent due to GCR particles is almost equal to that from trapped particles. The total absorbed dose rate during the mission was 0.611 mGy/day; the effective quality factor, 1.64; and the dose equivalent rate, 0.998 mSv/day. The average absorbed dose rates are 0.158 mGy/min for GCR particles and 3.67 mGy/min for trapped particles. The effective quality factors are 2.48 for GCR particles and 1.19 for trapped particles. The absorbed doses obtained by the RRMD-III and a conventional method using TLD (Mg(2)SiO(4)), which was placed around the RRMD-III were compared. It was found that the TLDs showed a lower efficiency, just 58% of absorbed dose registered by the RRMD-III.

NASA Discipline Radiation Health↗

Response of Silicon-Based Linear Energy Transfer Spectrometers: Implication for Radiation Risk Assessment in Space Flights

There is considerable interest in developing silicon-based telescopes because of their compactness and low power requirements. Three such telescopes have been flown on board the Space Shuttle to measure the linear energy transfer spectra of trapped, galactic cosmic ray, and solar energetic particles. Dosimeters based on single silicon detectors have also been flown on the Mir orbital station. A comparison of the absorbed dose and radiation quality factors calculated from these telescopes with that estimated from measurements made with a tissue equivalent proportional counter show differences which need to be fully understood if these telescopes are to be used for astronaut radiation risk assessments. Instrument performance is complicated by a variety of factors. A Monte Carlo-based technique was developed to model the behavior of both single element detectors in a proton beam, and the performance of a two-element, wide-angle telescope, in the trapped belt proton field inside the Space Shuttle. The technique is based on: (1) radiation transport intranuclear-evaporation model that takes into account the charge and angular distribution of target fragments, (2) Landau-Vavilov distribution of energy deposition allowing for electron escape, (3) true detector geometry of the telescope, (4) coincidence and discriminator settings, (5) spacecraft shielding geometry, and (6) the external space radiation environment, including albedo protons. The value of such detailed modeling and its implications in astronaut risk assessment is addressed. c2001 Elsevier Science B.V. All rights reserved.

manned↗

Radiation tolerance studies of the HV-mux GaNFETs for the HL-LHC ATLAS ITk Strip detector

For the High-Luminosity upgrade of the LHC, the current ATLAS inner detector will be replaced with a new silicon charged-particle tracker, the ITk, which consists of the ITk Pixel and the ITk Strip subdetector. The high voltage multiplexing (HV-Mux) GaNFETs are radiation-tolerant transistors that permit switching off high voltage to malfunctioning sensors on the ITk Strip modules. To ensure the reliability of the GaNFETs in the high radiation environment expected at the HL-LHC, a sample of the production batch was exposed to gamma radiation. Finally, the GaNFETs were characterized pre-irradiation and post-irradiation, and monitored during irradiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The STAR Forward Silicon Tracker

The Forward Silicon Tracker (FST) is a pivotal component of the forward upgrade of the Solenoidal Tracker at RHIC (STAR), designed to discern hadron charge signs with a momentum resolution better than 30% for 0.2 < p T < 2GeV/c in the 2.5 < η < 4 pseudorapidity range. Its compact design features three disks along the beam direction, minimized material budget, and scattering effects. The FST uses Hamamatsu’s p-in-n silicon strip sensors with a double metal layer that enables efficient signal routing to the readout electronics, enhancing overall detector performance. The flexible hybrid boards, essential for the readout system, are constructed with Kapton and copper layers to optimize signal handling and power distribution. These boards connect silicon strips to analogue pipeline ASIC APV25-S1 chips, which read up to 128 channels each. A cooling system with nonconducting, volatile NOVEC 7200 coolant at 22.2 °C mitigates ASIC-generated heat. Furthermore, the FST enhances forward tracking performance at STAR as an integral part of the forward upgrade.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation of radiation hardness of semiconductor materials against alpha particles for an API detector

An Associated Particle Imaging (API) system consists of a high vacuum chamber where deuterium ions are accelerated on a tritium-loaded target, resulting in alpha particles and neutrons emitted back-to-back, the latter escaping the chamber and used, for example, for tomography of a high-Z sample. An accurate determination of the alpha position is crucial to determine the trajectory of the neutron. Existing API systems have several limitations which a semiconductor-based API detector placed inside the vacuum chamber should not present. The semiconductor material can be either silicon or diamond. In particular, large and fast signals are generated by the alpha interactions in these materials. A pixelated API detector will measure the time and hit position of the alphas produced in the reaction. However, during the lifetime of the generator, the semiconductor detector will be exposed to an intense flux of alpha particles that will degrade its performance over time. To assess the radiation hardness of silicon and diamond against the alpha particles, we exposed single diodes made of either of the two materials to a 5 MeV alpha flux generated by an 241Am radioactive source. During irradiation, the diodes were biased and mounted on current-sensitive preamplifier boards. We have therefore been able to measure insitu the evolution of the waveforms as the damage was accumulating in their substrates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel indium phosphide charged particle detector characterization with a 120 GeV proton beam

Thin film detectors which incorporate semiconductor materials other than silicon have the potential to build upon their unique material properties and offer advantages such as faster response times, operation at room temperature, and radiation hardness. To explore the possibility, promising candidate materials were selected, and particle tracking detectors were fabricated. An indium phosphide detector with a metal-intrinsic-metal structure has been fabricated for particle tracking. The detector was tested using radioactive sources and a high energy proton beam at Fermi National Accelerator Laboratory. In addition to its simplistic design and fabrication process, the indium phosphide particle detector showed a very fast response time of hundreds of picoseconds for the 120 GeV protons, which are comparable to the ultra-fast silicon detectors. This fast-timing response is attributed to the high electron mobility of indium phosphide. Such material properties can be leveraged to build novel detectors with superlative performance.

47 OTHER INSTRUMENTATION↗

Forward silicon vertex/tracking detector design and R$\&$D for the future Electron-Ion Collider

The proposed high-luminosity high-energy Electron-Ion Collider (EIC) will provide a clean environment to precisely study several fundamental questions in the fields of high-energy and nuclear physics . A low material budget and high granularity silicon vertex/tracking detector is critical to carry out a series of hadron and jet measurements at the future EIC especially for the heavy flavor product reconstruction or tagging. The conceptual design of a proposed forward silicon tracking detector with the pseudorapidity coverage from 1.2 to 3.5 has been developed in integration with different magnet options and the other EIC detector sub-systems. The tracking performance of this detector enables precise heavy flavor hadron and jet measurements in the hadron beam going direction. The detector R&D for the proposed silicon technology candidates: Low Gain Avalanche Diode (LGAD) and radiation hard depleted Monolithic Active Pixel Sensor (MALTA), which can provide good spatial and timing resolutions, is underway. Bench test results of the LGAD and MALTA prototype sensors will be discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

THz Hot-Electron Photon Counter

We present a concept for the hot-electron transition-edge sensor capable of counting THz photons. The main need for such a sensor is a spectroscopy on future space telescopes where a background limited NEP approx. 10(exp -20) W/H(exp 1/2) is expected at around 1 THz. Under these conditions, the rate of photon arrival is very low and any currently imaginable detector with sufficient sensitivity will operate in the photon counting mode. The Hot-Electron Photon Counter based on a submicron-size Ti bridge has a very low heat capacity which provides a high enough energy resolution (approx.140 GHz) at 0.3 K. With the sensor time constant of a few microseconds, the dynamic range would be approx. 30 dB. The sensor couples to radiation via a planar antenna and is read by a SQUID amplifier or by a 1-bit RSFQ ADC. A compact array of the antenna-coupled counters can be fabricated on a silicon wafer without membranes.

radiation detectors↗

SiC As An Energetic Particle Detector

Several new technologies have been introduced recently in the region of semiconductor material for solid state detectors (SSD). Of particular interest is silicon carbide (SIC) since its band gap is larger than that of pure silicon, reducing its dark current and making SIC capable of operating at high temperatures and more tolerant of radiation damage. But the trade off is that a higher band gap also means fewer electron hole pairs generated, and thus a smaller signal, for detecting incident radiation. To determine what the lower limit of SiC detectors to energetic particles is, we irradiated a SiC diode with particles ranging in energy from 50 keV to 1.6 MeV and masses from 1 to 16 amu. We found that the SiC detectors sensitivity was comparable to that of pure silicon, with the SiC detector being able to measure particles down to 50 keV/amu and possibly lower.

Yan, F.↗

Radiation Measured during ISS-Expedition 13 with Different Dosimeters

Radiation in low Earth orbit (LEO) is mainly composed of Galactic Cosmic Rays (GCR), solar energetic particles and particles in SAA (South Atlantic Anomaly). The biological impact of space radiation to astronauts depends strongly on the particles linear energy transfer (LET) and is dominated by high LET radiation. It is important to measure the LET spectrum for the space radiation field and to investigate the influence of radiation on astronauts. At present, the preferred active dosimeters sensitive to all LET are the tissue equivalent proportional counter (TEPC) and silicon detectors in various configurations; the preferred passive dosimeters are thermoluminescence dosimeters (TLDs) and optically stimulated luminescence dosimeters (OSLDs) sensitive to low LET as well as CR-39 plastic nuclear track detectors (PNTDs) sensitive to high LET. The TEPC, CR-39 PNTDs, TLDs and OSLDs were used to investigate the radiation exposure for the ISS mission Expedition 13 (ISS-12S) in LEO. LET spectra and radiation quantities (fluence, absorbed dose, dose equivalent and quality factor) were measured for the space mission with different dosimeters. This paper introduces the operational principles for the dosimeters, describes the method to combine the results measured by TLDs/OSLDs and CR-39 PNTDs, and presents the LET spectra and the radiation quantities measured. Keywords: space radiation; cosmic rays; active and passive dosimeters; LET spectra

Zhou, D.↗

A new waveform analysis technique to extract good energy and position resolution from a dual-axis duo-lateral position-sensitive detector

The dual-axis duo-lateral position-sensitive silicon detector was developed to detect charged particles with high quality position and energy resolution. When these detectors were used with conventional signal processing electronics, an empirically determined correction was used to improve energy resolution. In this work, the waveforms from the detector after preamplification are studied in detail to investigate position information contained in the waveforms. A 7.22 MeV/nucleon alpha particle beam was impinged directly on a masked dual-axis duo-lateral detector. Data obtained using a 228 Th alpha particle source was also used. Here, by studying the waveform characteristics that give rise to the position-dependent distortions, a new summed trigger analysis method has been developed to significantly improve linearity in position reconstruction without sacrificing energy resolution.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗