Compact Microwave Mercury Ion Clock for Space Applications

We review progress in developing a small Hg ion clock for space operation based on breadboard ion-clock physics package where Hg ions are shuttled between a quadrupole and a 16-pole rf trap. With this architecture we have demonstrated short-term stability approx.1-2x10(exp -13) at 1 second, averaging to 10-15 at 1 day. This development shows that H-maser quality stabilities can be produced in a small clock package, comparable in size to an ultra-stable quartz oscillator required or holding 1-2x10(exp -13) at 1 second. We have completed an ion clock physics package designed to withstand vibration of launch and are currently building a approx. 1 kg engineering model for test. We also discuss frequency steering software algorithms that simultaneously measure ion signal size and lamp light output, useful for long term operation and self-optimization of microwave power and return engineering data.

navigation↗

Performance of the GLAS Space Lidar Receiver Through Its Seven-Year Space Mission

NASA s Ice, Cloud, and land Elevation Satellite (ICESat) mission [1,2] carrying the Geoscience Laser Altimeter System (GLAS) Instrument, was launched on January 12, 2003. The three lasers on ICESat have made a total of 1.98 billion laser shot measurements of the Earth s surface and atmosphere during its 17 science data collection campaigns over its seven year operating lifetime. ICESat completed its science mission after the last laser stopped operating in October 2009. The spacecraft was de-orbited on August 30, 2010. The GLAS instrument carried 3 diode-pumped Q-switched Nd:YAG lasers, which emitted 6-nsec wide pulses at 1064 and 532 nm at a 40-Hz rate. There are three lidar receiver channels, a 1064 nm surface altimetry channel, a 1064 nm cloud backscattering lidar channel, and a 532 nm cloud and aerosol backscattering lidar channel. The altimetry and cloud backscatter channels used Si avalanche photodiode (APD) operated in analog mode as in the Mars Global Surveyor s Mars Orbital Laser Altimeter [3,4]. GLAS also utilized a number of new technologies and techniques for space lidar, including passively Q-switched diode-pumped Nd:YAG lasers, a 1-m diameter telescope, a temperature tuned etalon optical bandpass filter, Si APD single photon counting detectors, 1 Gsample/sec waveform digitizers, ultra stable clock oscillators, and digital signal processing and detection algorithms [5]. A global position system (GPS) receiver was used to provide the spacecraft position and epoch times. The ICESat mission provided a unique opportunity to monitor the lidar component performance in the space environment over a multi-year time period. We performed a number of engineering tests periodically to monitor the lidar receiver performance, including receiver sensitivity, timing precision, detector dark noise, etc. A series of engineering tests were also performed after the end of the science mission to evaluate the performance of the spare detector, oscillator, waveform digitizer, and GPS receiver. An experiment was conducted which pointed GLAS to Venus to test the receiver sensitivity to star light and to verify GLAS bore sight with respect to the spacecraft coordinate system. These tests provided unique data to assess the degradation and the rate of change of these key lidar components due to space radiation and aging. They also helped to validate new techniques to operate and calibrate future space lidars.

Sun, Xiaoli↗

Flight-Like Optical Reference Cavity for GRACE Follow-On Laser Frequency Stabilization

We describe a prototype optical cavity and associated optics that has been developed to provide a stable frequency reference for a future space-based laser ranging system. This instrument is being considered for inclusion as a technology demonstration on the recently announced GRACE follow-on mission, which will monitor variations in the Earth's gravity field.

Gravity Recovery and Climate Experiment (GRACE)↗

Progress on Small Mercury Ion Clock for Space Applications

We have recently completed a breadboard ion-clock physics package based on Hg ions shuttled between a quadrupole and a 16-pole rf trap. With this architecture we have demonstrated short-term stability approx.1-2x10-(sup 1)(sup 3) at 1 second, averaging to 10-(sup 1)? at 1 day. This development shows that H-maser quality stabilities can be produced in a small clock package, comparable in size to an ultra-stable quartz oscillator required for holding 1-2x10-(sup 1)(sup 3) at 1 second. This performance was obtained in a sealed vacuum configuration where only a getter pump was used to maintain vacuum. The vacuum tube containing the traps has now been under sealed vacuum conditions for over three years with no measurable degradation of ion trapping lifetimes or clock short-term performance. We have fabricated the vacuum tube, ion trap and UV windows from materials that will allow approx. 400 deg C bake-out to prepare for tube seal-off. This approach to the vacuum follows the methods used in flight vacuum tube electronics, such as flight TWTA's where tube operation lifetime and shelf life of up to 15 years is achieved.

positioning↗

Compact Microwave Mercury Ion Clock for Space Applications

We have recently completed a breadboard ion-clock physics package based on Hg ions shuttled between a quadrupole and a 16-pole rf trap. With this architecture we have demonstrated short-term stability approximately 1 - 2 x 10(exp -13) at 1 second, averaging to 10(exp -15) at 1 day. This development shows that H-maser quality stabilities can be produced in a small clock package, comparable in size to an ultra-stable quartz oscillator required for holding 1 - 2 x 10(exp -13) at 1 second. This performance was obtained in a sealed vacuum configuration where only a getter pump was used to maintain vacuum. The vacuum tube containing the traps has now been under sealed vacuum conditions for nearly three years with no measurable degradation of ion trapping lifetimes or clock short-term performance. We have fabricated the vacuum tube, ion trap and UV windows from materials that will allow an approximately 400 C bake-out to prepare for tube seal-off. This approach to the vacuum follows the methods used in flight vacuum tube electronics, such as flight TWTA's where tube operation lifetime and shelf life of up to 15 years is achieved.

Atomic Clock↗

Ultra-stable, low phase noise dielectric resonator stabilized oscillators for military and commercial systems

EPSD has designed, fabricated and tested, ultra-stable, low phase noise microwave dielectric resonator oscillators (DRO's) at S, X, Ku, and K-bands, for potential application to high dynamic range and low radar cross section target detection radar systems. The phase noise and the temperature stability surpass commercially available DROs. Low phase noise signals are critical for CW Doppler radars, at both very close-in and large offset frequencies from the carrier. The oscillators were built without any temperature compensation techniques and exhibited a temperature stability of 25 parts per million (ppm) over an extended temperature range. The oscillators are lightweight, small and low cost compared to BAW & SAW oscillators, and can impact commercial systems such as telecommunications, built-in-test equipment, cellular phone and satellite communications systems. The key to obtaining this performance was a high Q factor resonant structure (RS) and careful circuit design techniques. The high Q RS consists of a dielectric resonator (DR) supported by a low loss spacer inside a metal cavity. The S and the X-band resonant structures demonstrated loaded Q values of 20,300 and 12,700, respectively.

Mizan, Muhammad↗

Radar Back End for NASA/ISRO Synthetic Aperture Radar (NISAR) Instrument

In this paper we present design, manufacture and qualification of a Radar Back End (RBE) for NISAR Mission’s Synthetic Aperture Radar (SAR) Instrument. The instrument uses Sweep SAR technique to generate high fidelity radar images while capturing an image over a large swath. It requires highly stable clocks to accomplish that. NISAR RBE is the heart of the L-band Synthetic Aperture Radar (LSAR) instrument. It generates radar’s transmit chirp signals, ultra-stable clocks and oscillators signals. In order to generate ultra-stable clocks some novel filtering and frequency multiplication techniques were utilized. These techniques have been presented in this paper. NISAR mission requires over 200 chirps to perform science measurements. Hardware and firmware architecture utilized to generate chirps have been presented in this paper. Unique space qualified techniques for DC to DC conversion has been presented in this paper. In addition, RBE was designed to be block redundant space qualified assembly. Novel cross strapping techniques were implemented to achieve that. Validation and qualification process employed to certify RBE flight hardware for flight has been presented in this paper.

Quddus, Momin↗

A Theoretical Investigation of Longitudinal Stability of Airplanes with Free Controls Including Effect of Friction in Control System

The relation between the elevator hinge moment parameters and the control forces for changes in forward speed and in maneuvers is shown for several values of static stability and elevator mass balance. The stability of the short period oscillations is shown as a series of boundaries giving the limits of the stable regions in terms of the elevator hinge moment parameters. The effects of static stability, elevator moment of inertia, elevator mass unbalance, and airplane density are also considered. Dynamic instability is likely to occur if there is mass unbalance of the elevator control system combined with a small restoring tendency (high aerodynamic balance). This instability can be prevented by a rearrangement of the unbalancing weights which, however, involves an increase of the amount of weight necessary. It can also be prevented by the addition of viscous friction to the elevator control system provided the airplane center of gravity is not behind a certain critical position. For high values of the density parameter, which correspond to high altitudes of flight, the addition of moderate amounts of viscous friction may be destabilizing even when the airplane is statically stable. In this case, increasing the viscous friction makes the oscillation stable again. The condition in which viscous friction causes dynamic instability of a statically stable airplane is limited to a definite range of hinge moment parameters. It is shown that, when viscous friction causes increasing oscillations, solid friction will produce steady oscillations having an amplitude proportional to the amount of friction.

Greenberg, Harry↗

Cryo-Cooled Sapphire Oscillator for the Cassini Ka-Band Experiment

We present features for an ultra-stable sapphire cryogenic oscillator which has been designed to support the Cassini Ka-band Radio Science experiment. The design of this standard is new in several respects. It is cooled by a commercial cryocooler instead of liquid cryogens to increase operating time, and it uses a technology to adjust the temperature turn-over point to extend the upper operating temperature limit and to enable construction of multiple units with uniform operating characteristics. Objectives are 3 x 10(exp -15) stability for measuring times 1 second less than or equal to (tau) less than or equal to 100 seconds, phase noise of -85 dBc/Hz from offset frequencies of 1 Hz to 1000 Hz at 10 GHz carrier frequency, and a one year continuous operating period.

Wang, Rabi T.↗

An electronically tuned, stable 8415-MHz dielectric resonator FET oscillator for space applications

A voltage-controlled 8415 MHz FET oscillator stabilized by a dielectric resonator is described. The oscillator provides a linear electronic tuning range of over 3.2 MHz with a flat power output equal to +1.8 dBm (27 C nominal), a single-sideband noise to carrier ratio of -68 dBc/Hz at 1 kHz off carrier, and a frequency temperature coefficient of 0.54 part per million/C over a -24 to 75 C range. The oscillator withstood 150 krads(Si) of gamma radiation with no significant performance degradation. The overall performance of the oscillator is in many ways far superior to that of an equivalent bipolar oscillator for space applications.

Lakshminarayana, M.↗

An electronically tuned, stable 8415 MHz dielectric resonator FET oscillator for space applications

A voltage-controlled 8415-MHz FET oscillator stabilized by a dielectric resonator is described. The oscillator provides over 3.2-MHz linear electronic tuning range with a flat power output equal to +1.8 dBm (27 C, nominal), a single-sideband noise-to-carrier ratio of -68 dBc/Hz at 1 kHz off carrier, and a frequency-temperature coefficient of 0.54 parts per million/C over a -24 C to 75 C range. The oscillator withstood 150 Krads (Si) of gamma radiation with no significant performance degradation. The overall performance of the FET oscillator is far superior in many ways to that of an equivalent bipolar oscillator for space applications. For space applications, the FET dielectric resonator oscillator (DRO) is preferred over bipolar DRO because of its lower DC power consumption, better thermal frequency stability, linear electronic tunability, and higher RF output power capability.

Mysoor, Narayan R.↗

Mini-cavity-dumped laser

Lasers for use in high precision satellite ranging systems consist typically of an oscillator followed by several amplifier stages. While the shortest optical pulses are achieved by using a mode locked oscillator, such an oscillator is incompatible with the compact design needed in future, highly mobile systems. The laser oscillator achieves pulse lengths approaching those obtainable by mode locking, but in a much more compact and stable design. The oscillator uses two LiNbO3 Pockels cells inside the resonator. One Q-switches the oscillator, and the other is used in a pulse slicing scheme to cavity dump a portion of the circulating optical energy. The length of the optical output pulse measured at 425 + or - 50 picoseconds.

Reed, E.↗

InP MMIC Chip Set for Power Sources Covering 80-170 GHz

We will present a Monolithic Millimeter-wave Integrated Circuit (MMIC) chip set which provides high output-power sources for driving diode frequency multipliers into the terahertz range. The chip set was fabricated at HRL Laboratories using a 0.1-micrometer gate-length InAlAs/InGaAs/InP high electron mobility transistor (HEMT) process, and features transistors with an f(sub max) above 600 GHz. The HRL InP HEMT process has already demonstrated amplifiers in the 60-200 GHz range. In this paper, these high frequency HEMTs form the basis for power sources up to 170 GHz. A number of state-of-the-art InP HEMT MMICs will be presented. These include voltage-controlled and fixed-tuned oscillators, power amplifiers, and an active doubler. We will first discuss an 80 GHz voltage-controlled oscillator with 5 GHz of tunability and at least 17 mW of output power, as well as a 120 GHz oscillator providing 7 mW of output power. In addition, we will present results of a power amplifier which covers the full WRIO waveguide band (75-110 GHz), and provides 40-50 mW of output power. Furthermore, we will present an active doubler at 164 GHz providing 8% bandwidth, 3 mW of output power, and an unprecedented 2 dB of conversion loss for an InP HEMT MMIC at this frequency. Finally, we will demonstrate a power amplifier to cover 140-170 GHz with 15-25 mW of output power and 8 dB gain. These components can form a power source in the 155-165 GHz range by cascading the 80 GHz oscillator, W-band power amplifier, 164 GHz active doubler and final 140-170 GHz power amplifier for a stable, compact local oscillator subsystem, which could be used for atmospheric science or astrophysics radiometers.

Ngo, Catherine↗

Rapid oscillations in cataclysmic variables. VII - GK Persei

The discovery of a stable short-period oscillation in the UV light curve of the old nova GK Persei during 1989-91 is reported. The period is consistent with the 351.34-second pulse period seen in hard X-rays, due to the rotation of the white dwarf. In blue light, a quasi-periodic signal appears in the low-frequency wings of the coherent signal. There is evidence for long-term spin-up of the white dwarf; the most probable mean rate is 0.0008 sec/yr.

Patterson, Joseph↗

Laboratory Investigation of Two Autopilots for a 4/10-Scale Drop Model of the Grumman F8F-1 Airplane, TED No. NACA 2466

Performance investigation and frequency response analyses were con- ducted en two autopilot control systems designed for use in the 0.4-scale model of the Grumman F8F-1 airplane. The first system, based on the action of a displacement gyroscope only, was investigated to find the cause of a small-amplitude pitch oscillation which had been noted in previous flight tests. The results of the investigation conducted revealed that, although the autopilot-model combination was dynamically stable, a hunting oscillation was possible due to a change in autopilot characteristics in a dive. This hunting condition can be eliminated by increasing the gyroscope pickoff dead spot without greatly reducing dynamic stability of the autopilot-model combination.

Teitelbaum, Jerome M.↗

Characterizing Observed Limit Cycles in the Cassini Main Engine Guidance Control System

The Cassini spacecraft dynamics-related telemetry during long Main Engine (ME) burns has indicated the presence of stable limit cycles between 0.03-0.04 Hz frequencies. These stable limit cycles cause the spacecraft to possess non-zero oscillating rates for extended periods of time. This indicates that the linear ME guidance control system does not model the complete dynamics of the spacecraft. In this study, we propose that the observed limit cycles in the spacecraft dynamics telemetry appear from a stable interaction between the unmodeled nonlinear elements in the ME guidance control system. Many nonlinearities in the control system emerge from translating the linear engine gimbal actuator (EGA) motion into a spacecraft rotation. One such nonlinearity comes from the gear backlash in the EGA system, which is the focus of this paper. The limit cycle characteristics and behavior can be predicted by modeling this gear backlash nonlinear element via a describing function and studying the interaction of this describing function with the overall dynamics of the spacecraft. The linear ME guidance controller and gear backlash nonlinearity are modeled analytically. The frequency, magnitude, and nature of the limit cycle are obtained from the frequency response of the ME guidance controller and nonlinear element. In addition, the ME guidance controller along with the nonlinearity is simulated. The simulation response contains a limit cycle with similar characterstics as predicted analytically: 0.03-0.04 Hz frequency and stable, sustained oscillations. The analytical and simulated limit cycle responses are compared to the flight telemetry for long burns such as the Saturn Orbit Insertion and Main Engine Orbit Trim Maneuvers. The analytical and simulated limit cycle characteristics compare well with the actual observed limit cycles in the flight telemetry. Both have frequencies between 0.03-0.04 Hz and stable oscillations. This work shows that the stable limit cycles occur due to the interaction between the unmodeled nonlinear elements and linear ME guidance controller.

stable limit cycle↗