Spectral Emittance of Uncoated and Ceramic-Coated Inconel and Type 321 Stainless Steel

The normal spectral emittance of Inconel and type 321 stainless steel with different surface treatments was measured at temperatures of 900, 1,200, 1,500, and 1,800 F over a wavelength range of 1.5 to 15 microns. The measurements involved comparison of the radiant energy emitted by the heated specimen with that emitted by a comparison standard at the same temperature by means of a recording double-beam infrared spectrophotometer. The silicon carbide comparison standard had previously been calibrated against a laboratory black-body furnace. Surface treatments included electropolishing, sandblasting, electro-polishing followed by oxidation in air for 1/2 hour at 1,800 F, sandblasting followed by oxidation in air for 1/2 hour at 1,800 F, application of National Bureau of Standards coating A-418, and application of NBS ceramic coating N-143. The normal spectral emittance of both alloys in the electropolished condition was low and decreased very slightly with increasing wavelength while in the sandblasted condition it was somewhat higher and did not vary appreciably with wavelength. The oxidation treatment greatly increased the normal spectral emittance of both the electropolished and sandblasted type 321 stainless steel specimens and of the electropolished Inconel specimens and introduced some spectral selectivity into the curves. The oxidation increased the normal spectral emittance of the sandblasted Inconel specimens only moderately. Of the specimens to which a coating about 0.002 inch thick was applied, those coated with A-418 had higher emittance at all wavelengths than did those coated with N-143, and the coated specimens of Inconel had higher spectral emittance at all wavelengths than did the corresponding specimens of type 321 stainless steel. Both coatings were found to be partially transparent to the emitted energy at this thickness but essentially opaque at a thickness of 0.005 inch. Coated specimens with 0.005 inch or more of coating did not show the effect of the underlying metal on spectral emittance, and there was no significant difference at wavelengths greater than about five microns in the normal spectral emittance of specimens having the two coatings. At shorter wavelengths the normal spectral emittance of specimens coated with A-418 was greater than that of specimens coated with N-143.

Richmond, Joseph C.↗

The Effects on Non-Actinide Impurities from Aging Heat Source Plutonium in Stainless Steel Containers

Replacing the tantalum vials used for 238 PuO 2 sample collection and storage with stainless steel sample vials has several advantages. These advantages include a decreased cost, better material availability, and ease of fabrication. However, it must first be demonstrated that the alloying elements contained in stainless steel are not leached into the 238 PuO 2 such that product specifications are exceeded. In order to determine the suitability of stainless steel for this application, two seperate 238 PuO 2 fuel lots were investigated. These two fuel lots had been stored in stainless steel containers since their first sampling date of March of 2015, and were again sampled in February of 2019.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Influence of fretting on flexural fatigue of 304 stainless steel and mild steel

Fretting fatigue experiments conducted on 304 stainless steel using a flexural fatigue test arrangement with bolted on fretting pads demonstrated that fatigue life is reduced by at least a factor of 10 in the 265 to 334 MPa (38,500 - to 48,500 psi) nominal flexural fatigue stress range. In addition, experiments in which the fretting pads were removed after selected numbers of cycles, followed by continued flexural fatigue without fretting show that continued fretting beyond 50,000 cycles does not significantly further reduce fatigue life of 304 stainless steel at 317 MPa (46,000 psi). Microscopic examination of the fretted contact areas revealed fracture initiation sites as well as numerous cracks that did not propagate to failure. Flexural fretting fatigue experiments performed on mild steel showed an insensitivity of fatigue life to the incidence of fretting under flexural stress conditions of from 162 to 217 MPa (23,500 to 31,500 psi).

Bill, R. C.↗

The diffusivity of hydrogen in Nb stabilized stainless steel

The evolution of hydrogen from 347 stainless steel has been studied by using a real time dynamic technique under ultrahigh vacuum conditions. Auger electron spectroscopy was used to determine the surface composition as a function of time and temperature. The surface film on the electropolished samples was found to be approximately 15 A thick and consisted of a carbon-oxygen complex and a metal oxide (FexOy). Upon heating to 400 C, the carbon-oxygen complex desorbed as CO and the remaining oxygen and carbon began to incorporate. Also at this temperature sulfur began to diffuse out of the bulk to the surface and at approximately 800 C formed a complete monolayer. At 900 C, carbon and oxygen virtually disappeared, leaving the monolayer of sulfur as the only surface contaminant. The hydrogen diffusivity was found to follow closely the equation D = 7.01 x 10 to the -7th exp(-48.0/RT) sq m per second over the entire temperature range studied, thus indicating that hydrogen evolution is not significantly affected by the changing surface composition. The somewhat higher value of the diffusivity obtained in this work compared to past measurements in austenitic stainless steels may indicate the importance of sample preprocessing and ultrahigh vacuum conditions in minimizing the effects of surface layers.

Outlaw, R. A.↗

Corrosion-induced microstructural developments in 316 stainless steel during exposure to molten Li 2 BeF 4 (FLiBe) salt

The microstructural evaluation and characterization of 316 stainless steel samples that were tested in molten Li 2 BeF 4 (FLiBe) salt were investigated in this study for evaluating its performance in high-temperature molten fluoride salts. Recently, 316 stainless steel and FLiBe salt are being actively considered as the main structural alloy and primary coolant of fluoride salt-cooled high-temperature reactor (FHR), a leading nuclear reactor concept for the next generation nuclear plants (NGNP). In support of the materials development for the FHR, high-temperature corrosion tests of 316 stainless steel in molten FLiBe salt at 700°C have been conducted in both bare graphite crucibles and 316 stainless steel-lined crucibles in an inert atmosphere for up to 3000 hours. The microstructure of the tested samples was comprehensively characterized using scanning electron microscopy (SEM) in conjunction with energy dispersive x-ray spectroscopy (EDS) and electron backscatter diffraction (EBSD), and scanning transmission electron microscopy (STEM) with EDS. In addition to the noticeable intergranular corrosion attack on surface, the corrosion in terms of the Cr depletion along high angle grain boundaries (15-180º) extended to 22µm in depth after 3000-hour exposure to molten FLiBe salt in graphite crucible. The coherent Σ3 grain boundary appeared high resistance to the Cr depletion. The substantial Cr depletion from the near-to-surface layer induced phase transformation from γ-martensite to α-ferrite phase (FeNi x ) during corrosion at 700ºC. Furthermore, the presence of graphite in the molten salt doubled the corrosion attack depth and led to the formation of round Mo2C, hexagonal Cr 7 C 3 and needle-like Al 4 C 3 phase within the alloy as deep as 50 µm after 3000-hour corrosion testing. Based on the microstructural analysis, the corrosion mechanisms of 316 stainless steel in molten FLiBe salt in different corrosion crucibles were illuminated through schematic diagrams. Additionally, a thermal diffusion controlled corrosion model was developed and validated by experimental data for predicting the long-term corrosion attack depth.

36 MATERIALS SCIENCE↗

Mechanical characterization of 304L-VAR stainless steel in tension with a full coverage of low, intermediate, and high strain rates

A 304L-VAR stainless steel is mechanically characterized in tension over a full range of strain rates from low, intermediate, to high using a variety of apparatuses. While low- and high-strain-rate tests are conducted with a conventional Instron and a Kolsky tension bar, the tensile tests at intermediate strain rates are conducted with a fast MTS and a Drop-Hopkinson bar. The fast MTS used in this study is able to obtain reliable tensile response at the strain rates up to 150 s -1 , whereas the lower limit for the Drop-Hopkinson bar is 100 s -1 . Combining the fast MTS and the Drop-Hopkinson bar closes the gap within the intermediate strain rate regime. Using these four apparatuses, the tensile stress-strain curves of the 304L-VAR stainless steel are obtained at strain rates on each order of magnitude ranging from 0.0001 to 2580 s -1 . All tensile stress-strain curves exhibit linear elasticity followed by significant work hardening prior to necking. After necking occurrs, the specimen load decreases, and the deformation becomes highly localized until fracture. The tensile stress-strain response of the 304L-VAR stainless steel exhibits strain rate dependence. The flow stress increases with increasing strain rate and is described with a power law. The strain-rate sensitivity is also strain-dependent, possibly due to thermosoftening caused by adiabatic heating at high strain rates. The 304L-VAR stainless steel shows significant ductility. The true strains at the onset of necking and at failure are determined. The results show that the true strains at both onset of necking and failure decrease with increasing strain rate. The true failure strains are approximately 200% at low strain rates but are significantly lower (~100%) at high strain rates. The transition of true failure strain occurs within the intermediate strain rate range between 10 -2 and 10 2 s -1 . A Boltzmann description is used to present the effect of nominal strain rate on true failure strain.

304L-VAR stainless Steel↗

Ultrasonic Spectroscopy of Stainless Steel Sandwich Panels

Enhanced, lightweight material systems, such as 17-4PH stainless steel sandwich panels are being developed for use as fan blades and fan containment material systems for next generation engines. In order to improve the production for these systems, nondestructive evaluation (NDE) techniques, such as ultrasonic spectroscopy, are being utilized to evaluate the brazing quality between the 17-4PH stainless steel face plates and the 17-4PH stainless steel foam core. Based on NDE data, shear tests are performed on sections representing various levels of brazing quality from an initial batch of these sandwich structures. Metallographic characterization of brazing is done to corroborate NDE findings and the observed shear failure mechanisms.

Cosgriff, Laura M.↗

An Initial Evaluation of the Elevated-Temperature Cyclic Properties of Optimized 316H Stainless Steel Fabricated by Powder Metallurgy Hot Isostatic Pressing

Powder metallurgy hot isostatic pressing (PM-HIP) is a mature advanced manufacturing technology, which can consolidate metallic powder under high temperature and pressure to generate near-net shape components. This process can lower production costs and reduce component lead times for nuclear reactor construction and can be readily deployed in the near term for microreactor components because of their smaller size. The purpose of this work is to continue the evaluation of elevated-temperature cyclic material properties for PM-HIP 316H stainless steel. Prior scoping results have shown that the commercially procured PM-HIP stainless-steel materials have reduced creep-fatigue performance compared to wrought 316 stainless steels. To better understand how PM-HIP processed material properties compare to traditional manufacturing methods, additional billets of PM-HIP 316H stainless steel were procured and tested. This testing is necessary to understand how elevated-temperature properties are influenced by the PM-HIP process and what data are needed for incorporating PM HIP 316H into the American Society of Mechanical Engineers Boiler Pressure Vessel Code, Section III, Division 5 for high temperature reactor construction. Specifically, an additional PM-HIP 316H stainless steel billet with lower oxygen and nitrogen concentrations was fabricated by the Nuclear Advanced Manufacturing Research Centre of the United Kingdom and tested to understand if elevated-temperature cyclic properties can be improved. The creep-fatigue resistance of the material from this new billet did not show appreciable improvement compared to prior testing.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Iodine susceptibility of pseudomonads grown attached to stainless steel surfaces

Pseudomonads were adapted to grow in phosphate-buffered water and on stainless steel surfaces to study the iodine sensitivity of attached and planktonic cells. Cultures adapted to low nutrient growth were incubated at room temperature in a circulating reactor system with stainless steel coupons to allow biofilm formation on the metal surfaces. In some experiments, the reactor was partially emptied and refilled with buffer at each sampling time to simulate a "fill-and-draw" water system. Biofilms of attached bacteria, resuspended biofilm bacteria, and reactor suspension, were exposed to 1 mg l-1 iodine for 2 min. Attached bacterial populations which established on coupons within 3 to 5 days displayed a significant increase in resistance to iodine. Increased resistance was also observed for resuspended cells from the biofilm and planktonic bacteria in the system suspension. Generally, intact biofilms and resuspended biofilm cells were most resistant, followed by planktonic bacteria and phosphate buffer cultures. Thus, biofilm formation on stainless steel surfaces within water systems can result in significantly increased disinfection resistance of commonly-occurring water-borne bacteria that may enhance their ability to colonise water treatment and distribution systems.

NASA Program Environmental Health↗

The significant impact of cold deformation on structure-property relationship in phase reversion-induced stainless steels

Highlights: • Parts of metastable austenite transformed into strain-induced martensite in 18Cr-8Ni stainless steel during cold-rolled process. • The kinetics of reversion transformation from martensite to austenite was fastest in 90% cold-rolled sample during annealing treatment. • The austenite grain size for the 90% cold-rolled sample after annealing was smallest and most uniform, which induced highest yield strength and elongation combination. - Abstract: The present study aims to investigate the impact of cold deformation on structure-property relationship in phase reversion-induced stainless steels. The commercial 18Cr-8Ni stainless steel was cold rolled at room temperature to 30%, 60% and 90% thickness reduction, respectively and subsequently annealed at 900 °C for 1–100 min. Evolution of phases in selected samples was identified and quantified by X-ray diffraction together with the corresponding microstructural characterization through optical, scanning and transmission electron microscopy, and electron backscatter diffraction. Mechanical properties of selected samples were determined by the tensile test. The results indicated that parts of metastable austenite transformed into strain-induced martensite during cold rolling process, and the volume fraction of martensite increased with increase in cold rolling reduction. The kinetics of reversion transformation from martensite to austenite was fastest in 90% cold-rolled sample during annealing treatment. The austenite grain size for the 90% cold-rolled sample after annealing was smallest and most uniform, which induced highest yield strength and elongation combination.

36 MATERIALS SCIENCE↗

Effect of Nickel on the Adhesion and Corrosion Ability of Pseudomonas aeruginosa on Stainless Steel

Microbial colonization of metal surfaces or adhesion of bacteria on metal surfaces is a crucial step in initiating microbiologically influenced corrosion. As the substrate is essential in the development of a biofilm, an understanding of how substrate properties affect adhesion of bacterial cells, including the mechanism of bacterial adhesion, may assist in designing or modifying substrates to inhibit bacterial adhesion and prevent the corrosion of materials. A study was carried out to investigate the effect of nickel on the adhesion and corrosion ability of stainless steels with the same chromium content in nutrient-rich simulated seawater containing Pseudomonas aeruginosa. These stainless steels were 201, 316, 304 and 430 stainless steels. In addition, a carbon steel sample with fully nickel coated was included for comparison. The hydrophobicity of different materials was evaluated by measuring the contact angles made by the water, glycerol and formaldehyde. The number of bacteria adhering to the material surface after short-term immersion was counted by fluorescence microscopy. For corrosion study, the corrosion rates and pitting morphology were studied after 42 days of immersion. The corrosion behavior of the samples was also observed by scanning electron microscope (SEM) coupled with energy-dispersive x-ray spectroscopy (EDX) and inductively coupled plasma mass spectrometry (ICPMS). It was found that the nickel-coated sample had the highest level of bacteria attachment and offered poor corrosion resistance under artificial seawater with Pseudomonas aeruginosa strain. Higher nickel content in stainless steel resulted in a higher level of bacteria attachment. It was found that stainless steel with molybdenum exhibited better corrosion resistance in artificial seawater containing bacteria.

36 MATERIALS SCIENCE↗

Strengthening mechanisms in directed energy deposited austenitic stainless steel

Microstructures and mechanical properties are evaluated in austenitic stainless steel structures fabricated by directed energy deposition (DED) considering the effects of applied loading orientation, build geometry, and distance from the deposition baseplate. Locations within an as-deposited build with different thermomechanical history display different yield strength, while those locations with similar history have approximately the same yield strength, regardless of test specimen orientation. Thermal expansion of deposited material near the baseplate is inhibited by the mechanical constraint imposed by the baseplate, promoting plastic deformation and producing a high density of dislocations. Concurrently, high initial cooling rates decrease away from the baseplate as the build is heated, causing an increased spacing of cellular solidification features. An analysis of strengthening mechanisms quantitatively established for the first time the important strengthening contribution of high dislocation densities in the materials (166–191 MPa) to yield strength that ranged from 438 to 553 MPa in the present DED fabricated structures. A newly adopted mechanistic relationship for microsegregation strengthening from the literature indicated an additional important contribution to strengthening (123–135 MPa) due to the cellular solidification features. These findings are corroborated by the measured evolution of microstructure and hardness caused by annealing the DED material. Finally, these results suggest that the mechanical properties of deposited austenitic stainless steels can be influenced by controlling thermomechanical history during the manufacturing process to alter the character of compositional microsegregation and the amount of induced plastic deformation.

36 MATERIALS SCIENCE↗

In-Situ Synchrotron X-ray Computed Microtomography and Diffraction Investigation of Deformation and Fracture Behavior in a Laser Powder Bed Fusion Processed 316L Stainless Steel

Introduce defects into laser powder bed fusion stainless steel samples by controlling processing parameters. Perform in-situ x-ray microtomography on L-PBF stainless steel samples during plastic deformation. Relate defect characteristics and evolution to tensile behavior. Understand how processing conditions translate to initial defect characteristics. Track and evaluate defect evolution as a function of plastic deformation. Determine how deformation and fracture mechanics change as a result of AM defects.

36 MATERIALS SCIENCE↗

Particle Impact Ignition Test Data on a Stainless Steel Hand Valve

This slide presentation reviews the particle impact ignition test of a stainless steel hand valve. The impact of particles is a real fire hazard with stainless steel hand valves, however 100 mg of particulate can be tolerated. Since it is unlikely that 100 mg of stainless steel contaminant particles can be simultaneously released into this type of valve in the WSTF configuration, this is acceptable and within statistical confidence as demonstrated by testing.

Peralta, Stephen↗

Performance of stainless steel interconnects with (Mn,Co) 3 O 4 -Based coating for solid oxide electrolysis

Mixed transition-metal oxide coatings are commonly applied to stainless steel interconnects for solid oxide cell stacks. Such coatings reduce oxidation and Cr evaporation rates, leading to improved degradation rate and stack lifetime. Here, the ChromLok™ MCO-based composition (Mn,Co) 3 O 4 is applied to Crofer 22 APU stainless steel and evaluated specifically for application in solid oxide electrolyzer stacks operating around 800 °C and utilizing oxygen-ion-conducting solid oxide cells. The MCO coating is found to decrease the stainless steel oxidation rate by about one order of magnitude, and decrease the Cr evaporation rate by fourfold. Furthermore, the coating also dramatically lowers the rate of area-specific resistance increase for stainless steel coupons oxidized for 500 h with constant current applied, from 33 mΩ*cm 2 kh -1 for an uncoated coupon to less than 4 mΩ*cm2 kh -1 for coated coupons. The coating is demonstrated on full-scale interconnects for single-cells, where the coating dramatically reduces degradation rate, and for a stack, which displays stable operation for 700 h.

08 HYDROGEN↗

Interaction of beryllium with 316H stainless steel in molten Li 2 BeF 4 (FLiBe)

The increased demand in renewable energy resources has led to a renewed interest in nuclear reactors including a new generation of molten salt reactors. One of the issues encountered in handling of molten chloride or fluoride salts is the inability of metals to form and retain a protective oxide surface layer, generally chromium oxide. The low chromium content, nickel-based alloy INOR-8, later marketed as Hastelloy N, was specifically developed to contain molten fluorides. This alloy had some deficiencies, but its composition resulted in it incurring far less chromium depletion by the molten fluoride salts than alloys like 316 stainless steel. For the next generation of molten salt reactors, an alloy with pressure vessel code approval and higher temperature capability than Hastelloy N is required. Consequently, several reactor designers have reportedly chosen to build the reactor containment vessel from 316H stainless steel. In order to minimize corrosion of the stainless steel by the molten fluoride salt (2LiF-BeF 2 ), it is proposed to add beryllium metal to the salt to react with impurities and provide a means to lower the oxidation potential thus making the salt less corrosive. Even so, there is a concern whether the beryllium would react with components of the stainless steel. To address this concern, static capsule tests were conducted in which selected amounts of beryllium were added to capsules containing 2LiF-BeF 2 (FLiBe) salt and 316H stainless steel and Hastelloy N samples. Following exposure, the samples were cleaned and examined using a variety of analysis techniques including, optical microscopy, SEM-EDS, XPS, LIBS, XRD and EPMA. Tensile samples were also exposed in capsules, and those were subjected to tensile testing. Notably, It was found that for the level of beryllium additions used in this study, intermetallic compounds were formed which could be detrimental to the long-term performance of the 316H stainless steel.

36 MATERIALS SCIENCE↗

Corrosion Behavior of Plasma-Nitrided 904L Austenitic Stainless Steel in Hydrofluoric Acid

A new type of high-chromium nickel molybdenum super austenitic stainless steel, 904L, has excellent corrosion resistance in acidic environments. However, the service life of 904L decreases significantly in a mixed acid system that includes hydrogen fluoride and sulfuric acid. In this article, different plasma nitriding processes were used to modify the surface of 904L stainless steel. X-ray diffraction was used to analyze the phase composition after nitriding; scanning electron microscopy and atomic force microscopy were used to examine the surface morphology after nitriding; electrochemical noise and electrochemical methods were used to study the localized corrosion behavior and the damage mechanism of the ion nitride layer; and the effect of the plasma nitride layer on the corrosion resistance was explored. The results show that with increasing nitriding time, the thickness of the nitride layer increased. Ion nitriding resulted in the coarsening of the 904L austenitic stainless steel surface. A long nitriding treatment time resulted in the precipitation of CrN in the modified layer, depleting the chromium from the matrix and remarkably reducing the corrosion resistance.

36 MATERIALS SCIENCE↗