At least 127 records · Page 7

Total temperature probes for high-temperature hypersonic boundary-layer measurements

The design and test results of two types of total temperature probes that were used for hypersonic boundary-layer measurements are presented. The intent of each design was to minimize the total error and to maintain minimal size for measurements in boundary layers 1.0 in. thick and less. A single platinum-20-percent-rhodium shield was used in both designs to minimize radiation heat transfer losses during exposure to the high-temperature test stream. The shield of the smaller design was flattened at the flow entrance to an interior height of 0.02 in., compared with 0.03 in. for the larger design. The resulting vent-to-inlet area ratios were 60 and 50 percent. A stainless steel structural support sleeve that was used in the larger design was excluded from the smaller design, which resulted in an outer diameter of 0.059 in., to allow closer placement of the probes to each other and to the wall. These small design changes to improve resolution did not affect probe performance. Tests were conducted at boundary-layer-edge Mach numbers of 5.0 and 6.2. The nominal free-stream total temperatures were 2600 degrees and 3200 degrees R. The probes demonstrated extremely good reliability. The best performance in terms of recovery factor occurred when the wire-based Nusselt number was at least 0.04. Recommendations for future probe designs are included.

Albertson, Cindy W.↗

Broadband Shock Noise in Internally-Mixed Dual-Stream Jets

Broadband shock noise (BBSN) has been studied in some detail in single-flow jets and recently in dual-stream jets with separate flow exhaust systems. Shock noise is of great concern in these latter cases because of the noise created for the aircraft cabin by the underexpanded nozzle flow at cruise. Another case where shock noise is of concern is in the case of future supersonic aircraft that are expected to have bypass ratios small enough to justify internally mixed exhaust systems, and whose mission will push cycles to the point of imperfectly expanded flows. Dual-stream jets with internally mixed plume have some simplifying aspects relative to the separate flow jets, having a single shock structure given by the common nozzle pressure. This is used to separate the contribution of the turbulent shear layer to the broadband shock noise. Shock structure is held constant while the geometry and strength of the inner and merged shear layers are varying by changing splitter area ratio and core stream temperature. Flow and noise measurements are presented which document the efforts at separating the contribution of the inner shear layer to the broadband shock noise.

Bridges, James E.↗

Experimental Investigation of Coaxial Jet Mixing of Two Subsonic Streams at Various Temperature, Mach Number, and Diameter Ratios for Three Configurations

An experimental investigation of the mixing of two coaxial gas streams was conducted over a range of subsonic jet Mach numbers and temperatures. Three configurations were investigated. One had no innerbody in the primary or inner pipe and was designed to give flat velocity profiles at the exit of the primary pipe. The other two configurations had innerbodies in the primary pipe. These were designed to give velocity profiles similar to those existing at the inlet of propulsive systems such as afterburners. Curves of axial velocity and temperature profiles across the radius are presented at various axial stations. For the two configurations with the innerbody, data are shown at stations out to approximately 8 primary-pipe diameters from the exit of the primary pipe. For the flat-velocity-profile configuration, data are shown at distances extending downstream at 22 primary-pipe diameters from the exit of the primary pipe.

Burley, Richard R.↗

Theoretical jet exhaust noise model for the duct burning turbofan

A model was developed to predict the acoustic power spectrum for a Duct Burning Turbofan (DBTF) whose cycle results in a high velocity, high temperature fan stream and a lower velocity, lower temperature primary stream. Model tests have demonstrated that a DBTF may produce substantially less noise than a conventional turbojet with the same thrust and weight flow. Predictions from the model agreed well with measured data from the model tests. The characteristics of the DBTF acoustic power spectrum were shown to be related to the rapid mixing of the fan and primary streams. The effects of fan to primary velocity ratio, temperature ratio, area ratio, and the effect of nozzle geometry on DBTF jet noise were determined.

Larson, R. S.↗

Velocity and temperature characteristics of two-stream, coplanar jet exhaust plumes

The subsonic jet exhaust velocity and temperature characteristics of model scale, two stream coplanar nozzles were obtained experimentally. The data obtained included the effects of fan to primary stream velocity and temperature ratios on the jet axial and radial flow characteristics. Empirical parameters were developed to correlate the measured data. The resultant equations were shown to be extensions of a previously published single stream jet velocity and temperature correlation.

Vonglahn, U. H.↗

Velocity and temperature characteristics of two-stream, coplanar jet exhaust plumes

The subsonic jet exhaust velocity and temperature characteristics of model scale, two stream coplanar nozzles were obtained experimentally. The data obtained included the effects of fan to primary stream velocity and temperature ratios on the jet axial and radial flow characteristics. Empirical parameters were developed to correlate the measured data. The resultant equations were shown to be extensions of a previously published single stream jet velocity and temperature correlation.

Von Glahn, U.↗

Thermodynamic Modeling of a Solid Oxide Fuel Cell to Couple with an Existing Gas Turbine Engine Model

The Controls and Dynamics Technology Branch at NASA Glenn Research Center are interested in combining a solid oxide fuel cell (SOFC) to operate in conjunction with a gas turbine engine. A detailed engine model currently exists in the Matlab/Simulink environment. The idea is to incorporate a SOFC model within the turbine engine simulation and observe the hybrid system's performance. The fuel cell will be heated to its appropriate operating condition by the engine s combustor. Once the fuel cell is operating at its steady-state temperature, the gas burner will back down slowly until the engine is fully operating on the hot gases exhausted from the SOFC. The SOFC code is based on a steady-state model developed by The U.S. Department of Energy (DOE). In its current form, the DOE SOFC model exists in Microsoft Excel and uses Visual Basics to create an I-V (current-voltage) profile. For the project's application, the main issue with this model is that the gas path flow and fuel flow temperatures are used as input parameters instead of outputs. The objective is to create a SOFC model based on the DOE model that inputs the fuel cells flow rates and outputs temperature of the flow streams; therefore, creating a temperature profile as a function of fuel flow rate. This will be done by applying the First Law of Thermodynamics for a flow system to the fuel cell. Validation of this model will be done in two procedures. First, for a given flow rate the exit stream temperature will be calculated and compared to DOE SOFC temperature as a point comparison. Next, an I-V curve and temperature curve will be generated where the I-V curve will be compared with the DOE SOFC I-V curve. Matching I-V curves will suggest validation of the temperature curve because voltage is a function of temperature. Once the temperature profile is created and validated, the model will then be placed into the turbine engine simulation for system analysis.

Brinson, Thomas E.↗

Data from: “Significant stream chemistry response to temperature variations in a high-elevation mountain watershed”

High-elevation mountain regions, central to global freshwater supply, are experiencing more rapid warming than low-elevation locations. High-elevation streams are therefore potentially critical indicators for earth system and water chemistry response to warming. Here we present concerted hydroclimatic and biogeochemical data from Coal Creek, Colorado in the central Rocky Mountains at elevations of 2700 to 3700 m, where air temperatures have increased by about 2 °C since 1980. We analyzed water chemistry every other day from 2016 to 2019. Water chemistry data indicate distinct responses of different solutes to inter-annual hydroclimatic variations. Specifically, the concentrations of solutes from rock weathering are stable inter-annually. Solutes that are active in soils, including dissolved organic carbon, vary dramatically, with double to triple peak concentrations occurring during snowmelt and in warm years. We advocate for consistent and persistent monitoring of high elevation streams to record early glimpse of earth surface response to warming.1) Coal Creek stream were sampled and measured to answer the question if there is a significant stream chemistry response to climate change in high-elevation watershed2) The file contains data regarding discharge, water temperature and stream chemistry data for 2016-2019 year. Stream chemistry includes dissolved organic and inorganic carbon, chloride, nutrients, cations. The data collection efforts were carried out by the DOE-funded "Advancing a Watershed Hydro-Biogeochemical Theory: Linking Water Travel Time and Reaction Rates Under Changing Climate" project and Watershed Function SFA.

54 ENVIRONMENTAL SCIENCES↗

Heat Transfer Experiments of Ribbed, Serpentine Cooling Passages with Supercritical CO2

The results of heat transfer experiments with supercritical CO2 (sCO2) to capture the performance of ribbed, serpentine cooling passages for Reynolds numbers in the range of 100,000 - 400,000 are presented. The oxy-combustion turbine operating in an Allam-Fetvedt cycle has a turbine inlet temperature exceeding 1100°C, necessitating internally cooled turbine blades due to material creep strength limits. Reynolds numbers for sCO2, with its combination of high fluid density and low viscosity, can be up to an order of magnitude higher than comparable internal cooling conditions for an air-breathing engine where the majority of experimental data exists. To improve the prediction of cooling performance through turbulated passages, a test rig was designed and constructed with interchangeable insert capability for operation in sCO2 with heat transfer from a heater outlet flow stream to a lower temperature recuperator outlet flow stream. The inserts included serpentine passage geometry with five passes, one of the inserts including chevron ribs and the other a plain wall. The multi-pass serpentine geometry allowed for the evaluation of the effects 180 deg. tip turns have on the return passage flow characteristics, as they can depart significantly from fully-developed flow characteristics. The test procedure included the use of a modified Wilson plot method, with hot flow stream conditions kept effectively constant so that monitored changes in the overall thermal resistance could be attributed to manipulations in cooling flow stream conditions. Conditions during testing consisted of test section pressures of approximately 180 bar, cooling flow stream temperature of 175°C and hot flow stream temperature of 410°C. Test points at discrete cool flow Reynolds numbers up to 400,000 demonstrated an expected trend of decreased fluid thermal resistance with increasing Reynolds number, while at comparable Reynolds number there was an exhibited lower thermal resistance and higher passage pressure drop for the ribbed insert compared to the plain-walled insert. Processing of test data included establishment of Nusselt number enhancement ratios, so that for different internal cooling passage dimensions in the actual turbine blade at comparable Reynolds number the ratio could be applied to predict cooling performance.

Marshall, Michael↗

Significant stream chemistry response to temperature variations in a high-elevation mountain watershed

Abstract High-elevation mountain regions, central to global freshwater supply, are experiencing more rapid warming than low-elevation locations. High-elevation streams are therefore potentially critical indicators for earth system and water chemistry response to warming. Here we present concerted hydroclimatic and biogeochemical data from Coal Creek, Colorado in the central Rocky Mountains at elevations of 2700 to 3700 m, where air temperatures have increased by about 2 °C since 1980. We analyzed water chemistry every other day from 2016 to 2019. Water chemistry data indicate distinct responses of different solutes to inter-annual hydroclimatic variations. Specifically, the concentrations of solutes from rock weathering are stable inter-annually. Solutes that are active in soils, including dissolved organic carbon, vary dramatically, with double to triple peak concentrations occurring during snowmelt and in warm years. We advocate for consistent and persistent monitoring of high elevation streams to record early glimpse of earth surface response to warming.

54 ENVIRONMENTAL SCIENCES↗

Impingement of water droplets on wedges and double-wedge airfoils at supersonic speeds

An analytical solution has been obtained for the equations of motion of water droplets impinging on a wedge in a two-dimensional supersonic flow field with a shock wave attached to the wedge. The closed-form solution yields analytical expressions for the equation of the droplet trajectory, the local rate of impingement and the impingement velocity at any point on the wedge surface, and the total rate of impingement. The analytical expressions are utilized to determine the impingement on the forward surfaces of diamond airfoils in supersonic flow fields with attached shock waves. The results presented include the following conditions: droplet diameters from 2 to 100 microns, pressure altitudes from sea level to 30,000 feet, free-stream static temperatures from 420 degrees r, free stream Mach numbers from 1.1 to 2.0, semiapex angles for the wedge from 1.14 degrees to 7.97 degrees, thickness-to-chord ratios for the diamond airfoil from 0.02 to 0.14, chord lengths from 1 to 20 feet, and angles of attack from zero to the inverse tangent of the airfoil thickness-to-chord ratio.

Serafini, John S↗

Use Attainability Analysis Aquatic Life Uses for Perennial Reach of Sandia Canyon [Slides]

The following information will be presented during the February 23, 2022 Accord Pueblos Technical Meeting. The purpose of the study is to determine if natural thermal conditions are preventing the attainment of Coldwater Aquatic Life Use in the perennial reach of the upper Sandia Canyon Assessment Unit (Sandia AU). The New Mexico Water Quality Standards allow for a change in the designated use if a Use Attainability Analysis (UAA) demonstrates that the use is not attainable due to one or more of six factors listed in 40 CFR 131.10(g), including naturally occurring pollutant concentrations. The Sandia AU is located in a perennial reach of upper Sandia Canyon between Sigma Canyon and NPDES Outfall 001. The classified Segment 20.6.4.126 NMAC comprises perennial waters within Los Alamos National Laboratory boundaries and includes the Sandia AU. Persistent surface flows originate from NPDES permitted effluent releases. These releases have occurred since the early 1950’s and continue today. The UAA examines several lines of evidence. NMED’s Air-Water Temperature Correlation (AWTC) model is used for identifying appropriate stream classifications and attainable aquatic life use subcategories. The model correlates between July average air temperatures (ATEMP) and maximum weekly average stream temperatures. Air temperatures are obtained from PRISM and LANL Meteorological Towers and used to derive ATEMP. Thermographs were placed in the Sandia AU to obtain measured stream temperatures during summer months when stream temperatures are the highest. Measured data is used with AWTC modeled data to determine if the Sandia AU is meeting its natural air temperature driven thermal condition.

54 ENVIRONMENTAL SCIENCES↗

Analytical and experimental study of supersonic combustion of hydrogen in a vitiated airstream

Detailed probe measurements of total temperature, pressure, and composition were taken in a two-dimensional test section 35.6 cm downstream of hydrogen injection. A high pressure gas generator supplied Mach 2.44 vitiated air or inert gas at elevated temperatures and at a static pressure equal to that of the hydrogen. Special water-cooled probes and sampling techniques were developed for the short test times required by heat-sink hardware. Independent methods of measuring stream total temperatures are compared. For the pure mixing case, the computed composition profile agreed well with the experimental profile. The analysis takes into account the wall boundary layer and the initial boundary layer in the main stream. Ignition of hydrogen, as determined from photographic exposures of the radiating gases, varied from 30 to 10 cm downstream from injection for a 45 K increase in local free-stream static temperature.

Burrows, M. C.↗

Lightweight moving radiators for heat rejection in space

Low temperature droplet stream radiators, using nonmetallic fluids, can be used to radiate large amounts of waste heat from large space facilities. Moving belt radiators are suitable for use on a smaller scale, radiating as few as 10 kW from shuttle related operations. If appropriate seal technology can be developed, moving belt radiators may prove to be important for high temperature systems as well. Droplet stream radiators suitable for operation at peak temperatures near 300 K and 1000 K were studied using both freezing and nonfreezing droplets. Moving belt radiators were also investigated for operation in both temperature ranges. The potential mass and performance characteristics of both concepts were estimated on the basis of parametric variations of analytical point designs. These analyses included all consideration of the equipment required to operate the moving radiator system and take into account the mass of fluid lost by evaporation during mission lifetimes. Preliminary results indicate that low temperature droplet stream radiator appears to offer the greatest potential for improvement over conventional flat plate radiators.

Knapp, K.↗

Experiments and modeling of dilution jet flow fields

Experimental and analytical results of the mixing of single, double, and opposed rows of jets with an isothermal or variable-temperature main stream in a straight duct are presented. This study was performed to investigate flow and geometric variations typical of the complex, three-dimensional flow field in the dilution zone of gas-turbine-engine combustion chambers. The principal results, shown experimentally and analytically, were the following: (1) variations in orifice size and spacing can have a significant effect on the temperature profiles; (2) similar distributions can be obtained, independent of orifice diameter, if momentum-flux ratio and orifice spacing are coupled; (3) a first-order approximation of the mixing of jets with a variable-temperature main stream can be obtained by superimposing the main-stream and jets-in-an-isothermal-crossflow profiles; (4) the penetration of jets issuing mixing is slower and is asymmetric with respect to the jet centerplanes, which shift laterally with increasing downstream distance; (5) double rows of jets give temperature distributions similar to those from a single row of equally spaced, equal-area circular holes; (6) for opposed rows of jets, with the orifice centerlines in line, the optimum ratio of orifice spacing to duct height is one-half the optimum value for single-side injection at the same momentum-flux ratiol and (7) for opposed rows of jets, with the orifice centerlines staggered, the optimum ratio of orifice spacing to duct height is twice the optimum value for single-side injection at the same momentum-flux ratio.

Holdeman, James D.↗

Compressible Laminar Boundary Layer over a Yawed Infinite Cylinder with Heat Transfer and Arbitrary Prandtl Number

The equations are presented for the development of the compressible laminar boundary layer over a yawed infinite cylinder. For compressible flow with a pressure gradient the chordwise and spanwise flows are not independent. Using the Stewartson transformation and a linear viscosity-temperature relation yields a set of three simultaneous ordinary differential equations in a form yielding similar solutions. These equations are solved for stagnation-line flow for surface temperatures from zero to twice the free-stream stagnation temperature and for a wide range of yaw angle and free-stream Mach number. The results indicate that the effect of yaw on the heat-transfer coefficient at the stagnation line depends markedly on the free-stream Mach number. An unusual result of the solutions is that for large yaw angles and stream Mach numbers the chordwise velocity within the boundary layer exceeds the local external chordwise velocity, even for a highly cooled wall.

Reshotko, Eli↗