Testing Os Staining Approach for Visualizing Soil Organic Matter Patterns in Intact Samples via X-ray Dual-Energy Tomography Scanning
Abstract not provided
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided
The squeezed cross-bispectrum B κ,Ly α between the gravitational lensing in the cosmic microwave background and the 1D Ly α forest power spectrum can constrain bias parameters and break degeneracies between σ8 and other cosmological parameters. We detect B κ,Ly α with 4.8σ significance at an effective redshift z eff =2.4 using Planck PR3 lensing map and over 280,000 quasar spectra from the Dark Energy Spectroscopic Instrument’s first-year data. We test our measurement against metal contamination and foregrounds such as Galactic extinction and clusters of galaxies by deprojecting the thermal Sunyaev-Zeldovich effect. Finally, we compare our results to a tree-level perturbation theory calculation and find reasonable agreement between the model and measurement.
Not Available
In this study, we investigated the thermal transport properties of two α–RuCl 3 crystals with different degrees of stacking disorder to understand the origin of the previously reported oscillatory feature in the field dependence of thermal conductivity. Crystal I shows only one magnetic order around 13 K, which is near the highest T N for α–RuCl 3 with stacking faults. Crystal II has less stacking disorder, with a dominant heat capacity at 7.6 K along with weak anomalies at 10 and 13 K. In the temperature and field dependence of thermal conductivity, no obvious anomaly was observed to be associated with the magnetic order around 13 K for either crystal or around 10 K for crystal II. Crystal II showed clear oscillations in the field dependence of thermal conductivity, while crystal I did not. For crystal I, an L-shaped region in the temperature-field space was observed where thermal Hall conductivity κ xy /T is within ±20% of the half quantized thermal Hall conductivity κ HQ /T, while for crystal II, κ xy /T reaches κ HQ /T only in the high field and high temperature regime with no indication of a plateau at κ HQ /T. Our thermal conductivity data suggest the oscillatory features are inherent to the zigzag ordered phase with T N near 7 K. Our planar thermal Hall effect measurements suggest the sensitivity of this phenomena to stacking disorder. Overall, our results highlight the importance of understanding and controlling crystallographic disorder for obtaining and interpreting intrinsic thermal transport properties in α–RuCl 3 .
Explore the source record for details and available documents.
Documentation required by New Mexico Environmental Department to certify completion of Supplemental Environmental Project subprojects.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Abstract not provided.
Abstract not provided.
Explore the source record for details and available documents.
The goal of the salt sampling program at Argonne is to develop and deploy automated molten salt sampling approaches for interfacing relevant unit operations with salt analysis to improve the timeliness of sampling-based accountancy measurements. Two technologies under development in support of this goal are a vacuum sampling loop module and a high-throughput pneumatic sample generator module. Compared to traditional point sampling approaches (i.e., dip probes), the vacuum sampling loop facilitates the collection of a larger cross-section of the bulk salt in order to collect more representative samples. The vacuum sampling approach also eliminates the risk of dross contamination of samples and avoids the use of moving parts in the salt. The pneumatic sample generator module is used to facilitate high-throughput sample analysis to improve the measurement precision of any given analytical technique by averaging out random sampling and measurement errors. In FY21, two methods for integrating these two modules were tested including direct fluidic coupling and coupling using a solid salt transfer mechanism. Solid salt transfer was ultimately selected over fluidic coupling, primarily to enable the transport of samples over longer distances to support automated at-line integration with high-precision techniques (such as microcalorimetry) that cannot withstand the conditions near an electrorefining process. To facilitate rapid solid salt coupling, new mechanisms were developed for rapidly charging and discharging salt sample tubes at the vacuum sampling loop and pneumatic sample generator modules, respectively. While the charging mechanism will be deployed in FY22, the discharge mechanism was tested in FY21 and is described here. The solid salt tube transfer method was deployed at one of Argonne’s engineering-scale electrorefiners to implement at-line high-throughput pneumatic micro-sample generation capabilities. The approach was used to generate precise uranium- and lanthanide-bearing electrorefiner micro-samples with the specific dimensions requested by researchers at Los Alamos National Laboratory for use in testing their novel microcalorimeter x-ray techniques. The solid salt transfer mechanism proved not only to be an effective means of integrating the precision sample generator with vacuum sampling, but also improved the performance of the sampler generator. To discharge salt from the sample tubes at the sampler generator, tube segments were inserted directly into the sample generator’s Helmholtz chamber and pressure pulse actuations were used to generate precision molten salt samples directly from the tube segments. The direct insertion of sample tubes into the sample generator enabled rapid loading of the salt and prevented salt from contacting most of the interior surfaces of the sample generator, which eliminated cross-contamination between runs. The vacuum sampling-loop tube charging mechanism will support high-throughput tube sampling operations by employing a dynamic vacuum filling process to fill short charge tubes that are configured to be rapidly connected and disconnected from the loop. The dynamic vacuum sampling operation will be automated, and sample tube handling can be executed with simple overhead actuation. Because the modular sampling approach described here eliminates the need for new high-radiation sample handling capabilities, salt-wetted seals, salt-wetted moving parts, and heated transfer lines outside the electrorefiner, it will address most of the remaining technical challenges for the at-line deployment of high-precision analytical techniques which will enable significant reductions in the time delay for sampling-based high-precision accountancy measurements.
SRNL analyzed samples from Tank 38H and Tank 43H to support ECP and CCP. The results indicate the concentrations of most soluble species in the Tank 38H surface sample increased slightly from the previous surface sample. The Tank 38H sub-surface sample shows changes in concentration for soluble species in the solution with some increasing and some decreasing. The current Tank 38H sub-surface sample contains more sludge solids than the previous sample based on visual appearance. The small differences in the concentrations of major components between the Tank 38H surface and sub-surface samples indicate only minimal stratification of solution species within the tank. The Tank 43H surface and sub-surface samples are similar in composition to the previous samples. The similar solution compositions measured in the Tank 43H surface and sub-surface samples indicate a minimal stratification within the tank. The total uranium and plutonium in the current Tank 38H surface sample remains similar to the previous analysis. The Tank 38H sub-surface sample shows an increase in uranium and plutonium concentrations compared to the previous sample likely because of an increase in sludge solids in the current sample. The total uranium concentration in the two Tank 43H samples is essentially unchanged from previous sample results. The plutonium concentration in the Tank 43H surface sample is similar to the previous sample results while the plutonium in the Tank 43H sub-surface sample increased relative to the previous analysis. The sum of the major cations versus the sum of the major anions shows a difference of <10% for both samples from Tank 38H and for both samples from Tank 43H providing an indication of good data quality for the non-radioactive analytes in the samples. The silicon concentrations measured in the Tank 38H sub-surface sample increased compared with the previous sample results likely due to the presence of more sludge solids in the current sample. The Tank 38H surface sample silicon concentrations is similar to the previous sample results. The Tank 43H surface and sub-surface sample silicon concentrations both increased compared to the previous sample results. The samples analyzed from Tanks 38H and 43H show silicon concentrations ranging from 61.5 to 97.3 mg/L.
The goal of the salt sampling program at Argonne is to develop and deploy automated molten salt sampling approaches to enable high-precision in-process salt sample analysis to improve the timeliness of sampling-based accountancy measurements. Tools currently under development in support of this goal include (1) a modular vacuum sampler with an accompanying sample handling method for coupling vacuum sampling with high-precision at-line sample analysis, (2) a pneumatic sample generator that enables high-throughput sample analysis to improve the precision of existing analytical techniques, and (3) a windowless flow cell to enable on-line optical analysis of molten salt in a sampling loop. Compared to point sampling approaches (i.e., dip probes), vacuum sampling systems and on-line sampling loops facilitate access to a larger cross-section of a process fluid. This is known to improve the characterization of the process fluid by producing more representative samples and by enabling the analysis of a larger cross section of the fluid. A vacuum sampling approach for molten salts eliminates the risk of dross contamination of samples and avoids the use of moving parts in the salt. In FY21, two methods for integrating a vacuum sampler with a pneumatic sample generator were tested. These included direct fluidic coupling and coupling using a solid salt transfer mechanism. Solid salt transfer was ultimately selected over fluidic coupling, primarily to enable the transport of samples over longer distances to support automated at-line integration with high-precision techniques (such as microcalorimetry) that cannot withstand the extreme conditions near an electrorefining process. To facilitate rapid solid salt coupling, new mechanisms were developed for rapidly charging and discharging salt sample tubes at the vacuum sampler and pneumatic sample generator, respectively. While the charging mechanism will be deployed in FY22, the tube transfer method and discharge mechanism were tested in FY21. These were deployed at one of Argonne’s engineering-scale electrorefiners to implement at-line high-throughput pneumatic micro-sample generation capabilities. The method was used to generate precise uranium- and lanthanide-bearing electrorefiner micro-samples with the specific dimensions requested by researchers at Los Alamos National Laboratory for use in testing their novel microcalorimeter x-ray techniques. The solid salt transfer mechanism proved not only to be an effective means of integrating the precision sample generator with vacuum sampling, but also improved the performance of the sampler generator. Because the modular sampling approach described here eliminates the need for new high-radiation sample handling capabilities, salt-wetted seals, salt-wetted moving parts, and heated transfer lines outside the electrorefiner, it will address most of the remaining technical challenges for the at-line deployment of high-precision analytical techniques. This will enable significant reductions in the time delay for sampling-based accountancy measurements by eliminating the need for manual off-line sample processing and analysis. On-line optical analysis of molten salt in a sampling loop would provide complementary information to at-line and in-situ techniques. In FY21, an open-aperture molten salt gravity flow cell with windowless optical access to flowing salt was successfully demonstrated. Future work should include the refinement and performance testing of the on-line and at-line sampling tools, integration of additional analysis techniques, stakeholder outreach and collaboration, evaluation of the integrated methods, and analyses to determine how the various tools might fit into an integrated safeguards monitoring system of unattended near real time monitoring tools.