Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sampling calorimeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Effect of carbonyl iron particles composition on the physical characteristics of MR grease

Magnetorheological (MR) grease is an extension of the study of magnetorheological materials. The MR grease can help to reduce the particles sedimentation problem occurred in the MR fluids. Within this study, an effort has been taken to investigate the effect of different weight compositions of carbonyl iron particles on the physical and chemical characteristics of the MR grease under off-state condition (no magnetic field). The MR grease is prepared by mixing carbonyl iron particles having a size range of 1 to 10 µm with commercial NPC Highrex HD-3 grease. Characterizations of MR grease are investigated using Vibrating Sample Magnetometer (VSM), Environmental Scanning Electron Microscopy (ESEM), Differential Scanning Calorimeter (DSC) and rheometer. The dependency of carbonyl iron particles weight towards the magnetic properties of MR grease and other characterizations are investigated.

36 MATERIALS SCIENCE↗

Development of High-Granularity Dual-Readout Calorimetry with psec Timing

Dual-readout and particle flow algorithm (PFA) are technologies proposed for precise jet energy measurement in future colliders. While PFA requires highly granular calorimeters, dual-readout has mainly been used with fiber-based calorimeters that do not have highly segmented capabilities. It is still non-trivial to combine these two technologies in one calorimeter system because of the use of fibers in most of the dualreadout calorimeters, which is not compatible with the high granularity requirement of PFA technologies. The aim of this study is to develop a novel calorimetry that combines dual-readout and PFA by adopting a highly segmented tile-based configuration. This paper compares the improvement of energy resolution using dual-readout approach across several configurations of highly granular hadron calorimeters through simulation. Results indicate that setups with fine sampling and close placement of scintillators and Cherenkov detectors improve dual-readout performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Heat capacity of microgram oxide samples by fast scanning calorimetry

Quantitative scanning calorimetry on microgram-sized samples opens a broad, new range of opportunities for studying the thermodynamic properties of quantity-limited materials, including those produced under extreme conditions or found as rare accessory minerals in nature. We calibrated the Mettler Toledo Flash DSC 2+ calorimeter to obtain quantitative heat capacities in the range 200–350 °C, using samples weighing between 2 and 11.5 μg. Our technique is applied to a new set of oxide materials to which it has never been used before, without the need for melting, glass transitions, or phase transformations. Heat capacity data were obtained for silica in the high pressure stishovite (rutile) structure, dense post-stishovite glass, standard fused quartz, and for TiO2 rutile. These heat capacities agree within 5%–15% with the literature values reported for rutile, stishovite, and fused SiO2 glass. The heat capacity of post-stishovite glass, made by heating stishovite to 1000 °C, is a newly reported value. After accurate calibrations, measured heat capacities were then used to calculate masses for samples in the microgram range, a substantial improvement over measurement in conventional microbalances, which have uncertainties approaching 50%–100% for such small samples. Since the typical uncertainty of heat capacities measured on 10–100 mg samples in conventional differential scanning calorimetry is typically 7% (1%–5% with careful work), flash differential scanning calorimetry, using samples a factor of 1000 smaller, increases the uncertainty of heat capacity measurements by a factor of <3, opening the door for meaningful measurements on ultra-small, high-pressure samples and other quantity-limited materials.

Instruments & Instrumentation↗

Measurements of the $W$ Boson Mass with the D0 Detector

In the first part, we describe what is the W boson mass in the context of the Standard Model. We discuss the prominent role this physical observable plays in the determination of the internal self consistency of the Electroweak Sector. We review measurements and calculation of the W boson mass done in past and argue about the importance and feasibility of improving the experimental determination. We give a description of the Fermilab Tevatron Collider and the D0 detector, highlighting the relevant parts for the measurement described in this Dissertation. In the second part, we give a detailed description of a measurement of the W boson mass using the D0 Central Calorimeter. The measurement uses 1.68 x 10 6 candidates from W → en decays, corresponding to 4.3 fb -1 of integrated luminosity collected from 2006 to 2009. We measure the mass using the transverse mass, electron transverse momentum, and missing transverse energy distributions. The transverse mass and electron transverse momentum measurements are the most precise and are combined to give MW = 80.367 ± 0.013(stat) ± 0.023 (syst) GeV = 80.367 ± 0.026 GeV. This is combined with an earlier D0 result determined using an independent 1 fb -1 data sample, also with central electrons only, to give M W = 80.375± 0.023 GeV. The uncertainty in the measurement is dominated by the determination of the calorimeter electron energy scale, the W sample size, the knowledge of the parton distribution function. In the third part, we discuss methods of reducing the dominant uncertainties in the W boson mass measurements. We show that introducing electrons detected in the End Calorimeters greatly reduce the measurement systematic uncertainty, especially the on related to the parton distribution functions. We describe a precise calibration of the End Calorimeter using Z → ee events corresponding to 4.3 fb -1 of integrated luminosity. The calibration is an important milestone in a measurement that explores a larger part of the D0 Calorimeter. We present parametrized models that describe the response of the End Calorimeters to electron showers and soft hadronic particles, giving special attention to the specific challenges of a measurement in the forward region: the inhomogeneity of the uninstrumented materials, the large hadronic energy flow in the calorimeter and the jet misidentification probability.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for long-lived particles using out-of-time trackless jets in proton-proton collisions at $\sqrt{s}$ = 13 TeV

A search for long-lived particles decaying in the outer regions of the CMS silicon tracker or in the calorimeters is presented. The search is based on a data sample of proton-proton collisions at $\sqrt{s}$ = 13 TeV recorded with the CMS detector at the LHC in 2016–2018, corresponding to an integrated luminosity of 138 fb −1 . A novel technique, using nearly trackless and out-of-time jet information combined in a deep neural network discriminator, is employed to identify decays of long-lived particles. The results are interpreted in a simplified model of chargino-neutralino production, where the neutralino is the next-to-lightest supersymmetric particle, is long-lived, and decays to a gravitino and either a Higgs or Z boson. This search is most sensitive to neutralino proper decay lengths of approximately 0.5 m, for which masses up to 1.18 TeV are excluded at 95% confidence level. The current search is the best result to date in the mass range from the kinematic limit imposed by the Higgs boson mass up to 1.8 TeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Microstructure and thermomechanical properties relationship of segmented thermoplastic polyurethane (TPU)

Thermoplastic polyurethanes (TPU) are important polymeric materials for seals. In competition with Acrylonitrile butadiene rubbers (NBR), TPU exhibits higher strength and a considerable better abrasion resistance. The advantage of NBR over TPU is a smaller compression set but however TPU excels in its much shorter processing cycle times. Generally a TPU is a block copolymer composed of hard and soft segments, which plays an important role in determining the material properties. TPU can be processed either to ready moulded parts or can be incorporated by multi component moulding, in both cases it shows decent mechanical properties. In the present work, the relationship between melt-process induced TPU morphology and resultant thermo mechanical properties were examined and determined by means of quasi-static tensile test, creep experiment, tension test and dynamical mechanical analysis (DMA). Scanning electron beam microscope (SEM) and differential scanning calorimeter (DSC) were used to study the morphology of the samples. A significant mathematical description of the stress-strain behaviour of TPU was found using a 3 term approach. Moreover it became evident that processing conditions such as processing temperature have crucial influence on morphology as well as short and long-term performance. To be more precise, samples processed at higher temperatures showed a lack of large hard segment agglomerates, a smaller strength for strains up to 250% and higher creep compliance.

36 MATERIALS SCIENCE↗

Gasoline Combustion Fundamentals DOE FY17 Report

Advanced automotive gasoline engines that leverage a combination of reduced heat transfer, throttling, and mechanical losses; shorter combustion durations; and higher compression and mixture specific heat ratios are needed to meet aggressive DOE VTP fuel economy and pollutant emission targets. Central challenges include poor combustion stability at low-power conditions when large amounts of charge dilution are introduced and high sensitivity of conventional inductive coil ignition systems to elevated charge motion and density for boosted high-load operation. For conventional spark ignited operation, novel low-temperature plasma (LTP) or pre-chamber based ignition systems can improve dilution tolerances while maintaining good performance characteristics at elevated charge densities. Moreover, these igniters can improve the control of advanced compression ignition (ACI) strategies for gasoline at low to moderate loads. The overarching research objective of the Gasoline Combustion Fundamentals project is to investigate phenomenological aspects related to enhanced ignition. The objective is accomplished through targeted experiments performed in a single-cylinder optically accessible research engine or an in-house developed optically accessible spark calorimeter (OASC). In situ optical diagnostics and ex situ gas sampling measurements are performed to elucidate important details of ignition and combustion processes. Measurements are further used to develop and validate complementary high-fidelity ignition simulations. The primary project audience is automotive manufacturers, Tier 1 suppliers, and technology startups—close cooperation has resulted in the development and execution of project objectives that address crucial mid- to long-range research challenges.

33 ADVANCED PROPULSION SYSTEMS↗

Cosmic ray sampling of a clumpy interstellar medium

How cosmic rays sample the multi-phase interstellar medium (ISM) in starburst galaxies has important implications for many science goals, including evaluating the cosmic ray calorimeter model for these systems, predicting their neutrino fluxes, and modeling their winds. Here, we use Monte Carlo simulations to study cosmic ray sampling of a simple, two-phase ISM under conditions similar to those of the prototypical starburst galaxy M82. The assumption that cosmic rays sample the mean density of the ISM in the starburst region is assessed over a multi-dimensional parameter space where we vary the number of molecular clouds, the galactic wind speed, the extent to which the magnetic field is tangled, and the cosmic ray injection mechanism. We evaluate the ratio of the emissivity from pion production in molecular clouds to the emissivity that would be observed if the cosmic rays sampled the mean density, and seek areas of parameter space where this ratio differs significantly from unity. The assumption that cosmic rays sample the mean density holds over much of parameter space; however, this assumption begins to break down for high cloud density, injection close to the clouds, and a very tangled magnetic field. We conclude by evaluating the extent to which our simulated starburst region behaves as a proton calorimeter and constructing the time-dependent spectrum of a burst of cosmic rays.

79 ASTRONOMY AND ASTROPHYSICS↗

CaloScore v2: single-shot calorimeter shower simulation with diffusion models

Diffusion generative models are promising alternatives for fast surrogate models, producing high-fidelity physics simulations. However, the generation time often requires an expensive denoising process with hundreds of function evaluations, restricting the current applicability of these models in a realistic setting. In this work, we report updates on the CaloScorearchitecture, detailing the changes in the diffusion process, which produces higher quality samples, and the use of progressive distillation, resulting in a diffusion model capable of generating new samples with a single function evaluation. Here we demonstrate these improvements using the Calorimeter Simulation Challenge 2022 dataset.

47 OTHER INSTRUMENTATION↗

Luminosity measurement for lead-lead collisions at $\sqrt{s_{\mathrm{NN}}}$ = 5.02 TeV in 2015 and 2018 at CMS

Measurements of the luminosity delivered to the CMS experiment during the lead-lead data-taking periods in 2015 and 2018 are presented for the first time. The collisions were recorded at a nucleon-nucleon center-of-mass energy of 5.02 TeV; the 2018 data sample is three times larger than the 2015 data sample. Three subdetectors are used: the pixel luminosity telescope, the forward hadron calorimeters, and the fast beam conditions monitor. The absolute luminosity calibration is determined using the van der Meer technique that relies on transverse beam separation scans. The dominant sources of uncertainty are the transverse factorizability of the bunch density profiles and, in 2015, the difference between the results obtained using various detectors. The total uncertainty in the integrated luminosity, including the stability of the calibrated subdetector response over time, amounts to 3.0% for 2015, 1.7% for 2018, and 1.6% for the combined data sample.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Plutonium-238 Loadout Calorimeter Return To Service

The calorimeter in the transfer area in Building 7920 at the US Department of Energy’s Oak Ridge National Laboratory is used to measure the amount of 238 Pu in the Plutonium Heat Source Oxide. The calorimetry measurement is taken after the oxide is packaged in an ORISC (Oak Ridge Inner Shipping Capsule)/FSO (Fuel Storage Outer) assembly before loading into the Containment Vessel and shipping container. The equipment is used in three specific configurations: zero measurement (nothing in the sample cup), FSO measurement (actual measurement of 238 Pu), and reference calibration measurement (using the reference FSO as a known heat source). System checks were performed in July 2023 in preparation for scheduled material loadout. During these checks, personnel discovered that the reference FSO had experienced an electrical short in the heater cable and was no longer functional. The calorimeter was in the reference calibration measurement configuration at this time. Facility management was notified when the damage was discovered. The data from the Yokogawa recorder were pulled and analyzed for a span of time between September 2022 and July 2023. An unusual spike was found in the sample cup temperature data that started on October 19, 2022, and ended on October 20, 2022. The sample cup reached a temperature of 191.1°C. The maximum allowable temperature for the calorimeter thermopile to reach is 220°C based on the manufacturer statement provided in Appendix B of this report [1]. The calorimeter thermopile and the sample cup thermocouple are physically close to each other; therefore, the data suggest that the calorimeter itself never saw a temperature in excess of 191.1°C. Physical damage present on the cable, tape, and insulation suggests that the temperature reached a higher value in some locations within the sample cup than the data shows. Because of this discrepancy, testing of the calorimeter was required to confirm that the calorimeter is functioning the same as it was before the electrical short. The intent of this report is to assess the functionality of the calorimeter and determine if it is acceptable to use for 238 Pu loadout material measurement. Testing showed that the calorimeter is functionally equivalent to the initial calibration that was performed in the summer of 2021, and thus, the calorimeter was cleared to be used for its intended purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observation and studies of jet quenching in PbPb collisions at {radical}(s{sub NN})=2.76 TeV

Jet production in PbPb collisions at a nucleon-nucleon center-of-mass energy of 2.76 TeV was studied with the Compact Muon Solenoid (CMS) detector at the LHC, using a data sample corresponding to an integrated luminosity of 6.7 {mu}b{sup -1}. Jets are reconstructed using the energy deposited in the CMS calorimeters and studied as a function of collision centrality. With increasing collision centrality, a striking imbalance in dijet transverse momentum is observed, consistent with jet quenching. The observed effect extends from the lower cutoff used in this study (jet p{sub T}=120 GeV/c) up to the statistical limit of the available data sample (jet p{sub T}{approx_equal}210 GeV/c). Correlations of charged particle tracks with jets indicate that the momentum imbalance is accompanied by a softening of the fragmentation pattern of the second most energetic, away-side jet. The dijet momentum balance is recovered when integrating low transverse momentum particles distributed over a wide angular range relative to the direction of the away-side jet.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development, calibration and experimental results obtained with an innovative calorimeter (CALMOS) for nuclear heating measurements

Nuclear heating inside an MTR reactor has to be known in order to be able to control samples temperature during irradiation experiments. An R and D program has been carried out at CEA to design a new type of in-core calorimetric system. This new development, started in 2002, has for main objective to manufacture a calorimeter suitable to monitoring nuclear heating inside the 70 MWth OSIRIS material testing reactor operated by CEA's Nuclear Energy Div. at the Saclay research center. An innovative calorimetric probe, associated to a specific handling system, has been designed to provide access to measurements both along the fissile height and on the upper part of the core, where nuclear heating still remains high. Two mock-ups of the probe were manufactured and tested in 2005 and 2009 in ex-core area of OSIRIS reactor for process validation, while a displacement system has been especially studied to move the probe along a given axial measurement range. This paper deals with the development, tests on preliminary mock-ups and the finalization of the probe. Main modeling and experimental results are presented. Moreover, alternative methods to calibration for nuclear heating rate measurements which are now possible with this new calorimeter are presented and discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development, calibration, and experimental results obtained with an innovative calorimeter (CALMOS) for nuclear heating measurements

Nuclear heating inside an MTR reactor has to be known in order to be able to control samples temperature during irradiation experiments. An R and D program has been carried out at CEA to design a new type of in-core calorimetric system. This new development, started in 2002, has for main objective to manufacture a calorimeter suitable to monitoring nuclear heating inside the 70 MWth OSIRIS material testing reactor operated by CEA's Nuclear Energy Division at the Saclay research center. An innovative calorimetric probe, associated to a specific handling system, has been designed to provide access to measurements both along the fissile height and on the upper part of the core, where nuclear heating still remains high. Two mock-ups of the probe were manufactured and tested in 2005 and 2009 in ex-core area of OSIRIS reactor for process validation, while a displacement system has been especially studied to move the probe along a given axial measurement range. This paper deals with the development, tests on preliminary mock-ups and the finalization of the probe. Main modeling and experimental results are presented. Moreover, alternative methods to calibration for nuclear heating rate measurements which are now possible with this new calorimeter are presented and discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Hydrothermal synthesis and luminescence properties of octahedral LiYbF{sub 4}: Er{sup 3+} microcrystals

Graphical abstract: LiYbF{sub 4}: Er{sup 3+} octahedral microcrystals have been successfully prepared through a facile hydrothermal method assisted with EDTA. SEM, HRTEM, RD, PL spectra are used to characterize the samples. It can be seen from SEM data that the complexing agent EDTA made to hydrothermal synthetic procedures result in formation of LiYbF{sub 4} octahedral microparticles with smooth surface. From the HRTEM images, the distances between the lattice fringes were measured to be 2.99 A and 2.57 A which correspond to the d-spacing for (1 1 2) and (2 0 0) planes, respectively. From the XRD patterns for the LiYb{sub 0.99}Er{sub 0.01}F{sub 4} in the absence of chelating agent EDTA and in the presence of EDTA, it is evident that the diffraction peaks of both patterns are highly crystalline and all of the peaks could be readily indexed to the LiYbF{sub 4} phase (JCPDS 71-1211). No other impurity peaks were detected. Under 976 nm excitation, the upconversion (UC) luminescence emission spectra of LiYbF{sub 4}: Er{sup 3+} microcrystals show the characteristic Er{sup 3+} emissions. The results show that the infrared light emissions at 792 nm of {sup 4}I{sub 9/2} {yields} {sup 4}I{sub 15/2} are dominantly strong unusually, while the green emissions at 526 and 545 nm assigned to {sup 2}H{sub 11/2} {yields} {sup 4}I{sub 15/2} and {sup 4}S{sub 3/2} {yields} {sup 4}I{sub 15/2}, respectively, and the red emission at 667 nm of {sup 4}F{sub 9/2} {yields} {sup 4}I{sub 15/2} are relatively weaker. Research highlights: {yields} Monodisperse and regular octahedral microcrystals LiYbF{sub 4}: Er{sup 3+} with smooth surface has been prepared. {yields} The characteristic emissions of Er{sup 3+} ions are observed in LiYbF{sub 4} microcrystals. {yields} The content of EDTA will influence the fluorescence intensity. {yields} Luminescence intensity increases gradually at the beginning and then decreases gradually with increasing temperature. -- Abstract: LiYbF{sub 4}: Er{sup 3+} octahedral microcrystals have been successfully prepared through a facile hydrothermal method assisted with EDTA (ethylenediaminetetraacetic acid). X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), high-resolution transmission electron microscopy (HRTEM), Fourier transform infrared spectroscopy (FTIR), thermogravimetric and differential scanning calorimeters (TG-DSC), photoluminescence (PL) spectra are used to characterize the samples. Under 976 nm excitation, the upconversion (UC) luminescence emission spectra of LiYbF{sub 4}: Er{sup 3+} microcrystals show the characteristic Er{sup 3+} emissions. The results show that the infrared light emissions at 792 nm of {sup 4}I{sub 9/2} {yields} {sup 4}I{sub 15/2} are dominantly strong unusually, while the green emissions at 526 and 545 nm assigned to {sup 2}H{sub 11/2} {yields} {sup 4}I{sub 15/2} and {sup 4}S{sub 3/2} {yields} {sup 4}I{sub 15/2}, respectively, and the red emission at 667 nm of {sup 4}F{sub 9/2}{yields}{sup 4}I{sub 15/2} are relatively weaker. Most importantly, the samples show more efficient luminescence with further heat treatment.

36 MATERIALS SCIENCE↗

Reproducibility and calibration of MMC-based high-resolution gamma detectors

Here, we describe a prototype γ-ray detector based on a metallic magnetic calorimeter with an energy resolution of 46 eV at 60 keV and a reproducible response function that follows a simple second-order polynomial. The simple detector calibration allows adding high-resolution spectra from different pixels and different cool-downs without loss in energy resolution to determine γ-ray centroids with high accuracy. As an example of an application in nuclear safeguards enabled by such a γ-ray detector, we discuss the non-destructive assay of 242 Pu in a mixed-isotope Pu sample.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Heat capacity measurements of sub-nanoliter volumes of liquids using bimaterial microchannel cantilevers

Lab-on-a-Chip compatible techniques for thermal characterization of miniaturized volumes of liquid analytes are necessary in applications such as protein blotting, DNA melting, and drug development, where samples are either rare or volume-limited. We developed a closed-chamber calorimeter based on a bimaterial microchannel cantilever (BMC) for sub-nanoliter level thermal analysis. When the liquid-filled BMC is irradiated with infrared (IR) light at a specific wavelength, the IR absorption by the liquid analyte results in localized heat generation and the subsequent deflection of the BMC, due to a thermal expansion mismatch between the constituent materials. The time constant of the deflection, which is dependent upon the heat capacity of the liquid analyte, can be directly measured by recording the time-dependent bending of the BMC. We have used the BMC to quantitatively measure the heat capacity of five volatile organic compounds. With a deflection noise level of ∼10 nm and a signal-to-noise ratio of 68:1, the BMC offers a sensitivity of 30.5 ms/(J g{sup −1 }K{sup −1}) and a resolution of 23 mJ/(g K) for ∼150 pl liquid for heat capacity measurements. This technique can be used for small-scale thermal characterization of different chemical and biological samples.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗