End-Use Savings Shapes Measure Documentation: Advanced Rooftop Unit Control

This technical report documents the Advanced Rooftop Unit Control End Use Savings Shapes (EUSS) measure, including providing a description of the technology, modeling methods, and the energy savings calculated from applying the measure to applicable across the US commercial building stock using ComStock to quantify its potential. Advanced rooftop unit controls (ARC) generally consist of a supply fan VFD, and controls to implement demand controlled ventilation (DCV) and air-side economizing, as a retrofit to improve energy efficiency of existing rooftop units (RTUs).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Thermostat Control for Load Shedding in Large Offices

This documentation focuses on a single End-Use Savings Shape measure - thermostat control for load shedding. The thermostat control for load shedding measure applies heating and cooling temperature setpoint offsets for reducing the heating and cooling load during peak window. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start and end times of the peak window, and then adjusts the thermostat cooling and/or heating setpoints by an offset value from original schedules during the peak window to reduce the HVAC or whole building daily peak load. The measure is flexible and allows users to adjust the heating and cooling offset values respectively, but for this study, the adjustment for heating and cooling setpoints are set to -2 degrees Celsius and +2 degrees Celsius by default. The measure provides options of adding rebound control period (default 2 hours) after peak windows for the setpoints to be ramped back to default values, to prevent the system from generating higher peak demand with step changes of setpoints in post-peak periods . This measure is applicable t o large offices equipped with electric HVAC system (either electric cooling only or both electric heating and cooling), which account for approximately 8.72% of the ComStock floor area. The thermostat control for load shedding measure demonstrates 2-5% daily peak demand reduction and 0.068% total site energy savings (3 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Thermostat Control for Load Shifting in Large Offices

This documentation focuses on a single end-use savings shape measure - thermostat control for load shifting. The thermostat control for load shifting measure applies heating and cooling temperature setpoint adjustment for pre-conditioning before the peak window. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start time of the peak window, and then adjusts the thermostat cooling or heating setpoints by a specified offset value from original schedules to precool or preheat the space , for a specified length of time before the start of peak window, and thus shifts load in the peak window to the pre-conditioning period. The measure is flexible and allows users to adjust the heating and cooling offset values and length of pre-conditioning period, but for this study, the load shifting strategy is applied as pre-cooling only (adjusting only cooling setpoints). The default adjustment for cooling setpoints is set to -1 degrees Celsius , and the default duration of pre-cooling is 1 hour. This measure is applicable to large offices equipped with electric HVAC system, which account for approximately 8.72% of the ComStock floor area. The thermostat control for load shifting measure demonstrates -1% daily peak demand reduction and 0% total site energy savings (0 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating Utility Costs Savings and Resilience: A Case Study in Port Arthur, Texas

This study evaluates the techno-economic feasibility of integrating solar photovoltaics (PV), battery energy storage systems (BESS), and generators to enhance both cost savings and resilience in critical community facilities in Port Arthur, Texas. Using NREL's REopt model, we analyze four facilities: the Golden Triangle Empowerment Center (GTEC), Lamar State College (LSC), Port Arthur Independent School District (PAISD), and Port Arthur Transit (PAT). A key aspect of the analysis is the incorporation of the Value of Lost Load (VoLL) and microgrid upgrade costs to assess the hidden value of resilience during grid outages. While standalone PV scenarios show moderate cost reductions and a 10-15% decrease in CO2 emissions, the inclusion of resilience measures with BESS and generators significantly increases system costs. However, the hidden value of resilience - quantified through avoided outage costs - leads to a substantial improvement in financial outcomes, resulting in positive Net Present Value (NPV) at many sites. The study demonstrates that resilient solar and storage systems offer both economic and resilience benefits, particularly for underserved communities, by balancing energy savings and enhanced operational continuity during outages.

14 SOLAR ENERGY↗

Bill Savings vs. Backup Power: Evaluating operational tradeoffs for home solar+storage systems [Slides]

Adoption of residential solar photovoltaic+energy storage systems (PVESS) is driven by both bill savings opportunities and customer demand for backup power. Prior work by this team (Gorman et al., 2022; Gorman et al., 2023) explored PVESS backup power capabilities during long-duration power interruptions (e.g., due to severe weather events), when customers are assumed to be able to anticipate the event and charge their batteries in advance. In many cases, however, power interruptions are unpredictable (and often relatively short); for those types of events, a customer will typically set its battery to maintain some minimum capacity in reserve in case of an interruption, which reduces the capacity available for managing utility bills. This study evaluates this operational tradeoff to help customers and installers configure backup reserve settings, and to inform decision-making more generally about the customer value of backup power services compared to utility bill savings. This study utilizes Berkeley Lab’s PRESTO tool to produce stochastic simulations of (predominantly short-duration) power interruption events, and builds on an earlier case-study demonstrating PVESS backup performance during short-duration interruptions (Baik et al., 2023).

14 SOLAR ENERGY↗

Methodology for Evaluating Energy Savings, Cost-Effectiveness, and Societal Impacts of Commercial Energy Code Changes

This document lays out the Department of Energy’s (DOE’s) methodology for evaluating the cost-effectiveness of energy code and standard proposals and editions. The evaluation is applied to new provisions or editions of ANSI/ASHRAE/IES Standard 90.1 and the International Energy Conservation Code. The methodology follows standard lifecycle cost (LCC) economic analysis procedures. A cost-effectiveness evaluation requires three steps: 1) evaluating the energy and energy cost savings of code changes; 2) evaluating the incremental and replacement costs related to the changes; and 3) determining the cost-effectiveness of energy code changes based on those costs and savings over time.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Potential Energy, Demand, Emissions, and Cost Savings Distributions for Buildings in a Utility’s Service Area

Several companies, universities, and national laboratories are developing urban-scale energy modeling that allows the creation of a digital twin of buildings for the simulation and optimization of real-world, city-sized areas. Prior to simulation-based assessment, a baseline of savings for a set of utility-defined use cases was established to clarify the initial business case for specific energy efficient building technologies. In partnership with a municipal utility, 178,337 OpenStudio and EnergyPlus models of buildings in the utility’s 1400 km 2 service area were created, simulated, and assessed with measures for quantifying energy, demand, cost, and emissions reductions of each building. The method of construction and assumptions behind these models is discussed, definitions of example measures are provided, and distribution of savings across the building stock is provided under a maximum technical adoption scenario.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Corroborative Evaluation of the Real-World Energy Saving Potentials of InfoRich Eco-Autonomous Driving (iREAD) System

There has been an increasing interest in exploring the potential to reduce energy consumption of future connected and automated vehicles. People have extensively studied various eco-driving implementations that leverage preview information provided by on-board sensors and connectivity, as well as the control authority enabled by automation. Quantitative real-world evaluation of eco-driving benefits is a challenging task. The standard regulatory driving cycles used for measuring exhaust emissions and fuel economy are not truly representative of real-world driving, nor for capturing how connectivity and automation might influence driving trajectories. To adequately consider real-world driving behavior and potential “off-cycle” impacts, this paper presents four collaborative evaluation methods: large-scale simulation, in-depth simulation, vehicle-in-the-loop testing, and vehicle road testing. These four approaches, spanning simulation and testing aspects, evaluate real-world fuel economy benefits with different ranges and resolutions. The large-scale simulations leverage an extensive real-world driving database to assess overall eco-driving benefits across a range of road network and driving scenarios. The real-world driving data are further leveraged to generate representative driving routes for deeper evaluation. Based on the representative routes, in-depth simulation relying on high-fidelity models investigates how different traffic scenarios can impact the eco-driving performance. The vehicle-in-the-loop setup reinforces the in-depth simulations by conducting tests with an actual vehicle operated on a chassis dynamometer; the measured energy savings were indeed found to agree with the in-depth simulation savings estimates. Finally, limited but representative road testing with the fully integrated vehicle will be conducted to demonstrate the eco-driving capability and conclude the overall evaluation regimen.

ARPA-E↗

Integrated and Advanced Lighting Controls: The Next Frontier in Energy Savings?

Lighting energy use has significantly declined as a portion of overall building energy usage due largely to the uptake of more efficient light-emitting diode technology. Although the per unit cost of lighting controls has declined, the installation and use of lighting controls are low and the installation and use of advanced controls are abysmally low. Increased use of advanced and connected lighting controls, and the ability to integrate lighting with other building systems (e.g., heat and air, plug loads, miscellaneous loads) that make the building “smarter,” offer the potential for additional energy savings. Studies into the performance of new, advanced lighting control technologies in commercial buildings have generated new findings. Although each field evaluation has interesting results individually, an analysis of their collective findings across a spectrum of commercial building types will help establish the current state of the technology and implications related to market readiness. This paper will analyze results from available field evaluation studies (recently completed as well as ongoing) of retrofit sites and share findings and insights including: • The amount of energy savings that may be expected from these systems. • Cost effectiveness, monetization, and cost points of these systems. • Ideal characteristics of these systems the most viable. • Lessons learned from the installation, commissioning, and occupant response of these systems. The results will support Department of Energy research investments and help inform efficiency programs of the potential of these emerging technologies and how they may fit within the clean energy future.

Myer, Michael↗

Energy Credits—A New Way to Save in ASHRAE/IES Standard 90.1-2022

This article discusses a new Section 11 that has been added to Standard 90.1-2022 to increase energy savings by requiring additional energy credit measures beyond the base prescriptive requirements. This new requirement targets a 5% reduction in overall building energy cost using a broad range of additional measures. Allowing designers to choose measures that are particularly suited to a particular project provides flexibility in increasing energy savings. There are resources available to help designers implement this new requirement in Standard 90.1.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy Saving Estimation of ASHRAE Guideline 36 Supervisory Setpoint Reset Controls in a Commercial Large Office Building

Designing, commissioning, and retrofitting HVAC control systems for energy efficiency is crucial, but the use of ad-hoc control sequences by designers and contractors, based on scattered information, results in diverse and sub-optimal sequences. ASHRAE Guideline 36 (G36) addresses the challenge by providing standardized, rule-based HVAC control sequences that prioritize energy efficiency. However, there is limited evaluation of their energy performance at the building level, with only a few studies primarily focused on HVAC airside systems in small-to-medium-sized commercial buildings. In this study, the energy performance of ASHRAE Guideline 36 control sequences was assessed using a large office building emulator in Chicago. The emulator features a central plant system with multiple chillers and boilers as well as multiple variable air volume (VAV) systems with terminal reheat. To achieve a high-fidelity representation, we developed a Spawn-of-EnergyPlus-based model for the large office building, maintaining the DOE prototype large office building setup but substituting the HVAC system with its Modelica counterpart. This substitution ensures that the building thermal load, HVAC system's dynamics, and detailed control sequences are all accurately represented. The study involved evaluating and implementing control strategies outlined in ASHRAE Guideline 36-2021 to replace conventional controls. These strategies include the demand-based supply air temperature and duct static pressure setpoint reset and the request logic for demand-based reset of chilled/hot water supply temperature setpoints and pipe static pressure setpoints. Energy performance was evaluated under various load conditions, including cooling, heating, and transitional seasons, both for individual control strategies and in combination. The results indicate that the collective control strategies retrofit yield greater energy savings than the sum of individual strategies, highlighting the synergistic benefits of incorporating both airside and plant-side control retrofits. Additionally, energy savings of up to 41% in the heating season, 18% in the shoulder season, and 20 % in the cooling season were observed compared to baseline control while maintaining the thermal comfort level.

ASHRAE Guideline 36, Commercial buildings, Control↗

Thermoelectric air conditioning undergarment for personal thermal management and HVAC energy saving

Personal thermal management systems (PTMS) are highly desirable for improving individual thermal comfort and reducing indoor HVAC energy consumption. Although there have been many attempts in developing PTMS, existing PTMS are generally bulky, heavy or immobile. Besides, previous analysis on additional personal cooling and heating power required for maintaining thermal comfort in changing environments did not consider the individual difference in metabolism and the variability of comfort skin temperature with environmental conditions. In this paper, we report on the development of a novel lightweight (<1 kg) thermoelectric air conditioning undergarment system with a preferred design of branching tubing network (branching angle of 60° and diameter ratio of 0.782) for air distribution. Through thermal manikin and human subject tests, we demonstrated that the novel system is capable of providing a maximum of 15.5 W of personal cooling and 18.1 W personal heating with a coefficient of performance (COP) greater than 0.4, which is sufficient to the expansion of the indoor set-points by at least 2.2 °C (4 °F) on both sides without compromising thermal comfort and the potential saving of about 15% HVAC energy. Furthermore, our study improved the understanding of the required additional personal cooling and heating power for changing environmental conditions, which are essential guidelines for the further development of PTMS.

42 ENGINEERING↗

Energy savings and life cycle cost analysis of advanced double skin facade system applied to old apartments in South Korea

South Korea is one of the most densely populated countries in the world, and the population density in urban areas is much higher among others. Apartments are the most common form of residential buildings due to their high population density. More than 60% of domestic residential buildings are apartments, with more than 10 million households. The high population density is a problem that has long plagued South Korea because more than 45% of apartments are old apartments that are more than 20 years old. Old apartment buildings have low thermal performance that results in lots of energy consumption. Balconies, which worked as a thermal buffer, are also being removed by residents to expand indoor space. According to the green remodeling project supported by the Korean government, the typical retrofitting method is replacing external windows with the high-efficiency window in old apartments in South Korea. Here, this paper proposes a retrofitting method using an extended double-skin façade (DSF) system that replaces exterior windows and acts as a thermal buffer. The simulation model is developed with the EnergyPlus simulation program to conduct energy performance analyses. The simulation model has been calibrated using actual experimental data collected between October 1, 2019, and January 15, 2020. Results show that the cooling, heating, and lighting energy can be reduced up to 44.1% by fully utilizing electric energy generated by solar PV panels integrated with the DSF system. The payback period is about 15 years based on the energy price provided by the utility company. Although the payback period is long, it has great potential of energy savings and CO 2 emission reductions. The DSF system should be considered as a way of renovation, considering other factors such as increased real estate values and energy cost increases in the future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Printable, emissivity-adaptive and albedo-optimized covering for year-round energy saving

Radiative cooling uses high-emissivity materials to passively cool the surface of outdoor objects, such as building roofs on hot days. The issue of overcooling with this technology on cold days can be addressed by structures with thermal emissivity that is adaptive to temperature. Despite recent advances in temperature-adaptive structures, great challenges remain in their fabrication feasibility and unoptimized solar heating that may override the radiative cooling benefit. Here, in this work, we develop a printable, emissivity-adaptive and albedo-optimized covering (PEAC) based on recyclable materials with roll-to-roll fabrication. A PEAC automatically switches its sky-window emissivity from 0.25 to 0.85 when the surface temperature exceeds a pre-set transition temperature, delivering an albedo optimized for maximal year-round energy saving or thermal comfort in a given climate.

36 MATERIALS SCIENCE↗

A non-volatile thermal switch for building energy savings

Compared with traditional static insulation, a thermally switchable building envelope could reduce annual heating and cooling loads by intermittently coupling to the outside environment when beneficial. Here, we demonstrate a voltage-actuated, contact/non-contact thermal switch that meets the unique challenges of this application. The switch is non-volatile, consuming electricity only briefly while switching and none to hold steady state. The switch ratio is 12, the off state has a low effective thermal conductivity of 0.045 W m -1 K -1 , comparable to fiberglass insulation, and the performance is stable over 1,000 switching cycles. Numerical simulations using real-world climate data show that combining this thermal switch with a thermal storage layer in a building envelope can yield annual energy savings of 9%-55% (heating) and 17%-76% (air conditioning), depending on the climate zone. The greatest benefits are realized when the exterior temperature crosses well above and below the desired interior temperature within a single 24 h period.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

BEPAM Model Code and CABBI Simulation Results for "Assessing the Returns to Land and Greenhouse Gas Savings from Producing Energy Crops on Conservation Reserve Program Land"

This dataset contains BEPAM model code and input data to the replicate the results for "Assessing the Returns to Land and Greenhouse Gas Savings from Producing Energy Crops on Conservation Reserve Program Land." The dataset consists of: (1) The replication codes and data for the BEPAM model. The code file is named as output_0213-2020_Complete_daycent-agversion-[rental payment level]%_[biomass price].gms. (BEPAM-CRP model-Sep2020.zip) (2) Simulation results from the BEPAM model (BEPAM_Simulation_Results.csv) * Item (1) is in GAMS format. Item (2) is in text format.

biomass price↗

End-Use Savings Shapes: Public Dataset Release for Residential Round 1 [Slides]

The End-Use Load Profiles project created a public database of 900,000 individual building end-use load profiles. Load profiles were modeled to represent the U.S. building stock as it was in 2018, as nearly as possible based on the best available data. The End-Use Savings Shapes follow-on project adds measure impact profiles for energy efficiency and electrification packages to the public dataset. This presentation details the public dataset release on September 20, 2022.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗