Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensor Integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Raman Spectroscopic In Situ Monitoring of Highly Turbid Media

The ability to run chemical processing more efficiently and cost effectively is a need that spans critical materials recovery and legacy nuclear waste cleanup. Sensors integrated to provide online monitoring are essential to addressing this need by providing near-real time feedback on process conditions, which can improve efficiency, aid in decision making, and reduce the need for grab sample measurements. Optical spectroscopy is well-suited for providing online chemical composition information and has been widely applied in varied chemical systems. However, applications in turbid matrices continue to represent substantial challenges to sensor performance, where absorption or scattering of excitation light can cause significant signal interference. Here, in this study, close-focus Raman probes are investigated for use in turbid media as a way to overcome the signal loss from the scattering of the Raman excitation source. This, paired with advanced data science techniques, allowed for the development of chemometric models for the accurate quantification of several analytes of interest (NO 3 – , NO 2 – , and PO 4 3– ) in highly turbid solutions with solids loadings of up to 20 wt %. This work focuses on offline sample measurement and characterization as an initial step toward the development of online monitoring capabilities. Chemical systems of interest were focused on nuclear waste at the Hanford Site, which represents highly complex matrices that could realize significant processing benefits through the integration of online monitoring.

Felmy, Heather M. [Pacific Northwest National Labo↗

Novel real-time 3D radiological mapping solution for ALARA maximization, D and D assessments and radiological management

Good management of dismantling and decontamination (D and D) operations and activities is requiring safety, time saving and perfect radiological knowledge of the contaminated environment as well as optimization for personnel dose and minimization of waste volume. In the same time, Fukushima accident has imposed a stretch to the nuclear measurement operational approach requiring in such emergency situation: fast deployment and intervention, quick analysis and fast scenario definition. AREVA, as return of experience from his activities carried out at Fukushima and D and D sites has developed a novel multi-sensor solution as part of his D and D research, approach and method, a system with real-time 3D photo-realistic spatial radiation distribution cartography of contaminated premises. The system may be hand-held or mounted on a mobile device (robot, drone, e.g). In this paper, we will present our current development based on a SLAM technology (Simultaneous Localization And Mapping) and integrated sensors and detectors allowing simultaneous topographic and radiological (dose rate and/or spectroscopy) data acquisitions. This enabling technology permits 3D gamma activity cartography in real-time. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radio-Frequency (RF) Devices for Safeguards: Where We Are and Where We Need to Go

Radio-Frequency (RF) devices have revolutionized many aspects of modern industrial processes. RF technology can enable wireless communication for tag identification, sensor communication, and asset tracking. Radio-frequency identification (RFID) is a technology that utilizes wireless communication to interrogate and identify an electronic tag attached to an item in order to identify the item. The technology can come in many forms: passive or active tags, low to ultra-wideband frequencies, small paper-thin tags to brick-sized units, and simple tags or highly integrated sensor packages. RF technology, and specifically RFID, has been applied widely in commercial markets for inventory, supply chain management, and asset tracking. Several recent studies have demonstrated the safeguards benefits of utilizing RFID versus conventional inventory tagging methods for tracking nuclear material. These studies have indicated that the RF requirements for safeguards functions are more stringent than the RF requirements for other inventory tracking and accounting applications. Additionally, other requirements must be addressed, including environmental and operating conditions, authentication, and tag location and attachment. Facility restrictions on radio spectrum, method of tag attachment, and sensitivity of the data collected impact the tag selection and system design. More important, the intended use of the system must be considered. The requirements for using RF to simply replace or supplement container identifiers such as bar codes that facilitate the inventory function will differ greatly from the requirements for deploying RF for unattended monitoring applications. Several studies have investigated these considerations to advance commercial RF devices for safeguards use, and a number of system concepts have been developed. This paper will provide an overview of past studies and current technologies, and will investigate the requirements, existing gaps, and several potential next steps for advancing RF techniques for safeguards use.

Radio-Frequency Identification↗

CMOS Integrated Carbon Nanotube Sensor

Recently carbon nanotubes (CNTs) have been gaining their importance as sensors for gases, temperature and chemicals. Advances in fabrication processes simplify the formation of CNT sensor on silicon substrate. We have integrated single wall carbon nanotubes (SWCNTs) with complementary metal oxide semiconductor process (CMOS) to produce a chip sensor system. The sensor prototype was designed and fabricated using a 0.30 um CMOS process. The main advantage is that the device has a voltage amplifier so the electrical measure can be taken and amplified inside the sensor. When the conductance of the SWCNTs varies in response to media changes, this is observed as a variation in the output tension accordingly.

36 MATERIALS SCIENCE↗

Skipper-in-CMOS: Nondestructive Readout With Subelectron Noise Performance for Pixel Detectors

The Skipper-in-CMOS image sensor integrates the nondestructive readout capability of skipper charge coupled devices (Skipper-CCDs) with the high conversion gain of a pinned photodiode (PPD) in a CMOS imaging process while taking advantage of in-pixel signal processing. This allows both single photon counting as well as high frame rate readout through highly parallel processing. The first results obtained from a ${15} \times {15}~\mu $ m2 pixel cell of a Skipper-in-CMOS sensor fabricated in Tower Semiconductor’s commercial 180-nm CMOS image sensor process are presented. Measurements confirm the expected reduction of the readout noise with the number of samples down to deep subelectron noise of $0.15\text {e}^ - $ , demonstrating the charge transfer operation from the PPD and the single photon counting operation when the sensor is exposed to light. This article also discusses new testing strategies employed for its operation and characterization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A microfabricated fringing field capacitive pH sensor with an integrated readout circuit

This work presents a microfabricated fringe-field capacitive pH sensor using interdigitated electrodes and an integrated modulation-based readout circuit. The changes in capacitance of the sensor result from the permittivity changes due to pH variations and are converted to frequency shifts using a crossed-coupled voltage controlled oscillator readout circuit. The shift in resonant frequency of the readout circuit is 30.96 MHz for a change in pH of 1.0–5.0. The sensor can be used for the measurement of low pH levels, such as gastric acid, and can be integrated with electronic pills. The measurement results show high repeatability, low noise, and a stable output.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Autonomous Sensor System for Wind Turbine Blade Collision Detection

This paper presents an automated blade collision detection system for use on wind turbines, toward the goal of supporting monitoring and quantitative assessment of wind energy impacts on wildlife. A wireless, multisensor module mounted at the blade root measures surface vibrations, and a blade-mounted camera provides image capture of colliding objects. Using sensor data recorded during field testing of the system on an operational wind turbine, we present the development, training, and testing of automated detection algorithms for collision detection using machine-learning approaches. In particular, we compare the use of a new two-step, anomaly-based classification algorithm with conventional adaptive boosting and amplitude-based detection techniques, where the two-step approach improves average precision for the experimental data set. This integrated sensor and classification systems demonstrates a new approach for automated, on-blade collision detection for wind turbines, with broad utility across structural health monitoring applications.

17 WIND ENERGY↗

Comparative Kinetic Analysis of Closed-Ended and Open-Ended Porous Sensors

Efficient mass transport through porous networks is essential for achieving rapid response times in sensing applications utilizing porous materials. In this work, we show that open-ended porous membranes can overcome diffusion challenges experienced by closed-ended porous materials in a microfluidic environment. A theoretical model including both transport and reaction kinetics is employed to study the influence of flow velocity, bulk analyte concentration, analyte diffusivity, and adsorption rate on the performance of open-ended and closed-ended porous sensors integrated with flow cells. The analysis shows that open-ended pores enable analyte flow through the pores and greatly reduce the response time and analyte consumption for detecting large molecules with slow diffusivities compared with closed-ended pores for which analytes largely flow over the pores. Experimental confirmation of the results was carried out with open- and closed-ended porous silicon (PSi) microcavities fabricated in flow-through and flow-over sensor configurations, respectively. The adsorption behavior of small analytes onto the inner surfaces of closed-ended and open-ended PSi membrane microcavities was similar. However, for large analytes, PSi membranes in a flow-through scheme showed significant improvement in response times due to more efficient convective transport of analytes. The experimental results and theoretical analysis provide quantitative estimates of the benefits offered by open-ended porous membranes for different analyte systems.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A core of cell wall proteins functions in wall integrity responses in Arabidopsis thaliana

Abstract Cell walls surround all plant cells, and their composition and structure are tightly regulated to maintain cellular and organismal homeostasis. In response to wall damage, the cell wall integrity (CWI) system is engaged to ameliorate effects on plant growth. Despite the central role CWI plays in plant development, our current understanding of how this system functions at the molecular level is limited. Here, we investigated the transcriptomes of etiolated seedlings of mutants of Arabidopsis thaliana with defects in three major wall polysaccharides, pectin ( quasimodo2 ), cellulose ( cellulose synthase3 je5 ), and xyloglucan ( xyloglucan xylosyltransferase1 and 2 ), to probe whether changes in the expression of cell wall‐related genes occur and are similar or different when specific wall components are reduced or missing. Many changes occurred in the transcriptomes of pectin‐ and cellulose‐deficient plants, but fewer changes occurred in the transcriptomes of xyloglucan‐deficient plants. We hypothesize that this might be because pectins interact with other wall components and/or integrity sensors, whereas cellulose forms a major load‐bearing component of the wall; defects in either appear to trigger the expression of structural proteins to maintain wall cohesion in the absence of a major polysaccharide. This core set of genes functioning in CWI in plants represents an attractive target for future genetic engineering of robust and resilient cell walls.

59 BASIC BIOLOGICAL SCIENCES↗

Integrated system to reduce emissions from natural gas-fired reciprocating engines

Natural gas-fired reciprocating engines (NGFRE), which are naturally aspirated are used in the oil and gas industry for the production, storage, processing, and transmission of natural gas extracted from wells. These stationary, lean-burn engines exhibit increased combustion instability and higher emissions of methane (CH 4 ) and Volatile Organic Compounds (VOCs) at lower loads, resulting in restrictions on the operational envelope of such engines. Here, in this paper, some of the emission reduction technologies for NGFREs are reviewed. Also, an experimental investigation of an integrated system to reduce emissions and improve the combustion performance of an NGFRE is presented. The integrated system consists of an air management package and integrated sensors including an amperometric NOx/O 2 sensor, exhaust temperature thermocouple, pressure transducers and vibration sensors. Experiments were carried out using natural gas and natural gas/propane blends at different load steps, and combustion performance, as well as emissions, were analyzed. For natural gas fuel, the results show that the standard deviation of peak pressure and indicated thermal efficiency (ITE) improved by 67.4 psi and 4.2% respectively, at 40% load. Similarly, CH 4 and Nitrogen Oxides (NOx) emissions reduced considerably by 84% and 63% respectively. However, CO emissions increased from 8 ppm to 152 ppm. At 60% load, the ITE improved by 3.8% and the CH 4 emissions were reduced by 68%. The reduction in VOCs emissions was 63% at 40% load and 69% at 60% load. The findings of this research provide evidence of the effectiveness of the integrated air management system in improving the sustainability of NGFREs. In general, this technology can be implemented on air-assisted combustion applications to improve combustion performance and, consequently, reduce emissions.

33 ADVANCED PROPULSION SYSTEMS↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Innovative approach to counterfeit and noncompliant refrigerant detection: A cost-effective, portable solution

The increasing prevalence of counterfeit and incompatible refrigerants presents significant risks to Heating, Ventilation, Air Conditioning, and Refrigeration (HVAC&R) systems, including compromised equipment performance, safety hazards, and non-compliance. This article details the development of a novel, cost-effective, and portable detection device designed to accurately verify refrigerants. The device utilizes a controlled gas sampling and analysis system within a sealed chamber, ensuring precise measurements while maintaining safety through a purging mechanism. The system features a high-sensitivity sensor integrated with an onboard control module that analyzes gas composition in real-time, providing feedback within a 2-minute duration. Laboratory validation demonstrated the device’s high accuracy (>95 % based on correct identification of compliant vs. non-compliant blends) in detecting unauthorized refrigerant blends. The projected cost of the product stands at ∼ $150, based on the retail pricing of individual components. Laboratory validation demonstrated the device’s high accuracy (>95 % for composition identification, 100 % rejection of tested counterfeit/incorrect blends) in detecting unauthorized refrigerant blends with a response time <2 min. The device correctly identified authentic R-454A/B/C blends and reliably rejected R-407F and closely related counterfeit mixtures. Key advantages include affordability, ease of use, rapid response time, and compatibility with a wide range of refrigerants. This solution supports compliance with regulatory frameworks, enhances safety in HVAC&R operations, and mitigates the risks associated with counterfeit refrigerants.

Counterfeit refrigerants↗

Biaxial Tensile Strain Enhances Electron Mobility of Monolayer Transition Metal Dichalcogenides

Strain engineering can modulate the material properties of two-dimensional (2D) sem- iconductors for electronic and optoelectronic applications. Recent theory and experiments have found that uniaxial tensile strain can improve the electron mobility of monolayer MoS 2 , a 2D semiconductor, but the effects of biaxial strain on charge transport are not well-understood in 2D semiconductors. Here, we use biaxial tensile strain on flexible substrates to probe the electron mobility in monolayer WS 2 and MoS 2 transistors. Further, this approach experimentally achieves ~2× higher on-state current and mobility with ~0.3% applied biaxial strain in WS 2 , the highest mobility improvement at the lowest strain reported to date. We also examine the mechanisms behind this improvement through density functional theory simulations, concluding that the enhancement is primarily due to reduced intervalley electron-phonon scattering. These results underscore the role of strain engineering 2D semiconductors for flexible electronics, sensors, integrated circuits, and other opto-electronic applications.

2D materials↗

GLM Observations of the Brightest Lightning in the Americas

Two years of Geostationary Lightning Mapper (GLM) science data are used to document the brightest lighting flashes observed on the Americas continent. The most radiant optical lightning emissions—termed “superbolts”—were first identified by the Vela satellite constellation in the 1970s (Turman, 1977) and are defined in terms of peak optical power. GLM is an integrating sensor that, instead, measures the total optical energy from a lightning pulse. Furthermore, while GLM might not correctly classify short-duration superbolts, its top lightning cases certainly fall in the superbolt category, and the wealth of GLM measurements over its stationary hemispheric field of view provide an unmatched sample of extraordinarily bright lightning. While radiant bolts in excess of 100× the optical energy of typical lightning are ubiquitous across the Americas and result from many types of lightning processes, we find the most radiant cases (>1,000×) are concentrated in the central United States and in the La Plata basin in South America. Coincident Earth Networks Global Lightning Network (ENGLN) observations reveal that these extremely bright emissions usually result from + CG strokes with high peak currents in long horizontal flashes outside of the convective core. Single cases of these megaflashes might produce multiple superbolts over their durations.

54 ENVIRONMENTAL SCIENCES↗

Multi‐Sensor Trajectory Reconstruction of the 24 April 2025 Alaska Fireball and Implications for Planetary Defense

On 24 April 2025 at 18:30:57 UTC, a bright daytime fireball over Southcentral Alaska was detected by 37 seismic stations, 16 single infrasound sensors, and four infrasound arrays, yielding 30 ballistic and multiple fragmentation arrivals. Here, the unprecedented density of seismoacoustic coverage enabled detailed reconstruction of the event using acoustic signals, with fragmentation source locations further guiding the identification of Doppler weather radar signatures of a meteorite fall. Incorporation of a radar-derived terminal point yielded a final trajectory solution, which agreed closely with an independent optical trajectory solution from video analysis. The reconstructed entry parameters from seismoacoustic analysis indicate a velocity of 25.3 km/s, an entry angle of 19°, and an energy release of ∼38 t TNT equivalent. Assuming a chondritic composition, the pre-entry object diameter was ∼0.7 m. Using orbital parameters from the optical solution, we estimate meteoroid composition as most likely an L-type ordinary chondrite. The event occurred in the sub-Arctic, where space-based optical systems face challenges in detection, demonstrating the critical role of dense ground-based seismoacoustic networks in characterizing high-latitude atmospheric entries. This uniquely well-recorded event demonstrates the capability of dense seismoacoustic networks to constrain bolide trajectories, energetics, and fragmentation, with radar and optical data providing critical confirmation and complementary perspectives. These results bridge the methodological gap between planetary-defense monitoring of natural impactors and space-traffic analyses of artificial reentries, illustrating how multi-sensor integration can deliver calibration-grade trajectories even for unpredicted events.

Fireball↗

Development and flight-testing of modular autonomous cultivation systems for biological plastics upcycling aboard the ISS

Cultivation of microorganisms in space has enormous potential to enable in-situ resource utilization (ISRU) Here, we develop an autonomous payload with fully programmable serial passaging and sample preservation, termed the Modular Open Biological Platform (MOBP), and flight-test the MOBP aboard the International Space Station (ISS) by conducting enzymatic and microbial plastics upcycling experiments. The MOBP is a compact, modular bioreactor system that allows for sustained microbial growth via automated media transfers, such as those for sample collection and storage for terrestrial analyses, and precise data monitoring from integrated sensors. The MOBP was flight-tested with two experiments designed to evaluate biological upcycling of the plastic poly(ethylene terephthalate) (PET). The bioproduct βKA can be polymerized into a nylon-6,6 analog with improved properties for use in the production of a variety of materials. We posit the MOBP will aid in democratizing the execution of synthetic biology in spaceflight towards enabling ISRU.

09 BIOMASS FUELS↗

Embedding thermocouples in SS316 with laser powder bed fusion

Recent advances in manufacturing technologies have enabled the fabrication of complex geometries for a wide range of applications, including the energy, aerospace, and civil sectors. The ability to integrate sensors at critical locations within these complex components during the manufacturing process could benefit process monitoring and control by reducing reliance on models to relate surface measurements to internal phenomena. This study investigated embedding thermocouples in a SS316 matrix using laser powder bed fusion. Under optimal processing conditions, embedded thermocouples were characterized post-building, finding good bonding to the matrix with no melt pool penetration to the sensing elements. Futher, the embedded thermocouple performed similarly to an identical non-embedded thermocouple during thermal testing to 500 °C with only a slight difference in response time, which was attributed to the differences in mass and the associated thermal time constants.

image analysis↗