Search NASA⌕ Search

SEARCH · Search NASA

Results for “Shading control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

The 1991-1992 project summaries

The Department of Mechanical Engineering at The University of Texas at Austin participated in seven cooperative design projects this year. Six of the projects were associated with the Johnson Space Center and include the design of a thermal control system for an inflatable lunar habitat module, a vibration isolation system for a space shuttle cycle ergometer, a radiator shading device for a lunar outpost, a reusable astronaut safety tether, a resistive exercise device for use on the space shuttle, and a fleet of autonomous regolith throwing devices for radiation shielding of lunar habitats. The seventh project is associated with the Jet Propulsion Lab and involves the design of a shock absorbing wheel for a small six-wheeled Martian rover vehicle.

Nichols, Steven P.↗

Architectures and Control of Submodule Integrated DC-DC Converters for Photovoltaic Applications

This paper describes photovoltaic (PV) module architectures with parallel-connected submodule-integrated dc-dc converters (subMICs) that improve efficiency of energy capture in the presence of partial shading or other mismatch conditions. The subMICs are bidirectional isolated dc-dc converters capable of injecting or subtracting currents to balance the module substring voltages. When no mismatches are present, the subMICs are simply shut down, resulting in zero insertion losses. It is shown that the objective of minimum subMIC power processing can be solved as a linear programming problem. A simple close-to-optimal distributed control approach is presented that allows autonomous subMIC control without the need for a central controller or any communication among the subMICs. Furthermore, the proposed control approach is well suited for an isolated-port architecture, which yields additional practical advantages including reduced subMIC power and voltage ratings. The architectures and the control approach are validated by simulations and experimental results using three bidirectional flyback subMICs attached to a standard 180-W, 72-cell PV module, yielding greater than 98% module-level power processing efficiency for a mismatch less than 25%.

Olalla, C↗

Efficient modeling of optically-complex, non-coplanar exterior shading: Validation of matrix algebraic methods

It has long been established that shading windows with overhangs, fins, and other types of non-coplanar systems (NCS) is one of the most effective ways of controlling solar heat gains in buildings because they intercept solar radiation prior to entry into the building. Designers however often specify non-opaque materials (e.g., louvers, fritted glass, expanded metal mesh) for these systems in order to admit daylight, reduce lighting energy use, and improve indoor environmental quality. Most simulation tools rely on geometric calculations and radiosity methods to model the solar heat gain impacts of NCS and cannot model optically-complex materials or geometries. For daylighting analysis, optically-complex NCS can be modeled using matrix algebraic methods, although time-efficient parametric analysis has not yet been implemented. Determining the best design and/or material for static or operable NCS that minimize cooling, heating, and lighting energy use and peak demand requires an iterative process. This study describes and validates a matrix algebraic method that enables parametric energy analysis of NCS. Such capabilities would be useful not only for design but also for development of prescriptive energy-efficiency standards, rating and labeling systems for commercial products, development of design guidelines, and development of more optimal NCS technologies. A facade or “F” matrix, which maps the transfer of flux from the NCS to the surface of the window, is introduced and its use is explained. A field study was conducted in a full-scale outdoor testbed to measure the daylight performance of an operable drop-arm awning. Simulated data were compared to measured data in order to validate the models. Results demonstrated model accuracy: simulated workplane illuminance was within 11–13%, surface luminance was within 16–18%, and the daylight glare probability was within 6–9% of measured results. Methods used to achieve accurate results are discussed. Results of the validation of daylighting performance are applicable to solar heat gain performance. Since exterior shading can also significantly reduce peak demand, these models enable stakeholders to more accurately assess HVAC and lighting impacts in support of grid management and resiliency goals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mycorrhizal phenotypes and the L aw of the M inimum

Summary Mycorrhizal phenotypes arise from interactions among plant and fungal genotypes and the environment. Differences in the stoichiometry and uptake capacity of fungi and plants make arbuscular mycorrhizal ( AM ) fungi inherently more nitrogen (N) limited and less phosphorus (P) limited than their host plants. Mutualistic phenotypes are most likely in P‐limited systems and commensal or parasitic phenotypes in N‐limited systems. Carbon (C) limitation is expected to cause phenotypes to shift from mutualism to commensalism and even parasitism. Two experiments compared the influence of fertilizer and shade on mycorrhizas in A ndropogon gerardii across three naturally N‐limited or P‐limited grasslands. A third experiment examined the interactive effects of N and P enrichment and shade on A . gerardii mycorrhizas. Our experiments generated the full spectrum of mycorrhizal phenotypes. These findings support the hypothesis that mutualism is likely in P‐limited systems and commensalism or parasitism is likely in N‐limited systems. Furthermore, shade decreased C‐assimilation and generated less mutualistic mycorrhizal phenotypes with reduced plant and fungal biomass. Soil fertility is a key controller of mycorrhizal costs and benefits and the L aw of the M inimum is a useful predictor of mycorrhizal phenotype. In our experimental grasslands arbuscular mycorrhizas can ameliorate P‐limitation but not N‐limitation.

Johnson, Nancy Collins↗

Prototype part task trainer: A remote manipulator system simulator

The Part Task Trainer program (PTT) is a kinematic simulation of the Remote Manipulator System (RMS) for the orbiter. The purpose of the PTT is to supply a low cost man-in-the-loop simulator, allowing the student to learn operational procedures which then can be used in the more expensive full scale simulators. PTT will allow the crew members to work on their arm operation skills without the need for other people running the simulation. The controlling algorithms for the arm were coded out of the Functional Subsystem Requirements Document to ensure realistic operation of the simulation. Relying on the hardware of the workstation to provide fast refresh rates for full shaded images allows the simulation to be run on small low cost stand alone work stations, removing the need to be tied into a multi-million dollar computer for the simulation. PTT will allow the student to make errors which in full scale mock up simulators might cause failures or damage hardware. On the screen the user is shown a graphical representation of the RMS control panel in the aft cockpit of the orbiter, along with a main view window and up to six trunion and guide windows. The dials drawn on the panel may be turned to select the desired mode of operation. The inputs controlling the arm are read from a chair with a Translational Hand Controller (THC) and a Rotational Hand Controller (RHC) attached to it.

Shores, David↗

Performance Study of Swimming Pool Heaters

The objective of this report is to perform a controlled laboratory study on the efficiency and emissions of swimming pool heaters based on a limited field investigation into the range of expected variations in operational parameters. Swimming pool heater sales trends have indicated a significant decline in the number of conventional natural gas-fired swimming pool heaters (NGPH). On Long Island the decline has been quite sharp, on the order of 50%, in new installations since 2001. The major portion of the decline has been offset by a significant increase in the sales of electric powered heat pump pool heaters (HPPH) that have been gaining market favor. National Grid contracted with Brookhaven National Laboratory (BNL) to measure performance factors in order to compare the relative energy, environmental and economic consequences of using one technology versus the other. A field study was deemed inappropriate because of the wide range of differences in actual load variations (pool size), geographic orientations, ground plantings and shading variations, number of hours of use, seasonal use variations, occupancy patterns, hour of the day use patterns, temperature selection, etc. A decision was made to perform a controlled laboratory study based on a limited field investigation into the range of expected operational variations in parameters. Critical to this are the frequency of use, temperature selection, and sizing of the heater to the associated pool heating loads. This would be accomplished by installing a limited amount of relatively simple compact field data acquisition units on selected pool installations. This data included gas usage when available and alternately heater power or gas consumption rates were inferred from the manufacturer's specifications when direct metering was not available in the field. Figure 1 illustrates a typical pool heater installation layout.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Beyond Widgets: Validated Systems Energy Savings and Utility Custom Incentive Program Systems Trends

Energy efficiency upgrades to buildings to date through avenues such as utility incentive programs have been largely limited to component-based products (e.g., lamps, RTUs). While some utilities do provide ‘custom’ incentive programs with whole building and system level technical assistance, these programs require deeper levels of analysis, resulting in higher program costs. This results in custom programs being restricted to utilities with greater resources, and are typically applied mainly to large or energy-intensive facilities, leaving much of the market without cost effective access and incentives for these solutions. In addition, with increasingly stringent energy codes, cost effective component-based solutions that achieve significant savings are dwindling. Integrated building systems (e.g., integrated façade, HVAC and/or lighting solutions) can deliver higher savings (Regnier et al. 2017) that translate into large sector-wide savings if deployed at the scale of these programs. However, systems application poses a number of challenges – energy savings assessments are inherently more complex and are not easily suited to the deemed measure model, and implementation of systems can be more disruptive. This paper presents the outcomes of a project to develop validated utility incentive program packages for three specific integrated building systems, in collaboration with ComEd, a consortium of California Public Owned Utilities (CA POUs) (Northern California Power Agency(NCPA) and the Southern California Public Power Authority(SCPPA)), and Xcel Energy (CO, MN). Previous work described the potential for energy savings of these systems at the individual and market level, early test findings for the task-ambient lighting system, and described the work products to develop utility incentive programs (Regnier et al. 2016). This paper presents validated end use energy savings of all three systems showing energy savings of ~20% for automated shading combined with daylight dimming (does not include light fixture retrofit savings); 30-46% for task-ambient lighting systems combined with plug load occupancy controls, depending on technology package and office building size (no daylight dimming impacts); and ~94% in the south-façade daylit zone for workstation specific lighting systems with daylight dimming (including lighting retrofit and task tuning). Using a U.S. Department of Energy (DOE) reference building model (DOE 2018), this translates to whole building savings of 2-5% (large-medium commercial), 12-23% (large-small commercial), and 13-15% (medium-large commercial) for these systems respectively. Early findings from the utilities in deploying these systems through their incentive programs indicate that deployment methods such as direct install programs might be best suited for these integrated systems. Further, early findings from a scoping study across custom utility programs and federal retrofit programs indicate that component level retrofits are still prevalent even in these programs, pointing towards an opportunity for deeper energy savings deployment. High performance retrofit case studies demonstrate that deeper energy savings is possible through integrated approaches. Market stakeholder interviews indicate however that there is generally a low level of awareness of the potential for energy savings of these three integrated systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of the Thermal and Moisture Performance of Insulating Shades

Heat transfer through windows accounts for a significant percentage of a building’s energy use and adds substantially to the peak heating and cooling loads of a home. Over the past 20 years, residential window attachment retrofit technologies have been developed that significantly increase the number of options available to home builders, homeowners, and utilities when considering upgrades of overall window performance. Within the interior window attachments category, honeycomb cellular shades typically have the highest R-values because of their layered or concentric designs. During the winter when the window is fully covered, however, the added insulation reduces the amount of warm indoor air that reaches the window surface, thereby lowering the temperature of the window glass and frame and increasing the potential for condensation to collect on the interior surface of the window. The degree to which this potential is realized depends on the indoor and outdoor conditions as well as the overall thermal resistance of the window and the shades. To examine the condensation buildup potential on the interior surface of the window and the conditions under which this occurs, this report describes experimental research conducted by Pacific Northwest National Laboratory in collaboration with Hunter Douglas, using a a controlled environmental test chamber at the Hunter Douglas facility in Broomfield, Colorado. The results will be used to inform the Attachments Energy Rating Council, which provides energy performance information on all rated window attachments products.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Greenbuilt Construction Energy Efficiency Retrofit House Demonstration - Sacramento

One of the homes that was part of Sacramento Municipal Utility District's (SMUD) Energy Efficiency Retrofit Demonstration (EERD) project was a 1980's era home in Fair Oaks, California, referred to as the Greenbuilt house, as Greenbuilt Construction completed the retrofit of the home. The home underwent an extensive energy efficiency retrofit with a goal of achieving a 50% reduction in energy use to demonstrate the potential for other builders and homeowners in the area. The retrofit measures included installing: ENERGY STAR appliances high efficiency light roof radiant barrier additional ceiling and wall insulation double-pane, low-e windows external motorized shading and solar tubes a 16 SEER/9.75 HSPF heat pump improved ducts a whole-house fan a heat pump water heater (HPWH) integrated collector storage solar water heater (ICS SWH) and 3.2 kW of PV. In addition, the home was air sealed to reduce infiltration. Researchers from the National Renewable Energy Laboratory (NREL) performed short-term tests on the major systems installed as part of the retrofit to ensure that they were performing as expected. The systems evaluated included the space conditioning heat pump, the air handler and ducts, the HPWH, the ICS SWH, and the PV array. Some ducts were untwisted after testing revealed that two rooms were not getting sufficient airflow. Afterwards, all systems were performing as expected. In addition to testing to confirm adequate performance of all new systems, NREL was given the opportunity to use the Greenbuilt house as a laboratory house for a year. The space conditioning system and home water systems were subjected to a series of tests to determine optimal control strategies for lowering energy consumption and reducing peak (4:00-7:00 p.m.) energy consumption during the summer. The different cooling strategies considered included two different precooling schedules, drawing the external shades during the day and using the whole-house fan at night, and combinations of those. The most effective strategy for reducing overall energy consumption was the use of external shades, which cut the daily cooling load by 34% and reduced the energy use during peak hours by 40%. The different precooling strategies eliminated the peak load entirely but actually increased daily cooling energy use. The use of shades and the advanced precooling strategy increased the daily energy use by 5% but eliminated all peak use and maintained a comfortable home. These results were verified over the entire summer using an Energy Plus model of the home. The hot water system was tested in two configurations: the HPWH alone and the ICS solar water heater paired with the HPWH. Six hot water draw profiles, varying in terms of daily hot water volume, time of day for hot water use, and the duration of the draws, were imposed on the hot water system to test their effects on performance. When operating alone in the summer, the HPWH operated with a COP around 2.2, except for a draw that used a quarter of the averaged daily hot water usage, which had an average COP of 1.6. The combination of ICS and HPWH resulted in larger COPs, but also more variability depending on the draw profile. The standard, hourly draw profile produced the highest COP of 6.4. The quarter volume draw profile had the lowest COP of 2.8 for the combined system. Relative to a standard electric water heater, the HPWH operating alone reduced the peak load by 56% and the combined ICS and HPWH system completely eliminated the peak load.

air sealing↗

Topographic mapping of the moon

Contour maps of the moon have been compiled by photogrammetric methods that use stereoscopic combinations of all available metric photographs from the Apollo 15, 16, and 17 missions. The maps utilize the same format as the existing NASA shaded-relief Lunar Planning Charts (LOC-1, -2, -3, and -4), which have a scale of 1:2,750,000. The map contour interval is 500 m. A control net derived from Apollo photographs by Doyle and others was used for the compilation. Contour lines and elevations are referred to the new topographic datum of the moon, which is defined in terms of spherical harmonics from the lunar gravity field. Compilation of all four LOC charts was completed on analytical plotters from 566 stereo models of Apollo metric photographs that cover approximately 20 percent of the moon. This is the first step toward compiling a global topographic map of the moon at a scale of 1:5,000,000.

Wu, S. S. C.↗

Improving Land-Surface Modeling of Evapotranspiration Processes in Tropical Forests (Final Report)

Land surface models are used to represent terrestrial processes that shape global climate; examples of these processes include evaporation, plant water use, and photosynthesis. While much progress has been made to improve and refine these models, some hydrological processes are not well captured, which hinders our ability to understand land-atmosphere interactions and ultimately to predict impacts of climate change on water resources. The inadequate representation of evapotranspiration may partly explain why global climate models do not match observed precipitation patterns. Multiple factors contribute to this problem. In moist tropical regions, high humidity, leaf wetness, and cloud cover combine to suppress forest water use and possibly reduce forest growth in ways that are poorly understood. Mountainous areas pose additional difficulties, as standard modeling and measurement techniques are not readily applied in rough terrain. In this project, we aimed to improve our understanding and modeling of fluxes of water vapor and carbon dioxide to and from tropical forests. To do this, we collected a suite of data from the mountainous rainforest surrounding the Texas A&M Soltis Center in San Ramon, Costa Rica. From 2014 to 2018, a suite of variables were measured, including: in-canopy profiles of water vapor, carbon dioxide, temperature, light, and leaf wetness; transpiration, evapotranspiration, carbon flux, and soil respiration; and local weather conditions. Leaf-scale measurements were used to find photosynthesis rates and derive their parameters. Using this data set, we were able to better quantify the relationships between assimilation and transpiration and their main drivers in tropical forests. These variables were namely available light, vapor pressure deficit, and leaf wetness, but not soil moisture, which exerted no detectable control. We also showed the vertical variability in canopy microclimates and how neglecting forest layers in models may misrepresent overall fluxes. The data were then used to test and refine evapotranspiration and energy budget formulations in the Community Land Model. Fluxes and energy budget components were compared to simulated values from CLM4.5 and CLM.5. The biggest discrepancies arose from hillslope shading effects, particularly mismatches in afternoon carbon fluxes, with notable differences in transpiration rates and sap flux due to capacitance in large trees. Secondary, but still significant issues included unrealistic leaf wetness and leaf drying rates, as well as air and vegetation temperatures, both of which were likely linked to CLM’s formulations controlling wet leaf and sunlit/shaded leaf fractions. Modeling multiple layers in the canopy via the newly released CLM-ml and making adjustments to existing parameters both show promise in resolving these issues. In total, the project has produced 5 peer-reviewed articles, 24 presentations, 2 theses, 4 public outreach items, and 4 publically available datasets, to date. Additional products are expected pending the completion of an additional thesis. Data has also been shared with several collaborative networks, including PHENOCAM and SAPFLUXNET.

54 ENVIRONMENTAL SCIENCES↗

Angular selective window systems: Assessment of technical potential for energy savings

Static angular selective shading systems block direct sunlight and admit daylight within a specific range of incident solar angles. The objective of this study is to quantify their potential to reduce energy use and peak demand in commercial buildings using state-of-the art whole-building computer simulation software that allows accurate modeling of the behavior of optically-complex fenestration systems such as angular selective systems. Three commercial systems were evaluated: a micro-perforated screen, a tubular shading structure, and an expanded metal mesh. This evaluation was performed through computer simulation for multiple climates (Chicago, Illinois and Houston, Texas), window-to-wall ratios (0.15-0.60), building codes (ASHRAE 90.1-2004 and 2010) and lighting control configurations (with and without). The modeling of the optical complexity of the systems took advantage of the development of state-of-the-art versions of the EnergyPlus, Radiance and Window simulation tools. Results show significant reductions in perimeter zone energy use; the best system reached 28% and 47% savings, respectively without and with daylighting controls (ASHRAE 90.1-2004, south facade, Chicago,WWR=0.45). As a result, angular selectivity and thermal conductance of the angle-selective layer, as well as spectral selectivity of low-emissivity coatings, were identified as factors with significant impact on performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Temperature Controller for a Solar Furnace

Relatively-simple movable sheild has been suggested for controlling temperature of solar furnace. Temperature modulator can be set to have collected solar energy fully "on", fully "off" or any intermediate level. Parabolic mirror concentrates Sunlight into receiver. Shade plate that blocks insolation at back of receiver produces shade zone in center of collector. No radiation is returned to receiver from shade zone; only rays falling on other areas of reflecting surface are directed back toward receiver.

Hale, R. R.↗

Preheating temperature effect on tritium retention in VPS-W

The W coating by Vacuum Plasma Spraying (VPS) technology is thought to be reasonable for most plasma facing components in future fusion reactors. In this paper the deuterium retention behavior for the Vacuum Plasma Spraying (VPS) tungsten (W) coating has been studied to demonstrate the tritium retention as a function of heating temperature. It has been found that two major deuterium desorption stages were observed at the temperature regions of 400 - 700 K (Stage 1) and 900 - 1100 K (Stage 2), considering that Stage 1 has been linked to the desorption of deuterium trapped by near surface and intrinsic defects, and Stage 2 has been related to the desorption of deuterium bound to impurities as C-D bonds. By heating the sample above 673 K, the major peak of C-1s shifted from C-O bond to C-C bond, where the retention of deuterium as Stage 2 has increased. Therefore it indicates that the hydrogen isotope retention was controlled by the amount of C-C bond in VPS, most of which was contaminated during the VPS coating process. The comparison of several samples (VPS-W with shading, VPS-W without shading and Polycrystalline W (PCW)) shows that the carbon impurity has a large affinity with deuterium and makes stable trapping states compared to that with intrinsic defects and grain boundaries. However, most of them was reduced by heating at 1173 K. Therefore, heating treatment is quite important to get rid of carbon impurities and refrain higher tritium retention in VPS. (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Restoring a Disappearing Ecosystem: the Longleaf Pine Savanna

Longleaf pine (Pinus palustris) savannas of the southeastern United States contain some of the worlds most diverse plant communities, along with a unique complement of wildlife. Their traditionally open canopy structure and rich understory of grasses and herbs were critical to their vigor. However, a long history of land-use practices such as logging, farming, and fire exclusion have reduced this once-widespread ecosystem to only 3 percent of its original range. At six longleaf pine plantations in South Carolina, Tim Harrington with the Pacific Northwest Research Station and collaborators with the Southern Research Station used various treatments (including prescribed burns, tree thinning, and herbicide applications) to alter the forest structure and tracked how successful each one was in advancing savanna restoration over a 14-year period. They found that typical planting densities for wood production in plantations create dense understory shade that excludes many native herbaceous species important to savannas and associated wildlife. The scientists found that although tree thinning alone did not result in sustained gains, a combination of controlled burning, thinning, and herbicide treatments to reduce woody plants was an effective strategy for recovering the savanna ecosystem. The scientists also found that these efforts must be repeated periodically for enduring benefits.

60 APPLIED LIFE SCIENCES↗

Effects on Training Using Illumination in Virtual Environments

Camera based tasks are commonly performed during orbital operations, and orbital lighting conditions, such as high contrast shadowing and glare, are a factor in performance. Computer based training using virtual environments is a common tool used to make and keep CTW members proficient. If computer based training included some of these harsh lighting conditions, would the crew increase their proficiency? The project goal was to determine whether computer based training increases proficiency if one trains for a camera based task using computer generated virtual environments with enhanced lighting conditions such as shadows and glare rather than color shaded computer images normally used in simulators. Previous experiments were conducted using a two degree of freedom docking system. Test subjects had to align a boresight camera using a hand controller with one axis of rotation and one axis of rotation. Two sets of subjects were trained on two computer simulations using computer generated virtual environments, one with lighting, and one without. Results revealed that when subjects were constrained by time and accuracy, those who trained with simulated lighting conditions performed significantly better than those who did not. To reinforce these results for speed and accuracy, the task complexity was increased.

Maida, James C.↗

Multispectral signatures in relation to ground control signature using nested sampling approach

The author has identified the following significant results. Principal effort has been on the development of a PDP-10 software package to read the CCT tapes more cheaply and rapidly. This is 90% completed and debugged. A shade print example of Treasure Island is provided. Stanford area was overflown with the U-2 as an add-on photographic mission to help fill in record-gaps in ERTS-1 overpass which was clouded out.

Lyon, R. J. P.↗

High-shade dryland agrivoltaic conditions enhanced carbon uptake and water-use efficiency in zucchini ( Cucurbita pepo )

Introduction: The increasing global demand for food and energy is intensifying land-use competition. Agrivoltaic systems are a multifunctional land-use approach that vertically integrates the production of agricultural crops and solar power on the same land area. Most food crops are adapted to full-sun conditions, and the physiological responses of these crops to the novel microclimate under solar panels remain poorly understood. We hypothesized that the microclimate beneath the high-density photovoltaic system would influence carbon uptake, water use, and yield outcomes of zucchini summer squash.Methods: We conducted a field experiment in a hot, semi-arid climate on zucchini (Cucurbita pepo). Plants were grown under an agrivoltaic system with a 75% ground cover ratio (GCR) and in a full-sun control plot, each with two irrigation regimes (100 and 50%). We measured leaf-level photosynthesis, microclimate variables, and fruit yield at plant maturity and throughout the growing season.Results: The agrivoltaic array reduced photosynthetically active radiation (PAR) by ~79%, resulting in a cooler (−1.1 °C), more humid environment with higher soil moisture. These microclimatic conditions enhanced midday photosynthesis and daily cumulative carbon uptake. However, fruit yield was consistently lower under the panels, indicating a shift in carbon allocation toward vegetative growth. Photosynthesis was primarily driven by PAR across treatments, while soil moisture significantly influenced photosynthesis only in the control plots, suggesting water limitation was alleviated under the panels.Discussion: These findings highlight a trade-off between improved physiological performance and reduced yield under high-density agrivoltaics. While the system buffered heat and drought stress and improved overall plant function, excessive shade reduced reproductive output. Optimizing panel density or selecting crops cultivated for non-fruit yields will be essential for balancing food production and energy generation in dryland agrivoltaic settings.

14 SOLAR ENERGY↗