Search NASA⌕ Search

SEARCH · Search NASA

Results for “Shape optimization under uncertainty”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

123 records · Page 7

Final Report: Optimal Model Complexity in Geological Carbon Sequestration: A Response Surface Uncertainty Analysis

The critical component of a risk assessment study in evaluating GCS is an analysis of uncertainty in CO2 modeling. In such analyses, direct numerical simulation of CO2 flow and leakage requires many time-consuming model runs. Alternatively, analytical methods have been developed which allow fast and efficient estimation of CO2 storage and leakage, although restrictive assumptions on formation rock and fluid properties are employed. In this study, an intermediate approach is proposed based on the Design of Experiment and Response Surface methodology, which consists of using a limited number of numerical simulations to estimate a prediction outcome as a combination of the most influential uncertain site properties. The methodology can be implemented within a Monte Carlo framework to efficiently assess parameter and prediction uncertainty while honoring the accuracy of numerical simulations. The choice of the uncertain properties is flexible and can include geologic parameters that influence reservoir heterogeneity, engineering parameters that influence gas trapping and migration, and reactive parameters that influence the extent of fluid/rock reactions. The method was tested and verified on modeling long-term CO2 flow, non-isothermal heat transport, and CO2 dissolution storage by coupling two-phase flow with explicit miscibility calculation using an accurate equation of state that gives rise to convective mixing of formation brine variably saturated with CO2. All simulations were performed using three-dimensional high-resolution models including a target deep saline aquifer, overlying caprock, and a shallow aquifer. To evaluate the uncertainty in representing reservoir permeability, sediment hierarchy of a heterogeneous digital stratigraphy was mapped to create multiple irregularly shape stratigraphic models of decreasing geologic resolutions: heterogeneous (reference), lithofacies, depositional environment, and a (homogeneous) geologic formation. To ensure model equivalency, all the stratigraphic models were successfully upscaled from the reference heterogeneous model for bulk flow and transport predictions (Zhang & Zhang, 2015). GCS simulation was then simulated with all models, yielding insights into the level of parameterization complexity that is needed for the accurate simulation of reservoir pore pressure, CO2 storage, leakage, footprint, and dissolution over both short (i.e., injection) and longer (monitoring) time scales. Important uncertainty parameters that impact these key performance metrics were identified for the stratigraphic models as well as for the heterogeneous model, leading to the development of reduced/simplified models at lower characterization cost that can be used for the reservoir uncertainty analysis. All the CO2 modeling was conducted using PFLOTRAN – a massively parallel, multiphase, multi-component, and reactive transport simulator developed by a multi-laboratory DOE/SciDAC (Scientific Discovery through Advanced Computing) project (Zhang et al., 2017, in review). Within the uncertainty analysis framework, increasing reservoir depth were investigated to explore its effect on the uncertainty outcomes and the potential for developing gravity-stable injection with increased storage security (Dai et al., 20126; Dai et al., 2017, in review). Finally, to accurately model CO2 fluid-rock reactions and resulting long-term storage as secondary carbonate minerals, a modified kinetic rate law for general mineral dissolution and precipitation was proposed and verified that is invariant to a scale transformation of the mineral formula weight. This new formulation will lead to more accurate assessment of mineral storage over geologic time scales (Lichtner, 2016).

58 GEOSCIENCES↗

Prediction of DIII-D Pedestal Structure from Externally Controllable Parameters

The sharp increase of pressure at the edge of a high confinement mode (H-mode) plasma, the pedestal, strongly impacts overall plasma performance. Predicting the pedestal is a necessity to control and optimize tokamak operations. An experimental data-driven machine learning (ML) approach is presented that predicts the pedestal heights and widths of electron density (ne) and electron temperature (Te) profiles as well as the separatrix ne from externally controllable parameters such as the plasma shape, heating method and power, and gas puff rate and integrated gas puff. The OMFIT framework was used with DIII-D data to efficiently, robustly, and automatically build a database of pedestal parameters to train machine learning models. Database creation was enabled by the search engine tool for DIII-D data, TokSearch, which parallelizes data fetching, enabling fast searches through basic signals of thousands of DIII-D shots and selection of relevant time intervals. Principal Component Analysis (PCA) separated the database into three clusters that represent classes of plasma shapes that are regularly used in DIII-D. The most important parameters for setting the pedestal structure were plasma current (Ip), toroidal magnetic field (Bφ), neutral beam heating power (PNBI) and shaping quantities. The Deep Jointly Informed Neural Networks (DJINN) algorithm was applied to identify suitable neural network (NN) architectures that appropriately capture the features of the pedestal database. Separate NNs were implemented for each pedestal parameter, and ensembling methods were used to improve the prediction accuracy and allowed estimation of the prediction uncertainty. The pedestal predictions of the test dataset lie within the measurement uncertainties of the pedestal parameters. The NN outperformed simple Linear Regression (LR) analysis, indicating non-linear dependencies in the pedestal structure. The presented achievements illustrate a promising path for future research, using feature extraction to infer experimental trends and thereby improve pedestal models as well as deploying NN for a fast pedestal prediction in DIII-D scenario development.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Prediction of DIII-D Pedestal Structure From Externally Controllable Parameters

The sharp increase of pressure at the edge of a high confinement mode (H-mode) plasma, the pedestal, strongly impacts overall plasma performance. Predicting the pedestal is a necessity to control and optimize tokamak operations. Here, an experimental data-driven machine learning (ML) approach is presented that predicts the pedestal heights and widths of electron density (n e ) and electron temperature (T e ) profiles as well as the separatrix ne from externally controllable parameters such as the plasma shape, heating method and power, and gas puff rate and integrated gas puff. The OMFIT framework was used with DIII-D data to efficiently, robustly, and automatically build a database of pedestal parameters to train machine learning models. Database creation was enabled by the search engine tool for DIII-D data, TokSearch, which parallelizes data fetching, enabling fast searches through basic signals of thousands of DIII-D shots and selection of relevant time intervals. Principal Component Analysis (PCA) separated the database into three clusters that represent classes of plasma shapes that are regularly used in DIII-D. The most important parameters for setting the pedestal structure were plasma current (I p ), toroidal magnetic field (B Φ ), neutral beam heating power (P NBI ) and shaping quantities. The Deep Jointly Informed Neural Networks (DJINN) algorithm was applied to identify suitable neural network (NN) architectures that appropriately capture the features of the pedestal database. Separate NNs were implemented for each pedestal parameter, and ensembling methods were used to improve the prediction accuracy and allowed estimation of the prediction uncertainty. The pedestal predictions of the test dataset lie within the measurement uncertainties of the pedestal parameters. The NN outperformed simple Linear Regression (LR) analysis, indicating non-linear dependencies in the pedestal structure. The presented achievements illustrate a promising path for future research, using feature extraction to infer experimental trends and thereby improve pedestal models as well as deploying NN for a fast pedestal prediction in DIII-D scenario development.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantification of LEU Holdup using gamma ray imaging and inverse transport solver

Holdup is the residual amount of special nuclear material (SNM) remaining in a processing facility after the bulk materials have been cleaned out. In commercial uranium processing facilities, quantification of holdup is a major challenge because of the highly variable shapes and sizes of the deposits. Any method that attempts to generalize and calibrate deposit shapes in order to quantify holdup will be prone to high uncertainties. Uncertainties on the order of ±50% are typical in holdup results. In international safeguards applications, a ±50% uncertainty can result in a large amount of material unaccounted for (MUF) thereby increasing the difficulty of detecting material diversion and facility misuse. An imaging-based methodology has been developed with the objective of significantly reducing this uncertainty by using the true deposit shape, instead of relying on oversimplified geometric assumptions. The project is a collaboration between ORNL, Y-12, and the University of Tennessee, Knoxville, TN. Uranium sources of known masses were measured using the Germanium Gamma-ray Imager (GeGI), a high-resolution imaging spectrometer, creating a pixelated map for each spectral bin. Two different gamma imaging methods are employed in this work: coded aperture imaging and Compton imaging. A validated MonteCarlo model of the detector has been developed using the GEANT4 code for determining the intrinsic response of the detector, its enclosure, and the coded aperture mask. An inverse transport solver based on the Markov Chain Monte-Carlo approach known as Differential Evolution Adaptive Metropolis (DREAM) is employed to use the measurement data from the image pixels (coded aperture or Compton) to solve for the mass of 235 U in the deposit. A reliable method based on the DREAM solver has been developed to flag the infinite thickness condition of a uranium deposit. The project team is working towards improving the image reconstruction for Compton imaging so that a better localization of the source can be achieved. Besides treating the coded aperture and Compton imaging methods independently, the project is also evaluating a combined method that uses the Compton scatter data from a coded aperture measurement. GEANT4 simulations are being performed to evaluate the combined approach. The impact on the DREAM optimization as the source thickness progressively approaches infinite thickness is being evaluated. A number of uranium sources available at ORNL have been measured, and the DREAM results have been tested and validated for the coded aperture imaging. A similar effort will be carried out to validate the Compton based method once the development of algorithms for better localization are complete. The imaging based quantification is very amenable to unattended monitoring of holdup accumulation at key measurement points. A proof of concept measurement has been completed to demonstrate this capability The current work used the high energy resolution imager GeGI. However, the approach and methodologies are applicable to other imagers such as the cadmium zin telluride (CZT) based imager manufactured by H3D, Inc.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Optimization of Kaplan Hydroturbine at Very Low Head With Rim-Driven Generator

The objective of the paper is to study the design and optimization of Kaplan hydroturbines for a very low head (less than 3 m), with a particular emphasis on the use of rim-drive electrical generators. The work is based on an experimental setup and computational fluid dynamics (CFD) analysis of various design parameters for maximum output power and efficiency. Two designs are presented in this paper. One is a 90-cm (35-in.) diameter vertical-oriented Kaplan hydroturbine system as an intended product capable of generating over 50 kW. The other is a smaller, 7.6-cm (3-in.) diameter horizontal-oriented system for prototyping and laboratory verification. Both are analyzed through CFD based on large eddy simulation (LES) of transient turbulence. Specific design for the runner and the stator, intake tube shape, as well as guide vanes upstream of the turbine was studied to get the most from the available head. The intent is to use 3D-printing manufacturing techniques, which may offer original design opportunities as well as the possibility of turbine and water conduit design customization as a function of the head and flow available from a specific site. Based on the CFD analysis, the 7.6-cm diameter system achieved the highest power output and the maximum efficiency at the rotational speed range of 1500–2000 rpm, while for the experimental testing, the optimum rotational speed range was 1000–1500 rpm. Because of the mismatch between CFD and experimental results, the CFD results were correlated due to the presence of air and friction; moreover, error and uncertainty analysis were presented for both methods. For the 90-cm case, the optimum performance was found at a rotational speed around 350 rpm according to the CFD results. Finally, investigating the shape of the intake tube of the hydroturbine setup can significantly increase the power output and the efficiency of the system.

Energy & Fuels↗

Parameterization retrieval of trace gas volume mixing ratios from Airborne MAX-DOAS

We present a parameterization retrieval of volume mixing ratios (VMRs) from differential slant column density (dSCD) measurements by Airborne Multi-AXis Differential Optical Absorption Spectroscopy (AMAX-DOAS). The method makes use of the fact that horizontally recorded limb spectra (elevation angle 0°) are strongly sensitive to the atmospheric layer at instrument altitude. These limb spectra are analyzed using reference spectra that largely cancel out column contributions from above and below the instrument, so that the resulting limb dSCDs, i.e., the column integrated concentration with respect to a reference spectrum, are almost exclusively sensitive to the atmospheric layers around instrument altitude. The conversion of limb dSCDs into VMRs is then realized by calculating box air mass factors (Box-AMFs) for a Rayleigh atmosphere and applying a scaling factor constrained by O 4 dSCDs to account for aerosol extinction. An iterative VMR retrieval scheme corrects for trace gas profile shape effects. Benefits of this method are (1) a fast conversion that only requires the computation of Box-AMFs in a Rayleigh atmosphere; (2) neither local aerosol extinction nor the slant column density in the DOAS reference (SCD ref ) needs to be known; and (3) VMRs can be retrieved for every measurement point along a flight track, thus increasing statistics and adding flexibility to capture concentration gradients. Sensitivity studies are performed for bromine monoxide (BrO), iodine monoxide (IO) and nitrogen dioxide (NO 2 ), using (1) simulated dSCD data for different trace gas and aerosol profiles and (2) field measurements from the Tropical Ocean tRoposphere Exchange of Reactive halogen species and Oxygenated VOC (TORERO) field experiment. For simulated data in a Rayleigh atmosphere, the agreement between the VMR from the parameterization method (VMR para ) and the true VMR (VMR true ) is excellent for all trace gases. Offsets, slopes and R 2 values for the linear fit of VMR para over VMR true are, respectively (0.008 ± 0.001) pptv, 0.988 ± 0.001, 0.987 for BrO; (-0.0066 ± 0.0001) pptv, 1.0021 ± 0.0003, 0.9979 for IO; (-0.17 ± 0.03) pptv, 1.0036 ± 0.0001, 0.9997 for NO 2 . The agreement for atmospheres with aerosol shows comparable R 2 values to the Rayleigh case, but slopes deviate a bit more from one: (0.093 ± 0.002) pptv, 0.933 ± 0.002, 0.907 for BrO; (0.0021 ± 0.0004) pptv, 0.887 ± 0.001, 0.973 for IO; (8.5 ± 0.1) pptv, 0.8302 ± 0.0006, 0.9923 for NO 2 . VMR para from field data are further compared with optimal estimation retrievals (VMR OE ). Least orthogonal distance fit of the data give the following equations: BrO para = (0.1 ± 0.2) pptv + (0.95 ± 0.14) × BrO OE ; IO para = (0.01 ± 0.02) pptv + (1.00 ± 0.12) × IO OE ; NO 2para = (3.9 ± 2.5) pptv + (0.87 ± 0.15) × NO 2OE . Overall, we conclude that the parameterization retrieval is accurate with an uncertainty of 20 % for IO, 30 % for BrO and NO 2 , but not better than 0.05 pptv IO, 0.5 pptv BrO and 10 pptv NO 2 . Finally, the retrieval is applicable over a wide range of atmospheric conditions and measurement geometries and not limited to the interpretation of vertical profile measurements in the remote troposphere.

54 ENVIRONMENTAL SCIENCES↗

Isotherm Modeling and Techno-Economic Analysis of Contactor Technologies for New Tetraamine-Appended MOF for NGCC Applications

Recently, a family of tetraamine-functionalized metal-organic frameworks (MOF) has been reported as promising sorbent materials for capturing CO2 from flue gas conditions relevant to natural gas combined cycle (NGCC) applications. The main advantages of these materials are their two-step cooperative CO2 adsorption, which gives rise to unusual two step-shaped CO2 adsorption profiles and their high thermal stability. This work presents the modelling of the two-transition isotherm of the tetraamine-appended MOF, N,N'-bis(3-aminopropyl)-1,4-diaminobutane (3-4-3)-appended Mg2(dobpdc), and the techno-economic analysis (TEA) of carbon capture processes utilizing this sorbent. Due to the unusual isotherm shapes of the experimental CO2 adsorption data for tetraamine-appended Mg2(dobpdc) and the strong nonlinearity of CO2 loading with respect to temperature and pressure, we tested two different models which use logistic functions for representing the different isotherm behaviors in the different pressure ranges. The first model uses the quadratic isotherm model in the low-pressure region, the Langmuir isotherm model in the middle pressure range, and the dual site Langmuir isotherm model in the high-pressure range. To model the transition between regions we used the arctangent functions independent of temperature and the thermal effect was accounted by using the Clausius-Clapeyron relation]. The second model is an extension of the weighted dual-site Langmuir isotherm model presented by Hughes et al.. In this extended model, the dual-site Langmuir isotherm is employed in the three transition regions, using temperature-dependent logistic functions to activate or deactivate the isotherm model in the low, middle, and high-pressure ranges. Both models fit the experimental data quite well with root mean squared errors (RMSE’s) of 0.41 and 0.17 for model 1 and model 2, respectively. Since model 2 resulted in a lower RMSE, it was leveraged for the development of the gas/solid contactor models used by the TEA. Specifically, two different contactor models, an axial-flow fixed bed and moving bed contactor, were developed as part of this work. These models are dynamic, pressure-driven, and consist of mass, energy, and momentum conservation equations. A kinetic model was also developed by performing parameter estimation using experimental fixed bed breakthrough data. These models are then used to simulate CO2 capture processes from the flue gas generated from a ~600 gross MW NGCC power plant. A cost model was developed which considers the capital cost of the reactors and the significant operating costs such as steam and electricity. Using NETL’s Framework for the Optimization and Quantification of Uncertainty of Uncertainty and Surrogates tool (FOQUS), which has the capability of linking models built using numerous modelling platforms with derivative-free optimization solvers, a techno-economic optimization of the carbon capture processes was performed which minimizes the cost of capture.

Caballero, Daison↗

An updated estimate of the Mu2e experiment sensitivity

The Mu2e experiment at Fermilab will search for the conversion of a negative muon into an electron inside the field of a nucleus. This process does not conserve charged-lepton flavour and is heavily suppressed in the Standard Model (SM), with a branching ratio < 10-50. Any evidence of it would be an undeniable evidence of new physics beyond the SM. The project sets out to achieve a single event sensitivity of $\sim 3 × 10^{-17}$ on the ratio between the probability for a conversion of a negative muon into an electron and the one for a muon capture by the nucleus. Such a sensitivity would represent a 4 orders of magnitude improvement on the previous upper limit for the process, making possible to test predictions of different extensions of the SM. Mu2e uses three superconducting solenoids to produce and measure the muon conversions. In the first solenoid, the Production Solenoid, pions and kaons are produced, together with other secondary products, by 8 GeV kinetic energy proton interactions in a tungsten target. A gradient magnetic field is specifically designed to direct low momentum particles into the Transport Solenoid, an S-shaped magnet that filters out particles with unwanted charge and momentum. Muons, produced by pion and kaon decays, finally reach the aluminum Stopping Target in the Detector Solenoid, where they eventually stop and convert. The result of the conversion process is a monochromatic electron of ~105 MeV/c momentum. The Detector Solenoid also hosts the two main detectors: a straw tube tracker and two CsI calorimeter disks, both providing measurement of event kinematics. A germanium detector and a LaBr crystal are located downstream of the Detector Solenoid to measure the X and gamma rays produced by the muon captures in the Stopping Target. A veto system of scintillators covering the Detector Solenoid and half of the Transport Solenoid is used to identify and reject cosmic rays interactions. With respect to the initial project, the Mu2e running plan has evolved to a staged configuration with 2 years at reduced intensity before the 2025 accelerator shutdown for the neutrino beam upgrade and 2 or 3 years at full intensity after that. This, together with geometry changes and a better knowledge of detector performances obtained by the first slice tests, has required a full revision of the signal over background selection that is the subject of this thesis. In order to achieve a new estimate of Mu2e sensitivity, the simulation of the data corresponding to the first 2 years of data acquisition has been performed. This includes both conversion electrons (CE) and the main sources of background: cosmics, decay-in orbits (DIO), radiative pion captures (RPC) and antiprotons. The characteristics of the signal and of the main backgrounds have been studied to define the best selection variables for CE. A special effort has been devoted to the evaluation of the antiproton background. The lack of experimental data for antiproton production cross section makes the systematic uncertainty on this background significant. A new parameterization of the cross section has been developed to fit the existing data and to provide a more reliable estimate of the systematic uncertainty by comparing the results of the old and the new model. A special effort has been devoted to the optimization of the antiprotons Monte Carlo generator. This study has also revealed that the dominant component within this background is represented by antiprotons produced in the opposite direction with respect to the Transport Solenoid entrance and then redirected to it by back-scattering processes in the Production Target. This ultimately highlights the sensitivity of the background estimate to the G4 handling of antiproton interactions in the 1 to 3 GeV/c momentum range. Finally, the final experimental sensitivity has been studied. The momentum and time selection have been optimized to obtain the 5-sigma discovery reach or, in case of no signal, the upper limit on conversion probability. The results confirm that, in the firs t two years of data taking, Mu2e will be able to improve the current experimental sensitivity for muon-to-electron conversion in an atomic field by more than 3 order of magnitudes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ATF Transient Prescription Tests in TREAT

EXECUTIVE SUMMARY The Transient Reactor Test facility (TREAT) was constructed in the late 1950’s and provided thousands of transient irradiations before being placed in standby mode in 1994. In 2017, it resumed operation in order to reclaim its crucial role in nuclear-heated safety research. TREAT is a transient reactor where inherently-safe core physics, a nimble transient rod drive system, and a philosophy of continual facility improvement work together to enable flexible power maneuvers for fuel safety research. While the facility’s flexible design and multi-mission nature saw historic experiments for numerous transient types, TREAT was not specifically adapted to optimize or demonstrate its full performance capability for Light Water Reactor (LWR) postulated accidents including Hot Zero Power Reactivity Initiated Accidents (HZP-RIA) and Loss of Coolant Accidents (LOCA). The physics of HZP-RIA drive very brief pulses with fairly large energy excursions. TREAT is currently capable of approaching HZP-RIA pulse widths through transients initiated on a large step insertion of reactivity and terminated shortly thereafter by rapid re-insertion of the transient rods (“clipping”). LOCAs are postulated to occur quite differently, starting from normal power operations followed by a long period of lower power decay heat. TREAT is able to simulate LOCA events with an initial flattop transient for tens of seconds, followed by a sizeable power reduction, to a longer segment where specimen fission heating represents internal decay heat generation. Two reactor physics testing campaigns were undertaken to address the HZP-RIA type transients, neither of which had been performed in any great measure historically to address data gaps in the timing, repeatability of clipping and effect of dynamic transient rod motions on core-to-specimen fission power coupling. The first campaign, referred to as the Accident Tolerant Fuel (ATF) transient prescription tests, employed dosimeters in the core to characterize the effect of rod motions on specimen power coupling for clipped, unclipped, and low-level steady state operations each with approximately the same moderate core energy release. This campaign was accompanied by efforts to measure dosimetry and compare results to analytic predictions. The other HZP-RIA campaign, referred to as Narrow Pulse Width (NPW) transient prescriptions, employed higher step insertions with increased core energy release to demonstrate TREAT’s capability in achieving the narrowest-possible pulse width. Additionally, a series of LOCA transient prescriptions were also performed to demonstrate how well TREAT could perform long-duration shaped transients. Both NPW and LOCA transient prescriptions did not include dosimeters but used existing plant power instrumentation to produce transient power data. All three transient prescription campaigns were successfully carried out in TREAT. The ATF-3 transient prescriptions showed that TREAT can perform clipped transients with remarkable repeatability. Measurement and modeling both showed that the power coupling in small, fissile dosimeters does not change by more than 8% between clipped, unclipped, and steady state runs while uncertainty sources in both the modeling and measurement methods were identified and found to be on the order of 20% in total. Overall, the ATF-3 transient prescription tests were successful in determining repeatability and consistency of dosimeter power coupling, developing processes for modeling and measuring this crucial parameter, and demonstrating the need for continued efforts in transient prescription work at TREAT in support of future experiment design and post test data interpretation. The NPW and LOCA transient prescriptions were also successfully performed to exhibit TREAT’s capability for these important LWR accident categories. The NPW transients showed pulse widths of ~90 ms, which were the narrowest ever achieved in TREAT to date and relevant for the upper end range of HZP-RIA simulation. This effort provided crucial data for calibrating kinetic models to be used in enhanced pulse-narrowing strategies in upcoming irradiations. Similarly, The LOCA transient prescriptions showed that TREAT can simulate the needed nuclear heating and event time scales for LOCA fuel safety research and provided essential data for future experiment design.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Investigating the limits of PET/CT imaging at very low true count rates and high random fractions in ion-beam therapy monitoring

Purpose: External beam radiotherapy with protons and heavier ions enables a tighter conformation of the applied dose to arbitrarily shaped tumor volumes with respect to photons, but is more sensitive to uncertainties in the radiotherapeutic treatment chain. Consequently, an independent verification of the applied treatment is highly desirable. For this purpose, the irradiation-induced β{sup +}-emitter distribution within the patient is detected shortly after irradiation by a commercial full-ring positron emission tomography/x-ray computed tomography (PET/CT) scanner installed next to the treatment rooms at the Heidelberg Ion-Beam Therapy Center (HIT). A major challenge to this approach is posed by the small number of detected coincidences. This contribution aims at characterizing the performance of the used PET/CT device and identifying the best-performing reconstruction algorithm under the particular statistical conditions of PET-based treatment monitoring. Moreover, this study addresses the impact of radiation background from the intrinsically radioactive lutetium-oxyorthosilicate (LSO)-based detectors at low counts. Methods: The authors have acquired 30 subsequent PET scans of a cylindrical phantom emulating a patientlike activity pattern and spanning the entire patient counting regime in terms of true coincidences and random fractions (RFs). Accuracy and precision of activity quantification, image noise, and geometrical fidelity of the scanner have been investigated for various reconstruction algorithms and settings in order to identify a practical, well-suited reconstruction scheme for PET-based treatment verification. Truncated listmode data have been utilized for separating the effects of small true count numbers and high RFs on the reconstructed images. A corresponding simulation study enabled extending the results to an even wider range of counting statistics and to additionally investigate the impact of scatter coincidences. Eventually, the recommended reconstruction scheme has been applied to exemplary postirradiation patient data-sets. Results: Among the investigated reconstruction options, the overall best results in terms of image noise, activity quantification, and accurate geometrical recovery were achieved using the ordered subset expectation maximization reconstruction algorithm with time-of-flight (TOF) and point-spread function (PSF) information. For this algorithm, reasonably accurate (better than 5%) and precise (uncertainty of the mean activity below 10%) imaging can be provided down to 80 000 true coincidences at 96% RF. Image noise and geometrical fidelity are generally improved for fewer iterations. The main limitation for PET-based treatment monitoring has been identified in the small number of true coincidences, rather than the high intrinsic random background. Application of the optimized reconstruction scheme to patient data-sets results in a 25% − 50% reduced image noise at a comparable activity quantification accuracy and an improved geometrical performance with respect to the formerly used reconstruction scheme at HIT, adopted from nuclear medicine applications. Conclusions: Under the poor statistical conditions in PET-based treatment monitoring, improved results can be achieved by considering PSF and TOF information during image reconstruction and by applying less iterations than in conventional nuclear medicine imaging. Geometrical fidelity and image noise are mainly limited by the low number of true coincidences, not the high LSO-related random background. The retrieved results might also impact other emerging PET applications at low counting statistics.

60 APPLIED LIFE SCIENCES↗

Toward a lean analysis for waste to support the decommissioning operation - 15321

All over the world, several nuclear facilities have been shut down few years ago and are now under dismantling or will be dismantled in the future. - Dismantling project takes place according to three major phases: - Study and definition of the dismantling scenario - Dismantling site operations - Decommissioning and final state characterization. Each step is lead in agreement with safety, security and waste management. This requires analytical tools appropriate to the radiological environment and aims. In the field of security, fissile products, explosives... will be researched and quantified while occupational safety requires quantification of radiological, carcinogenic, mutagenic and reprotoxic elements such as As, Se, Cr(IV)... or even asbestos in order to follow more and more strengthened rules. For waste management, radiological and chemical quantification are necessary but must be completed by determining physical and chemical properties such as reactivity, stability or dissolution of the waste... Required level of knowledge, analytical deadline, uncertainties, limits of detection and matrix varieties depend on the decommissioning phase. Setting up a dismantling scenario requires the most possible accurate knowledge of the initial source term present in the facility, in order to establish waste management flow-sheets, define dismantling intervention modes, and prepare the associated safety demonstrations. As history is often not sufficient, in-situ investigations and off-site laboratories are necessary to assign an initial waste and radiological inventory and propose some strategy operations. When a first scenario is chosen, more detailed samplings and analyses are required to fully prepare estimates of waste volumes and categories, and define and validate the waste recovery system that would be used during the dismantling operation. As the definition of the dismantling plan takes shape, data must be more and more accurate and reliable in order to define the waste outlet. The scaling factors for the waste must be defined in order to assure the refunding of the waste. This includes complete characterizations of various matrixes, with high precision, low detection limit in a limited time of few months, as sketchy data could lead to fix inappropriate plan Once site operations begin, it is necessary to control the safety operational conditions and waste production. Measurements requirement is under the safety threshold. Matrixes are often limited to filter. The most important factor is deadline, because operations delay is costly. Finally at the end of dismantling operations, analyses must be performed to demonstrate the successful clean-up of the work site. Analytical methods with low detection limit are required. Thus, characterization appears as a graded and iterative process and is a key issue for decommissioning and dismantling operations in term of efficiency and cost. In order to face this huge analytical demand, a strategy for sampling and characterization must be developed regarding the real needs. On site measurements are usually performed with existing hand-held instruments. A basic first level of knowledge is obtained without delay, feeding the dismantling scenario. On these bases, a sampling strategy permits to select some representative specimens to be more precise, and accurate analysis is performed on off-site laboratories introducing an additional difficulty: the sampling on the site and sub-sampling in the laboratory itself. Whatever the level of sampling, aliquots are small considering the dimension of the dismantling area. This step is crucial. Sampling strategy must be optimized according to objectives (scaling factors measurement, waste level). But in the particular case of high radioactive level waste, due to security manipulation constraints, the number and mass of samples collected are limited. At the opposite for low level waste, large number of samples is collected meaning that large analytical method capacity is necessary. Optimization of the analytical plan is critical. The analytical strategy (including control of sub-sampling, analysis sequence according to analytical capability and performances, especially for pure beta emitters) developed for real case will be detailed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Robust Parameter Design on Dual Stochastic Response Models With Constrained Bayesian Optimization

In engineering system design, minimizing the variations of the quality measurements while guaranteeing their overall quality up to certain levels, namely the robust parameter design (RPD), is crucial. Recent works have dealt with the design of a system whose response-control variables relationship is a deterministic function with a complex shape and function evaluation is expensive. In this work, we propose a Bayesian optimization method for the RPD of stochastic functions. Dual stochastic response models are carefully designed for stochastic functions. The heterogeneous variance of the sample mean is addressed by the predictive mean of the log variance surrogate model in a two-step approach. We establish an acquisition function that favors exploration across the feasible and optimality-improvable regions to effectively and efficiently solve the stochastic constrained optimization problem. Further, the performance of our proposed method is demonstrated by the extensive numerical and case studies. Note to Practitioners-Many manufacturing processes involve undesirable variations, which create variations in the final products. For example, many emerging manufacturing processes, such as nanomanufacturing, involve complex physical and chemical dynamics and transformation, creating variations in the manufacturing output. In such processes, it is crucial to design the manufacturing processes or products so that they have minimum variations in their quality. Meanwhile, it is also important to maintain the overall quality of the designed processes or products. Furthermore, acquiring data from many advanced manufacturing processes is often very costly, especially in the designing stage. In this work, we propose a data-driven method that automatically finds the best setting of manufacturing processes or products with the minimum variations of quality and a given constraint on the average quality satisfied. Our proposed method is used before conducting every experiment; It analyzes the historical data from previous experiments and provides a setting to be used in the next experiment. Our proposed method efficiently utilizes the historical data, and thus finds the best robust setting by conducting only a small number of experiments.

42 ENGINEERING↗

Adaptive Liquid Crystal Windows

Energy consumption by private and commercial sectors in the U.S. has steadily grown over the last decade. The uncertainty in future availability of imported oil, on which the energy consumption relies strongly, resulted in a dramatic increase in the cost of energy. About 20% of this consumption are used to heat and cool houses and commercial buildings. To reduce dependence on the foreign oil and cut down emission of greenhouse gases, it is necessary to eliminate losses and reduce total energy consumption by buildings. To achieve this goal it is necessary to redefine the role of the conventional windows. At a minimum, windows should stop being a source for energy loss. Ideally, windows should become a source of energy, providing net gain to reduce energy used to heat and cool homes. It is possible to have a net energy gain from a window if its light transmission can be dynamically altered, ideally electronically without the need of operator assistance, providing optimal control of the solar gain that varies with season and climate in the U.S. In addition, the window must not require power from the building for operation. Resolution of this problem is a societal challenge and of national interest and will have a broad global impact. For this purpose, the year-round, all-climate window solution to provide an electronically variable solar heat gain coefficient (SHGC) with a wide dynamic range is needed. AlphaMicron, Inc. (AMI) developed and manufactured 1ft × 1ft prototype panels for the world’s first auto-adjusting Adaptive Liquid Crystal Windows (ALCWs) that can operate from sunlight without the need for external power source and demonstrate an electronically adjustable SHGC. This novel windows are based on AlphaMicron’s patented e-Tint ® technology, a guest-host liquid crystal system implemented on flexible, optically clear plastic films. This technology is suitable both for OEM and aftermarket (retro-fitting) lamination to new and existing windows. Low level of power consumption by ALCWs allows for on-board power electronics for automatic matching of transmission through windows to varying climate conditions without drawing the power from the power grid. ALCWs are capable of transmitting more sunlight in winters to assist in heating and less sunlight in summers to minimize overheating. As such, they can change the window from being a source of energy loss to a source of energy gain. In addition, the scalable AMI’s roll-to-roll process, proved by making 1ft × 1ftALCW prototype panels, allows for cost-effective production of large-scale window panels along with capability to change easily their color and shape. In addition to architectural glazing in houses and commercial buildings, ALCWs can be used in other applications where control of sunlight is needed, such as green houses, used by commercial produce growers and botanical gardens, cars, aircrafts, etc.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Magnetic resonance imaging-targeted, 3D transrectal ultrasound-guided fusion biopsy for prostate cancer: Quantifying the impact of needle delivery error on diagnosis

Purpose: Magnetic resonance imaging (MRI)-targeted, 3D transrectal ultrasound (TRUS)-guided “fusion” prostate biopsy intends to reduce the ∼23% false negative rate of clinical two-dimensional TRUS-guided sextant biopsy. Although it has been reported to double the positive yield, MRI-targeted biopsies continue to yield false negatives. Therefore, the authors propose to investigate how biopsy system needle delivery error affects the probability of sampling each tumor, by accounting for uncertainties due to guidance system error, image registration error, and irregular tumor shapes. Methods: T2-weighted, dynamic contrast-enhanced T1-weighted, and diffusion-weighted prostate MRI and 3D TRUS images were obtained from 49 patients. A radiologist and radiology resident contoured 81 suspicious regions, yielding 3D tumor surfaces that were registered to the 3D TRUS images using an iterative closest point prostate surface-based method to yield 3D binary images of the suspicious regions in the TRUS context. The probabilityP of obtaining a sample of tumor tissue in one biopsy core was calculated by integrating a 3D Gaussian distribution over each suspicious region domain. Next, the authors performed an exhaustive search to determine the maximum root mean squared error (RMSE, in mm) of a biopsy system that gives P ≥ 95% for each tumor sample, and then repeated this procedure for equal-volume spheres corresponding to each tumor sample. Finally, the authors investigated the effect of probe-axis-direction error on measured tumor burden by studying the relationship between the error and estimated percentage of core involvement. Results: Given a 3.5 mm RMSE for contemporary fusion biopsy systems,P ≥ 95% for 21 out of 81 tumors. The authors determined that for a biopsy system with 3.5 mm RMSE, one cannot expect to sample tumors of approximately 1 cm{sup 3} or smaller with 95% probability with only one biopsy core. The predicted maximum RMSE giving P ≥ 95% for each tumor was consistently greater when using spherical tumor shapes as opposed to no shape assumption. However, an assumption of spherical tumor shape for RMSE = 3.5 mm led to a mean overestimation of tumor sampling probabilities of 3%, implying that assuming spherical tumor shape may be reasonable for many prostate tumors. The authors also determined that a biopsy system would need to have a RMS needle delivery error of no more than 1.6 mm in order to sample 95% of tumors with one core. The authors’ experiments also indicated that the effect of axial-direction error on the measured tumor burden was mitigated by the 18 mm core length at 3.5 mm RMSE. Conclusions: For biopsy systems with RMSE ≥ 3.5 mm, more than one biopsy core must be taken from the majority of tumors to achieveP ≥ 95%. These observations support the authors’ perspective that some tumors of clinically significant sizes may require more than one biopsy attempt in order to be sampled during the first biopsy session. This motivates the authors’ ongoing development of an approach to optimize biopsy plans with the aim of achieving a desired probability of obtaining a sample from each tumor, while minimizing the number of biopsies. Optimized planning of within-tumor targets for MRI-3D TRUS fusion biopsy could support earlier diagnosis of prostate cancer while it remains localized to the gland and curable.

60 APPLIED LIFE SCIENCES↗

B-jet and c-jet identification with Neural Networks as well as combination of multivariate analyses for the search for of multivariate analyses for the search for single top-quark production

In the first part of this diploma thesis, the current version of the KIT Flavor Separator, a neural network which is able to distinguish between tagged b-quark jets and tagged c/light-quark jets, is presented. In comparison with previous versions four new input variables are utilized and new Monte Carlo samples with a larger number of simulated events are used for the training of the neural network. It is illustrated that the output of the neural network is continuously distributed between 1 and -1, whereas b-quark jets accumulate at 1, however, c-quark jets and light-quark jets have outputs next to -1. To ensure that the network output describes observed events correctly, the shapes of all input variables are compared in simulation and data. Thus the mismodelling of any input variable is excluded. Moreover, the b jet and light jet output distributions are compared with the output of samples of observed events, which are enhanced in the particular flavor. In contrast to previous versions, no b-jet output correction function has to be calculated, because the agreement between simulation and collision data is excellent for b-quark jets. For the light-jet output, correction functions are developed. Different applications of the KIT Flavor Separator are mentioned. For example it provides a precious input to all three CDF single top quark analyses. Furthermore, it is shown that the KIT Flavor Separator is a universal tool, which can be used in every high-p{sub T} analysis that requires the identification of b-quark jets with high efficiency. As it is pointed out, a further application is the estimation of the flavor composition of a given sample of observed events. In addition a neural network, which is able to separate c-quark jets from light-quark jets, is trained. It is shown, that all three flavors can be separated in the c-net-Flavor Separator plane. As a result, the uncertainties on the estimation of the flavor composition in events with one tagged jet are cut into half. In the second part of this diploma thesis, a method for the combination of three multivariate single-top analyses using an integrated luminosity of 2.2 fb{sup -1} is presented. For this purpose the discriminants of the Likelihood Function analysis, the Matrix Element method and the Neural Network analysis are used as input variables to a neural network. Overall four different networks are trained, one for events with two or three jets and one or two SecVtx tags, respectively. Using a binned likelihood function, the outputs of these networks are fitted to the output distribution of observed events. A single top-quark production cross section of {sigma}{sub single-top} = 2.2{sub -0.7}{sup +0.8} pb is measured. Ensemble tests are performed for the calculation of the sensitivity and observed significance, which are found to be 4.8{sigma} and 3.9{sigma}, respectively. Hence the improvement of this combination is roughly 8% in comparison with sensitivities found by the individual analyses. Due to the proportionality of {sigma}{sub single-top} and |V{sub tb}|{sup 2} and under the assumption V{sub tb} >> V{sub ts}, V{sub td}, a value for |V{sub tb}| is quoted: |V{sub tb}| = 0.88{sub -0.12}{sup +0.14}(exp.) {+-} 0.07(theo.). It can be seen, that the given uncertainties are too large for a verification or falsification of the unitarity assumption of the CKM-matrix. Parallel to this combination a further combination method (NEAT-combination) has been developed. This combination uses a neural network trained with a neuroevolution technique, which optimizes the neural network architecture and weights through the use of genetic algorithms. In this analysis an improvement of roughly 12% could be reached. In figure 7.1 the current situation for the measurement of the single top-quark production cross section is summarized. After collecting more data, CDF will be able to observe single top-quark production with a significance larger than 5.0{sigma}. Nevertheless, the cross section measurement will still have large uncertainties on the level of 20%. Precise measurements on the few percent level will only be possible at the LHC. Recent studies for the CMS detector showed, that the t-channel cross section can be measured with an accuracy of 7% in 1 fb{sup -1} of LHC data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗