Search NASA⌕ Search

SEARCH · Search NASA

Results for “Shock Tube”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Application of program LAURA to perfect gas shock tube flows: A parametric study

The Langley Aerothermodynamic Upwind Relaxation Algorithm (LAURA) was originally developed to solve steady-flow problems. The desire to validate the algorithm with shock tube experimental data motivated the development of a time-accurate version of the LAURA code. The current work presents a test of the Algorithm. Computational results are compared with the exact solution for a simple shock tube case. The parameters examined are Courant number, relaxation sweeps, grid spacing, and the inviscid relaxation factor. The results of the study indicate that LAURA is capable of producing accurate solutions when appropriate values are used for each parameter.

Mitterer, K. F.↗

Radiative cooling of a hydrogen plasma in a shock tube

A method of computing radiative cooling of a hydrogen plasma assuming quasi-isothermal radiative transfer is described. A comparison with nonisothermal calculations for a plane parallel slab indicates good agreement for temperature gradients up to 300 K/cm. The calculations are compared with shock-tube data obtained in the JPL high-performance shock-tube facility. The calculations agreed with the data for one run but were 20 percent high for the other. Due to greater radiative cooling at the test slug boundaries a lateral temperature variation typically exists. This would cause the intensity measurement, which is integrated across the diameter of the test slug, to be below the prediction.

Stickford, G. H., Jr.↗

A shock tube study of line broadening in a temperature range of 6100 to 8300 K

Line widths of the Ca(II) 3968 A and Na(I) 5890 A resonance lines broadened by electric microfields in a plasma were measured. A pressure-driven shock tube was used as the light source. Radiation from the equilibrium region behind the reflected shock wave was studied using a rapid scanning Fabry-Perot interferometer. Electron and argon atom densities of about 8 x 10 to the 16th and 1 x 10 to the 19th/cu cm, respectively, were achieved at the relatively low temperature of around 7500 K by vaporizing a cesium powder that had been added to the shock tube as a solid aerosol in argon gas. The measured line widths were predominantly Stark broadened by the electrons and ions in the plasma, although Doppler, van der Waals, instrument function and optical depth effects had to be taken into account.

Baur, J. F.↗

Condensate Accretion in Shock Tube's Expansion Fan

It has been shown that turbulence and temperature influence the droplet sizes in expansion fan induced condensation by studying the Rayleigh scattering from one port in our shock tube's test section. We have modified our set-up so as to allow, using two ports, the real time measurement of the influence of turbulence and temperature on the rate at which these droplets grow. To do this, we looked at the Rayleigh scattering from two different ports for ten Reynolds numbers at five different temperatures. We modeled the time of flight of droplets, using the equations of one-dimensional gas dynamics and the measured shock wave speed in shock tube's driven section.

Mezonlin, Ephrem-Denis↗

Helium window for shock-tube monochromators

Technique for coupling vacuum ultraviolet monochromator to shock tube to avoid loss of high energy ultraviolet light during quantitative measurements is described. System consists of helium gas window pumping through small aperture in entrance pupil of monochromator. Diagram of equipment and principles of operation are presented.

Thomas, G. M.↗

Shock-tube studies of silicon-compound vapors

Test gas mixtures containing SiO, SiO2, Si2, and SiH were produced in a shock tube by processing shock waves through a mixture of SiCl4 + N2O + Ar, SiH4 + Ar, or SiH4 + O2 + Ar. Absorption spectra of the test gases were studied photographically in the reflected shock region using a xenon flash lamp as the light source in the range of wavelengths between 250 and 600 nm. SiO was found to be a dominant species in the vapors produced by the SiCl4 + N2O and SiH4 + O2 mixtures. Spontaneous combustion was observed in the SiH4 + O2 + Ar mixture prior to the shock arrival, and the resulting solid SiO2 particles evaporated behind the shock wave. Spectral absorption characteristics of SiO, SiO2, Si2, and SiH were determined by studying the test gases.

Park, C.↗

Incident shock-wave characteristics in air, argon, carbon dioxide, and helium in a shock tube with unheated helium driver

Incident shock-wave velocities were measured in the Langley 6-inch expansion tube, operated as a shock tube, with air, argon, carbon dioxide, and helium as test gases. Unheated helium was used as the driver gas and most data were obtained at pressures of approximately 34 and 54 MN/sq m. A range of pressure ratio across the diaphragm was obtained by varying the quiescent test-gas pressure, for a given driver pressure, from 0.0276 to 34.5 kN/sq m. Single- and double-diaphragm modes of operation were employed and diaphragms of various materials tested. Shock velocity was determined from microwave interferometer measurements, response of pressure transducers positioned along interferometer measurements, response of pressure transducers positioned along the driven section (time-of-arrival gages), and to a lesser extent, measured tube-wall pressure. Velocities obtained from these methods are compared and limitations of the methods discussed. The present results are compared with theory and the effects of diaphragm mode (single or double diaphragm), diaphragm material, heating of the driver gas upon pressurization of the driver section, diaphragm opening time, interface mixing, and two-dimensional (nonplanar) flow are discussed.

Miller, C. G., III↗

The shock tube as a tool for dynamic testing of fabrics

Specimens of fabric and Mylar were loaded to failure both statically and dynamically. Static tests were accomplished by pressurizing the specimens and dynamic tests were conducted by firing a shock tube. The results of the study indicate that seam efficiency is degraded by dynamic loads and that a need exists to investigate a seaming procedure which gives an optimum dynamic efficiency. The study also illustrates the lack of correspondence between static and dynamic breaking strengths thereby indicating that fabrics which have dynamic applications should be evaluated using dynamic testing procedures such as the shock tube loading used in the present program.

Madden, R.↗

Absolute measurement of the photoionization cross section of atomic hydrogen with a shock tube for the extreme ultraviolet

The paper reports an experiment which is part of a program to measure the absolute values of the atomic photoionization cross sections of astrophysically abundant elements, particularly in stars and planetary atmospheres. An aerodynamic pressure-driven shock tube constructed from stainless steel with a quadratic cross section was used to measure the photoionization cross section of H I at 19 wavelength points from 910 to 609 A with experimental uncertainties between 7 and 20%. The shock tube was used to produce fully dissociated hydrogen and neon mixtures for the photoabsorption measurements.

Palenius, H. P.↗