Search NASA⌕ Search

SEARCH · Search NASA

Results for “Signal generators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Generating Multiple Calibrating Voltages Simultaneously

Calibrating unit containing signal generator controlled by microprocessor puts out ac signals of known voltages on fifty channels simultaneously. Signals used to calibrate high-frequency tape recorder channels for multiple, ac-coupled strain gauges simultaneously. Calibrating voltage required on each tape channel determined by remote computer, and corresponding data and commands transmitted to microprocessor via modems.

Dutreix, Lionel J.↗

Augmented Human Analysis (AHA)

Radio frequency (RF) signal monitoring generally emphasizes intentionally generated signals, such as WiFi, Bluetooth, or cellular transmissions. However, electronic devices also produce unintended radiated emissions (UREs), which could also be useful in RF spectrum analysis. In either case, deriving intelligence from RF signals is typically a human-intensive process requiring significant domain knowledge. In the Augmented Human Analysis (AHA) project, we investigate the utility of dimensionally aligned signal projection (DASP) and machine learning (ML) algorithms for accelerating RF analysis workflows. We find that while DASP algorithms can indeed highlight signal characteristics relevant for classification tasks, the choice of algorithmic hyperparameters greatly affects performance. To address this challenge, we evaluate the quality of DASP outputs using the silhouette score, which measures how well data points cluster; high silhouette scores indicate good clustering, and thus good hyperparameter values. This approach is critical for machine learning pipelines as the DASP parameters cannot be directly optimized during model training. By identifying good DASP parameters, and thus good DASP outputs, as a preprocessing step, we can decrease the amount of effort required for downstream ML model training. We demonstrate our workflow using a dataset of UREs from common household devices, showing that even without the aid of ML, proper selection of DASP parameters enables clustering by device type.

42 ENGINEERING↗

Measuring Differential Delays With Sine-Squared Pulses

Technique for measuring differential delays among red, green, and blue components of video signal transmitted on different parallel channels exploits sine-squared pulses that are parts of standard test signals transmitted during vertical blanking interval of frame period. Technique does not entail expense of test-signal generator. Also applicable to nonvideo signals including sine-squared pulses.

Hurst, Robert N.↗

A Comprehensive C++ Controller for a Magnetically Supported Vertical Rotor

This manual describes the new FATMaCC (Five-Axis, Three-Magnetic-Bearing Control Code). The FATMaCC (pronounced "fat mak") is a versatile control code that possesses many desirable features that were not available in previous in-house controllers. The ultimate goal in designing this code was to achieve full rotor levitation and control at a loop time of 50 microsec. Using a 1-GHz processor, the code will control a five-axis system in either a decentralized or a more elegant centralized (modal control) mode at a loop time of 56 microsec. In addition, it will levitate and control (with only minor modification to the input/output wiring) a two-axis and/or a four-axis system. Stable rotor levitation and control of any of the systems mentioned above are accomplished through appropriate key presses to modify parameters, such as stiffness, damping, and bias. A signal generation block provides 11 excitation signals. An excitation signal is then superimposed on the radial bearing x- and y-control signals, thus producing a resultant force vector. By modulating the signals on the bearing x- and y-axes with a cosine and a sine function, respectively, a radial excitation force vector is made to rotate 360 deg. about the bearing geometric center. The rotation of the force vector is achieved manually by using key press or automatically by engaging the "one-per-revolution" feature. Rotor rigid body modes can be excited by using the excitation module. Depending on the polarities of the excitation signal in each radial bearing, the bounce or tilt mode will be excited.

Morrison, Carlos R.↗

Modified Penning-Malmberg Trap for Storing Antiprotons

A modified Penning-Malmberg trap that could store a small cloud of antiprotons for a relatively long time (weeks) has been developed. This trap is intended for use in research on the feasibility of contemplated future matter/antimatter-annihilation systems as propulsion sources for spacecraft on long missions. This trap is also of interest in its own right as a means of storing and manipulating antiprotons for terrestrial scientific experimentation. The use of Penning-Malmberg traps to store antiprotons is not new. What is new here is the modified trap design, which utilizes state-of-the-art radiofrequency (RF) techniques, including ones that, heretofore, have been used in radio-communication applications but not in iontrap applications. A basic Penning-Malmberg trap includes an evacuated round tube that contains or is surrounded by three or more collinear tube electrodes. A steady axial magnetic field that reaches a maximum at the geometric center of the tube is applied by an external source, and DC bias voltages that give rise to an electrostatic potential that reaches a minimum at the center are applied to the electrodes. The combination of electric and magnetic fields confines the charged particles (ions or electrons) for which it was designed to a prolate spheroidal central region. However, geometric misalignments and the diffusive cooling process prevent the steady fields of a basic Penning- Malmberg trap from confining the particles indefinitely. In the modified Penning-Malmberg trap, the loss of antiprotons is reduced or eliminated by use of a "rotating-wall" RF stabilization scheme that also heats the antiproton cloud to minimize loss by matter/antimatter annihilation. The scheme involves the superposition of a quadrupole electric field that rotates about the cylindrical axis at a suitably chosen radio frequency. The modified Penning-Malmberg trap (see Figure 1) includes several collinear sets of electrodes inside a tubular vacuum chamber. Each set comprises either a single metal tube or else a tube that is segmented into four electrodes that subtend equal angles about the cylindrical axis. The output of an RF signal generator is fed through a 90 hybrid coupler and then through two baluns to generate four replicas of the signal at relative phase shifts of 0 , 90 , 180 , and 270 (see Figure 2). These signal replicas are fed through 6-dB directional couplers, then via coaxial cables to the vacuum chamber. The signal is then routed to a phase cancellation network, which filters out the drive signal with the difference representing the plasma interaction. Inside the vacuum chamber, twisted-pair wires feed the signals from the coaxial cables to the four electrodes of each segmented electrode tube.

Sims, William H.↗

In-Situ Wire Damage Detection System

An in-situ system for detecting damage in an electrically conductive wire. The system includes a substrate at least partially covered by a layer of electrically conductive material forming a continuous or non-continuous electrically conductive layer connected to an electrical signal generator adapted to delivering electrical signals to the electrically conductive layer. Data is received and processed to identify damage to the substrate or electrically conductive layer. The electrically conductive material may include metalized carbon fibers, a thin metal coating, a conductive polymer, carbon nanotubes, metal nanoparticles or a combination thereof.

Williams, Martha K.↗

Controlling the operating speed of stages of an asynchronous pipeline

An asynchronous pipeline includes a first stage and one or more second stages. A controller provides control signals to the first stage to indicate a modification to an operating speed of the first stage. The modification is determined based on a comparison of a completion status of the first stage to one or more completion statuses of the one or more second stages. In some cases, the controller provides control signals indicating modifications to an operating voltage applied to the first stage and a drive strength of a buffer in the first stage. Modules can be used to determine the completion statuses of the first stage and the one or more second stages based on the monitored output signals generated by the stages, output signals from replica critical paths associated with the stages, or a lookup table that indicates estimated completion times.

97 MATHEMATICS AND COMPUTING↗

Controlling the operating speed of stages of an asynchronous pipeline

An asynchronous pipeline includes a first stage and one or more second stages. A controller provides control signals to the first stage to indicate a modification to an operating speed of the first stage. The modification is determined based on a comparison of a completion status of the first stage to one or more completion statuses of the one or more second stages. In some cases, the controller provides control signals indicating modifications to an operating voltage applied to the first stage and a drive strength of a buffer in the first stage. Modules can be used to determine the completion statuses of the first stage and the one or more second stages based on the monitored output signals generated by the stages, output signals from replica critical paths associated with the stages, or a lookup table that indicates estimated completion times.

Sadowski, Greg↗

Evaluation of Galvanic Vestibular Stimulation System

Microgravity exposure results in an adaptive central reinterpretation of information from multiple sensory sources to produce a sensorimotor state appropriate for motor actions in this unique environment, but this new adaptive state is no longer appropriate for the 1-g gravitational environment on Earth. During these gravitational transitions, astronauts experience deficits in both perceptual and motor functions including impaired postural control, disruption in spatial orientation, impaired control of locomotion that include alterations in muscle activation variability, modified lower limb kinematics, alterations in head-trunk coordination as well as reduced dynamic visual acuity. Post-flight changes in postural and locomotor control might have adverse consequences if a rapid egress was required following a long-duration mission, where support personnel may not be available to aid crewmembers. The act of emergency egress includes, but is not limited to standing, walking, climbing a ladder, jumping down, monitoring displays, actuating discrete controls, operating auxiliary equipment, and communicating with Mission Control and recovery teams while maintaining spatial orientation, mobility and postural stability in order to escape safely. The average time to recover impaired postural control and functional mobility to preflight levels of performance has been shown to be approximately two weeks after long-duration spaceflight. The postflight alterations are due in part to central reinterpretation of vestibular information caused by exposure to microgravity. In this study we will use a commonly used technique of transcutaneous electrical stimulation applied across the vestibular end organs (galvanic vestibular stimulation, GVS) to disrupt vestibular function as a simulation of post-flight disturbances. The goal of this project is an engineering human-in-the-loop evaluation of a device that can degrade performance of functional tasks (e.g. to maintain upright balance) similar to what astronauts experience during transitions to new gravitational environments. Stochastic electrical stimulation can be applied to the vestibular system through electrodes placed over the mastoid process behind the ears in the binaural configuration resulting in stimulation in the mediolateral (side-to-side) plane. An additional electrode can be placed over the bony landmark of the tip of the c7 spinous process for the double monaural configuration, which will cause stimulation in the anteroposterior (forward-backward) plane. A portable constant current bipolar stimulator with subject isolation was designed and built to deliver the stimulus. The unit is powered using a 3.7 V battery pack and designed to produce currents up to 5 mA. The stimulator, controlled by a Raspberry Pi 3 computer, offers several stimulus signal generation options including a standalone mode, which uses onboard signal files stored on the flash memory card. Stochastic stimulation signals will be generated in 0-30 Hz frequency bandwidth. Stimulation amplitude can be increased incrementally to a maximum amplitude of 5.0 mA (e.g., 0, 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 4.5, 5.0 mA). In control trials, subjects will be experiencing vestibular stimulation with 0-mA current applied through the electrodes. The system will be evaluated at various levels of stimulation and in both the binaural and double monaural electrode configurations. One of the objectives is to identify stimulation levels producing effects most comparable to the post-flight disturbances. This is a pilot study that will set the stage for a larger, more comprehensive study that will investigate wider aspects of post-flight sensorimotor dysfunction and set sensorimotor standards for crew health.

Kofman, I. S.↗

A Harmonics Interferometric Doppler Sensor With a Neon Lamp Detector

A cost-effective harmonic interferometric Doppler sensor has been developed to obtain both amplitude and phase of the micro-Doppler signatures of moving objects. A phase chopper is used to generate the harmonics of the interferometry signal. For cost-effectiveness, a Gunn diode source is used for signal generation and a neon lamp is employed as a broadband detector. An advanced signal processing algorithm has been developed to extract both amplitude and phase Doppler signatures. A prototype has been built to demonstrate the effectiveness of the harmonic interferometric Doppler sensor at 35 GHz, with Doppler objects such as human hand and metal objects. In addition, the broadband detection capability of the neon lamp allows the Doppler sensor to work up to the millimeter-wave regime and potentially beyond the terahertz (THz) wave regime. Due to the ruggedness of the neon lamp detector, it is expected that the Doppler sensor has important applications of sensing and wireless communication in harsh environment such as high-temperature, high-power and radioactive conditions.

Doppler sensor↗

Virtual and Augmented Reality Applications in Science and Engineering

The articles in this special section focus on virtual and augmented reality applications in science and engineering. There has been an explosive growth in visually augmenting the spaces around us by creating environments where visual, aural, and kinesthetic immersive experiences afforded by virtual and augmented reality (AR) powerfully engage us in a way no other medium can. Virtual reality (VR) recreates the sensory world around us entirely through computer-generated signals of sight, sound, touch (and in some cases smell and taste). AR overlays the computer-generated sensory signals on the real world allowing the user to experience a rich juxtaposition of the virtual and the real worlds simultaneously. Together, these technologies are transforming the way people from all walks of life—scientists, engineers, educators, industrial workers, health care professionals, artists, and everyday people— see and use the information that matters most to them, in an intuitive embodied way. Just as mobile technology has revolutionized how we communicate with each other and with our digital worlds, ubiquitous VR and AR will fundamentally alter how our society creates, inspires, engages, and learns from the information-rich and enriched cyberspaces around us. While affordable consumer- quality VR and AR hardware is becoming available, significant work is needed to adopt VR and AR for important and difficult scientific and societal applications.

Virtual Reality, Augmented Reality↗

A dual frequency VLF timing system.

Dual frequency VLF timing system for synchronization of remotely located clocks, noting WWVL radio carrier frequency, signal generator, etc

VERY LOW FREQUENCY↗

Design and performance of the Fermilab Constant Fraction Discriminator ASIC

Here, we present the design and performance characterization results of the novel Fermilab Constant Fraction Discriminator ASIC (FCFD) developed to readout low gain avalanche detector (LGAD) signals by directly using a constant fraction discriminator (CFD) to measure signal arrival time. Silicon detectors with time resolutions less than 30ps will play a critical role in future collider experiments, and LGADs have been demonstrated to provide the required time resolution and radiation tolerance for many such applications. The FCFD has a specially designed discriminator that is robust against amplitude variations of the signal from the LGAD that normally requires an additional correction step when using a traditional leading edge discriminator. The application of the CFD directly in the ASIC promises to be more reliable and reduces the complication of evolving time-walk corrections throughout the operational lifetime of the detector system. We will present a summary of the measured performance of the FCFD for input signals generated by internal charge injection, LGAD signals from an infrared laser, and LGAD signals from minimum-ionizing particles. The mean time response for LGAD signals with charge ranging between 5 and 26 fC has been measured to vary no more than 10ps, orders of magnitude more stable than an uncorrected leading edge discriminator based measurement, and effectively removes the need for any additional time-walk correction. The measured contribution to the time resolution from the FCFD ASIC is found to be 10ps for signals with charge above 20fC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectroscopic performance of Low-Gain Avalanche Diodes for different types of radiation

LGADs (Low-Gain Avalanche Diodes or Detectors) are a type of silicon Avalanche Photo-Diodes originally developed for the fast detection of minimum ionizing particles in high-energy physics experiments. Thanks to their fast timing performance, the LGAD paradigm enables detectors to accurately measure minimum ionizing particles with a timing resolution of a few tens of picoseconds. Such a performance is due to a thin substrate and the presence of a moderate signal gain. This internal gain of a few tens is enough to compensate for the reduced charge deposition in the thinner substrate and the noise of fast read-out systems. While LGADs are optimized for the detection of minimum ionizing particles for high-energy particle detectors, it is critical to study their performance for the detection of different types of particle, such as X-rays, gamma-rays, or alphas. In this paper, we evaluate the gain of three types of LGADs: two devices with different geometries and doping profiles fabricated by Brookhaven National Laboratory, and one fabricated by Hamamatsu Photonics with a different process. Since the gain in LGADs depends on the bias voltage applied to the sensor, pulse-height spectra have been acquired for bias voltages spanning from the depletion voltage up to the breakdown voltage. Finally, the signal-to-noise ratio of the generated signals and the shape of their spectra allow us to probe the underlying physics of the multiplication process.

47 OTHER INSTRUMENTATION↗

A computer-aided telescope pointing system utilizing a video star tracker

The Video Inertial Pointing (VIP) System developed to satisfy the acquisition and pointing requirements of astronomical telescopes is described. A unique feature of the system is the use of a single sensor to provide information for the generation of three axis pointing error signals and for a cathode ray tube (CRT) display of the star field. The pointing error signals are used to update the telescope's gyro stabilization and the CRT display is used by an operator to facilitate target acquisition and to aid in manual positioning of the telescope optical axis. A model of the system using a low light level vidicon built and flown on a balloon-borne infrared telescope is briefly described from a state of the art charge coupled device (CCD) sensor. The advanced system hardware is described and an analysis of the multi-star tracking and three axis error signal generation, along with an analysis and design of the gyro update filter, are presented. Results of a hybrid simulation are described in which the advanced VIP system hardware is driven by a digital simulation of the star field/CCD sensor and an analog simulation of the telescope and gyro stabilization dynamics.

Murphy, J. P.↗

Ultra stable frequency distribution system

A system is presented for synchronizing a signal at a remotely located slave station with the phase and frequency of a signal generated at a master station. The signal transmitted at the master station and received by the slave station provides compensation for the phase shift caused by the transmission path delays between the master and slave station. The slave station transmits a signal to the master station at a frequency that is different from the frequency of the signal being transmitted by the master station. The signal transmitted by the slave station is received by the master station while the master station transmitter is off. The signal transmitted by the master station is received by the slave station while the slave station transmitter is off.

Sydnor, R. L.↗

Photoelectric detection system

A photoelectric beam system for the detection of the arrival of an object at a discrete station wherein artificial light, natural light, or no light may be present is described. A signal generator turns on and off a signal light at a selected frequency. When the object in question arrives on station, ambient light is blocked by the object, and the light from the signal light is reflected onto a photoelectric sensor which has a delayed electrical output but is of the frequency of the signal light. Outputs from both the signal source and the photoelectric sensor are fed to inputs of an exclusively OR detector which provides as an output the difference between them. The difference signal is a small width pulse occurring at the frequency of the signal source. By filter means, this signal is distinguished from those responsive to sunlight, darkness, or 120 Hz artificial light. In this fashion, the presence of an object is positively established.

Currie, J. R.↗

Assessments and Applications of Terra and Aqua MODIS On-Orbit Electronic Calibration

MODIS has 36 spectral bands located on four focal plane assemblies (FPAs), covering wavelengths from 0.41 to 14.4 micrometers. MODIS bands 1-30 collect data using photovoltaic (PV) detectors and, therefore, are referred to as the PV bands. Similarly, bands 31-36 using photoconductive (PC) detectors are referred to as the PC bands.The MODIS instrument was built with a set of on-board calibrators (OBCs) in order to track on-orbit changes of its radiometric, spatial, and spectral characteristics. In addition, an electronic calibration (ECAL) function can be used to monitor on-orbit changes of its electronic responses (gains). This is accomplished via a series of stair step signals generated by the ECAL function. These signals, in place of the FPA detector signals, are amplified and digitized just like the detector signals. Over the entire mission of both Terra and Aqua MODIS,the ECAL has been performed for the PV bands and used to assess their on-orbit performance. This paper provides an overview of MODIS on-orbit calibration activities with a focus on the PV ECAL, including its calibration process and approaches used to monitor the electronic performance. It presents the results derived and lessons learned from Terra and Aqua MODIS on-orbit ECAL. Also discussed are some of the applications performed with the information provided by the ECAL data.

Xiong, Xiaoxiong↗