SEARCH · Search NASA
Results for “Signal generators”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Practical Start-Up Process of Multiple Grid-Tied Voltage-Sourced Inverters in Laboratory
Starting up inverter-based resources (IBRs) and integrating them into a grid are important in real-world engineering and there are many challenges to be tackled. Using a laboratory-scale hardware test bed (50 Watt and 20 V), this paper demonstrates the challenges and provides a practical start-up process that can smoothly energize two grid-tied voltage-sourced inverters (VSI) and synchronize the VSIs into a 60-Hz grid. The hardware test bed consists of two SiC VSIs and a 45-kW Chroma grid simulator to act as the grid. The inverter controls are implemented in OPAL-RT OP5600, which has the measurements sensed, control algorithms processed, and gate signals generated and sent to the VSI switches. This research focuses on examining how to energize VSIs and how to synchronize the VSIs into the grid. The best energizing approach is summarized based on comparison and analysis of the experiment results. The presented approach can prevent large transients during the start-up process.
Clustering Interval Load with Weather to Create Scenarios of Behind-the-Meter Solar Penetration
Forecasting load at the feeder level has become increasingly challenging with the penetration of behind-the-meter solar, as this self-generation is only visible to the utility as aggregated net-load. This work proposes a methodology for creation of scenarios of solar penetration at the feeder level for use by forecasters to test the robustness of their algorithm to progressively higher penetrations of solar. The algorithm draws on publicly available observations of weather condition (e.g., rainy/cloudy/fair) for use as proxies to sky clearness. These observations are used to mask and weight the interval deviations of similar native usage profiles from which average interval usage is calculated and subsequently added to interval net generation to reconstruct interval total generation. This approach improves the estimate of annual energy generation by 23%; where the net generation signal currently reflects 52% of total annual gener- ation, now 75% is captured. This methodology for creation of forecast testing scenarios is data driven and extensible to service territories which lack information on irradiance measurements and geocoordinates.
Cryogenic Front-End ASICs for Low-Noise Readout of Charge Signals
This paper presents design details and measurement results of LArASIC, a front-end application specific integrated circuit (ASIC) designed for low-noise readout of charge signals generated in neutrino study experiments within liquid argon time projection chambers. LArASIC comprises of 16-channels of programmable charge amplification and pulse shaping stages that provide a voltage readout proportional to the input charge and was optimized for operation at liquid argon temperature, i.e., 89 K. The chip was fabricated in a 180 nm CMOS process. Measurements at liquid nitrogen temperature, i.e., 77 K, indicate that the channel outputs have high linearity (INL < 0.1%) within the operating range, an equivalent noise charge of 534 electrons for a peaking time of 1 µs and a detector capacitance of 150 pF, and a worst-case inter-channel cross-talk of 0.35%. The paper also presents design choices made in the process of migrating LArASIC to CHARMS, an ASIC to be fabricated in a 65 nm process that includes all features provided by LArASIC, along with additional digital programmability for improved robustness and flexibility. CHARMS is intended for use in future high-energy physics experiments that require high-resolution charge or light readout with shorter pulse peaking times.
Development and Evaluation of a Cost-Effective Behind-the-Meter Synchronized Measurement Unit for Enhanced Grid Integration
This paper presents the development of the Inverter Based Resource Monitor (IBRM), an innovative behind-the-meter synchronized measurement unit (SMU) tailored for integration with inverter-based resources (IBRs). The IBRM distinguishes itself as a highly accurate and cost-effective SMU, offering facile deployment and connectivity to IBRs. It is equipped to conduct real-time voltage and current waveform analyses, serving as a phasor measurement unit (PMU) with exceptionally rapid synchrophasor transmission capabilities. The device incorporates a cutting-edge dual-core architecture designed to minimize sampling delays inherent to its microprocessor, thereby enhancing the precision of synchronized waveform measurements. Moreover, the IBRM is adept at recording high-fidelity waveform data, capturing nuances such as waveform distortions, high-order harmonics, and wide-band oscillations prevalent in power grids with substantial IBR presence. A prototype of the IBRM has been constructed and subjected to rigorous testing to assess its functional capabilities and measurement precision, utilizing both idealized signal generators and a real-world off-grid inverter setup as benchmarks.
solar-fingerprinting
An algorithm for creating a low-dimensional representation (fingerprint) of daily photovoltaic solar power generation signals.
Evaluation of the Tenti S6 model for hydrocarbon fuels at elevated temperatures using filtered Rayleigh scattering measurements
This Letter targets the assessment of the well-known Tenti S6 model for predicting the Rayleigh–Brillouin scattering (RBS) spectra of select gas–phase hydrocarbon fuels (CH 4 , C 2 H 2 , C 2 H 4 , C 3 H 8 , and C 4 H 10 ) over a temperature range of 300 to 700 K. The Tenti S6 model is evaluated by comparing filtered Rayleigh scattering (FRS) measurements to synthetic FRS signals generated from the combination of the Tenti S6 output and an accurate iodine absorption filter model. Here, the experimental and synthetic FRS results agree very well (<3% difference) over the full temperature range for CH 4 , C 2 H 2 , and C 2 H 4 , indicating accurate calculation of the RBS spectra. For C 3 H 8 and C 4 H 10 , there are some large differences between the experimental and synthetic FRS results which cannot be resolved through tuning of bulk viscosity, internal heat capacity, or inclusion of vibrational degrees of freedom, suggesting the need for detailed measurements of the Rayleigh–Brillouin spectra.
Spatiotemporal imaging and manipulation of surface plasmons
Abstract Surface plasmon polaritons (SPPs) are travelling surface waves that have shown promise for applications in nanophotonics as they provide a direct route toward photon-mediated electrical signal generation – a central paradigm for speeding up and scaling down photonic elements. SPP waves have also generated fundamental interest due to their high-field strength and sub-wavelength confinement, properties that have enabled the surface-enhanced Raman effect. Over the last decade, photoemission electron microscopy (PEEM) has emerged as a pioneering technique for imaging surface electric fields through ultrashort laser pulse mediated electron emission and has therefore become an indispensable tool for characterizing plasmonic phenomena at interfaces in a variety of materials. PEEM offers nanometer spatial resolution and femtosecond temporal resolution, allowing SPPs to be prepared, monitored, and manipulated on the nanometer-femtosecond scale. Through a brief review of recent reports, we aim to introduce PEEM-based SPP imaging and manipulation modalities and highlight their utility in the context of emerging nanoscale and quantum materials science advancements.
Closed-loop electron-beam-induced spectroscopy and nanofabrication around individual quantum emitters
Color centers in diamond play a central role in the development of quantum photonic technologies, and their importance is only expected to grow in the near future. For many quantum applications, high collection efficiency from individual emitters is required, but the refractive index mismatch between diamond and air limits the optimal collection efficiency with conventional diamond device geometries. While different out-coupling methods with near-unity efficiency exist, many have yet to be realized due to current limitations in nanofabrication methods, especially for mechanically hard materials like diamond. Here, we leverage electron-beam-induced etching to modify Sn-implanted diamond quantum microchiplets containing integrated waveguides with a width and thickness of 280 nm and 200 nm, respectively. This approach allows for simultaneous high-resolution imaging and modification of the host matrix with an open geometry and direct writing. When coupled with the cathodoluminescence signal generated from the electron–emitter interactions, we can monitor the enhancement of the quantum emitters in real-time with nanoscale spatial resolution. The operando cathodoluminescence measurement and fabrication around single photon emitters demonstrated here provide a new foundation for the potential control of emitter–cavity interactions in integrated quantum photonics.
Local-Distance Seismic Event Relocation and Relative Magnitude Estimation, Applications to Mining Related Seismicity in the Powder River Basin, Wyoming
Recent efforts to characterize small ( M w < 3 ) seismic events at local distances have become more important because of the increased observation of human-triggered and induced seismicity and the need to advance nuclear explosion monitoring capabilities. The signals generated by low-magnitude seismic sources necessitate the use of nearby short-period observations, which are sensitive to local geological heterogeneity. Local to near-regional distance ( < 300 km ) surface and shear waves can dominate short-period observations from small, shallow seismic sources. In this work, we utilize these observations to estimate precise, relative locations and magnitudes of ~ 700 industrial mining events in Wyoming, using nearly 360,000 observations. The precise, relative location estimates (with formal location uncertainty estimates of less than 1 km) collapse a diffuse collection of mining events into discrete clusters associated with individual blasting operations. We also invert the cross-correlation amplitudes to estimate precise, relative moment magnitude estimates, which help validate and identify disparities in the event sizes reported by regional network catalogs. Joint use of multiple phases allows for the inclusion of more seismic events due to the increase in the number of observations. In some cases, using a single phase allowed us to relocate only 50% of the original reported seismic events within a cluster. Combining shear- and surface-wave phases increased the number of events to above 90% of the original events, allowing us to characterize a broader range of event sizes, source to station distances, and event distributions. This analysis takes a step toward making a fuller characterization of small industrial seismic events observed at local distances.
Comparison of Infrasound Wind Noise Reduction Systems for Use in Temporary Deployments
Infrasound, or low frequency sound 20 Hz, is produced by a variety of natural and anthropogenic sources. Wind also generates signals within this frequency band and serves as a persistent source of infrasonic noise. Infrasound sensors measure pressure fluctuations, which scale with the ambient density and velocity fluctuations of ground winds. Here we compare four different wind noise reduction systems, or "filters", and make recommendations for their use in temporary infrasound deployments. Our results show that there are two filters that are especially effective at reducing wind noise: (1) a Hyperion high frequency (HF) shroud with a 1 m diameter metal mesh dome placed on top and (2) a Hyperion Four Port Garden Hose shroud with 4 Miracle-Gro Soaker System garden hoses. We also find that placing a 5-gallon bucket over the HF wind shroud should not be done as it provides a negligible decrease in noise up to ~ 1 Hz and then an increase in noise. We conclude that it is up to the researcher to determine which of the other filters is best for their needs based on location and expense. We anticipate this study will be used as a resource for future deployments when a wind noise reduction method is necessary but only needed for a limited time period.
Circuit QED Pulse Control Interface
The Circuit Quantum Electrodynamics (Circuit QED) Pulse Control Interface provides a robust platform for designing and testing control signals in transmon-cavity systems. Utilizing a PyQt5-based drag-and-drop GUI, this tool facilitates the implementation of two key protocols: Selective Number-dependent Arbitrary Phase (SNAP)-Displacement and Echoed Conditional Displacement (ECD). It offers real-time pulse visualization and supports CSV exports and imports for integrating custom signals, thereby enhancing circuit QED experimental workflows. Simulations performed using QuTiP confirm the high fidelity of quantum state preparations and the effectiveness of the implemented controls. Future developments will focus on interfacing the tool with hardware and enhancing signal generation accuracy.
Noise Reduction Capability of the Trampoline Fabric Wind Dome
Low frequency sound below 20 Hz, also known as infrasound, is generated by both natural and anthropogenic sources. Local surface winds also generate signals within this frequency band and can dominate signals. Effectively monitoring sources of interest requires filtering out the influence of wind. Recently, the National Center for Physical Acoustics developed a 1 m fabric dome made from trampoline material that can serve as a wind filter for temporary field deployments. We assess the performance of this new dome by quantifying its overall noise reduction and show that it is an acceptable wind filter for temporary infrasound field deployments.
Description of the Gas Sampling and Circulation System for the LYNM PE1-A Experiment
A series of multiphysics experiments, referred to as Physics Experiment 1 (PE1) is underway at the U.S. Nevada National Security Site. The PE1 series includes detonations of three underground chemical explosions. As the name implies, there are a number of experiments investigating the signals generated by the explosion. The experiment series objectives are outlined in a report from Lawrence Livermore National Laboratory.1 One of the experiments is a gas migration experiment. Gas tracers were imbedded in the explosives and gas sampling boreholes were installed in the formation in the test bed. Connected to the monitoring points is a circulation system that moves gas to a central measurement location. This report does not describe the gas analysis or collection systems, but rather the circulation system that provides the gas for measurement. Here, we have combined four project documents into a single report that describes the design, build, installation, testing, and operation of the gas sampling network.
Low Yield Nuclear Monitoring Physics Experiment 1 – Integrated Data Acquisition System Design and Initial Observations
The report documents the design of the Integrated Data AcQuisition (IDAQ) system and observations recorded during the first in a series of underground chemical explosions conducted on the Nevada National Security Site (NNSS) in southern Nevada. Experiments are funded as part of Low Yield Nuclear Monitoring (LYNM) research and development within the United States National Nuclear Security Administration NA-22 nuclear non-proliferation program. The series is part of the broader Physical Experiment 1 (PE1) being conducted in and around the P-tunnel facility on the NNSS. Each explosive experiment utilizes several tons of comp-B to generate signals recorded by a broad suite of instrumentation. The IDAQ serves as the backbone for all subsurface instrumentation providing precise time synchronization, remote control, data exfiltration and backup, along with recording several sensing modalities throughout the underground complex that includes ground motion, environmental conditions, and electromagnetic signals.
Precision Polishing of Spheres Via In-Situ Process Monitoring and Machine-Learning-Based Optimization
In inertial confinement fusion (ICF) experiments seeking output gains of unity and beyond, the quality of the ablator capsule is paramount for minimizing hydrodynamic mix that quenches the central hot spot. Defects in the form of foreign particles or missing mass on the surface and within the wall of the capsule are primary offenders. High density carbon capsules made for ICF experiments on the National Ignition Facility (NIF) are precision polished to achieve the surface smoothness in the order of a few nm as well as to minimize isolated defects in the form of pits. Given the critical role of this process, we are developing smart manufacturing techniques with goal of elevating the efficiency of this process. Our approach is to use MEMS-based sensors to capture the fine vibrational signals generated during the polishing process and combine it with synchronized visual feedback as needed. Beyond using these sensors for process monitoring, we use specific deep learning methods to analyze the data and extract correlations with both the process parameters and the final performance of the polishing run. Here, we describe the multiple fronts that we have explored in this regard and the results we have gotten so far. This approach promises to have the potential to ultimately provide real-time feedback that can be used for ensuring the progress of the run as well as a means for faster optimization.
Characterizing the energy resolution of the MicroBooNE LArTPC at the MeV scale using monoenergetic features of 208-Tl decays
A proper understanding of the capabilities and fidelity of low-energy reconstruction is crucial for taking advantage of MeV-scale neutrino physics opportunities in LArTPCs. This poster will present an analysis resulting in the first-ever demonstration of LArTPC energy resolution in the MeV regime. A measurement of the resolution of energy reconstruction in the MicroBooNE LArTPC at ~1.5 MeV was performed using monoenergetic signals generated by 208Tl decay gamma-rays pair-producing in the detector. This study provides a pathway for MeV-scale monoenergetic energy calibrations in future LArTPC experiments.
Detector architecture and data flow of the CMS HGCAL Phase-2 Endcap Calorimeter Upgrade
The CMS High Granularity Calorimeter (HGCAL) is the Phase-2 endcap calorimeter upgrade for the High-Luminosity Large Hadron Collider, designed to provide precise spatial, energy, and timing measurements in a high-radiation, high-pileup environment. This work presents an overview of the HGCAL assembly process, detector architecture, and end-to-end data flow. The data flow goes from signal generation in silicon sensors and scintillator tiles through front-end electronics, optical transmission, and back-end data acquisition. The study highlights how the integrated detector, electronics, and readout systems enable efficient event reconstruction and support the physics objectives of the HL-LHC.