An impactor, system and method for performing real-time measurements of particles in aerosol gases. The impactor comprises a plurality of cascading stages having impaction plates, mass-measurement mechanisms retained on the impaction plates, and a nozzle plate. A signal line associated with each of the plurality of cascading stages is configured to relay signals from the mass-measurement mechanism of the associated stage to a computer-based system configured to receive the transmitted signals from the signal lines, and to correlate changes in the resonant frequencies to particle concentrations in real time.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
During a Geologic Carbon Storage process, supercritical CO 2 (scCO 2 ) is subjected to a series of dynamic and static conditions where the relationship between pore geometry and the trapped scCO 2 curvature remains to be established. To mimic the dynamic process, two sandstones, Bentheimer and Nugget, were subjected to two successive drainage and imbibition (D-I) cycles and X-ray computed tomography scanned at each residual state to capture the wettability evolution at static conditions in the same pore geometry. Both sandstones contain similar grain size distributions, pore size distributions, and pore interconnectivity but differ in that the Nugget formation contains approximately half the porosity of the Bentheimer sandstone, and the pore network contains dead-end pores. scCO 2 size distributions, strain calculations, and geometric contact angle measurements were used to characterize the curvature of scCO 2 in different pore types between cycles. An increase in geometric contact angle was the greatest when advancement along the pore network of the same ganglion occurred between cycles while strain increased the most with pore-filling trapping. Moreover, Nugget sandstone results in a greater aggregated residual saturation and shows a clear increase in scCO 2 sizes with an additional D-I cycle while scCO 2 in the Bentheimer core shows a more complex response with some ganglion increasing and some decreasing in size with an additional D-I cycle. From this work, we suspect the pore geometry is playing a role in scCO 2 size distributions and use this information to suggest using water pulses to enhance trapping capacity in lower porosity sandstones.
The microfracture-pore structures and water-rock interactions of eight samples of three typical lithofacies (three limestone, three wackestone, and two mudstone) from the Lower Eagle Ford Formation have been investigated using an integrated methodology. The methods used were X-ray diffraction (XRD), total organic carbon (TOC) content, pyrolysis, thin-section petrography, scanning electron microscopy (SEM), mercury intrusion porosimetry (MIP), spontaneous water imbibition, and water vapor & nitrogen physisorption. Petrophysical properties such as organic richness, maturity, mineral composition, types and patterns of microfractures and pores, porosity, pore-throat size distribution, pore size distribution, pore connectivity, water adsorption and desorption behavior were determined from these methods, and the results compared among the three lithofacies. For example, the three limestone EAS samples and three wackestone DM samples show a low porosity range from 2.02–3.35%, whereas the two mudstone VRU samples exhibit a much large average porosity of 11.7% by MIP results. Nitrogen physisorption results show that pore size distributions have a good similarity in N2 adsorption volume for the samples with similar lithology. Microfractures are morphologically divided into seven types, with their definitions & pictorial examples presented and possible formation mechanisms proposed. In addition, the water vapor physisorption behavior and their controlling factors are discussed. Here, the water adsorption capacity shows a positive relationship (R 2 = 0.90) with clay content and a negative relationship (R 2 = 0.99) with carbonate content. In general, this integrated study of microfracture-pore structure characterization and water-rock interaction provides some insights of water vapor adsorption behavior in different lithofacies and whether microfractures could be an important pathway for fluid flow.
Local conditions, such as temperature and oxygen availability, have a pronounced effect on the formation and evolution of fallout following a nuclear explosion. While the behavior of nuclear-relevant materials such as uranium has begun to be explored under a wider range of environments, little is known about the behavior of plutonium. Here, using cerium as a surrogate, we track the vapor-phase aggregation of cerium oxide nanoparticles created in a plasma flow reactor under conditions of controlled temperature at two different oxygen fugacities. In situ optical emission spectroscopy is used to measure the variations in the spectral intensity of atomic and molecular species with temperature and oxygen content. We find that the relative rate of gas-phase oxidation of cerium is highly dependent on both temperature and local redox conditions within the flow reactor, to the extent that doubling the oxygen availability effectively doubles the amount of vapor-phase cerium monoxide at high temperatures (>2000 K). Condensed cerium oxide nanoparticles are also collected and analyzed ex situ via transmission electron microscopy and grazing-incidence small-angle X-ray scattering to determine their elemental composition, crystal structure, and size distribution. The size and morphology of the condensed nanoparticles are independent of local redox conditions, forming the same crystal type with the same size distribution regardless of oxygen availability. Postcondensation particle evolution, however, is found to be predominantly driven by temperature, with the average particle size increasing as particles cool and subsequently aggregate. These results expand our understanding of the chemical and physical behavior of refractory oxides that form during the early stages of fallout formation.
An empirical model is presented that describes anode-side losses related to porous transport layer (PTL) morphology in proton exchange membrane water electrolysis (PEMWE). The model is based on an advanced voltage breakdown analysis that links various overpotentials to PTL morphology. Custom Ti PTLs, spanning uncommonly low porosities (22 - 31%), were fabricated and analyzed with X-ray CT to obtain pore and particle size distributions. Particle size distributions were consistent across samples with an average particle diameter of 12.0?..mu..m, whereas average pore diameters ranged from 6.0 to 7.0?..mu..m. The PTLs were tested in standard PEMWE cell assemblies with anode catalyst loadings of 0.1 mgIr cm-2 to obtain polarization curves, electrochemical impedance spectra, and augmented Tafel analysis. The PTL-dependent anode side losses were deconvoluted and assigned to excess utilization, concentration, ion transport resistance, and electrical contact resistance overpotentials. The data and model reveal an optimal 20 - 28% PTL porosity region where utilization and contact resistance overpotentials are minimized without triggering concentration and ion transport losses related to water deprivation. The optimal PTL porosity depends on the operating current density and is demonstrated at realistic PEMWE water flow rates to establish PTL design guidance for operation at scale.
In this work, a previously validated coupling of Kinetic Monte Carlo (KMC) Potts Model and finite element method (FEM) simulations was implemented to investigate the effects of microstructural features in as-cast and homogenized monolithic U-10Mo foils on the emergent microstructure after rolling and reheating. Parameters that could potentially affect recrystallization behavior of the rolled U-10Mo foils were considered: grain size distribution, uranium carbide (UC) size distribution, UC volume fraction, spatial distribution of UC, and rolling reduction magnitude. Grain structure and the magnitude of rolling reduction have the strongest influence on recrystallization kinetics and the fabricated grain size distribution. The UC distribution had only a weak effect on the recrystallization kinetics and final microstructures. While particle-stimulated nucleation (PSN) occurred in simulation more frequently as grain size increased, its incidence did not appear to considerably affect the recrystallization kinetics or grain size distribution.
The study of quantum gravity in the form of the holographic duality has uncovered and motivated the detailed investigation of various diagnostics of quantum chaos. One such measure is the operator size distribution, which characterizes the size of the support region of an operator and its evolution under Heisenberg evolution. In this work, we examine the role of the operator size distribution in holographic duality for the Sachdev-Ye-Kitaev (SYK) model. Using an explicit construction of AdS 2 bulk fermion operators in a putative dual of the low temperature SYK model, we study the operator size distribution of the boundary and bulk fermions. Our result provides a direct derivation of the relationship between (effective) operator size of both the boundary and bulk fermions and bulk SL(2;$\mathbb{R}$) generators.
Reducing Ir loadings in proton exchange membrane water electrolyzer anodes is critical for lowering capital expenses. Loading reduction could be achieved by improving the Ir activity via doping/alloying and/or the development of advanced microstructures. However, the anode porous transport layer (PTL) is a comparatively simple component whose properties also impact Ir utilization. Therefore, well-designed PTLs may also enable reduced Ir loadings. In this work, we survey eight PTLs from various manufacturers to observe their impact on cell performance at low (0.4 mg Ir cm -2 ) and ultralow (0.1 mg Ir cm -2 ) Ir loadings. The PTLs were characterized by their microstructural properties, including porosity, particle size distribution, and pore size distribution. Electrochemical cell performance was correlated to PTL morphology, and it was found that PTLs with lower porosities and smaller particle and pore radii enabled good performance even at ultralow Ir loadings. 1000-h durability testing indicated that using lower porosity PTLs can significantly improve durability behavior. A runaway voltage phenomenon was observed during durability testing of cells with ultralow Ir loadings, which was caused by increases in both anode and cathode overpotentials. Furthermore, we observed that the beginning of test performance of 0.1 mg Ir cm -2 cells correlates to the 1000-h degradation rates of 0.4 mg Ir cm -2 cells, suggesting that for the Ir catalyst used in this work, short-term testing at ultralow loadings can be used as an indicator of long-term degradation at higher loadings.
The Pore2Chip Python package is designed to create 2D micromodels using extracted data from 3D X-ray computed tomography (XCT) images. This package helps analyze soil structure and function, allowing for the investigation of hydro-biogeochemical processes that impact mineral extraction and reactivity, oxygen concentrations, and nutrient availability in disturbed or managed soils. Key metrics encompass pore size distributions, pore throat size distributions, and connectivity (pore coordination numbers). The final output is a 2D scalable SVG design representing a core or aggregate. Designs can be fabricated with methods such as laser etching, 3D printing, and photolithography.
The Hygroscopic Tandem Differential Mobility Analyzer (H-TDMA) measures the hygroscopicity of atmospheric particles, and many atmospheric processes that change this hygroscopicity also change the atmospheric size distribution. Two assumptions made during H-TDMA inversion create spurious hygroscopic trends as a function of the changing inlet size distribution. These two assumptions—that the particles exiting the first Differential Mobility Analyzer (DMA1) are singly charged and that the inlet size distribution has a slope of zero (flat)— generate Multi-Charge Dispersion (MCD) bias and Slope bias, respectively. First, we use a model, named TAO, to show that the inlet size distribution could theoretically change the measured ammonium sulfate hygroscopicity by 10%–20% as a function of diameter or experimental time with no change in relative humidity. Secondly, we show experimentally that aerosol emitted from the flaming combustion of grass creates MCD bias. Here, in this experiment, we measure the CPC response of the first three charges and invert these responses using a new routine named Junior. Junior's inversion of each charge shows that one growth factor distribution describes all measured diameters (no growth dependence on diameter). As in the modeling study above, previous publications of this aerosol system, using traditional inversion assumptions, report a decrease in hygroscopicity as DMA1 diameter increases. Unlike traditional inversions, Junior's inversion does not assume the particles are singly charged nor does it make the flat inlet size distribution assumption. Instead, both the inlet size distribution and each charge's CPC response are measured quantities. Thus, the discrepancy between our inversion results and previous publications is likely due to the traditional inversion routine assumptions. This underscores the importance for accounting for Slope and MCD bias during inversions. Experimental results should be carefully analyzed when reporting hygroscopic trends with respect to diameter or experimental time when using the traditional inversion assumptions.