Development of medical electronic devices in the APL space department

Several electronic devices for automatically correcting specific defects in a body's physiologic regulation and allowing approximately normal functioning are described. A self-injurious behavior inhibiting system (SIBIS) is fastened to the arm of a person with chronic self-injurious behavior patterns. An electric shock is delivered into the arm whenever the device senses above-threshold acceleration of the head such as occur with head-bangers. Sounding a buzzer tone with the shock eventually allows transference of the aversive stimulus to the buzzer so shocks are no longer necessary. A programmable implantable medication system features a solenoid pump placed beneath the skin and refueled by hypodermic needle. The pump functions are programmable and can deliver insulin, chemotherapy mixes and/or pain killers according to a preset schedule or on patient demand. Finally, an automatic implantible defibrillator has four electrodes attached directly to the heart for sensing electrical impulses or emitting them in response to cardiac fibrillation.

Newman, A. L.↗

Feed status and skin injury modulate immunopathology, global gene expression, and survival in channel catfish during virulent Aeromonas hydrophila infection

Introduction VirulentAeromonas hydrophilais a major pathogen in channel catfish (Ictalurus punctatus), that causes motileAeromonassepticemia and significant economic losses. We investigated the effect of feeding status and skin integrity on the host immune response, disease survival, and gastrointestinal pathology following a vAh challenge. Methods Using a bath immersion model, channel catfish were divided into four treatment groups: fin clipped and fed (FCF), fin clipped but not fed (FCN), not fin clipped but fed (NCF), and not fin clipped nor fed (NCN) alongside non-challenged control groups The FCF and NCF groups were fed 2 h prior to the challenge, but the FCN and NCN groups were not. Survival analysis, histopathological assessment, and RNA sequencing were conducted across groups at different time intervals throughout the vAh challenge. Results Survival rates were lowest in the FCF and FCN groups (30% and 23% survival, respectively), suggesting that both feeding and skin damage contributed to disease severity. Histopathological analyses revealed more severe intestinal and gastric lesions in fed groups, characterized by epithelial necrosis, hemorrhage, and edema. Transcriptomic analysis among the groups identified significant differentially expressed genes associated with inflammation, apoptosis, and metabolic stress, with notable upregulation of interleukin 1-beta (il-1β), and complement C3 (c3). Gene ontology enrichment highlighted distinct immune activation patterns between fed and unfed groups, with enhanced pathogen recognition and pro-inflammatory responses in unfed fish. Discussion These findings suggest feeding prior to infection may exacerbate disease pathology, potentially by creating a physiological state conducive to facilitate pathogen proliferation and dampened early immune responses, whereas short-term fasting appears to promote early immune activation. This study provides novel insights into the complex interplay between feed status, physical injury, and immune response to vAh infection.

Immunology↗

Countermeasures for Mitigation of Sensorimotor Decrements Following Head-Down Tilt Bed Rest

BACKGROUND Astronauts experience postflight disturbances in postural and locomotor control due to sensorimotor adaptations during spaceflight. These alterations may have adverse consequences if a rapid egress is required after landing. Although exercise is partially effective for mitigating cardiovascular and muscular deconditioning, additional countermeasures are needed to further preserve sensorimotor function. Proprioception training and electrical muscle stimulation (EMS) are two promising in-flight countermeasures. Since prolonged head down tilt bed rest (HDTBR) is a spaceflight analog for body unloading and causes postural and locomotor control decrements that parallel those observed after spaceflight, it can be used to facilitate the development of these countermeasures. METHODS This study will determine the effects of proprioception training and EMS on functional task performance and sensorimotor function following 60 days of 6° HDTBR. Subjects will be randomly assigned to one of four groups: 1) an EMS arm, 2) a proprioception training arm, 3) an exercise plus proprioceptive training arm, and 4) a control arm. The EMS countermeasure will include daily bilateral stimulation of selected bilateral lower extremity muscles (30 minutes per session). Proprioception training will be performed three days per week (25 minutes per session) consisting of body-loaded postural tasks in the horizontal position on an air bearing sled. Exercise training will mimic current protocols used on the International Space Station, but treadmill aerobic exercise will be replaced with additional cycling aerobic exercise. Primary outcome measures will include pre- and post- HDTBR functional tests that require high demand for dynamic control of postural stability. Secondary measures will be used to explore key physiological changes that underlie countermeasure benefits. All HDTBR and data collection activities will be completed by the German Aerospace Center (DLR) at the :envihab facility. Given the constrained samples size, a Bayesian modelling approach will be used to quantify the probability that there is an effect of a given magnitude. HARDWARE AND PROTOCOL DEVELOPMENT Final hardware modifications and protocol developments were completed in preparation for Campaign 1, which began in September 2024. These included shipment, setup, and operator training for the transportable gravity bed, horizontal squat device, foam obstacle course, EMS devices, leg dexterity system, foot sole skin sensitivity system, and Radiofrequency Echographic Multi Spectrometry (REMS) ultrasound device. In addition, specialized protocols were developed for data collection using DLR’s equipment, including muscle morphology magnetic resonance imaging (MRI), optical coherence tomography, venous blood flow MRI and ultrasound, muscle ultrasound and impedance, and skin blood flow ultrasound. We will present early data from the first campaign, which concluded in November, 2024. These will be compared with previous data from the recent 30-day HDTBR campaigns (Spaceflight associated neuro-ocular syndrome countermeasures (SANS-CM)) conducted at DLR. RELEVANCE The deliverable from this project will be proof-of-concept sensorimotor countermeasure designs for functional task performance with full assessment of efficacy in a spaceflight analog. If one or more countermeasures are effective, they will be translated for validation with the suite of operationally implemented in-flight countermeasures.

T R Macaulay↗

Feature Selection Techniques for a Machine Learning Model to Detect Autonomic Dysreflexia

Feature selection plays a crucial role in the development of machine learning algorithms. Understanding the impact of the features on a model, and their physiological relevance can improve the performance. This is particularly helpful in the healthcare domain wherein disease states need to be identified with relatively small quantities of data. Autonomic Dysreflexia (AD) is one such example, wherein mismanagement of this neurological condition could lead to severe consequences for individuals with spinal cord injuries. We explore different methods of feature selection needed to improve the performance of a machine learning model in the detection of the onset of AD. We present different techniques used as well as the ideal metrics using a dataset of thirty-six features extracted from electrocardiograms, skin nerve activity, blood pressure and temperature. The best performing algorithm was a 5-layer neural network with five relevant features, which resulted in 93.4% accuracy in the detection of AD. The techniques in this paper can be applied to a myriad of healthcare datasets allowing forays into deeper exploration and improved machine learning model development. Through critical feature selection, it is possible to design better machine learning algorithms for detection of niche disease states using smaller datasets.

electrocardiography↗

Core Body Temperature Predictions Using Metabolic Energy Expenditure and Heart Rate During Simulated Extravehicular Activity

Long duration spaceflight missions will require crew to become more autonomous in conducting extravehicular activities (EVA) without direct communication with Mission Control for biomedical support. To enable such autonomy, we are developing a Crew State and Risk Model (CSRM) as a collection of key physiology domains that drive EVA crew capabilities and workloads. One model component of CSRM is human thermal regulation. In this paper, customized development of a baseline model to predict core body temperature is presented using physiology inputs of heart rate and metabolic rate. The model development dataset included a baseline study where participants (n=6, equal male and female) performed a 5-hour EVA in a two-part session while wearing a hybrid space suit simulator (HS3). The first session included an end-to-end EVA traversing 1500 meters to a geology site and traversing back to a habitat conducting geology, payload relocation, and maintenance operations every 500 meters. The second session included standalone tasks of a 2000-meter traverse followed by geology tasks. Thermal measures of core body temperature, local skin temperature, liquid cooling garment temperature, heart rate, and metabolic rate were collected through the test duration. Multiple regression was used to build a linear equation to predict core body temperature from inputs of heart rate and metabolic rate. Heat storage was calculated via predicted core body temperature plus LCG and skin temperatures. The model was tested against a dataset from a pressurized suited test (n=6, equal male and female) in the NASA Active Response Gravity Offload System (ARGOS) conducting similar end-to-end EVA and standalone tasks. Predicted error of the model against the raw test cases was 0.2±0.15 °C. The baseline prediction of core body temperature using heart rates and metabolic rates allows for simple real-time tracking from data collected in-flight to monitor crew consumables and thermal flight limits during EVA.

Bradley Hoffmann↗

Slow Wave Sleep and Long Duration Spaceflight

While ground research has clearly shown that preserving adequate quantities of sleep is essential for optimal health and performance, changes in the progression, order and /or duration of specific stages of sleep is also associated with deleterious outcomes. As seen in Figure 1, in healthy individuals, REM and Non-REM sleep alternate cyclically, with stages of Non-REM sleep structured chronologically. In the early parts of the night, for instance, Non-REM stages 3 and 4 (Slow Wave Sleep, or SWS) last longer while REM sleep spans shorter; as night progresses, the length of SWS is reduced as REM sleep lengthens. This process allows for SWS to establish precedence , with increases in SWS seen when recovering from sleep deprivation. SWS is indeed regarded as the most restorative portion of sleep. During SWS, physiological activities such as hormone secretion, muscle recovery, and immune responses are underway, while neurological processes required for long term learning and memory consolidation, also occur. The structure and duration of specific sleep stages may vary independent of total sleep duration, and changes in the structure and duration have been shown to be associated with deleterious outcomes. Individuals with narcolepsy enter sleep through REM as opposed to stage 1 of NREM. Disrupting slow wave sleep for several consecutive nights without reducing total sleep duration or sleep efficiency is associated with decreased pain threshold, increased discomfort, fatigue, and the inflammatory flare response in skin. Depression has been shown to be associated with a reduction of slow wave sleep and increased REM sleep. Given research that shows deleterious outcomes are associated with changes in sleep structure, it is essential to characterize and mitigate not only total sleep duration, but also changes in sleep stages.

Whitmire, Alexandra↗

Pre-exercise hypervolemia and cycle ergometer endurance in men

Time to exhaustion at 87-91% of peak VO2 was measured in 5 untrained men (age: 31 +/- 8 years, body mass: 74.20 +/- 16.50 kg, body surface area: 1.90 +/- 0.24 m2, peak VO2: 2.87 +/- 0.40 l min-1, plasma volume: 3.21 +/- 0.88 l; means +/-SD) after consuming nothing (N) or two fluid formulations (10 ml kg-1, 743 +/- 161 ml): Performance 1 (P1), a multi-ionic carbohydrate drink, containing 55 mEq l-1 Na+, 4.16 g l-1 citrate, 20.49 g l-1 glucose, and 365 mOsm kg-1 H2O, and AstroAde (AA), a sodium chloride-sodium citrate hyperhydration drink, containing 164 mEq l-1 Na+, 8.54 g l-1 citrate, <5 mg l-1 glucose, and 253 mOsm kg-1 H2O. Mean (+/-SE) endurance for N, P1 and AA was 24.68 +/- 1.50, 24.55 +/- 1.09, and 30.50 +/- 3.44 min respectively. Percent changes in plasma volume (PV) from -105 min of rest to zero min before exercise were -1.5 +/- 3.2% (N), 0.2 +/- 2.2% (P1), and 4.8 +/- 3.0% (AA; P < 0.05). The attenuated endurance for N and P1 could not be attributed to differences in exercise metabolism (VE, RE, VO2) from the carbohydrate or citrate, terminal heart rate, levels of perceived exertion, forehead or thigh skin blood flow velocity, changes or absolute termination levels of rectal temperature. Thus, the higher level of resting PV for AA just before exercise, as well as greater acid buffering and possible increased energy substrate from citrate, may have contributed to the greater endurance.

NASA Center ARC↗

Augmentation of blood circulation to the fingers by warming distant body areas

Future activities in space will require greater periods of time in extreme environments in which the body periphery will be vulnerable to chilling. Maintaining the hands and fingers in comfortable conditions enhances finger flexibility and dexterity, and thus effects better work performance. We have evaluated the efficacy of promoting heat transfer and release by the extremities by increasing the blood flow to the periphery from more distant parts of the body. The experimental garment paradigm developed by the investigators was used to manipulate the temperature of different body areas. Six subjects, two females and four males, were evaluated in a stage-1 baseline condition, with the inlet temperature of the circulating water in the liquid cooling/warming garment (LCWG) at 33 degrees C. At stage 2 the total LCWG water inlet temperature was cooled to 8 degrees C, and at stage 3 the inlet water temperature in specific segments of the LCWG was warmed (according to protocol) to 45 degrees C, while the inlet temperature in the rest of the LCWG was maintained at 8 degrees C. The following four body-area-warming conditions were studied in separate sessions: (1) head, (2) upper torso/arm, (3) upper torso/arm/head, and (4) legs/feet. Skin temperature, heat flux and blood perfusion of the fingers, and subjective perception of thermal sensations and overall physical comfort were assessed. Finger temperature (T(fing)) analyses showed a statistically significant condition x stage interaction. Post-hoc comparisons (T(fing)) indicated that at stage 3, the upper torso/arm/head warming condition was significantly different from the head, upper torso/arm and legs/feet conditions, showing an increase in T(fing). There was a significant increase in blood perfusion in the fingers at stage 3 in all conditions. Subjective perception of hand warmth, and overall physical comfort level significantly increased in the stage 3 upper torso/arm/head condition. The findings indicate that physiological methods to enhance heat transfer by the blood to the periphery within protective clothing provide an additional tool for increasing total and local human comfort in extreme environments.

NASA Discipline Life Sciences Technologies↗

Developing a Hybrid Spacesuit Simulator as a Research Tool for Assessing Extravehicular Activity Relevant Workload

Conducting human tests in a pressurized spacesuit is limited by availability, cost, and manpower; however, pressurized spacesuits are not always needed depending on the objectives of testing, including the development and testing of new informatics capabilities. The Human Physiology, Performance, Protection & Operations Laboratory (H-3PO) at NASA is developing a Hybrid Spacesuit Simulator (HS3) to support testing and characterization of human performance during analog planetary exploration extravehicular activities (EVAs). The goal of HS3 is to create a low-cost, modular, and unpressurized spacesuit simulator as a research tool that provides relevant physical and cognitive workload approximations with EVA-like immersion. HS3 consists of a soft outer suit, thermal control, gloves, boots, helmet, and integrated bioinformatics and communications. Baseline HS3 assessments were performed during 3-hour EVA simulations in two different subjects (DEMO1 and DEMO2) that included traverses at variable resistances and geological sampling activities. Liquid cooling garment (LCG) temperature, mean skin temperature, heart rate, motion capture, and metabolic rate were collected during each 3-hour simulated EVA. During DEMO1 and DEMO2, baseline metabolic rates at rest were 836 ± 327 BTU/hr and 869 ± 207 BTU/hr and increased to 2124 ± 548 BTU/hr and 2269 ± 559 BTU/hr, respectively, during 500m traverse. Average inlet LCG temperatures were 29.57 ± 6.62 °C and 25.63 ± 6.48 °C for DEMO1 and DEMO2 with increased outlet LCG temperatures of 33.53 ± 6.62 °C and 29.21 ± 4.79 °C, respectively. Overall, HS3 will enable future studies to characterize EVA tasks, human performance, and test future EVA capabilities in analog test environments without the need for pressurized suited environments.

Monica Hew↗

Developing A Hybrid Spacesuit Simulator as A Research Tool for Assessing Extravehicular Activity Relevant Workload

Conducting human tests in a pressurized spacesuit is limited by availability, cost, and manpower; however, pressurized spacesuits are not always needed depending on the objectives of testing, including the development and testing of new informatics capabilities. The Human Physiology, Performance, Protection & Operations Laboratory (H-3PO) at NASA is developing a Hybrid Spacesuit Simulator (HS3) to support testing and characterization of human performance during analog planetary exploration extravehicular activities (EVAs). The goal of HS3 is to create a low-cost, modular, and unpressurized spacesuit simulator as a research tool that provides relevant physical and cognitive workload approximations with EVA-like immersion. HS3 consists of a soft outer suit, thermal control, gloves, boots, helmet, and integrated bioinformatics and communications. Baseline HS3 assessments were performed during 3-hour EVA simulations in two different subjects (DEMO1 and DEMO2) that included traverses at variable resistances and geological sampling activities. Liquid cooling garment (LCG) temperature, mean skin temperature, heart rate, motion capture, and metabolic rate were collected during each 3-hour simulated EVA. During DEMO1 and DEMO2, baseline metabolic rates at rest were 836 ± 327 BTU/hr and 869 ± 207 BTU/hr and increased to 2124 ± 548 BTU/hr and 2269 ± 559 BTU/hr, respectively, during 500m traverse. Average inlet LCG temperatures were 29.57 ± 6.62 °C and 25.63 ± 6.48 °C for DEMO1 and DEMO2 with increased outlet LCG temperatures of 33.53 ± 6.62 °C and 29.21 ± 4.79 °C, respectively. Overall, HS3 will enable future studies to characterize EVA tasks, human performance, and test future EVA capabilities in analog test environments without the need for pressurized suited environments.

Suit simulator↗

Evaluation of Cutaneous Blood Flow During Lower Body Negative Pressure to Prevent Orthostatic Intolerance of Bedrest

Orthostatic tolerance is markedly impaired in most of the crewmembers during space flight and could seriously compromise crew safety during and immediately after landing. NASA investigators are studying the use of lower body negative pressure (LBNP) as a countermeasure to this intolerance. It is hypothesized that the continuously changing vascular pressure induced by sinusoidal LBNP with an additional countermeasure of salt and water will help crewmembers to be in a more acceptable physiologic condition to enter the earth's atmosphere. In ground based studies, subjects on bedrest provide the model for studying the physiologic effects of weightlessness. When subjects are treated with sinusoidal LBNP, negative pressures ranging from 0 to -60 mm/Hg are administered during a two hour period. This increases body fluids in the legs and lower body. This paper reports the results of two subjects who were placed on bedrest for six days. The subjects were randomly selected for either the control or treatment mode. The subject receiving the treatment mode ingested salt tablets and water on day 4 of the bedrest period. A ramp LBNP of two hours was next administered to this subject. The control subject did not receive anything during the bedrest period. Laser Doppler was used to measure the cutaneous blood flow of the forearm and calf to monitor vasoconstrictor effects of the baroreceptor reflex. Data indicated that skin blood flow in the treatment subject was higher than baseline in the forearm while the skin blood flow was decreased in the control subject.

Rubin, Marilyn↗

A physical control interface with proprioceptive feedback and multiple degrees of freedom

The use of the drug thalidomide by pregnant mothers in Britain resulted in a variety of deformities including the birth of children having no arms. Such children were provided with powered artificial arms with up to five degrees of freedom simultaneously controlled in real time by shoulder movement. The physiological sense of proprioception was extended from the user into the device, reducing the need for visual feedback and conscious control. With the banning of thalidomide, this technique fell into disuse but it is now being re-examined as a control mechanism for other artificial limbs and it may have other medical applications to allow patients to control formerly paralyzed limbs moved by electrical stimulation. It may also have commercial applications in robotic manipulation or physical interaction with virtual environments. To allow it to be investigated further, the original pneumatic control system has recently been converted to an electrical analogue to allow interfacing to electronic and computer-assisted systems. A harness incorporates force-sensitive resistors and linear potentiomenters for sensing position and force at the interface with the skin, and miniature electric motors and lead screws for feeding back to the user the position of the robotic arm and the forces applied to it. In the present system, control is applied to four degrees of freedom using elevation/depression and protraction/reaction of each shoulder so that each collar bone emulates a joystick. However, both electrical and mechanical components have been built in modular form to allow rapid replication and testing of a variety of force and position control strategies.

Creasey, G. H.↗

Cardiovascular and sympathetic neural responses to handgrip and cold pressor stimuli in humans before, during and after spaceflight

Astronauts returning to Earth have reduced orthostatic tolerance and exercise capacity. Alterations in autonomic nervous system and neuromuscular function after spaceflight might contribute to this problem. In this study, we tested the hypothesis that exposure to microgravity impairs autonomic neural control of sympathetic outflow in response to peripheral afferent stimulation produced by handgrip and a cold pressor test in humans. We studied five astronauts approximately 72 and 23 days before, and on landing day after the 16 day Neurolab (STS-90) space shuttle mission, and four of the astronauts during flight (day 12 or 13). Heart rate, arterial pressure and peroneal muscle sympathetic nerve activity (MSNA) were recorded before and during static handgrip sustained to fatigue at 40 % of maximum voluntary contraction, followed by 2 min of circulatory arrest pre-, in- and post-flight. The cold pressor test was applied only before (five astronauts) and during flight (day 12 or 13, four astronauts). Mean (+/- S.E.M.) baseline heart rates and arterial pressures were similar among pre-, in- and post-flight measurements. At the same relative fatiguing force, the peak systolic pressure and mean arterial pressure during static handgrip were not different before, during and after spaceflight. The peak diastolic pressure tended to be higher post- than pre-flight (112 +/- 6 vs. 99 +/- 5 mmHg, P = 0.088). Contraction-induced rises in heart rate were similar pre-, in- and post-flight. MSNA was higher post-flight in all subjects before static handgrip (26 +/- 4 post- vs. 15 +/- 4 bursts min(-1) pre-flight, P = 0.017). Contraction-evoked peak MSNA responses were not different before, during, and after spaceflight (41 +/- 4, 38 +/- 5 and 46 +/- 6 bursts min(-1), all P > 0.05). MSNA during post-handgrip circulatory arrest was higher post- than pre- or in-flight (41 +/- 1 vs. 33 +/- 3 and 30 +/- 5 bursts min(-1), P = 0.038 and 0.036). Similarly, responses of MSNA and blood pressure to the cold pressor test were well maintained in-flight. We conclude that modulation of muscle sympathetic neural outflow by muscle metaboreceptors and skin nociceptors is preserved during short duration spaceflight.

NASA Discipline Neuroscience↗

User Interactive Software for Analysis of Human Physiological Data

Ambulatory physiological monitoring has been used to study human health and performance in space and in a variety of Earth-based environments (e.g., military aircraft, armored vehicles, small groups in isolation, and patients). Large, multi-channel data files are typically recorded in these environments, and these files often require the removal of contaminated data prior to processing and analyses. Physiological data processing can now be performed with user-friendly, interactive software developed by the Ames Psychophysiology Research Laboratory. This software, which runs on a Windows platform, contains various signal-processing routines for both time- and frequency- domain data analyses (e.g., peak detection, differentiation and integration, digital filtering, adaptive thresholds, Fast Fourier Transform power spectrum, auto-correlation, etc.). Data acquired with any ambulatory monitoring system that provides text or binary file format are easily imported to the processing software. The application provides a graphical user interface where one can manually select and correct data artifacts utilizing linear and zero interpolation and adding trigger points for missed peaks. Block and moving average routines are also provided for data reduction. Processed data in numeric and graphic format can be exported to Excel. This software, PostProc (for post-processing) requires the Dadisp engineering spreadsheet (DSP Development Corp), or equivalent, for implementation. Specific processing routines were written for electrocardiography, electroencephalography, electromyography, blood pressure, skin conductance level, impedance cardiography (cardiac output, stroke volume, thoracic fluid volume), temperature, and respiration

Cowings, Patricia S.↗

Gravity and thermoregulation: metabolic changes and circadian rhythms

Gravity appears to alter thermoregulation through changes in both the regulated level of body temperature and the rhythmic organization of temperature regulation. Gravity has been hypothesized to have an associated metabolic cost. Increased resting energy expenditure and dietary intake have been observed in animals during centrifuge experiments at hypergravity. Thus far, only animals have shown a corresponding reduction in metabolism in microgravity. Altered heat loss has been proposed as a response to altered gravitational environments, but remains documented only as changes in skin temperature. Changes in circadian timing, including the body temperature rhythm, have been shown in both hypergravity and microgravity, and probably contribute to alterations in sleep and performance. Changes in body temperature regulation may result from circadian disturbance, from the direct or indirect actions of gravity on the regulated temperature, or from changes in thermoregulatory effectors (heat production and heat loss) due to altered gravitational load and convective changes. To date, however, we have little data on the underlying thermoregulatory changes in altered gravity, and thus the precise mechanisms by which gravity alters temperature regulation remain largely unknown.

Non-NASA Center↗

Countermeasures for Mitigation of Sensorimotor Decrements Following Head-Down Bed Rest

BACKGROUND Astronauts experience postflight disturbances in postural and locomotor control due to sensorimotor adaptations during spaceflight. These alterations may have adverse consequences if a rapid egress is required after landing. Although exercise is partially effective for mitigating cardiovascular and muscular deconditioning, additional countermeasures are needed to further preserve sensorimotor function for exploration missions. We have identified proprioceptive training and electrical muscle stimulation (EMS) as promising in-flight countermeasures. Since prolonged head down bed rest (HDBR) is a spaceflight analog for body unloading and causes postural and locomotor control decrements that parallel those observed after spaceflight, it can be used to facilitate the development of these countermeasures. METHODS This study will determine the effects of proprioceptive training and EMS on functional task performance and sensorimotor function following 60 days of 6° HDBR. Subjects will be randomly assigned to one of four groups: 1)an EMS arm, 2) a proprioceptive training arm, 3) an exercise plus proprioceptive training arm, and 4) a control arm. The EMS countermeasure will include daily bilateral stimulation of selected bilateral lower extremity muscles (30 minutes per session). Proprioceptive training will be performed three days per week (20 minutes per session) consisting of body-loaded postural tasks in the horizontal position on an air bearing sled. Exercise training will mimic current protocols used on the International Space Station, but treadmill aerobic exercise will be replaced with additional cycling aerobic exercise. Primary outcome measures will include pre and post HDBR functional tests that are representative of high priority exploration mission tasks and require high demand for dynamic control of postural stability. Additional measures will be used to identify the key physiological factors contributing to countermeasure benefits. Given the constrained samples size, a Bayesian modelling approach will be used to quantify the probability that there is an effect of a given magnitude. HARDWARE AND PROTOCOL DEVELOPMENT Proprioceptive countermeasure design enhancements continued as part of the Mars Campaign Office (MCO) Crew Health and Performance (CHP) Crew Health Countermeasures (CHC). The primary goals of this work were to assemble a portable version of the countermeasure system that can be used at the :envihab facility, expand the software feedback system’s capabilities, and develop an actuator loading system that mimics what could be used on the International Space Station. In addition, one major piece of exercise hardware used in previous HDBR studies, the Horizontal Squat Device, was reassembled and restored to full functionality. Human-in-the-loop pilot testing is ongoing, prior to shipping both devices to the :envihab HDBR facility. Evaluations are also underway for the best EMS device technologies and specific methods. Finally, assessment techniques are being translated for administration in the horizontal position (e.g., leg dexterity and foot sole skin sensitivity). Our current goals are to refine the countermeasure training and assessment techniques and integrate protocols across multiple modalities. RELEVANCE The deliverable from this project will be proof-of-concept sensorimotor countermeasure designs for functional task performance with full assessment of efficacy in a spaceflight analog. If one or more countermeasures are effective, they will be translated for validation with the suite of operationally implemented in-flight countermeasures. ACKNOWLEDGEMENT This work is supported by NASA’s Human Research Program Human Health Countermeasures Element and by the Canadian Space Agency (L. Bent).

T R Macaulay↗

[Individual characteristics of correction of the cosmonauts' vegetative status with a method of adaptive biofeedback]

The ability of 4 cosmonauts to voluntarily control their physiological parameters during the standing test was evaluated following a series of the adaptive feedback (AF) training sessions. Vegetative status of the cosmonauts during voluntary "relaxation" and "straining" was different when compared with its indices determined before these sessions. In addition, there was a considerable individual variability in the intensity and direction of the AF effects, and the range of parameters responding to AF. It was GCR which was the easiest one for the AF control.

NASA Center ARC↗

Operational Characteristics of Two Commercially Available Personal Cooling Vests

Personal thermoregulatory systems which provide chest cooling are used in the industrial and aerospace environments to alleviate thermal stress. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to compare the effectiveness of two passive cooling vests, and to measure the body temperature and circulatory changes produced by each cooling vest configuration. A Life Enhancement Technologies, (LET) ice vest garment and a Steele, Inc. vest were used to cool the chest region of 11 male subjects (25 to 55 yr) in this study. Calf, forearm and finger blood flows were measured using a tetrapolar impedance rheograph. The subjects, seated in an upright position at normal room temperature (approximately 21 C) were tested for 60 min. with the cooling system operating at its maximum cooling capacity. Blood flows were recorded continuously using a computer data acquisition system with a sampling frequency of 250 Hz. Oral, right and left ear temperatures and cooling system parameters were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; respiration; and an activity index were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. No significant differences were found in either the oral or ear temperature responses to the two vests. However, the rectal and mean skin temperatures at the end of the cooling period were both significantly lower (P less than 0.05), approximately 0.2 and 1.9 C, respectively for the LET vest than for the Steele garment. These data show that different vest configurations may produce different thermal responses in healthy male subjects which should be considered in the use of these cooling garments.

Ku, Yu-Tsuan E.↗