Search NASA⌕ Search

SEARCH · Search NASA

Results for “SnS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

BEAM DYNAMICS ISSUES IN THE SNS LINAC

A review of the Spallation Neutron Source (SNS) linac beam dynamics is presented. It describes transverse and longitudinal beam optics, losses, activation, and comparison between the initial design and the existing accelerator. The SNS linac consists of normal conducting and superconducting parts. The peculiarities in operations with the superconducting part of the SNS linac (SCL), estimations of total losses in SCL, the possible mechanisms of these losses, and the progress in the transverse matching are discussed.

43 PARTICLE ACCELERATORS↗

A QUEST FOR SYSTEM FRIENDLINESS WITH THE SNS ION BEAM BUNCH SHAPE MONITOR

A new system for measuring the SNS ion beam longitudinal profile was recently upgraded to operational status. The hardware for this device was developed and delivered by Institute of Nuclear Research to the SNS as a part of its initial construction. The supplied LabVIEW user interface software was intended for proof-of-operation and initial setup of the instrument. While satisfactory for this, it was tedious to use in a practical context and lacked any form of interface to the SNS EPICS based control system. This paper will describe the software features added to make this instrument both easily tunable to the prevalent beam conditions by system engineers and easily usable by accelerator physicists only interested in its output data.

43 PARTICLE ACCELERATORS↗

The First ASME Code Stamped Cryomodule at SNS

The first spare cryomodule for the Spallation Neutron Source (SNS) has been designed, fabricated, and tested by SNS personnel. The approach to design for this cryomodule was to hold critical design features identical to the original design such as bayonet positions, coupler positions, cold mass assembly, and overall footprint. However, this is the first SNS cryomodule that meets the pressure requirements put forth in the 10 CFR 851: Worker Safety and Health Program. The most significant difference is that Section VIII of the ASME Boiler and Pressure Vessel Code was applied to the vacuum vessel of this cryomodule. Applying the pressure code to the helium vessels within the cryomodule was considered. However, it was determined to be schedule prohibitive because it required a code case for materials that are not currently covered by the code. Good engineering practice was applied to the internal components to verify the quality and integrity of the entire cryomodule. The design of the cryomodule, fabrication effort, and cryogenic test results will be reported in this paper.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

STATUS OF SRF FACILITIES AT SNS

The Spallation Neutron Source (SNS) has recognized the need for developing in-house capability to ensure long term sustainability of the superconducting linac (SCL). SNS has made substantial gains in the last 6 years in understanding SCL operation, including system and equipment limiting factors, and resolution of system and equipment issues. Significant effort and focus is required to assure on-going success in the operation, maintenance, and improvement of the SCL and to address the requirements of the upgrade project for the Second Target Station. These interdependent efforts include implementation of demonstrated improvements, fabrication of spare cryomodules, cavity R&D to enhance machine performance, and related SRF facility developments. Cryomodule and vertical cavity testing facilities are being developed to demonstrate process capabilities and to further understand the collective limitations of installed cavities. The status and future plans for SRF facilities at SNS will be presented.

Kim, Sang-Ho↗

Beam Loss due to Foil Scattering in the SNS Accumulator Ring

In order to better understand the contribution of scattering from the primary stripper foil to losses in the SNS ring, we have carried out calculations using the ORBIT Code aimed at evaluating these losses. These calculations indicate that the probability of beam loss within one turn following a foil hit is ~1.8 10-8 , where is the foil thickness in g/cm2, assuming a carbon foil. Thus, for a typical SNS stripper foil of thickness = 390 g/cm2, the probability of loss within one turn of a foil hit is ~7.0 10-6. This note describes the calculations used to arrive at this result, presents the distribution of these losses around the SNS ring, and compares the calculated results with observed ring losses for a well-tuned production beam.

Holmes, Jeffrey A↗

Commissioning and operation of the horizontal test apparatus at SNS

The Spallation Neutron Source (SNS) at Oak Ridge National Lab (ORNL) has built, commissioned and operated a Horizontal Test Apparatus (HTA) vessel in the Radiofrequency Test Facility (RFTF) test cave. It can be operated at 4.5 K using the independent Cryogenic Test Facility (CTF). The HTA is designed to be a single cavity version of an SNS cryomodule with the ability to demount and replace the cavity. It provides the functionality for testing a single dressed SNS medium or high beta Superconducting Radiofrequency (SRF) cavity. The HTA is currently being used in support of R&D for in-situ plasma processing of the cavity's inner niobium surface. The design and commissioning of the HTA at 4.5 K will be presented as well as results from operating the HTA including cool-down, warm-up and steady state operations. Results from plasma processing a warm SCRF cavity in-between cold HTA tests will also be reported.

Kim, Sang-Ho↗

Target Control and Protection Systems Lessons from SNS Operations

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory has been in operations since 2006 and proposes a project to build a Second Target Station (STS) to effectively double potential scientific output. The SNS target controls operate in a harsh environment which includes high radiation, exposure to gaseous radionuclides, and activated liquid mercury and mercury vapor. These conditions necessitate protective interlocks and credited controls for protection functions to ensure proper response to off-normal conditions. In order to inform the design of target controls for the STS, we have examined lessons learned during SNS operations regarding the design and implementation of the control and protection systems for the first target station (FTS). This paper will examine various aspects of the performance of the target control and protection systems including reliability, maintainability and sustainability given the challenging environment created by 1.4 MW operations. Specific topics include distributed control of various target subsystems, response to loss of power, selection of nuclear grade instrumentation, and applying these lessons to the design for the STS project.

Humphreys, Dana↗

SNS Sample Activation Calculator Experimental Validation - Paper 79

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) uses the Sample Activation Calculator (SAC) to calculate the activation of all samples after they have been exposed to the neutron beam in any of the neutron scattering instruments at the SNS beamlines. The SAC web page takes user inputs (choice of beamline, the mass, composition and area of the sample, irradiation time, decay time, etc.) and then calculates the activation for the sample. In recent years, the SAC has been incorporated into the user proposal and sample handling process, and beamline scientists and users have noticed discrepancies in the predicted activation of their samples. As a part of the Neutronics Analysis Group at SNS, we were tasked with validating the SAC tool and diagnosing the origin of the discrepancies seen by the beamline scientists and the users. In the process of performing these measurements, we additionally found that several aspects of realistic neutron scattering operations, and thus sample exposure, cannot be captured with current configuration of the SAC tool. Typical neutron scattering samples are irradiated for multiple periods with different neutron energy ranges; the realities of accelerator operation indicate that not all of those periods will be at the same accelerator power, and scattering samples are frequently not fully illuminated by the well-collimated neutron beam. Finally, we will explore whether neutron beams, as modified by neutron guide systems with energy-dependent intensity modifications and by precise energy-band defining mechanical choppers, are suitably analyzed with multigroup cross section libraries in which there are typically very few energy groups below one eV. (authors)

43 PARTICLE ACCELERATORS↗

A COMPACTRIO-BASED BEAM LOSS MONITOR FOR THE SNS RF TEST CAVE

An RF Test Cave has been built at the Spallation Neutron Source (SNS) to be able to test RF cavities without interfering the SNS accelerator operations. In addition to using thick concrete wall to minimize radiation exposure, a Beam Loss Monitor (BLM) must abort the operation within 100 usec when the integrated radiation within the cave exceeds a threshold. We choose the CompactRIO platform to implement the BLM based on its performance, cost-effectiveness, and rapid development. Each in/output module is connected through an FPGA to provide point-by-point processing. Every 10 usec the data is acquired analyzed and compared to the threshold. Data from the FPGA is transferred using DMA to the real-time controller, which communicates to a gateway PC to talk to the SNS control system. The system includes diagnostics to test the hardware and integrates the losses in real-time. In this paper we describe our design, implementation, and results

43 PARTICLE ACCELERATORS↗

15 years of spin-echo spectroscopy at SNS-NSE: Looking back and looking forward

High-resolution neutron spin echo (NSE) spectroscopy offers unique insights into the mobility of molecular (sub)structures excited by thermal fluctuations (i.e., Brownian motion) of “soft matter” as polymers in solution and in the melt, in biological matter (e.g., protein motions), membranes, and glasses. The ability to tag substructures using H, D contrast variation to resolve the relevant timescales of dynamics on selected molecular items in liquids, soft matter, and melts is a significant advantage of NSE. Also slow magnetic fluctuations on molecular length scales in the range of nanoseconds, e.g., in spin glasses or topological spin structures, can be accessed. This paper reviews the highlights and peculiarities of the SNS-NSE, based at the pulsed neutron source SNS, during its first 1.5 decades of operation. An outlook and perspectives of research in the domain of high-resolution spectroscopy is given.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Data Processing for the SNS EQ-SANS Diffractometer

The scattering data on the Extended Q-Range Small Angle Scattering Diffractometer at the Spallation Neutron Source are stored as neutron events. Each event has two parts: the time of fight of the detected neutron, and an identifier for the neutron's location on the detector. In addition, each event is associated with the source pulse from which the neutron is originated. Due to the high neutron beam intensity at the SNS, the size of the stored data files can easily exceed several Gigabytes. Processing and reducing these data can be very time consuming. The standard way of handling the data at the SNS has been to first transform the data into histograms. On the EQ-SANS, these histograms are further processed into intensity I vs. neutron momentum transfer Q files, I(Q). For a large data, the whole process can take many minutes to hours to complete, which severely limits the turnaround time of an experiment. Experimenters often want to reduce the data quickly and depending on the result, make decisions on the setup of next measurements. They may also need to reduce the data using different inputs and conditions. In this work, we present the implementation of a fast data processing scheme for the EQ-SANS diffractometer. The scattering data are processed directly from neutron event files into I(Q) or other desired formats, greatly reducing the needed computation time. Further speed gains are obtained by the implementation of parallel computing under the Message Passing Interface framework. Most data on the EQ-SANS can now be handled in mere seconds. The process is highly automated. All relevant experimental information that is stored in instrument configuration files are read and processed. In addition, the new implementation is highly flexible. All the data corrections and handlings can be controlled transparently through user inputs. Finally, software implementation enables the slicing of neutron event, which can be used for the study of time dependent phenomena.

Data Processing↗

Materials Data on SnS by Materials Project

SnS crystallizes in the orthorhombic Cmcm space group. The structure is two-dimensional and consists of two SnS sheets oriented in the (0, 1, 0) direction. Sn2+ is bonded in a rectangular see-saw-like geometry to four equivalent S2- atoms. There are two shorter (2.61 Å) and two longer (2.93 Å) Sn–S bond lengths. S2- is bonded in a distorted rectangular see-saw-like geometry to four equivalent Sn2+ atoms.

36 MATERIALS SCIENCE↗

Materials Data on SnS by Materials Project

SnS is Hittorf-derived structured and crystallizes in the orthorhombic Pnma space group. The structure is two-dimensional and consists of two SnS sheets oriented in the (0, 0, 1) direction. Sn2+ is bonded in a distorted T-shaped geometry to three equivalent S2- atoms. There are one shorter (2.66 Å) and two longer (2.69 Å) Sn–S bond lengths. S2- is bonded in a trigonal non-coplanar geometry to three equivalent Sn2+ atoms.

36 MATERIALS SCIENCE↗

Materials Data on SnS by Materials Project

SnS crystallizes in the orthorhombic Aem2 space group. The structure is zero-dimensional and consists of four SnS clusters. Sn2+ is bonded in a distorted single-bond geometry to one S2- atom. The Sn–S bond length is 2.58 Å. S2- is bonded in a distorted single-bond geometry to one Sn2+ atom.

36 MATERIALS SCIENCE↗

Materials Data on SnS by Materials Project

SnS crystallizes in the orthorhombic Cmcm space group. The structure is two-dimensional and consists of two SnS sheets oriented in the (0, 1, 0) direction. Sn2+ is bonded to five equivalent S2- atoms to form a mixture of edge and corner-sharing SnS5 square pyramids. There are one shorter (2.60 Å) and four longer (2.92 Å) Sn–S bond lengths. S2- is bonded to five equivalent Sn2+ atoms to form a mixture of edge and corner-sharing SSn5 square pyramids.

36 MATERIALS SCIENCE↗

Materials Data on SnS by Materials Project

SnS crystallizes in the orthorhombic Aem2 space group. The structure is two-dimensional and consists of one SnS sheet oriented in the (0, 0, 1) direction. Sn2+ is bonded in a 5-coordinate geometry to five equivalent S2- atoms. There are a spread of Sn–S bond distances ranging from 2.58–3.20 Å. S2- is bonded in a distorted single-bond geometry to five equivalent Sn2+ atoms.

36 MATERIALS SCIENCE↗

Materials Data on SnS by Materials Project

SnS crystallizes in the triclinic P-1 space group. The structure is two-dimensional and consists of one SnS sheet oriented in the (0, 0, 1) direction. Sn2+ is bonded to five equivalent S2- atoms to form a mixture of distorted edge and corner-sharing SnS5 square pyramids. There are a spread of Sn–S bond distances ranging from 2.58–2.95 Å. S2- is bonded in a distorted single-bond geometry to five equivalent Sn2+ atoms.

36 MATERIALS SCIENCE↗

Virtual to Physical: Reinforcement Learning to Optimize SNS Particle Accelerator Controls

Complex accelerators must have control systems that can handle dynamic nonlinear environments. This makes traditional control methods unsuitable as they can struggle to adapt to these uncertainties. This provides an ideal environment for reinforcement learning algorithms as they are adaptable and generalizable. We present a reinforcement learning pipeline that can effectively handle the dynamics of a complex accelerator. We test and prove our pipelines capabilities on multiple environments including the Spallation Neutron Source (SNS) and the Beam Test Facility (BTF) at Oakridge National Lab (ORNL). Due to the limited time available to train an online algorithm like reinforcement learning on a real accelerator, we utilize a virtual twin accelerator (VIRAC) developed by ORNL to pretrain the policy and show its ability to converge in the virtual environment. We then test the adaptability of the pretrained RL model by applying it on the real accelerator and comparing the results. Utilizing our Scientific Optimization and Controls Toolkit (SOCT) and open-source standards such as Gymnasium we create and solve for a MEBT orbit correction problem in the SNS and an emittance maximization problem in the BTF. We show how Twin Delayed Deep Deterministic Policy Gradient (TD3) can solve this optimization environment in the virtual accelerator and transfer this policy onto the real accelerator for inference and model retraining. We show how reinforcement learning can be utilized as a control system for complex accelerators and provide a model pipeline for how an implementation performs and can be adapted to new accelerator control problems.

Kasparian, Armen [Thomas Jefferson National Accele↗